How to Post a Ticket against Nomination

 Oil and Gas Add to favorites

Purpose

This Document demonstrates the use of FM OIJ02_CREATE_TICKT with the latest release [ I am using
mySAP ECC 6.0 EHP 6 ].

And also demonstrates the use of OIJB_TKT_QCI_INTERFACE for quantity conversion parameters of SAP IS

Oil.

No documentation is available for this FM in SAP.

The FM is used to post ticket against nomination and encapsulates the entire functionality into one [Earlier

we needed 3 FM calls to achive the same].

Transactions

O4NSN & O4TGN for display of Nomination and Ticket.

How to achieve :

DATA : lw_tkt_h TYPE roij_el_ticket_hvb,



lw_tkt_si TYPE roijnomsubitems_io,

lw_oijnomh TYPE oijnomh,

lw_oijnomi TYPE oijnomi,

lw_return TYPE bapiret2,

lw_act_flag TYPE c VALUE ‘X’,

lw_tcount TYPE n LENGTH 4,

lw_i_o1 TYPE roij_el_tkt_i_o1,

lw_i_o2 TYPE roij_el_tkt_i_o2vb,

lt_tkt_i TYPE TABLE OF roij_el_ticket_i_io,

lw_tkt_i TYPE roij_el_ticket_ivb,

lt_tkt_si TYPE TABLE OF roijnomsubitems_io,

lt_i_o1 TYPE TABLE OF roij_el_tkt_i_o1,

lt_i_o2 TYPE TABLE OF roij_el_tkt_i_o2vb,


lt_return TYPE TABLE OF bapiret2.

Get the Nomination Details.

SELECT SINGLE * FROM oijnomh INTO lw_oijnomh

WHERE nomtk = lw_g_odet-nomtk.

SELECT SINGLE * FROM oijnomi INTO lw_oijnomi

WHERE nomtk = lw_g_odet-nomtk

AND nomit = lw_g_odet-nomit.

Pass the values to the corresponding structure.

SELECT COUNT(*) INTO lw_tcount FROM oij_el_ticket_i

WHERE nomtk = lw_g_odet-nomtk

AND nomit = lw_g_odet-nomit.

lw_tkt_h-tplst = lw_oijnomh-tplst.

lw_tkt_h-tsyst = lw_oijnomh-tsyst.

lw_tkt_h-erdat = sy-datum.

lw_tkt_h-erzeit = sy-uzeit.

lw_tkt_h-ernam = sy-uname.


ADD 1 TO lw_tcount.

CALL FUNCTION ‘CONVERSION_EXIT_ALPHA_OUTPUT’

EXPORTING

input = lw_g_odet-nomtk

IMPORTING

output = lw_tkt_h-ticketnr.

* External Ticket Identifier

CONCATENATE lw_tkt_h-ticketnr

lw_g_odet-nomit+7(3)

lw_tcount

INTO lw_tkt_h-ticketnr

SEPARATED BY ‘_’.

lw_tkt_h-ticket_type = ‘YRT’.

lw_tkt_h-ticket_version = 00.

lw_tkt_h-ticket_purpose = 01.

lw_tkt_h-updkz = ‘I’.

* Populating the Item table for ticket posting



lw_tkt_i-nomtk = lw_g_odet-nomtk.

lw_tkt_i-nomit = lw_g_odet-nomit.

This indicator is to be passed if you want to close the nomination line item

* lw_tkt_i-close_nomit = ‘X’.

lw_tkt_i-vehicle = lw_g_odet-vehid.

lw_tkt_i-nomnr = lw_oijnomh-nomnr.
lw_tkt_i-matnr = lw_oijnomi-matnr_i.

lw_tkt_i-locid = lw_oijnomi-locid.

lw_tkt_i-substatus = lw_oijnomi-isubstat.

lw_tkt_i-sityp = lw_oijnomi-sityp.

lw_tkt_i-charg_l = lw_oijnomi-charg_l.

lw_tkt_i-charg_d = lw_oijnomi-charg_d.

lw_tkt_i-charg_o = lw_oijnomi-charg_o.

The scenario is the identifier which states whether the process is outbound or inbound

Depending on this the Source Plant / SLoc or Destination Plant / Sloc is filled.

SELECT SINGLE mvscenario FROM toij_el_mvscen

INTO lw_tkt_i-mvscenario 
WHERE sityp = lw_oijnomi-sityp

AND docind = lw_oijnomi-docind

AND book_transfer = space.

IF p_omode = 7.

lw_tkt_i-werks_o = lw_oijnomi-locpt.

lw_tkt_i-lgort_o = lw_oijnomi-locsl.

ELSEIF p_omode = 3.

lw_tkt_i-werks_d = lw_oijnomi-locpt.

lw_tkt_i-lgort_d = lw_oijnomi-locsl.

ENDIF.

lw_tkt_i-time_st_led_ot = lw_tkt_i-time_st_load_sta.

lw_tkt_i-ticket_item = 10.
lw_tkt_i-ticket_version = 00.

lw_tkt_i-ticket_purpose = 01.

lw_tkt_i-updkz = ‘I’.

CONCATENATE sy-datum sy-uzeit INTO lw_tkt_i-time_st_load_sta.

lw_tkt_i-oib_bltime = sy-uzeit + ‘000001’. 


CONCATENATE sy-datum lw_tkt_i-oib_bltime INTO lw_tkt_i-time_st_load_end.

IF sy-uzeit LT ‘060000’.

lw_tkt_i-budat = sy-datum – 1.

lw_tkt_i-oib_bltime = ‘115500’.

ELSE.

lw_tkt_i-budat = sy-datum.

lw_tkt_i-oib_bltime = sy-uzeit.

ENDIF.

If you are using sub-items as in my case is a rail scenario so I am passing the sub-items as well

It is not a mandatory parameter, as in Vessel case there won’t be any so it can be skipped.

LOOP AT lt_subitems ASSIGNING <lfs_item>.

IF <lfs_item>-subitm_actqty IS NOT INITIAL


AND <lfs_item>-carr_tkt_key IS INITIAL.

<lfs_item>-ticket_item = lw_tkt_i-ticket_item.

<lfs_item>-ticket_version = lw_tkt_i-ticket_version.
<lfs_item>-ticket_purpose = lw_tkt_h-ticket_purpose.


<lfs_item>-act_date = sy-datum.

<lfs_item>-act_time = sy-uzeit.

MOVE-CORRESPONDING <lfs_item> TO lw_tkt_si. “#EC ENHOK

lw_tkt_si-updkz = ‘U’.

APPEND lw_tkt_si TO lt_tkt_si.

lw_tkt_i-menge = lw_tkt_i-menge + <lfs_item>-subitm_actqty.

lw_tkt_i-meins = <lfs_item>-subitm_actuom.

IF <lfs_item>-zz_dip_temp IS NOT INITIAL.


IF lw_tkt_i-tstmp IS INITIAL.

lw_tkt_i-tstmp = <lfs_item>-zz_dip_temp .
ELSE.

lw_tkt_i-tstmp = ( lw_tkt_i-tstmp + <lfs_item>-zz_dip_temp ) / 2.


ENDIF.

ENDIF.

IF <lfs_item>-zz_dip_den IS NOT INITIAL.

IF lw_tkt_i-tdich IS INITIAL.
lw_tkt_i-tdich = <lfs_item>-zz_dip_den. 
ELSE.
lw_tkt_i-tdich = ( lw_tkt_i-tdich + <lfs_item>-zz_dip_den ) / 2.

ENDIF.
ENDIF.

ENDIF.

ENDLOOP.

IF lt_tkt_si IS INITIAL.

MESSAGE text-050 TYPE ‘I’.


RETURN.

ENDIF.

APPEND lw_tkt_i TO lt_tkt_i.

The QCI parameters are an important part of the entire IS-Oil scenario so for that conversion the below
FM is used.

CALL FUNCTION ‘OIJB_TKT_QCI_INTERFACE’

EXPORTING
is_working = ‘H’

is_ticket_header = lw_tkt_h 
is_ticket_item = lw_tkt_i
is_nomination_header = lw_oijnomh
is_nomination_item = lw_oijnomi

CHANGING
cs_oij_el_tkt_i_o1 = lw_i_o1

ct_oij_el_tkt_i_o2 = lt_i_o2
return = lt_return

EXCEPTIONS
ticket_item_unit_error = 1

OTHERS = 2.

IF sy-subrc <> 0.

IF sy-msgid IS INITIAL.
MESSAGE i016(rp) WITH text-e03 .

ELSE.
MESSAGE ID sy-msgid TYPE ‘I’ NUMBER sy-msgno

WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.


ENDIF.

CLEAR lw_act_flag.
ENDIF.

The ACT flag for the actualization of the ticket if you want to actualize it later keep it blank.

CHECK lw_act_flag EQ ‘X’.

This is an important part… In my case I am not passing the QCI Defaults so If we are changing the

defaults

The manual indicator needs to be flagged.

lw_i_o1-mttmp = lw_tkt_i-tstmp.

lw_i_o1-tdich = lw_tkt_i-tdich.

lw_i_o2-manen = ‘X’.
MODIFY lt_i_o2 FROM lw_i_o2 TRANSPORTING manen WHERE manen = space .

APPEND lw_i_o1 TO lt_i_o1.

The below sort is compulsory as without it internally some read fails

SORT lt_i_o2 BY ticket_key ticket_item

ticket_version ticket_purpose msehi.

CALL FUNCTION ‘OIJ02_CREATE_TICKT’

EXPORTING

flag_actualization = lw_act_flag
CHANGING

gs_h = lw_tkt_h
gt_i = lt_tkt_i

gt_si = lt_tkt_si
gt_i_o2 = lt_i_o2

gt_i_o1 = lt_i_o1
lt_bapi_return = lt_return.

READ TABLE lt_return INTO lw_return WITH KEY number = ‘850’


type = ‘S’.

IF sy-subrc IS NOT INITIAL.

READ TABLE lt_return INTO lw_return WITH KEY type = ‘E’.


ROLLBACK WORK.
ELSE.

COMMIT WORK AND WAIT.


ENDIF.

IF lw_return IS NOT INITIAL.

MESSAGE ID lw_return-id

TYPE lw_return-type

NUMBER lw_return-number
WITH lw_return-message_v1 lw_return-message_v2.

ENDIF.

Would you like to access Full Article?

If you are already a member in this website, Please Click here to login If you are not yet a member, Please

Click here to Sign up  


if you have any questions don't hesitate to contact us from the Button bellow

 Contact US

New NetWeaver Information at SAP.com


Very Helpfull

User Rating: Be the first one !


Das könnte Ihnen auch gefallen