Beruflich Dokumente
Kultur Dokumente
Variable displacement
axial piston pump
Contents Page
Note
This document and other information from Parker Hannifin GmbH, its subsidiaries, sales offices and authorized
distributors provide product or system options for further investigation by users having technical expertise. Before
you select or use any product or system it is important that you analyse all aspects of your application and review
the information concerning the product or system in the current product catalogue. Due to the variety of operating
conditions and applications for these products or systems, the user, through his own analysis and testing, is solely
responsible for making the final selection of the products and systems and assuring that all performance and
safety requirements of the application are met. The products are subject to change by Parker Hannifin GmbH at
any time without notice.
PVplus UK 18.10.00.PM6.5
1. Installation and start-up The suction pipe must have access to clean, cooled
For a safe and disruption free operation of any ma- and filtered fluid, free of air bubbles. No turbulences
chine or system a careful installation and start up or high flow velocities should occur at the tube inlet.
following the manufacturers instruction is mandato- Therefore position inlet as far as possible away from
ry. return line and drain line. Make sure that the fluid
Hydraulic systems can be designed for many totally circulation in the reservoir does keep return flow from
different functions and they require consequently suction pipe inlet. In case of positive head use shut
different start up procedures. The hydraulic pump is off valve in the inlet, monitored with proximity switch
in this respect only one, but nevertheless very im- or equivalent to avoid start up of motor when valve
portant component of the whole system. is closed. When installed into the reservoir use short
A general start up instruction therefore can give many suction pipe with pipe end cut under 45°.
helpful hints but it needs to be completed by specific
additions depending of the individual nature of the Pressure port
system or power unit. Select correct pressure rating for pipe, hose and
During installation and start up the following steps connectors. Take pressure peaks into account. Di-
need to be carried out carefully: mension the piping according to the port size. Pre-
Visual inspection vent excitation of the system by using flexible port
connections.
Make sure that all components of the shipment are
complete, free of any damage, free of outside con- Drain port
tamination and properly protected against ingression Always use highest possible drain port of the pump.
of contamination. Drain port must be higher than pump centerline or
Cleanliness install additional air bleed line. Never combine pump
drain line with other return lines and/or drain lines.
Contamination of any kind is the enemy of any hy-
Pump shall not be able to run empty. Max. allowable
draulic component. It is still the number 1 cause for
case pressure £0.5 bar (2 bar peak), also during
component failure. Therefor maximum care and
compensation.
cleanliness are required during all handling and
managing of parts that come in contact with the hy- Use low pressure pipe/hose, as short as possible
draulic fluid. All ports of the pumps and other com- and full cross section according to port dimension.
ponents must be covered until pipes or hoses are Do not use elbows or sharp corners. When drain
mounted to them. Perform assembly preferably in a port is on the side of the pump drain line should have
dry and dust free room. Use only suitable tools. bridge higher than pump top (also when installed in
reservoir). Drain pipe must end at least 200 mm be-
Installation
low fluid level even at lowest filling level. Never let
Installation horizontal or vertical, avoid rigid connec-
drain flow go direct into suction area of reservoir (tem-
tion from pump to reservoir cover or frame and to
perature, air bubbles). Max. length 2m, otherwise
inlet and outlet piping to prevent excitation of the
use larger pipe diameter than port size.
whole system due to pump vibrations.
Note: During operation of PV pumps of all sizes un-
Suction port
der the following conditions:
Position to the side or to the bottom, max. fluid ve-
Q ~ Qmax
locity approx. v = 0.5 m/sec, cut suction pipe inlet
pinlet < 2 bar absolute
under 45°. Minimum distance from bottom 2 - 3 times
diameter and, even at lowest fluid level, approx. 200 Poutlet < 25 bar
mm below fluid level. Inlet pressure, even during (e. g. low pressure circulation) the drain flow can
compensation, never should drop below 0.8 bar (ab- change direction. Fluid is taken from the case into
solute). the piston mainly through the decompression orifice
Absolute gas tight connection (risk of cavitation, and across the slipper. There is a danger that the
noise). Air bubbles due to vacuum in the inlet can pump case runs dry, the pump overheats and the
destroy pumps within a short time due to cavitation bearings lack of lubrication when the fluid is removed
erosion. Suction pipe should be as short as possi- from the pump case.
ble. Use only clean, low pressure pipe, avoid sharp Therefore the drain pipe must be able to take fluid
elbows and any restriction of cross section. from the reservoir. That means: The drain line must
PVplus UK 18.10.00.PM6.5
end below fluid level, and a check valve in the drain
Port positions for PV (shown for clockwise rotation, for ccw rotation ports are mirrored)
Interface for
compensator
Suction port
(inlet) Gage port
Flushing port,
covered Pressure port
below pump (outlet)
line is not permissible. If it has to be installed for flushing of the pump case, to avoid high fluid tem-
whatever reason the case needs to be flushed with peratures.
a flow of 10 - 15% of the nominal pump flow. A flushing flow of 5 - 10% of nominal flow should
Flushing port be enough.
The PV pumps of design series 40 (PVplus) are
Drive input
equipped with a flushing port. This port is smaller
in diameter than the drain port(s) and is located For direct drive use elastic coupling free of axial
opposite to these ports in the bottom of the pump and radial reaction forces. Please follow strictly
case. The flushing flow can - depending on the the instructions of the coupling supplier regarding
actual working conditions - be used to keep the axial clearance, axial displacement and angular
pump case filled, to warm up the pump (during tolerances. Couplings never shall be mounted
cold temperature operation) or for a better heat using a hammer. Threads in the shaft end allow
dissipation. Permanent dead head operation ( >15 smooth mounting of the coupling.
min) either for pumps of frame size 3 and larger The drive shaft should only carry true torque. Con-
(PV063 and higher) or at high input speeds above tact Parker for allowable side loads or axial forces.
1,800 rpm as well as high environmetntal tempera- PV pumps are normally for one direction of rota-
tures flushing are recommended. Also dead head tion only. Therefore check rotation of drive motor
operation with HFC fluids (water glycole) requires prior to installation.
PVplus UK 18.10.00.PM6.5
2. Displacement adjustment
Displacement change
Displacement change
Minimum adjustable
All axial piston pumps of the PV series are equipped
with an adjustable displacement limiter.
(approx. cm³/U)
(approx. cm³/U)
(approx. cm³/U)
displacement
The servo piston stroke is limited at full displace-
ment by a screw, guided in the end cover plug of
per turn
per mm
the servo piston bore. The screw is protected against
unintentional adjustment by a self-sealing lock nut.
Size
The factory setting of the displacement is accord-
ing to the nominal displacement of the pump. An PV016 1.5 1.5 5
adjustment may only be made to a lower displace- PV020 1.5 1.5 8
ment (turning screw in). An adjustment to a higher PV023 1.5 1.5 12
than the nominal displacement can destroy the PV032 2.2 2.2 17
pump. PV040 2.2 2.2 25
Adjustment should only be made with the pump PV046 2.2 2.2 30
working at full displacement (not compensated) and
PV063 3.4 3.4 35
at a low output. At full displacement the piston area
PV080 3.4 3.4 50
of the servo piston is under case pressure. Open-
ing the self-sealing nut will only cause a negligible PV092 3.4 3.4 65
leakage under these conditions. PV140 5.6 8.4 20
PV180 5.6 8.4 60
PV270 6.8 10.2 120
Adjustment screw
Lock nut 3. Standard pressure compensator, code ...F*S
The adjustment of the compensating pressure is
performed for the standard pressure compensa-
tor directly at the compensator.
To adjust the pressure, the lock nut (SW 19) is to
be loosened and the adjustment spindle is to be
turned. Turning clockwise will increase the com-
pensating pressure, turning counter-clockwise will
decrease the compensating pressure. The
adjustment spindle has a thread pitch of 1mm
(thread M 12 x 1).
The following limits exist for the three spring
options:
Minimum pressure
Pressure variation
Nominal pressure
Note! Maximum
Pressure range
adjustment
possible
setting
Snap ring
Adjustment
spindle
Lock nut
Although for all three springs the min. adjustable The max. possible pressure adjustment is reached,
pressure is approx. 8 - 10 bar (min. compensating when the spindle is completely turned in (snap ring
pressure of a PV pump), for the spring code H a touches the lock nut). In this situation there is a
min. pressure adjustment of 40 bar and for the danger of spring overload depending of manufac-
spring code W a min. pressure adjustment of 70 turing tolerances. If such a high adjustment should
bar is recommended. Adjusting lower pressures be prohibited, washers can be placed between lock
with these springs can lead to an extremely slow nut and snap ring.
compensator response.
4. Remote pressure compensator, code ...FRC
Snap ring
Adjustment
spindle
Lock nut
Remote port
For the remote pressure compensator the pres- The pilot valve can be mounted as far as 15 m
sure adjustment is done at a pressure pilot valve away from the pump. Please note for a distance
(not included in the shipment of the pump). The above 5 m, that low temperatures and a high fluid
pilot valve is connected to the remote port. viscosity can significantly increase the compen-
The pressure pilot valve must be capable of hand- sating pressure.
ling securely a pilot flow of approx. 1.2 l/ The pilot connection should be dimensioned to
min.Therefore a nominal flow of 3 - 6 l/min is re- avoid any considerable pressure drop in this line.
commended for the pilot valve. Selection of a pilot The pressure adjustment and the max. pressure
valve too small or too large can result in compen- setting are given by type and setting of the pilot
sator instability. valve.
The pilot port thread can be determined from the The min. compensating pressure can be calculated
ordering code of the pump (threads and port code): from the min. adjustable pressure of the pilot valve
plus the differential pressure setting at the com-
Threads and Port pensator.
port code dimensions
Factory setting for the compensator differential
1 G 1/4 BSPP pressure is 15 ±1 bar. This adjustment should only
3 7/16-20 UNF be modified, if specifically required. To change the
7 M12 x 1.5 ISO 6149-1 adjustment the lock nut is to be loosened and the
adjustment spindle to be turned. Clockwise turn-
8 M12 x 1.5 ISO 6149-1 ing will increase the differential pressure setting.
PVplus UK 18.10.00.PM6.5
The adjustment range reaches from approx. 8 bar For differential pressure adjustment the true differ-
to approx. 80 bar. The actual compensating pres- ential pressure should be measured (pump outlet
sure is given by the pressure setting of the pilot pressure minus pilot pressure). An adjustment only
valve at nominal pilot flow (approx. 1.2 l/min) plus measuring pump outlet pressure requires an abso-
the compensator differential pressure. lutely pressure free remote port.
At factory setting and fully unloaded remote port Functional descriptions and circuit diagrams of all
the min. compensating pressure is 15bar. compensators see Catalogue 2500/UK.
For the remote pressure compensator the pres- The min. compensating pressure can be calculated
sure adjustment is done at a pressure pilot valve from the min. adjustable pressure of the pilot valve
(not included in the shipment of the pump). This plus the compensating differential pressure ad-
pilot valve is mounted to the NG6 interface on top justed at the compensator.
of the compensator valve. Parker offers a wide Factory setting for the compensator differential
variety of compensator accessories (pilot valves) pressure is 15 ±1 bar. This adjustment should only
under ordering code PVAC... . be modified if necessary. To change the adjust-
The pressure pilot valve must be capable of hand- ment the lock nut is to be loosened and the ad-
ling securely a pilot flow of approx. 1.2 l/ justment spindle to be turned. The adjustment
min.Therefore a nominal flow of 3 - 6 l/min is re- range reaches from approx. 8 bar to approx. 80
commended for the pilot valve. Selection of a pilot bar. The actual compensating pressure is given
valve too small or too large can result in compen- by the pressure setting of the pilot valve at nomi-
sator instability. nal pilot flow (approx. 1.2 l/min) plus the compen-
The pilot valve is mounted directly on top of the sator differential pressure.
compensator valve (mounting interface NG6, DIN At factory setting and fully unloaded remote cham-
24340 on compensator topside). The mounting ber (compensator spring chamber) the min. com-
threads for the pilot valve are M 5 for threads and pensating pressure is 15 bar.
port code 1 and 8 or #10 - 24 UNC for threads and For differential pressure adjustment the true dif-
port code 3 and 7. ferential pressure should be measured (pump out-
Beside a manual operated pilot valve (e. g. code let pressure minus pilot pressure). An adjustment
PVAC1P...) also a proportional pressure valve (e. when only measuring the pump outlet pressure
g. DSAE... or RE...) or a multiple pressure pilot requires an absolutely pressure free compensator
circuit (e.g. PVAC2P...) can be installed. spring chamber.
Compensator accessories can be found in Cata- Functional descriptions and circuit diagrams of all
logue 2500/UK, chapter 1, page 1-38ff. Propor- compensators see catalogue pages 1-32ff.
tional pressure pilot valves as well as driver elec-
tronics to operate these valves are presented in
chapters 4 and 10.
The pressure adjustment, and the max. pressure
are defined by type and nature of the pressure
pilot valve.
PVplus UK 18.10.00.PM6.5
Snap ring
Adjustment spindle
Lock nut
The load sensing or flow compensator primarily The pressure pilot valve must be capable of hand-
controls the pump output flow. To achieve this the ling securely a pilot flow of approx. 1.2 l/
load pressure after a main stream throttle valve min.Therefore a nominal flow of 3 - 6 l/min is re-
(load sensing valve, not included in the shipment commended for the pilot valve. Selection of a pilot
of the pump) is connected to the load sensing port valve too small or too large can result in compen-
of the compensator. The compensator control strat- sator instability.
egy is, to keep the pressure drop constant across The pressure adjustment and the max. pressure
this main stream throttle valve. are defined by type and nature of the pressure
To add pressure compensation to the load sens- pilot valve.
ing function, an orifice (Ø 0.8 mm) is to be added The minimum compensating pressure can be cal-
into the load sensing line and a pressure-pilot valve culated from the min. adjustable pressure of the
must be connected between orifice and compen- pilot valve plus the compensating differential pres-
sator valve (see circuit diagram). sure adjusted at the compensator.
Circuit diagram of a load sensing compensator with external pressure pilot valve
PVplus UK 18.10.00.PM6.5
The connecting thread at the load sensing port is The actual compensating pressure is given by the
defined by the threads and port option of the pump pressure setting of the pilot valve at nominal pilot
ordering code: flow (approx. 1.2 l/min) plus the compensator dif-
ferential pressure.
Threads and Port
port code dimensions At factory setting and fully unloaded remote cham-
ber (compensator spring chamber) the minimum
1 G 1/4 BSPP compensating pressure is 10 bar.
3 7/16-20 UNF For differential pressure adjustment the true dif-
7 M12 x 1.5 ISO 6149-1 ferential pressure should be measured (pump out-
8 M12 x 1.5 ISO 6149-1 let pressure minus pilot pressure). An adjustment
only measuring pump outlet pressure requires an
Factory setting for the compensator differential absolutely pressure free compensator spring
pressure is 10 ±1 bar. This adjustment should only chamber.
be modified if necessary. To change the adjust- The pressure adjustment also influences the ef-
ment the lock nut is to be loosened and the ad- fective output flow of the pump. The higher the
justment spindle to be turned. differential pressure setting, the higher the flow at
The adjustment range reaches from approx. 8 bar a given setting of the load sensing valve.
to approx. 80 bar. Note, that a higher adjustment Functional descriptions and circuit diagrams of all
means higher power losses at the load sensing compensators see Catalogue 2500/UK, pages 1-
valve. 32ff.
Adjustment spindle
Lock nut
The load sensing or flow compensator primarily The pressure pilot valve must be capable of hand-
controls the pump output flow. To achieve this the ling securely a pilot flow of approx. 1.2 l/
load pressure after a main stream throttle valve min.Therefore a nominal flow of 3 - 6 l/min is re-
(load sensing valve, not included in the shipment commended for the pilot valve. Selection of a pilot
of the pump) is connected to the load sensing port valve too small or too large can result in compen-
of the compensator. The compensator control stra- sator instability.
tegy is, to keep the pressure drop across this main The thread at the load sensing port is given by the
stream throttle valve constant. threads and port option of the pump ordering code:
In addition the compensator with the code ...FF1
Threads and Port
comes with a top side mounting interface NG6 DIN
port code dimensions
24340 and a pilot orifice Ø 0.8 mm in the load
sensing port. Directly on the mounting interface a 1 G 1/4 BSPP
pressure pilot valve can be mounted. The mount- 3 7/16-20 UNF
ing threads for the pilot valve are M5 for threads
7 M12 x 1.5 ISO 6149-1
and port code 1 and 8 or #10 - 24 UNC for threads
and port code 3 and 7. 8 M12 x 1.5 ISO 6149-1
PVplus UK 18.10.00.PM6.5
The pressure adjustment and the max. pressure are At factory setting and fully unloaded remote cham-
defined by type and nature of the pressure pilot ber (compensator spring chamber) the min. com-
valve. pensating pressure is 10 bar.
The min. compensating pressure can be calculated For differential pressure adjustment the true differ-
from the min. adjustable pressure of the pilot valve ential pressure should be measured (pump outlet
plus the compensating differential pressure adjusted pressure minus pilot pressure). An adjustment only
at the compensator. measuring pump outlet pressure requires an absolu-
Factory setting for the compensator differential pres- tely pressure free compensator spring chamber.
sure is 10 ±1 bar. This adjustment should only be The pressure adjustment also influences the effec-
modified if necessary. To change the adjustment the tive output flow of the pump. The higher the differen-
lock nut is to be loosened and the adjustment spindle tial pressure setting is, the higher the flow is going to
to be turned. The adjustment range is from approx. be at a given setting of the load sensing valve.
8 bar to approx. 80 bar. The actual compensating Functional descriptions and circuit diagrams of all
pressure is given by the pressure setting of the pi- compensators see Catalogue 2500/UK, pages 1-32ff.
lot valve at nominal pilot flow (approx. 1.2 l/min) plus
the compensator differential pressure.
Adjustment spindle
Lock nut
ssure
remote pre Snap ring
pe nsa tor
com
Adjustment spindle
The two spool compensator, code FT1 has two sep- is 15 ± 1 bar. These adjustments should only be
arate compensator valves for flow and pressure. modified, when necessary.
The flow compensation is done with the lower valve. To change the adjustment the lock nut is to be loos-
It is connected to the load sensing port of the hy- ened and the adjustment spindle to be turned. The
draulic circuit. adjustment range reaches from approx. 8 bar to
The remote pressure compensator is mounted on approx. 80 bar. The actual compensating pressure
top of the flow compensator and it overrides the flow is given by the pressure setting of the pilot valve at
compensation, when pressure setting is reached. On nominal pilot flow (approx. 1.2 l/min) plus the com-
the mounting interface NG6, DIN 24340 on top of pensator differential pressure.
the pressure compensator stage as described for At factory setting and fully unloaded remote cham-
the remote pressure compensator FR1 any pres- ber (compensator spring chamber) the min. com-
sure pilot valve can be mounted, as long as is fulfills pensating pressure is 10 bar.
the requirements described there. For mounting in- For differential pressure adjustment the true differ-
terface, threads and port dimensions see also cata- ential pressure should be measured (pump outlet
logue chapter 5. pressure minus pilot pressure). An adjustment only
The factory setting of the flow compensator is 10 ± 1 measuring pump outlet pressure requires an absolu-
bar, the adjustment for the pressure compensator tely pressure free compensator spring chamber.
PVplus UK 18.10.00.PM6.5
9. Horse power compensator, codes ...*L*, ...*C* Section of a horse power compensated pump
Depending on its type, the horse power compen-
sator consists of a modified remote pressure com-
pensator or a modified load sensing compensator
in combination with the horse power pilot cartridge.
The opening pressure of this pilot cartridge de-
pends on the actual displacement of the pump. At
large displacements the opening pressure is low.
As the displacement is reduced the opening pres-
sure is increased according to the form of the con-
tour sleeve in the pump. That leads to the desired
control characteristic (constant input horse power).
That is achieved by having the pilot cartridge seat
being guided by the contour sleeve. This contour
sleeve is firmly connected to the servo piston. The
contour represents the desired input horse power.
The horse power pilot cartridge is internally con- Horse power pilot cartridge
nected to the compensator valve. Compensator
valves for horse power compensated pumps dif- Set screw
fer from standard compensator valves only in this
additional port in the mounting interface. Lock nut
For a standard horse power compensator with or-
dering code ...*L* a modified remote pressure com-
pensator is used. For a horse power compen-sator
with load sensing, code ...*C* a modified load sens-
ing compensator is used.
Constant horse power curve with adjustment
Adjustment spindle
Lock nut
A horse power compensator with ordering codes pilot valve can be mounted when it fulfills the
...*LA resp. ...*CA has a compensator valve with a requirements. For valve selection and requirements
topside mounting interface NG6, DIN 24340. Any as well as mounting dimensions see Catalogue
2500/UK, chapter 4.
9.2 Horse power compensator, ordering codes ...*LB resp. ...*CB
Snap ring
Adjustment spindle
Lock nut
Remote resp.
load sensing port
For horse power compensators with ordering codes If another compensating pressure or a closer tol-
...*LB resp. ...*CB the compensator valve has a erance is required, an external pilot valve accor-
pilot port on its side. If no pilot valve pilot valve for ding to Catalogue 2500/UK, chapter 3 can be con-
adjustable pressure compensation is connected, nected. Chapter 3 also describes valve require-
the compensating pressure is defined by the de- ments and adjustment procedures.
sign of the contour sleeve and can be in the range Functional descriptions and circuit diagrams of all
of 370 ± 20 bar, depending on the adjustment of compensators see catalogue.
the horse power pilot valve.
Cap nut
The electrohydraulic proportional displacement After that the zero setting of the LVDT must be
control consists of the proportional displacement controlled. The LVDT must be connected to termi-
control valve shown above and the inductive posi- nals 23, 24 and 25 of the electronic control mod-
tion transducer (LVDT) used for the displacement ule and the solenoid to terminals 14 and 15.
feedback.
Setting dimension for LVDT armature Inductive position transducer (LVDT)
Do not
adjust!
Zero
Size Dimension
adjustment
A [mm]
(secured)
PV016-PV023 64.0
PV032-PV046 64.0 Electrical
PV063-PV092 65.5 connection
PV140-PV180 65.5
PV270 65.5
LVDT and proportional displacement control valve When the pump is running the input command for
are factory set and the adjustment is secured. Any the displacement is to be set to 0 and the pressure
new or re-adjustment is only necessary after repair relief valve of the system / test rig should be set to a
or service. pressure > 25 bar. All other valves of the system
Prior to an adjustment first the setting dimension of must be closed.
the LVDT probe is to be checked (see figure and The pump then will compensate at the min. com-
table above). The adjustment is secured with an ad- pensating pressure (10 ± 2 bar) to its min. displace-
hesive. ment. By adjusting the zero adjustment potentiome-
Any new adjustment must be secured with an adhe- ter at the LVDT the voltage at the diagnosis output
sive, to avoid unintentional variation of the adjust- must be adjusted to 0 V, because this situation rep-
ment. resents the absolute minimum working displacement
of the pump.
PVplus UK 18.10.00.PM6.5
Then the set command for the displacement must If the max. displacement is reached at an input
be raised, until the max. swash plate angle is command considerably below 10 V, a correction
reached. This can either be checked by monitor- can also be achieved by setting the MAX potenti-
ing the diagnosis output or by using a flow meter. ometer accordingly.
The swash plate angle has reached its maximum, To perform a basic adjustment of the proportional
when the displacement does not grow further, even displacement compensator valve, first the cap nut,
when the input command is increased. If the input the lock nut and the O rings and washers must be
command reaches 10 V (or 20 mA for electronic removed.
modules with current input = max. input command) Then a medium input command is to be adjusted
before the max. displacement is reached, the dis- (e. g.: 50% displacement).
placement can be increased further by using the
MAX potentiometer on the module.
In this control situation the proportional solenoid See Catalogue 2500/UK, chapter 10.
should draw approx. 60% of its nominal current Note
(nominal current 1.3 A; current in control situation The proportional displacement control code
750 mA). Under this condition the solenoid works ...FPV does not include pressure compen-
at half its nominal force in control position and a sation. Therefore the hydraulic circuit must be
similar control response speed is achieved for equipped with a pressure relief valve capable
upstroking and downstroking. Turning the set screw of the full pump output flow.
varies the solenoid current. Clockwise turning in-
creases the solenoid current. After that the set screw
is to be secured with the lock nut and the adjust-
ment screw to be covered by the cap nut.
11. Electrohydraulic p/Q control, codes ...FPR, ...FPZ
The electrohydraulic p/Q control, code FPR is For an electronic pressure adjustment the use of a
equipped with an additional remote pressure com- proportional pressure pilot valve with NG6 mounting
pensator valve on top of the proportional displace- interface is recommended, e. g.: the series DSAE...
ment control valve. This valve overrides the dis- or RE... on top of the remote pressure compensator
placement control, when the max. pressure setting stage. These valves are optimally adjusted for use
of the pilot valve is reached (see figure next page). with pump compensator and can be powered by the
This remote pressure compensator is equivalent to electronic control modules PQ0*-P00 or PQ0*-Q00.
the valve used for pressure compensation in the The solenoid of the pressure valve is to be connected
two spool-compensator code FT1, described in to terminals 16 and 17 of the control module.
Catalogue 2500/UK, chapter 8. There also the ad- Please note: The proportional control only can work,
justment is described. As noted there the compen- when the pump output pressure is above 10 - 15
sating differential pressure is factory set to 12 ± 1 bar. Below that the servo spring of the pump cannot
bar, leading to a minimum compensating pressure be compressed and the pump will not compensate.
of also 12 bar.
PVplus UK 18.10.00.PM6.5
Basic compensator
setting
Electrical connection
A basic adjustment of the proportional displace- See also installation manuals for electronic mod-
ment control valve (lower valve) is performed in ules PQ0*-P00, Bulletin 3241-M1/UK and PQ0*-
the same way as described above in Catalogue Q00, Bulletin 3242-M1UK.
2500/UK, chapter 10. Functional descriptions and circuit diagrams of all
The adjustment of the remote pressure com- compensators see catalogue, publication 2500/
pensator stage is described in chapter 5, remote GB, pages 1-32ff.
pressure compensator FR1.
Lock nut
Set screw
PVplus UK 18.10.00.PM6.5
For multiple pressure pilots, codes PVAC2P..., two direct-action pressure cartridge valves is used
PVAC2E... and PVAC2M... a sandwich valve with to pilot the pump.
Set screw
Lock nut
For code PVAC2P... a single-solenoid directional When energizing solenoid A (B-side) the spring
control valve is included for pressure selection. The chamber is connected to the A-side pilot cartridge;
valve switches between low pressure setting and high the pressure adjusted here controls the pump.
pressure setting. During low pressure both pilot car- When solenoid B is energized the spring chamber
tridges are connected to the compensator, in the high of the compensator is connected to pilot cartridge
pressure situation (solenoid energized) only the A- B; then the pressure adjusted on this cartridge
side cartridge is connected. Therefore the B-side pilot defines the pump compensating pressure. With
needs to be set for low pressure. The directional this version the pressure settings can be adjusted
control valve series D1VW has spool code 6. independently; no high / low preference is to be
For code PVAC2E... for pressure selection a two- observed. The DCV of the series D1VW has spool
solenoid directional control valve is included, which code 2.
switches between low pressure setting, high pres- This version should be used, when between high
sure setting and standby pressure. In neutral posi- and low pressure selection the standby operation
tion both cartridges are connected to the compen- is used in the machine cycle.
sator valve. The lower pressure defines the com- Code PVAC1E... is similar to code PVAC2P..., with
pensating pressure of the pump. When the A sole- the exception, that only one pilot cartridge is in-
noid (B-side) of the DCV is energized only the A- stalled. In neutral position of the D1VW the standby
side cartridge is connected; the (higher) pressure pressure is selected.
adjusted there defines the compensating pressure.
For additional information, circuit diagrams and
When solenoid B is energized the valve spool con- functional descriptions and complete pump order-
nects all four ports. Then the spring chamber of the ing code see Catalogue 2500/UK.
compensator valve is directly connected to the case
drain of the pump, the pump compensates works at
minimum compensating pressure (standby).
The directional control valve series D1VW has spool
code 55. This spool code is used to avoid a blocked For more information, spare parts or service
spool position during transient. please contact:
This version is recommended, when during a ma- Parker Hannifin GmbH
chine cycle the pressure is to be switched between Hydraulic Controls Division
high and low. Business Unit Pumps and Motors
For code PVAC2M... also a dual solenoid valve is Gutenbergstr. 38
used. In neutral position all four ports are connected. 41564 Kaarst, Germany
The compensator spring chamber is connected to Tel.: (+) 2131 / 513-0
the case drain, the pump is compensating at min. Fax: (+) 2131 / 513-285
compensating pressure (standby). Internet: www.parker.com
PVplus UK 18.10.00.PM6.5
PVplus UK 18.10.00.PM6.5
PVplus UK 18.10.00.PM6.5