Sie sind auf Seite 1von 4

PV Elite 2019 SP2 Licensee 1

FileName : Seal Pot --------------------------------------


Leg Check, (Operating Case): Step: 17 9:45am Jan 15,2020

RESULTS FOR LEGS : Operating Case Description: LEGS

Legs attached to: Shell

Section Properties : Sq/Rect Tubing BT50X50X6.3

European Structural Steel Data

Overall Leg Length 870.000 mm


Effective Leg Length Leglen 870.000 mm
Distance Leg Up Side of Vessel 0.000 mm
Number of Legs Nleg 2
Cross Sectional Area for BT50X50X6.3 Aleg 1101.238 mm²
Section Inertia ( strong axis ) 357787.219 mm**4
Section Inertia ( weak axis ) 357787.219 mm**4
Section Modulus ( strong axis ) 14311.658 mm ³
Section Modulus ( weak axis ) 14311.658 mm ³
Radius of Gyration ( strong axis ) 18.025 mm
Radius of Gyration ( weak axis ) 18.025 mm

Leg Orientation - Weak Axis

Overturning Moment at top of Legs 61.4 N-m


Total Weight Load at top of Legs W 680.7 N
Total Shear force at top of Legs 217.7 N
Additional force in Leg due to Bracing Fadd 0.0 N
Occasional Load Factor Occfac 1.333
Effective Leg End Condition Factor k 1.000

Note: The Legs are Not Cross Braced


The Leg Shear Force includes Wind and Seismic Effects

Maximum Shear at top of one Leg [Vleg]:


= ( max( Wind, Seismic ) + applied forces )( Imax / Itot )
= ( 217.7 )( 357791/715582 )
= 108.84 N

Axial Compression, Leg furthest from the Neutral Axis [Sma]:


= W/Nleg + (Mleg/(Nlegm*Rn))/Aleg
= 680.8/2 + (61412/( 1 * 109.1 ))/1101
= 8.36 kgf/cm²

Axial Compression, Leg closest to the Neutral Axis [Sva]:


= ( W / Nleg ) / Aleg
= ( 680.7/2 )/1101
= 3.15 kgf/cm²

Allowable Comp. for the Selected Leg (KL/r < Cc ) [Sa]:


= Occfac * ( 1-(kl/r)²/(2*Cc²))*Fy /
( 5/3+3*(Kl/r)/(8*Cc)-(Kl/r³)/(8*Cc³)
= 1.333 * ( 1-( 48.27 )²/(2 * 127.2² )) * 2531/
( 5/3+3*( 48.27 )/(8* 127.2 )-( 48.27³)/(8* 127.2³)
= 1737.33 kgf/cm²

Bending at the Bottom of the Leg closest to the N.A. [S]:


= ( Vleg * Leglen / Smdwa )
= ( 108.8 * 870/14312 )
= 67.47 kgf/cm²

Allowable Bending Stress[Sb]:


= ( 0.6 * Fy * Occfac )
= ( 0.6 * 2531 * 1.333 )
= 2024.33 kgf/cm²
PV Elite 2019 SP2 Licensee 2
FileName : Seal Pot --------------------------------------
Leg Check, (Operating Case): Step: 17 9:45am Jan 15,2020

AISC Unity Check [Sc]( must be < or = to 1.00 ) :


= (Sma/Sa)+(0.85*S)/((1-Sma/Spex)*Sb)
= (8.362/1737 )+( 0.85 *67.47 )/(( 1 -8.362/6111 ) *2024 )
= 0.0332

Bolting Size Requirement for Leg Baseplates :

Baseplate Material SA-240 304


Baseplate Allowable Stress SBA 1407.13 kgf/cm²
Baseplate Length B 120.0000 mm
Baseplate Width D 120.0000 mm
Baseplate Thickness BTHK 10.0000 mm
Leg Dimension Along Baseplate Length d 0.0000 mm
Leg Dimension Along Baseplate Width b 0.0000 mm
Dist. from the Leg Edge to Bolt Hole Center z 15.0000 mm
Bolt Material SA-193 B7
Bolt Allowable Tensile Stress STBA 1753.82 kgf/cm²
Bolt Allowable Shear Stress SBShear 800.00 kgf/cm²
Anchor Bolt Nominal Diameter BOD 12.0000 mm
Number of Anchor Bolts in Tension per Leg NB 2
Total Number of Anchors Bolt per Leg NBT 4
Ultimate 28-day Concrete Strength FCPRIME 210.921 kgf/cm²

Baseplate analysis is performed for Angle, Beam & Pipe legs only.

PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2019


PV Elite 2019 SP2 Licensee: THE CULMINATES ENGG. SERVICES 3
FileName : Seal Pot --------------------------------------
Leg Check, (Filled w/Water): Step: 18 9:45am Jan 15,2020

RESULTS FOR LEGS : HydroTest Case Description: LEGS

Legs attached to: Shell

Section Properties : Sq/Rect Tubing BT50X50X6.3

European Structural Steel Data

Overall Leg Length 870.000 mm


Effective Leg Length Leglen 870.000 mm
Distance Leg Up Side of Vessel 0.000 mm
Number of Legs Nleg 2
Cross Sectional Area for BT50X50X6.3 Aleg 1101.238 mm²
Section Inertia ( strong axis ) 357787.219 mm**4
Section Inertia ( weak axis ) 357787.219 mm**4
Section Modulus ( strong axis ) 14311.658 mm ³
Section Modulus ( weak axis ) 14311.658 mm ³
Radius of Gyration ( strong axis ) 18.025 mm
Radius of Gyration ( weak axis ) 18.025 mm

Leg Orientation - Weak Axis

Overturning Moment at top of Legs 30.7 N-m


Total Weight Load at top of Legs W 579.2 N
Total Shear force at top of Legs 91.3 N
Additional force in Leg due to Bracing Fadd 0.0 N
Occasional Load Factor Occfac 1.333
Effective Leg End Condition Factor k 1.000

Note: The Legs are Not Cross Braced


The Leg Shear Force includes Wind and Seismic Effects

Maximum Shear at top of one Leg [Vleg]:


= ( max( Wind, Seismic ) + applied forces )( Imax / Itot )
= ( 91.27 )( 357791/715582 )
= 45.63 N

Axial Compression, Leg furthest from the Neutral Axis [Sma]:


= W/Nleg + (Mleg/(Nlegm*Rn))/Aleg
= 579.2/2 + (30706/( 1 * 109.1 ))/1101
= 5.29 kgf/cm²

Axial Compression, Leg closest to the Neutral Axis [Sva]:


= ( W / Nleg ) / Aleg
= ( 579.2/2 )/1101
= 2.68 kgf/cm²

Allowable Comp. for the Selected Leg (KL/r < Cc ) [Sa]:


= Occfac * ( 1-(kl/r)²/(2*Cc²))*Fy /
( 5/3+3*(Kl/r)/(8*Cc)-(Kl/r³)/(8*Cc³)
= 1.333 * ( 1-( 48.27 )²/(2 * 127.2² )) * 2531/
( 5/3+3*( 48.27 )/(8* 127.2 )-( 48.27³)/(8* 127.2³)
= 1737.33 kgf/cm²

Bending at the Bottom of the Leg closest to the N.A. [S]:


= ( Vleg * Leglen / Smdwa )
= ( 45.63 * 870/14312 )
= 28.29 kgf/cm²

Allowable Bending Stress[Sb]:


= ( 0.6 * Fy * Occfac )
= ( 0.6 * 2531 * 1.333 )
= 2024.33 kgf/cm²
PV Elite 2019 SP2 Licensee: THE CULMINATES ENGG. SERVICES 4
FileName : Seal Pot --------------------------------------
Leg Check, (Filled w/Water): Step: 18 9:45am Jan 15,2020

AISC Unity Check [Sc]( must be < or = to 1.00 ) :


= (Sma/Sa)+(0.85*S)/((1-Sma/Spex)*Sb)
= (5.287/1737 )+( 0.85 *28.29 )/(( 1 -5.287/6111 ) *2024 )
= 0.0149

Bolting Size Requirement for Leg Baseplates :

Baseplate Material SA-240 304


Baseplate Allowable Stress SBA 1407.13 kgf/cm²
Baseplate Length B 120.0000 mm
Baseplate Width D 120.0000 mm
Baseplate Thickness BTHK 10.0000 mm
Leg Dimension Along Baseplate Length d 0.0000 mm
Leg Dimension Along Baseplate Width b 0.0000 mm
Dist. from the Leg Edge to Bolt Hole Center z 15.0000 mm
Bolt Material SA-193 B7
Bolt Allowable Tensile Stress STBA 1753.82 kgf/cm²
Bolt Allowable Shear Stress SBShear 800.00 kgf/cm²
Anchor Bolt Nominal Diameter BOD 12.0000 mm
Number of Anchor Bolts in Tension per Leg NB 2
Total Number of Anchors Bolt per Leg NBT 4
Ultimate 28-day Concrete Strength FCPRIME 210.921 kgf/cm²

Baseplate analysis is performed for Angle, Beam & Pipe legs only.

PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2019