Series DW

2 Port Solenoid Valve


DW
�WIDER RANGE OF OPERATING PRESSURE
0 ~ 7 kgf/cm2(DW03) DV100
2
0.3~7 kgf/cm (DW10,15) DV1000∙
0.3 ~ 10 kgf/cm2(DW20, 25) 3000∙4000
�HIGH FLOW CAPACITY DS300
�LOW VOLTAGE SOLENOID
�CAN BE MOUNTED ANY WHERE DS3000

DS5000
Symbol
Direct Acting Type Air Pilot Type DS2000
(N. C.) (N. C.)
DX2R
OUT OUT
DP300∙
3000∙5000
IN IN DS6000

DX2
How to Order
DM
DW 10 1 C 01 VC
DH
1 2 3 4 5 6 7
DT220
� 2 Port Solenoid Valve
Applicable Fluid (Water, Air, Oil) Standard Specifications
※Option:Steam DC
Applicable Air, Water, Oil
� Body(Orifice Size) Proof Pressure 1.5MPa(213.35psi)
03 : ф2.5-Direct Type Solenoid
10 : ф10 Fluid Temperature 0~70�
C(32。
F~158。
F)
15 : ф15 Pilot Type Solenoid
Ambient and fluid temperatare Max. 60�
C(140。
F)
20 : ф20
25 : ф25 Electrical Entry Grommet, Conduit

� Voltage Actuation Type Direct or Pilot Solenoid


1 : AC100V, 50/60㎐ Valve Type Normal Close
2 : AC200V, 50/60㎐
5 : DC24V Seat Type Poppet
9 : Others AC (50/60㎐) 100V, 200V
Rated Voltage
� Electric Connection DC 24V
G : Grommet (only Rc(PT) 1/8) Allowance Voltage Range Rated Voltage ±10%
C : Conduit
Coil Insulation Class B or Equivalent 110�
C(230。
F)
� Port Size Rc(PT)
Inrush 17VA (60㎐)
01 : 1/8 Power AC
02 : 1/4 Holding 15VA (60㎐)
03 : 3/8 Consumption
04 : 1/2 DC 11W
06 : 3/4
10 : 1

� Blank : Standard
S : SUS Type

� VC : Vacuum Type(-100kpa)
(only AC Voltage)

B-3 PNEUMATICS
Series DW

Applicable Specifications

AC110, 220V(50/60㎐)
Coil Apparent Power
DC 6, 12V
Body Material Stainless steel(SCS13)
H Class(180�
C)(356。
F)
Coil Insulation
AC100, 110, 200, 220V Only

Model

Port Orifice Size Effective Weight


Type Pressure Orifice
(Size) (фmm) (mm2) (kgf)
DW03-�
G-0`1 1/8(6A) .5 6 0.3
0~0.7MPa (0~99.5psi)
DW03-�
G-0`2 1/4(8A) 2.5 6 0.3
DW10-�
C-0`2 1/4(8A) AC: DC: 10 34 0.5
DW10-�
C-0`3 3/8(10A) 0~1MPa 0.03~0.7MPa 10 43 0.5
(0~140.2psi) (4.27~99.5psi)
DW15-�
C-0`4 1/2(15A) 15 160 0.7
DW20-�
C-0`6 3/4(20A) 20 170 0.9
0.03~1MPa (4.27~140.2psi)
DW25-�
C-10 1(25A) 25 225 1.2

Dimensions mm(inch)

01
DW � 03 - � G -
02
250(9.84)

Symbol

OUT
Port Size
59(2.32)

(PT1/8”
, 1/4”
)

IN
25(0.98)

9.5(0.37)

35(1.38) 26(1.02)
18(0.71)

2-M5×0.8

PNEUMATICS
B-4
Series DW
Dimensions mm(inch)

DW 10 - � C- 02
03
38(1.50) 250(9.84)
DW
Symbol

OUT DV100
DV1000∙
3000∙4000

96(3.78)
IN
PF 1/2 Port Size DS300

70(2.76)
(PT1/4”
, 3/8”
)

DS3000

DS5000
50(1.97)
DS2000
26(1.02) 2-M4×0.7
DX2R
DP300∙
26(1.02)

3000∙5000

(1.02)
26
DS6000
2-M6×1.0
DX2

DM
Dimensions mm(inch)
DH

DW15 - � C - 04
DT220
7)
1.7
5(ф DC
ф4

Symbol
OUT

50(1.99)
IN

38(1.50) 250(9.84)
103(4.06)

PF1/2
77(3.03)
14.5(0.57)

Port Size
(PT1/2”
)

66.5(2.62) 29(1.14)
50(1.97)

B-5 PNEUMATICS
Series DW
Dimensions mm(inch)

DW 20 - �C - 06
DW 25 - �C - 10

)
1.77
Symbol


ф45
OUT

65(2.56)
IN

38(1.5) (250[9.84])

PF1/2

122(4.8)
96(3.78)
Port Size
(PT3/4”
, 1”
)

21(0.83)
92(3.62) 42(1.65)
57.5(2.26)
65(2.56)

Precautions

Piping Wiring
� Piping should be thoroughly flushed to � The minimum diameter for wire connection
remove sludge, cutting oil, and dust. is 0.5mm2 .
� During piping and coupling connection, care � An electric circuit which prevents chattering
should be taken to prevent contamination by at the point of contact should be employed.
cut thread chips or sealing materials.(When � When the electric is apt to be damaged by
applying sealing tape to threads, one screw surge voltage, place a surge suppressor in
thread should extend beyond the tape.) parallel with the solenoid voltage suppressor
� Pay attention to the piping direction(IN, (option).
OUT). IN or other marks are indicated on the � The allowable voltage range is -10%~+10%
inlet side. of the rated voltage. However, if great
� The coil should not be subjected to an response is desired for DC power, the
extended force. When tightening, apply a voltage range should be within ±5% of the
wrench to the outside of the pipe mounting rated voltage. Voltage drop is measured at a
area only. part of the lead wire connected to the coil.
� The piping system should not be grounded. � The voltage found on both ends of the coil,
Grounding would cause electrolytic corrosion. when it deenergizes, is:AC:20% or less of
� To prevent collection of fluid within the the rated voltage DC:2% or less of the rated
piping circuit, install a relief valve within the voltage
circuit. The DC value is for a temperature of 20±5℃.
At lower temperatures, the DC value will be
lower.

PNEUMATICS
B-6
Series DW

Mounting Applicable Fluid


� The solenoid valve may be mounted in any � Fluid Classification
orientation. When selecting a valve for your application,
When mounted upside down, however, ensure the compatibility of the fluid and DW
foreign material in the fluid is liable to valve materials. Generally, the recommended
adhere to the iron core. Avoid such a viscosity of fluid is 50cSt max. DV100
mounting method. Mount the valve with its For futher details, contact our representative.
DV1000∙
coil facing up. 〈Reference〉Standard materials 3000∙4000
� Do not keep coil assemblies warm with Body:Brass or BC6 Seal:NBR, Coil:Insulation
insulating material, etc. It will cause the coil Type B. DS300
to burn out. Antifreezing tape, heater, etc., These are for water, air, and oil use. For
should be applied to piping and body areas materials other than standard, refer to the DS3000
only. “Option list”and“Applicable fluid check list.”
� Do not place the valve in areas of severe The specifications may be slightly different. DS5000
vibration. If it is unavoidable, shorten the
arm to a minimum to avoid resonance. � Fluid Quality
DS2000
Fluid mixed with foreign material can
promote wear of the valve seat and iron
DX2R
core. Adhesion of foreign particles to the iron
Storage core and sliding section can cause degraded DP300∙
function of the valve or sealing trouble. To 3000∙5000
Long time storage after using the valve for prevent this, place a filter(strainer)immediately
water will require complete removal of moisture in front of the solenoid valve. In general, a DS6000
in order to prevent corrosion and deterioration mesh of 80~100 is recommended.
of rubber parts. � Lubricant DX2
Our solenoid valves do not need lubrication.
However, lubricated air will increase their DM
life.
Long Period Energization or Deenergization � In using inflammable oil and gas, prevention DH
of leakage both inside and outside of the
The valve switching period depends on the type
valve should be exercised. DT220
and quality of the fluid. When pure water is
� In case oil and other impurities are not
taken as a standard, the valve should be
allowed in the fluid, use nonlube treated
switched at least once every 10 days. If the DC
parts.
cycle is greater than 10 days, a system check
� Under conditions near the limit of valve
mechanism should be installed. The valve is not
operation, the option and fluid may not be
intended to be used as an emergency Circuit
applicable as they are since only general
breaker Specify operational conditions for use
applications are shown, check actual
under conditions similar to that.
conditions on your own for appropriate
selection.

Fluid Temperature
Refer to the temperature range for each model.
The temperature range changes according to
the sealing material, coil insulation, power,
supply, etc. Contact our representative for use
other than standard use.

B-7 PNEUMATICS