RE 92 202/07.95
Variable Displacement Pump A7VO replaces: 01.91
Sizes 55...160
Series 6
Nominal Pressure 350 bar
Peak Pressure 400 bar
Index Features
Mode of operation
Pump in open circuit O
Sizes
Displacement Vg max in cm3 55 80 107 160 250 355 500 1000
Sizes 250, 355, 500, 1000 see RE 92203
= Preferred program
RE 92 202/07.95 | A7VO Mobile Hydraulics | Bosch Rexroth AG 3/20
A7V O / 6 3 – Z B 01
Mode of operation
Sizes
Series
6
Index
3
Seals
NBR - nitril caoutchouc / shaft seal FPM N
FPM - flour caoutchouc V
Shaft end
splined DIN 5480 Z
Mounting flange
ISO 4-hole B
Technical Data
Hydraulic fluid
We request that before starting a project detailed information Example: At an ambient temperature of X°, the operating
about the choise of hydraulic fluids and application conditions temperature in the tank is 60°C. In the optimum viscosity range νopt
are taken from our catalogue sheets RE 90220 (mineral oil), RE (shaded area), this corresponds to viscosity grades VG 46 or VG
90221 (environmentally acceptable hydraulic fluids) and RE 68, VG 68 should be selected.
90223 (fire resistant fluids, HF). Important: The leakage fluid temperature is influenced by
When using HF fluids or environmentally acceptable hydraulic pressure and speed and is typically higher than the tank
fluids respectively possible limitations for the technical data temperature. However, maximum temperature at any point in
have been taken into consideration. If necessary please contact the system must be less than 115°C.
our technical department (please indicate type of the hydraulic If the above conditions cannot be met due to extreme operating
fluid used in your application when ordering). conditions, or with a high ambient temperature, we recommend
that port U be used for bearing flushing.
Operating viscosity range
Flushing flow Size 55 80 107 160
We recommend that the operating viscosity (at operating
temperature), for both efficiency and life of the unit, be chosen qV Sp L/min 4 6 8 12
within the optimum range of: Temperature of flushing fluid ≤ tank temperature
νopt = opt. operating viscosity 16...36 mm2/s
Filtration of fluid
referred to tank temperature at open circuit. The finer the filtration the better the achieved purity grade of the
pressure fluid and the longer the life of the axial piston unit.
Viscosity limits To ensure the functioning of the axial piston unit a minimum
The limiting values for viscosity are as follows: purity grade of:
νmin = 5 mm2/s, 9 to NAS 1638
short term at a max. permissible temp. of tmax = 115°C. 6 to SAE
Please note that the max. fluid temperature of 115°C is also not 18/15 to ISO/DIS 4406 is necessary.
exceeded in certain areas (for instance bearing area). At very high temperatures of the hydraulic fluid (90°C to max.
νmax = 1600 mm2/s, 115°C) at least cleanless class
short term on cold start, tmin = -40°C. 8 to NAS 1638
At temperatures of -25°C up to -40°C special measures may be 5 to SAE
required for certain installation positions. Please contact us for 17/14 to ISO/DIS 4406 is necessary.
further information.
If above mentioned grades cannot be maintained please consult
us.
Selection diagram
2500-40° -20° 0° 20° 40° 60° 80° 100° Direction of flow
1600 1600
1000 Clockwise rotation Counter-clockwise rotation
600 S to B S to A
400
mm 2 /s
V 68
VG
V 32
V 46
V 2
200
G
G
G
G
10
Installation position
2
100
Optional. The pump housing must be filled with fluid prior to
60
in
are necessary.
20 ;;;;;;;;;;;;
;;;;;;;;;;;;
νopt.
Viscosity
Technical Data
Pump drive
Radial and axial loading on the drive shaft
The values shown are maximum values and are not permitted for continuous operation.
Size 55 80 107 160
a mm 17,5 20 22,5 25
Fq max N 9280 11657 13580 18062
Fq/bar N/bar 23,2 29,1 34,0 45,2
± Fax max N 500 710 900 1120
± Fax zul./bar N/bar 7,5 9,6 11,3 15,1
Code explanation
Fq
a = distance of Fq from shaft shoulder ±Fax max = max. permissible axial force when
stationary or when axial piston unit is
Fq max = max. occurring radial force a running at zero pressure
Fq/bar = radial force / bar working pressure
±Fax zul./bar = permissible axial bar working pressure
at gear drive (DIN 867) with smallest PCD of pinion
DR min and Vg max (DR min = 2,5 x dia. of drive shaft) The direction of the max. permissible axial force must be noted:
= preload required / bar working pressure − Fax max = increases bearing life –
(radial force) to transmit torque at V-belt drive (DIN Fax
+ Fax max = reduces bearing life +
7753) with smallest pulley diameter DK min and
Vg max (DK min = 5 x dia. of drive shaft) (avoid if possible)
Table of values (theoretical values, without considering mech-hyd. and volumetric efficiency; values rounded)
Size 55 80 107 160
Displacement Vg max cm3 54,8 80 107 160
Vg min cm3 0 0 0 0
Max. speed 1) at Vg max nmax 1 rpm 2500 2240 2150 1900
at Vg < Vg max
nmax 2 rpm 3400 3000 2900 2560
(see diagram)
Max. perm. speed (speed limit) with increased
inlet pressure pabs at suction nmax zul. rpm 3750 3350 3200 2850
inlet S (see diagram)
Max. perm flow 2) at nmax 1 (Vg max) qV max 1 L/min 133 174 223 295
Max. power (∆p = 350 bar) at qV max 1 Pmax 1 kW 80 105 134 177
Torque constants at Vg max Tk Nm/bar 0,87 1,27 1,70 2,55
Perm. torque at Vg max at continuous operation
Tn Nm 305 446 596 891
(∆p = 350 bar)
max. perm., short-term
Tmax Nm 348 510 681 1018
(∆p = 400 bar)
Moment of inertia about the drive axis J kgm2 0,0042 0,0080 0,0127 0,0253
Weight (approx.) m kg 25 40 49 71
1) The values shown are valid for an absolute pressure (pabs) of 1 bar at the suction inlet S and when operated on mineral oil.
By increasing the inlet pressure (pabs > 1 bar) the speed may be increased to the max. permissible speed (speed limit), see
diagram.
2) 3 % flow losses included.
Calculation of Size
Vg • n • ηv Vg = geom. displacement per rev. in cm3
Flow qV = in L/min
1000 T = torque in Nm
∆p = differential pressure in bar
Vg • ∆p 1,59 • Vg • ∆p
Drive torque T = = in Nm n = speed in rpm
20 • π • ηmh 100 • ηmh
ηv = volumetric efficiency
2π•T•n T•n qV • ∆p ηmh = mech-hyd. efficiency
Drive power P = = = in kW ηt = overall efficiency (ηt = ηv • ηmh)
60 000 9549 600 • ηt
n 2560
1,6
n max 1
= = 1,14
1,5 nmax 1 2240
1,2
1,4
Speed n
The constant power control controls the output volume of the Variation: Remote pressure cut-off (G)
pump in relation to the working pressure so that, at a constant A sequence valve with subplate takes over the function of the
drive speed, the preset drive power is not exceeded. pressure cut-off. The valve is mounted separate from the pump,
and the simple piping length should not exceed 5 m. High
pB • Vg = constant pressure is supplied from the pump to the valve via port A1, and
the valve control oil is fed back to the pump via port X3, causing
pB = working pressure, Vg = pump displacement the pump to swivel back towards Vg min. Port T of the sequence
valve and T1, the pilot drain from the pump must be connected
back to tank (cooler).
350
Setting range from 50 bar to 315 bar
300
250 Any pressure relief valve included in the circuit to limit the max.
Working pressure pB in bar
power setting.
Should the working pressure exceed the set spring force, the
Setting range
pilot control valve is operated via the rocker arm, allowing the
pump to swivel towards zero output. This in turn reduces the
effective moment on the arm of the rocker, thus allowing the
working pressure to rise in the same ratio by which the output
flow is reduced (pB • Vg = constant).
In unoperated (zero pressure) condition, the pump is swivelled
to its starting position (Vg max) by means of a control spring.
The start of control is adjustable from 50 bar to 220 bar. 50
min
The output power (performance curve) is influenced by the
efficiency of the pump. Vg min Displacement Vg max
A1 A/B R U
A
X3
T
S T1
X3
S T1
Unit dimensions LR / LRG
see pages 17...20
8/20 Bosch Rexroth AG | Mobile Hydraulics A7VO | RE 92 202/07.95
Variation: Integral pressure cut-off (fixed setting), (D) Unit dimensions LRD
general dimensions and connections see pages 17...20
The pressure cut-off is in effect a constant pressure control
which swivels the pump back to Vg min when the preset working
pressure is reached. U R T1
This function overrides the constant power control, i.e. the constant
A1
A1
power control is effective below the preset working pressure.
The valve is integrated into the control housing and is set in the X3
factory to a fixed pressure, within the range 200 bar to max.
350 bar. Y
Note, however, that the max. permissible setting between start
of control and pressure cut-off is start of control x 5.
Example: R
Start of control (constant power control): 50 bar
Max. setting of pressure cut-off: View Y
50 bar • 5 = 250 bar counter-clockwise rotation clockwise rotation
When T1 is plugged and Ttank ≤ 50°C the maximum duration of
A3
operation is ≤ 2 min.
Pressure cut-off (D)
Any pressure relief valve included in the circuit to limit the max.
pressure must be set to a cracking pressure at least 20 bar T1 A1 A1 T1
above the pressure control setting.
S X3 X3 S
Constant power
Working pressure pB in bar
control (LR)
Size A1 A2 A3
200 55 128 121 62
min
80 132 132 70
107 138 136 74
160 150 147 84
Circuit diagram
Constant power control with integral pressure cut-off
(fixed setting) LRD
A1 A/B R U
X3
S T1
RE 92 202/07.95 | A7VO Mobile Hydraulics | Bosch Rexroth AG 9/20
A3
ment is adjusted in relation to the pilot current. If the set flow or the
working pressure is such that the power curve is exceeded, the U R T1
constant power control overrides the stroke limiter and reduces A1
A4
displacement until the power hyperbola is restored.
X3
As the pilot current increases, the pump swivels to a lower
displacement.
Y
In unoperated (zero pressure) condition, the pump is swivelled
to its starting position (Vg max) by means of a control spring.
Start of control (at Vg max) ______________________ 200 mA R
End of control (at Vg min) ______________________ 600 mA
Control from Vg max to Vg min View Y
counter-clockwise rotation clockwise rotation
A5
800
700 Pressure
600 cut-off (D)
Pilot current I in mA
500 Y3 Y3
400
T1 A1 A1 T1
300
S X3 X3 S
200
100
Constant power
control (LR)
Circuit diagram:
Connections
Constant power control with pressure cut-off and
Y3 Remote control pressure M14x1,5 (plugged)
electrical stroke limiter, LRDU
A1 A/B R U Size A1 A2 A3 A4 A5
55 276 251 245 105 12
Y3 80 304 279 257 116 14
107 321 295 264 122 18
160 360 334 282 140 19
X3
S T1
10/20 Bosch Rexroth AG | Mobile Hydraulics A7VO | RE 92 202/07.95
30
U R T1
A4
25
A5
A1
A6
20 X3
Setting range
15
10 Y
4
R
0 0,2 0,4 0,6 0,8 1,0
View Y
Vg min Displacement Vg max counter-clockwise rotation clockwise rotation
A7 Pressure cut-off (D)
H5 ➔ pilot pressure increase (Vg max – Vg min) ____ ∆p = 10 bar X1
X1
40 Y3 Y3
35
T1 A1 A1 T1
Pilot pressure pSt in bar
30
S X3 X3 S
25
20
Setting range
15
10 A B
4
Constant power
0 0,2 0,4 0,6 0,8 1,0 Connections control(LR)
Vg min Displacement Vg max Y3 Remote control pressure M14x1,5 (plugged)
X1 Pilot pressure M14x1,5
A pressure of 40 bar is necessary to operate the control. The
required control oil is taken from the high pressure circuit. Size A1 A2 A3 A4 A5 A6 A7
If necessary, a boost pressure of ≥ 40 bar should be applied at 55 262 257 252 170 127 105 12
port Y3. 80 290 284 279 182 138 116 14
If the H-function is used for two-point switching control only
(Vg max - Vg min), pilot pressure at port X1 must not exceed 40 bar. 107 309 300 295 189 144 122 18
160 351 340 334 207 162 140 19
RE 92 202/07.95 | A7VO Mobile Hydraulics | Bosch Rexroth AG 11/20
40
35
Pilot pressure pSt in bar
30
S T1
25
20 Unit dimensions LRDH2, LRDH6
general dimensions and connections see pages 17...20
Setting range
15
10 A1
A2 (X1)
4 A3 (Y3)
A4
H6 ➔ pilot pressure increase (Vg min – Vg max) _______ ∆p = 10 bar
U R T1
A5
A6
A1
40 X3
35
Y
Pilot pressure pSt in bar
30
25
20 R
Setting range
15 View Y
counter-clockwise rotation clockwise rotation
10
A7 Pressure cut-off (D))
4
T1 A1 A1 T1
A pressure of 40 bar is necessary to operate the control. The X3 X3
S S
required control oil is taken from the high pressure circuit.
If necessary, a boost pressure of ≥ 40 bar should be applied at
port Y3.
If the H-function is used for two-point switching control only
(Vg min - Vg max), pilot pressure at port X1 must not exceed 40 bar. A B
The constant pressure control maintains the pressure in a Zero stroke operation
hydraulic system constant whithin its control range in spite of The standard pump unit is designed for intermittent constant
changing pump flow requirements. The variable pump supplies pressure operation.
only the volume of fluid required by the consumer. Should Short-term operation at zero stroke (< 10 min.; ∼50 % duty) is
working pressure exceed the set pressure, the pump is auto- permissible up to a working pressure pmax = 315 bar at a tank
matically swivelled back to a smaller angle and the deviation in temperature of ≤ 50°C.
control corrected. For long-term periods of zero stroke operation, port U should
In unoperated (zero pressure) condition, the pump is swivelled be used for bearing flushing.
to its starting position (Vg max) by means of a control spring.
Connection for
Setting range from 50 bar to 350 bar flushing fluid
U R
When ordering, state in clear text:
Setting of the constant pressure control
S
Any pressure relief valve included in the circuit to limit the max.
pressure must be set to a cracking pressure at least 20 bar
above the pressure control setting.
max. 10 bar
max
350
qV Sp in L/min 4 6 8 12
Setting range
Unit dimensions DR
general dimensions and connections see pages 17...20
U R T1
50 A1
min
X3
Vg min Displacement Vg max
Y
Circuit diagram: R
Constant pressure control DR (integral valve), fixed
setting
View Y
counter-clockwise rotation clockwise rotation
A1 A/B R U const. pressure
control (DR)
T1 A1 A1 T1
S X3 X3 S
X3
A B
S T1
A1
Size A1
55 92,5
80 102
107 106
160 126
RE 92 202/07.95 | A7VO Mobile Hydraulics | Bosch Rexroth AG 13/20
Any pressure relief valve included in the circuit to limit the max.
pressure must be set to a cracking pressure at least 20 bar
above the pressure control setting.
max
315
Working pressure pB in bar
Setting range
50
min
Circuit diagram:
Remote constant pressure control DRG
P
A1 A/B R U
A
X3
S T1
14/20 Bosch Rexroth AG | Mobile Hydraulics A7VO | RE 92 202/07.95
HD Hydraulic Control,
Pilot Pressure Related
The pilot pressure related hydraulic control allows stepless setting Circuit diagram:
of the pump displacement in relation to pilot pressure. Control is Hydraulic control, pilot pressure related, HD1, HD2
proportional to the pilot pressure applied to port X1.
Start position in zero pressure condition at Vg min. A1 A/B R U
Control from Vg min to Vg max.
Y3
HD1
Pilot pressure increase (Vg min – Vg max) _______________ ∆p = 10 bar
Start of control (at Vg min), adjustable _____________ from 4 – 15 bar
When ordering, please state required start of control in clear text. X3
X1
40
S
35
Pilot pressure pSt in bar
30
25 Unit dimensions HD1, HD2
general dimensions and connections see pages 17...20
20
A1
Setting range
15
U R
10
A4
A3
A2
R A1
HD2
Y3
Pilot pressure increase (Vg min – Vg max) _______________ ∆p = 25bar
Start of control (at Vg min), adjustable _____________ from 4 - 15 bar X1
When ordering, please state required start of control in clear text. A6 (X1)
A5 (Y3)
40
35 View Y
counter-clockwise rotation clockwise rotation
Pilot pressure pSt in bar
30
25
20
S A B S
range
15
X3 X3
10
Setting
4 A1 A1
0 0,2 0,4 0,6 0,8 1,0 Y3 Y3
Vg min Displacement Vg max X1 X1
A7
A pressure of 40 bar is necessary to operate the control. The
required control oil is taken from the high pressure circuit. Connections
If the working pressure equals or exceeds 40 bar and minimum Y3 External control pressure M14x1,5 (plugged)
displacement (Vg min) is greater than zero, then no external X1 Pilot pressure M14x1,5
control pressure is required.
In other cases, an external control pressure with min. 40 bar Size A1 A2 A3 A4 A5 A6 A7
should be connected at port Y3.
55 256 221 192 170 190 186 12
If the HD control is only required as a 2-point switching control
(Vg min - Vg max), the pilot pressure at port X1 must not exceed 80 287 240 209 187 212 207 14
40 bar. 107 306 252 221 199 225 220 18
160 348 278 248 225 253 249 19
RE 92 202/07.95 | A7VO Mobile Hydraulics | Bosch Rexroth AG 15/20
Any pressure relief valve included in the circuit to limit the max.
pressure must be set to a cracking pressure at least 20 bar
above the pressure control setting.
max
315
Working pressure pB in bar
Setting range
50
min
Circuit diagram:
Hydraulic control, pilot pressure related with remote
pressure cut-off, HD1G, HD2G
A1 A/B RU X
Y3
A
X3
X1
S
16/20 Bosch Rexroth AG | Mobile Hydraulics A7VO | RE 92 202/07.95
EP Electrical Control
with Proportional Solenoid
The electrical control with proportional solenoid allows stepless Unit dimensions EP
and programmable setting of the pump displacement. Control is general dimensions and connections see pages 17...20
proportional to solenoid force (current strength). The control A1
force at the control piston is generated by a proportional solenoid.
For control of the proportional solenoid, a 24 V DC supply with U R
current levels between 200 and 600 mA is required.
Start of control (at Vg min) ______________________ 200 mA
End of control (at Vg max) _____________________ 600 mA
Insulation class IP 54
X3 Y
Start position in zero pressure condition at Vg min.
A3
Control from Vg min to Vg max R
A2
A pressure of 40 bar is necessary to operate the control. The A1
required control oil is taken from the high pressure circuit.
If the working pressure equals or exceeds 40 bar and minimum
displacement (Vg min) is greater than zero, then no external Y3
control pressure is required.
In other cases, an external control pressure with min. 40 bar
should be connected at port Y3.
A4 (Y3)
800 View Y
counter-clockwise rotation clockwise rotation
700
600
S A B S
Pilot current I in mA
500
400
300
X3 X3
200
A1 A1
100
Y3 Y3
0 0,2 0,4 0,6 0,8 1,0
Vg min Displacement Vg max
A5
Suitable control for the proportional solenoid are proportional
amplifier PV (catalogue sheet RE 95023) and chopper amplifier
Connections
CV (catalogue sheet RE 95029).
Y3 External control pressure M14x1,5 (plugged)
By using an electronic control card control of swivel time is also
possible. Size A1 A2 A3 A4 A5
Note: Pumps with EP control may only be mounted within an oil 55 256 296 170 190 12
tank when using mineral hydraulic oils and with oil temperatures
80 287 315 187 212 14
in the tank of max. 80°C.
107 306 327 199 225 18
Circuit diagram: 160 348 353 225 253 19
Electrical control with proportional solenoid, EP
Variation: Remote pressure cut-off (G)
Description see HD1G/HD2G, page 15
A1 A/B R U Circuit diagram EPG P
Y3
A1 A/B RU X
Y3
X3 X3
S S
RE 92 202/07.95 | A7VO Mobile Hydraulics | Bosch Rexroth AG 17/20
262
232
75
20
32
U R T1 150
140
A1
60
ø125 -0.025
X3 ø1
35
ø70
150
ø13.5
12
35
0´
°3
Y
12
142
7.5
31 R
45° 45°
View Y
counter-clockwise rotation clockwise rotation
62 57 76 90
Constant power control (LR)
12
T1 A1 A1 T1
S X3 X3 S
ø19
50.8
77.8
49
A B
M12; 20 deep M12; 20 deep
49 32 23.8 42.9
32 49
100
Standard series
,6
ø24,6
287
253
84
23
32 T1 165
U R
A1
144
X3
ø140-0.025
40
165
ø83
ø13.5
80
37
17
ø1
0´
°3
Y
12
157
7.5
45°
45°
31 R
265 (X3)
270 (A1; T1)
View Y
counter-clockwise rotation clockwise rotation
64 62 80 102
Constant power control (LR)
22
T1 A1 A1 T1
S X3 X3 S
88.9
57.2
ø25
62
A B
M12; 17 deep M12; 17 deep
57 34 27.8 50.8
34 57
111
ø29,6
307
286 (T1)
272
86
40 25
U R T1 190
A1
150
X3
ø160 -0.025
46
37
ø90
190
ø2
18
ø17.5
41
00
0´
°3
Y
12
170
7.5
39 R 45°
45°
284 (X3)
289 (A1)
View Y
counter-clockwise rotation clockwise rotation
72 70
88 105
Constant power control (LR) 22
T1 A1 A1 T1
S X3 X3 S
57.2
88.9
ø25
62
A B
M12; 17 deep M12; 17 deep
55 36 27.8 50.8
36 55
115
Standard series
2,
5
A1
160
X3
ø180 -0.025
55
46
27
ø100
210
47
ø17.5
24
ø2
0´
°3
Y
12
193
7.5
45°
39 R 45°
327 (X3)
331 (A1)
View Y
counter-clockwise rotation clockwise rotation
84 78
22 100 126
Constant power control (LR)
T1 A1 A1 T1
X3 X3
S S
106.4
ø32
66.7
75
A B
M14; 19 deep M16; 24 deep
66 40 31.8 61.9
40 66
Shaft end Connections
Z Splined shaft A, B Service line ports SAE 1 1/4"
W 45x2x30x21x9g (metric mounting threads) 420 bar (6000 psi)
DIN 5480 High pressure series
36 S Suction port SAE 3"
(metric mounting threads) 140 bar (2000 psi)
R
Standard series
2,
5
Bosch Rexroth AG © 2003 by Bosch Rexroth AG, Mobile Hydraulics, 89275 Elchingen
Mobile Hydraulics All rights reserved. No part of this document may be reproduced or stored,
Product Segment Axial Piston Units processed, duplicated or circulated using electronic systems, in any form or by
Horb Plant any means, without the prior written authorization of Bosch Rexroth AG. In the
Elchingen Plant
event of contravention of the above provisions, the contravening party is obliged
Glockeraustrasse 2 An den Kelterwiesen 14
to pay compensation.
89275 Elchingen, Germany 72160 Horb, Germany The data specified above only serve to describe the product. No statements
Telephone +49 (0) 73 08 82-0 Telephone +49 (0) 74 51 92-0 concerning a certain condition or suitability for a certain application can be
Facsimile +49 (0) 73 08 72 74 Facsimile +49 (0) 74 51 82 21 derived from our information. The given information does not release the user
info.brm-ak@boschrexroth.de from the obligation of own judgement and verification. It must be remembered
www.boschrexroth.com/brm that our products are subject to a natural process of wear and aging.