Sie sind auf Seite 1von 1

Certificate No.

00000/COEKAM
Date: January 15, 2019
Issuing Office:
JL. Teuku Umar No. 65 Samarinda 75126, Kalimantan Timur, Indonesia
Phone/Facs: +62 541 6293771/6293777
Email: cs.smr@sucofindo.co.id

REPORT OF ANALYSIS

PRINCIPAL : INSANI BARAPERKASA, PT


TYPE OF SAMPLE : Coal
DESCRIPTION OF SAMPLE : Sample supplied by client in unsealed plastic bags
DATE OF RECEIVED : January 10, 2019
DATE OF ANALYSIS : January 10 up to 11, 2019
Total Moisture, Moisture in the Analysis Sample, Ash Content, Volatile
TESTED FOR :
Matter, Fixed Carbon, Total Sulfur and Gross Calorific Value
REFERENCES : Letter dated on January 11, 2019
SEAM E RMG PIT MAHAKAM TBS SEAM 18
SAMPLE CODE
(PADAT KARYA SP) SEAM C PADAELOK BMS
Mass As Received ( kg ) 6.85 6.34 6.82
PARAMETER RESULTS
Total Moisture % arb 34.3 35.3 27.8
Moisture in the Analysis Sample % adb 25.5 24.2 20.8
Ash Content % adb 4.2 2.9 5.5
Volatile Matter % adb 36.4 38.1 37.4
Fixed Carbon % adb 33.9 34.8 36.3
Total Sulfur % adb 0.47 0.10 0.20
Gross Calorific Value kcal/kg adb 4672 4832 4896
Gross Calorific Value kcal/kg arb 4120 4124 4463
Gross Calorific Value kcal/kg daf 6646 6628 6643

Sample preparation and testing was done in accordance with below standard methods:
Sample Preparation : ASTM D2013M – 12
Total Moisture : ASTM D3302 – 17
Moisture in the Analysis Sample : ASTM D3173M – 17
Ash Content : ASTM D3174 – 12
Volatile Matter : ASTM D3175 – 17
Fixed Carbon : ASTM D3172 – 13
Total Sulfur : ASTM D4239 – 17
Gross Calorific Value : ASTM D5865 – 13

This report of analysis is issued only relates to the tested sample and can not be reproduced except in with approval the written the Sucofindo Laboratory

This Certificate/report is issued under our General Terms and Conditions, copy of which is available upon request or may be accessed at www.sucofindo.co.id

Dept. of Mineral & Coal Testing

5801.01900031 Gatot Kafrawi


011900439-441.Rz.Slm