CURVED STEEL PANELS (FOR COLUMNS)
Type 110cm
Design data:
1. S
8
PL 80*8mm
80 80 1100 80
R R
PL. 80*8mm
HEET(3mm ):
Section Properties:
for 1m wide
A = 100(0.30) = 30 cm2
I = 100(0.3) 3/12 = 0.225 cm4
Z = 100(0.3) 2/6 = 1.5 cm3
Allowable bending stress in steel (Fall) = 1400 kg/cm 2
(E) for steel = 2100 t/cm 2
2. MAIN BEAMS 2(PLATE 80*8mm):
Section Properties:
A = 8.0(1.60) = 12.80 cm 2
I = 1.60*(8.0)3/12 = 68.27 cm4
Z = 17.06 cm3
3. SECONDARY BEAMS (PLATE 80*8)mm:
Section Properties:
A = 8.0(0.80) = 6.40 cm2
I = 0.8*(8.0)3/12 = 34.13 cm4
Z = 8.53 cm3
4. CONNE
CTIN
G
CONCRETE PRESSURE :
For column height of 4.00m
Hcolumns = 400 cm
Assumed rate of placement =6.00 m/hr
Concrete temperature =30oC
From CIRIA REPORT 108:
Pb= b ( K 1 Vb K 2 K T h K 1 Vb t/m2
KT=[36/(T+16)]2 = 0.61
Pb= 2.5 (1.5 6.0 0.45 0.61 4.0 1.5 6.0 )=9.56 t/m2
Max pressure = 9.56 t/m2
For secondary plate each 80cm
Load /m’ =9.56 x0.8 =7.64 t/m’
R= w* * / 4
R= 7.64*3.14*1.10/4 = 6.60 t each 80cm
Check Elements
ㄱ SHEET(3mm ):
A = 30 cm2
Pall = 30*1.4= 42 t > P act O.K
A = 6.40 cm2
Fact = R/A
Fact = 6.60/6.40 = 1.03 < 1.40 O.K
D = 0.0068 WL4\EI
= 0.0068x8.25 (30) 4x10\100x2100x68.20
= 0.03 mm < 3.00mm