4 Illegal HDD or ENC are blockaded
Phenomena Illegal HDD or ENC are blockaded when one controller is blockaded.
Severity Medium
Conditions of Occurrence The problem may occur when all following conditions are met.
1. One controller is blockaded
2. SAS backend diagnostic process executed on another controller
3. SAS control LSI reset occurs on another controller
Cause Due to the firmware bug, firmware recognizes different HDD or ENC fails in SAS backend
diagnostic process when SAS control LSI reset occurs.
Affected Products/Version 0832/E or later
Fixed Product/Version Version: 0850/B or later
Category Common
Changed Part MICRO-Disk
HDS Confidential 2 of 4
8 Controller is blockaded with "Micro program error[ISM]"
Phenomena Controller is blockaded with "Micro program error[ISM]" when Qlogic ISCSI HBA
connects to DF800 The message, "Micro program error[ISM]" is displayed.
Severity Medium
Conditions of Occurrence The problem will occur when all following conditions are met.
1. ISCSI Host I/F
2. Qlogic ISCSI HBA
3. Target number is equal or over 174
Cause Due to the firmware bug about ISCSI Host I/O connection process
Affected Products/Version 0843/B or later
Fixed Product/Version Version: 0850/A or later
Category ISCSI
Changed Part MICRO-Disk
10 When the queue full status responds to host, the controller is blockaded.
Phenomena When the queue full status responds to host, the controller is blockaded.
Severity Medium
Conditions of Occurrence 1. High load
2. More than 1400 commands are received at the same time
3. The queue full status responds
Cause Lack of resources generated by internal resource defect when response to command from
the server is delayed, queue full status is generated, and the controller is blockaded
Affected Products/Version 0832/E or later
Fixed Product/Version Version: 0850/B or later
Category Fibre Channel I/F
Changed Part MICRO-Disk
HDS Confidential 3 of 4
12 ENC failure when removing ENC_PK (or ENC cable)
Phenomena Removing ENC_PK (or ENC cable) from the operating DF800 causes other Expander's
error (ENC failure). There is a few potential to occur Subsystem down finally.
Severity High
Conditions of Occurrence ・Removing the ENC_PK (or ENC cable) during transmitting write data to
SATA-HDD with the other path, and Expander cannot transfer "Break",
because Expander's resource is not released.
* There is no problem when removing ENC_PK (or ENC cable) on the failed path.
Cause ・Current setting of Expander is to transfer "Break" via Expander's own FIFO.
(That means Break is not transferred until the data in FIFO is transferred.)
・If Expander's resource (FIFO) is not released due to above condition later access request is
failed and results in the error in both backend path.
*Change the setting of Expander to allow, "Break" to bypass Expander's own FIFO.
Affected Products/Version 0832/Aor later
Fixed Product/Version Version: 0850/B or later
Category Common
Changed Part ENC micro
13 Controller blockaded
Phenomena Controller is blockaded when RST switch on another controller is pushed.
Severity High
Conditions of Occurrence The problem may occur when all following conditions are met.
1. DF800H
2. Forced write through mode is valid.
3. A controller is blockaded
Cause Due to the firmware bug about Reset process
Affected Products/Version 0831/A or later
Fixed Product/Version Version: 0850/C or later
Category Common
Changed Part MICRO-Disk
HDS Confidential 4 of 4