Name of the site : DEEP WELL DRILLING WITH HOTWORKS
Location : ALANGILAN BATANGAS Project in Charge : KENNETH INFANTE
Sl. Sequence Potential Hazards Protective measures to
No. of the be taken Action By job
Conducting site inspection.
The entry of non – certified
tools/equipment (Welding Transformer, Generator.) to be 1 Planning Fire & Explosion authorized under Permit to Work System. Keep the fire extinguishers (Dry Chemical)&in ready condition. Keep trained firewatch supervisor/safety officer Take a Hot Work Permit and Unauthorized Work other associated permits. Ensure the welding equipment (torch, cable, electrode holder, Defective Tools transformer, generator, cable connector, plugs, sockets etc.) are free from defect and earthedasneeded. 2 Radiation from UV / Wear protectivegoggles. Cutting IR Rays (Flash Eye) / Ensure proper ventilation and Welding Exposure to Welding Fumes fume extraction equipment.
Wear long sleeved coverall,
Burns leather apron; welder’shood. Provide a check valve (flash Flash Back Fire back arrester)between oxy- Sl. Sequence Potential Protective measures to be taken No. of the Hazards Action By job
acetylene/LPG hose& gas regulator.
All cords should be inspected prior to use and should be in good working Electric Shock condition.
Keepoxy– acetylene/LPG cylinders at
Cylinder near the Hot least 5 meters away from hot Work area workarea. Isolate the cylinder when not in use. Keep Welding Generator at least 5 Transformer / meters away from hot workarea. Generator near the Hot Work area Stop the generator when not in use. Ensureproperwindup& housekeeping 3 atworksite. Windup & The accessories (torch, cable, Housekeeping Scattered Material electrode holder) not being used must be disconnectedfrom transformer / generator and stored separately. Gas leakage detection to be installed at above the gas cylinder store area. 4 Fully cylinder shall be stored Storage area Gas leakage vertically.