M 32.0 kNm fcu 25 N/mm² gc = 1.50 M 32.0 kNm fcu 25 N/mm² g c = 1.50 ßb 1.00 fy 435 N/mm² gs = 1.15 ßb 1.00 fy 435 N/mm² g s = 1.15 span 4100 mm steel class A span 4100 mm steel class A h 400 mm Comp cover 35 mm to main reinforcement h 400 mm Comp cover 35 mm to main reinforcement bw 200 mm Tens cover 35 mm to main reinforcement bw 200 mm Tens cover 35 mm to main reinforcement bf 487 mm Side cover 40 mm to main reinforcement bf 200 mm Side cover 40 mm to main reinforcement INTERIOR SPAN SUPPORT hf 130 mm Section location hf 130 mm Section location Tens Ø 12 mm Section shape L BEAM Tens Ø 12 mm Section shape L BEAM Top steel 2 no & Ø 12 . Top steel 2 no & Ø 12 .
fcu = 25 N/mm² gc = 1.50 d b fcu = 25 N/mm² gc = 1.50 d b fyl = 245 N/mm² gs = 1.15 359 200 fyl = 245 N/mm² gs = 1.15 359 200 steel class A steel class A 2 Main Steel Link Legs Side cover Shear V UDL Main Steel Link Legs Side cover Shear V UDL 3 12 6 2 40 31.5 19.0 3 12 6 2 40 45.0 19.0 No mm Ø mm Ø No mm kN kN/m No mm Ø mm Ø No mm kN kN/m
OUTPUT B (MID) OUTPUT B (END)
As = 339 N/mm² = 0.473% As = 339 N/mm² = 0.473% (Eqn 3) 2 (Eqn 3) v = 45.0 x 10³ /200 /359 = 0.627 N/mm² (Table 3.8) vc = 0.506 N/mm², from table 3.8 (Table 3.8) vc = 0.506 N/mm², from table 3.8 (v - vc)bv = 80.0 N/mm = nominal (v - vc)bv = 80.0 N/mm = nominal PROVIDE 2 legs R6 @ 150 = 80.3 N/mm PROVIDE 2 legs R6 @ 150 = 80.3 N/mm (nominal) (nominal) . .