Sie sind auf Seite 1von 11

External Alarms

External Alarms from a Site may be collected by using External


Alarm cables originating from the alarm sensors via the krone
block.

FlexiEDGE or FlexiWCDMA may be used for Alarm


configuration.

External alarms need to be defined in the BSC if FlexiEDGE is


used.

External Alarms need to be defined at the NodeB if


FlexiWCDMA is used for external alarm monitoring.

Soc Classification level


1 © Nokia Siemens Networks Abdul Hameed Althaf +966503278654
FSAA ..External Alarm cable for FlexiBTS (12
Alarms).For >12 use special alarm box.

D 37 Female
36 pole MDR male

Soc Classification level


2 © Nokia Siemens Networks Abdul Hameed Althaf +966503278654
FSAA cable pinout and alarm pairs

AL-1
AL-2
AL-3
AL-4
AL-5
AL-6
AL-7
AL-8
AL-9
AL-10
AL-11
AL-12

Soc Classification level


3 © Nokia Siemens Networks Abdul Hameed Althaf +966503278654
FlexiBTS EAC Pinouts for reference.

Soc Classification level


4 © Nokia Siemens Networks Abdul Hameed Althaf +966503278654
Option1: Remove the D37 Female Connector and Punch
all the cables pairs to the DDF as per the color codes

Cable pair 6
to
Cable Pair 17
are used for
External alarms
1 to 12.

Soc Classification level


5 © Nokia Siemens Networks Abdul Hameed Althaf +966503278654
Option 2: Connect the Ultrasite Alarm cable from Krone to
the FSAA.

Soc Classification level


6 © Nokia Siemens Networks Abdul Hameed Althaf +966503278654
ZAIN Project uses external alarms in FlexiEDGE
BTS/UltraMini
EAC connector pin assignment for NON GREENFIELD/METRO/ROOFTOP Sites

Signal Pin Pin Signal Alarm Description

EXT_AL 1 7 25 GND Shelter Door Open / Movement Sensor

EXT_AL 2 8 26 GND Fire Alarm/Sensor

EXT_AL 3 9 27 GND Aircon Failure / High Temp

EXT_AL 4 10 28 GND Aircraft Warning Light

EXT_AL 5 11 29 GND Rectifer AC power Failure

EXT_AL 6 12 30 GND Rectifier Module Failure

EXT_AL 7 13 31 GND Low Battery Voltage

EXT_AL 8 14 32 GND Undervoltage / Overvoltage from MDB

EXT_AL 9 15 33 GND Commerial Power Failure

EXT_AL 10 16 34 GND Reserved for Transmission

EXT_AL 11 17 35 GND Reserved for Transmission

EXT_AL 12 18 36 GND Reserved for Transmission

Soc Classification level


7 © Nokia Siemens Networks Abdul Hameed Althaf +966503278654
ZAIN Project uses external alarms in FlexiEDGE
BTS/UltraMini
EAC connector pin assignment for GREENFIELD Sites

Signal Pin Pin Signal Alarm Description

EXT_AL 1 7 25 GND Shelter Door Open / Movement Sensor

EXT_AL 2 8 26 GND Fire Alarm/Sensor

EXT_AL 3 9 27 GND Aircon Failure / High Temp

EXT_AL 4 10 28 GND Aircraft Warning Light

EXT_AL 5 11 29 GND Rectifer AC power Failure

EXT_AL 6 12 30 GND Rectifier Module Failure

EXT_AL 7 13 31 GND Low Battery Voltage

EXT_AL 8 14 32 GND Undervoltage / Overvoltage from MDB

EXT_AL 9 15 33 GND Commerial Power Failure

EXT_AL 10 16 34 GND Low Fuel Alarm for Generator

EXT_AL 11 17 35 GND Generator not in Auto Mode

EXT_AL 12 18 36 GND Generator Failure

Soc Classification level


8 © Nokia Siemens Networks Abdul Hameed Althaf +966503278654
FlexiEDGE External Alarm Test:

Connect the FSAA to the EAC port of the ESMA.


Connect the other end of the FSAA to the Krone -AlarmSensors
Alarms are defined in the BSC including the no: name:polarity.
Simulate alarm and observe them at the BTS and at the BSC.

Soc Classification level


9 © Nokia Siemens Networks Abdul Hameed Althaf +966503278654
FlexiWCDMA Alarm Test.--Create Alarms in NodeB.
FSAA is connected to EAC port of FSMB.

Normally closed:
Alarms are active as long as
There is break in path of
voltage flow.
Put a loop to make alarm off

Soc Classification level


10 © Nokia Siemens Networks Abdul Hameed Althaf +966503278654
FlexiWCDMA External Alarm test:Alarm status
from BTS Manager

Alarm 1,7,12 are OFF


Other alarms are active.

Alarm CABLE Pair 6,12 and 17 are loop ie


Alarm is off