Sie sind auf Seite 1von 18

GMCC GPRS & EDGE RADIO PERFORMANCE INDICATO

Categories Type
KPI

KPI

KPI

Reference
IP

Reference

Reference

PI

PI

Interference
Interference
PI

PI

PI
PI
Capacity - CCCH PI

PI

Capacity - PCU PI
PI

PI

PI
Capacity - Multislot PI
Utilization
PI

PI

PI

PI

PI

Capacity - PDCH PI

PI

PI
PI
Mobility PI
DGE RADIO PERFORMANCE INDICATORS - R10

Frame Direction
DL
GPRS IP/LLC Throughput
UL

DL
EDGE IP/LLC Throughput
UL

DL
IP Transfer Interrupts (TBF minutes per interrupt)
UL

DL
GPRS LLC Data Volume per PFC activity
UL

DL
EDGE LLC Data Volume per PFC activity

UL

DL
% EDGE Usage

UL

DL
CS 1-2 Radio Link Bitrate
UL
DL
EDGE Radio Link Bitrate

UL

% Abnormally Released TBFs (due to radio reasons) DL


Page Discarded
Page Congestion

GSL Load > 80%

RPP Load > 80%


RPP Congestion

PCU Congestion Rate

Multislot Utilization GPRS

Multislot Utilization EDGE

Maximum Number of TS reservable per TBF

PDCH Allocation Failure Rate

Avg PDCH Allocated in cell

Avg PDCH (with traffic) in cell

DL
Sharing on B, G & E-PDCHs
UL
Sharing on E-PDCHs DL

UL

TBF minute per preempted PDCH in use DL

DL
PDCH Blocking Rate
UL
TBF minutes per inter-RA CRS DL
TBF minutes per intra-RA CRS DL
Formula
(DLBGGTHR + DLTHP1GTHR + DLTHP2GTHR + DLTHP3GTHR) / (DLBGGDATA +
DLTHP1GDATA + DLTHP2GDATA + DLTHP3GDATA)
(ULBGGTHR + ULTHP1GTHR + ULTHP2GTHR + ULTHP3GTHR) / (ULBGGDATA +
ULTHP1GDATA + ULTHP2GDATA + ULTHP3GDATA)

(DLBEGTHR + DLTHP1EGTHR + DLTHP2EGTHR + DLTHP3EGTHR) /


(DLBGEGDATA + DLTHP1EGDATA + DLTHP2EGDATA + DLTHP3EGDATA)
(ULBEGTHR + ULTHP1EGTHR + ULTHP2EGTHR + ULTHP3EGTHR) /
(ULBGEGDATA + ULTHP1EGDATA + ULTHP2EGDATA + ULTHP3EGDATA)

(TBFDLGPRS + TBFDLEGPRS) / 6 / (LDISTFI + LDISRR + LDISOTH + FLUDISC)

(TBFULGPRS + TBFULEGPRS) / 6 / (IAULREL + PREJTFI + PREJOTH)

(DLBGGDATA + DLTHP1GDATA + DLTHP2GDATA + DLTHP3GDATA) /


(DLBGGPFC+ DLTHP1GPFC + DLTHP2GPFC +DLTHP3GPFC)
(ULBGGDATA + ULTHP1GDATA + ULTHP2GDATA + ULTHP3GDATA) /
(ULBGGPFC+ ULTHP1GPFC + ULTHP2GPFC +ULTHP3GPFC)

(DLBGEGDATA + DLTHP1EGDATA + DLTHP2EGDATA + DLTHP3EGDATA) /


(DLBGEGPFC+DLTHP1EGPFC+DLTHP2EGPFC+DLTHP3EGPFC)

(ULBGEGDATA + ULTHP1EGDATA + ULTHP2EGDATA + ULTHP3EGDATA) /


(ULBGEGPFC+ULTHP1EGPFC+ULTHP2EGPFC+ULTHP3EGPFC)

100 * (DLBGEGDATA + DLTHP1EGDATA + DLTHP2EGDATA + DLTHP3EGDATA) /


(DLBGGDATA + DLTHP1GDATA + DLTHP2GDATA + DLTHP3GDATA +
DLBGEGDATA + DLTHP1EGDATA + DLTHP2EGDATA + DLTHP3EGDATA)

100 * (ULBGEGDATA + ULTHP1EGDATA + ULTHP2EGDATA + ULTHP3EGDATA) /


(ULBGGDATA + ULTHP1GDATA + ULTHP2GDATA + ULTHP3GDATA +
ULBGEGDATA + ULTHP1EGDATA + ULTHP2EGDATA + ULTHP3EGDATA)

CS12DLACK / (CS12DLSCHED * 20)

CS12ULACK / (CS12ULSCHED * 20)


(INT10BREGPRSTBF*10 + INT15BREGPRSTBF*15 + INT20BREGPRSTBF*20 +
INT25BREGPRSTBF*25 + INT30BREGPRSTBF*30 + INT35BREGPRSTBF*35 +
INT40BREGPRSTBF*40 + INT45BREGPRSTBF*45 + INT50BREGPRSTBF*50 +
INT55BREGPRSTBF*55) / (INT10BREGPRSTBF + INT15BREGPRSTBF +
INT20BREGPRSTBF + INT25BREGPRSTBF + INT30BREGPRSTBF +
INT35BREGPRSTBF + INT45BREGPRSTBF + INT50BREGPRSTBF +
INT55BREGPRSTBF)
MC19ULACK / (MC19ULSCHED * 20)

100 * LDISRR / (LDISTFI + LDISRR + LDISOTH + FLUDISC)


PAGPCHCONG + PAGETOOOLD
TOTCONGPAG

100 * (GSL8190 + GSL9100) / GSLSCAN


100 * (RPP8190 + RPP9100) / (RPP0040 + RPP4160 + RPP6180 + RPP8190 +
RPP9100)
100 * ALLPDCHPCUFAIL / PCHALLATT

100 * FAILMOVECELL / (SumOfCELLMOVED + FAILMOVECELL)

100 * (MUTILBASIC + MUTILGPRS) / (TRAFF2BTBFSCAN + TRAFF2GTBFSCAN)

100 * (MUTILEGPRS) / (TRAFF2ETBFSCAN)


(4 * (MUTIL14 + MUTIL24 + MUTIL34 + MUTIL44) + 3 * (MUTIL13 + MUTIL23 +
MUTIL33) + 2 * (MUTIL12 + MUTIL22)) / (MUTIL14 + MUTIL24 + MUTIL34 +
MUTIL44 + MUTIL13 + MUTIL23 + MUTIL33 + MUTIL12 + MUTIL22)

100 * PCHALLFAIL / PCHALLATT

ALLPDCHACC / ALLPDCHSCAN

ALLPDCHACTACC / ALLPDCHSCAN
(DLTBFPBPDCH + DLTBFPGPDCH + DLTBFPEPDCH) / (DLBPDCH + DLGPDCH
+ DLEPDCH)
(ULTBFPBPDCH + ULTBFPGPDCH + ULTBFPEPDCH) / (ULBPDCH + ULGPDCH
+ ULEPDCH)

DLTBFPEPDCH / DLEPDCH

ULTBFPEPDCH / ULEPDCH

(TBFDLGPRS + TBFDLEGPRS) / 6 / PREEMPTPDCH

100 * (FAILDLTBFEST / DLTBFEST)


100 * (PREJTFI + PREJOTH) / PSCHREQ
(TBFDLGPRS + TBFDLEGPRS) / 6 / FLUDISC

(TBFDLGPRS + TBFDLEGPRS) / 6 / FLUMOVE


Recommended
threshold (preliminary) Unit Mode
kbit/s GPRS

To set a recommended value, network kbit/s GPRS


trend should be studied. Basically, higher
value is better.
kbit/s EDGE

kbit/s EDGE

To set a recommended value, network


min GPRS + EDGE
trend should be studied. Basically, higher
value is better.

kbit/PFC GPRS

High value indicates high volume data


transfers while low value indicates low
volume data transfers - This is controlled
by user behavior.
kbit/PFC EDGE

Depends on user behavior % EDGE

Depends on user behavior % EDGE

kbit/s GPRS

kbit/s GPRS
kbit/s EDGE

kbit/s EDGE

% GPRS + EDGE
raw number
Value > 0 indicates CCCH capacity
problem.

Value >80% should be investigated. % GPRS + EDGE

Value >80% should be investigated. % GPRS + EDGE


% GPRS + EDGE

% GPRS + EDGE

% GPRS
High utilization indicates need more E-
PDCH. % EDGE

# TS GPRS + EDGE

Value > 15% should be investigated. % GPRS + EDGE


This is an indicator and related to the
number of PDCH defined per cell. # PDCH GPRS + EDGE
This is an indicator and related to
utilization of PDCH. # PDCH GPRS + EDGE

GPRS + EDGE

GPRS + EDGE

If sharing on E-PDCHs > sharing on B, G EDGE


& E-PDCHs, this indicates that more
capacity need for E-PDCH. EDGE
To set a recommended value, network
trend should be studied. Basically, higher
value is better. min GPRS + EDGE

<1% is good % GPRS + EDGE


<1% is good % GPRS + EDGE
To set a recommended value, network min GPRS + EDGE
trend should be studied. Basically, higher
value is better. min GPRS + EDGE
Object
Type
CELLQOSG

CELLQOSG

CELLQOSEG

CELLQOSEG

CELLGPRS2

TRAFDLGPRS
TRAFULGPRS

CELLQOSG

CELLQOSEG

CELLQOSEG

CELLQOSEG

CELLGPRS

CELLGPRS
RLINKBITR

CELLGPRS

CELLGPRS2
CELLPAG
BSC

BSCGPRS

BSCGPRS
BSCGPRS

BSCGPRS

TRAFGPRS2

TRAFGPRS2

TRAFGPRS2

CELLGPRS

CELLGPRS

CELLGPRS

TRAFDLGPRS

TRAFDLGPRS

TRAFDLGPRS

TRAFULGPRS

TRAFDLGPRS
CELLGPRS

CELLGPRS
CELLGPRS2
TRAFDLGPRS

TRAFULGPRS
Remark

Short TBFs (short transfers) will give lower value of IP Throughput as setup time is included. Need to
verify with data volume per PFC.

This formula is equivalent to GSM erlang minutes per drop.

To be used to verify GPRS IP/LLC Throughput.

To be used to verify EDGE IP/LLC Throughput.

Ratio between EDGE data volume compared to all data volume.

the higher is better,but less than than the theorical value of 12kbit/s
Cell level
BSC level

BSC level

BSC level

This is the ratio of TS received compared to TS requested.

E-PDCH capacity

This indicates what MS multislot classes are used in the network.

This is from network point of view if GPRS/EDGE allocation successful high / low

Sharing factor

Sharing factor

E-PDCH capacity

E-PDCH capacity

This is from user point of view who suffers throughput slowdown due to voice traffic increase.

DL TBF setup failure rate on CCCH, PCCCH and PACCH.


UL TBF setup failure rate on RACH, PRACH and PACCH.

Das könnte Ihnen auch gefallen