Sie sind auf Seite 1von 7

Food Chemistry 175 (2015) 100–105

Contents lists available at ScienceDirect

Food Chemistry
journal homepage: www.elsevier.com/locate/foodchem

Analytical Methods

Comparison of UPLC and HPLC methods for determination of vitamin C


Inga Klimczak, Anna Gliszczyńska-Świgło ⇑
The Poznań University of Economics, Faculty of Commodity Science, al. Niepodległości 10, 61-875 Poznań, Poland

articleinfo abstract

Article history: Ultra performance liquid chromatography (UPLC) and high-performance liquid chromatography (HPLC)
Received 6 March 2013 methods for determination of ascorbic acid (AA) and total AA (TAA) contents (as the sum of AA and dehy-
Received in revised form 25 October 2014 droascorbic acid (DHAA) after its reduction to AA) in fruit beverages and in pharmaceutical preparations
Accepted 18 November 2014 were compared. Both methods are rapid: total time of analysis was 15 and 6 min for HPLC and UPLC
Available online 26 November 2014 methods, respectively. The methods were validated in terms of linearity, instrument precision, limits
of detection (LOD) and quantification (LOQ), accuracy and recovery. Intra- and inter-day instrument pre-
Keywords: cisions for fruit juices, expressed as RSD, were 2.2% and 2.4% for HPLC, respectively, and 1.7% and 1.9% for
HPLC UPLC, respectively. For vitamin C tablets, inter- and intra-day precisions were 0.4% and 0.5%, respectively
UPLC (HPLC), and 0.5% and 0.3%, respectively (UPLC). Both methods were sensitive: LOD was 0.049 lg/mL for
Vitamin C HPLC and 0.024 lg/mL for UPLC while LOQs were 0.149 and 0.073 lg/mL for HPLC and UPLC, respectively.
Food analysis These methods could be useful in the routine qualitative and quantitative analysis of AA or TAA in phar-
Beverages maceutical preparations or fruit beverages. However, UPLC method is more sensitive, faster and con-
Pharmaceutical preparations sumes less eluent.
© 2014 Elsevier Ltd. All rights reserved.

1. Introduction Vitamin C is the most important water-soluble antioxidant.


Both, ascorbic acid (AA) and its oxidation product, dehydroascorbic
There is an increasing need for fast and ultra-fast separation acid (DHAA), have vitamin C activity. Because humans cannot syn-
methods with good efficiency and resolution. Ultra performance thesise AA, its main sources in the diet are fruits, vegetables and
liquid chromatography (UPLC) has become a widely used tech- their products as well as dietary supplements containing AA. There
nique, which takes full advantages of chromatographic principles are significant variations in vitamin C content in food. For example,
to perform separation, using short columns packed with smaller in fruits it may range from 2–10 mg/100 g in plums and apples up
particles (sub-2 lm). This has led to a shorter analysis time, to 1000–1300 mg/100 g in rosehip and acerola, whereas in fruit
improved peak efficiency (peak width), better resolution and juices, it may range from 0–30 mg/L in apple juice to 280–
decreased use of solvents compared with conventional high-perfor- 860 mg/L in orange juice (Belitz, Grosch, & Schieberle, 2009;
mance liquid chromatography (HPLC) (de Villiers et al., 2006; Davey et al., 2000). Supplements containing vitamins or dietary
Guillarme, Nguyen, Rudaz, & Veuthey, 2007). Moreover, the UPLC minerals are included as a category of food in the Codex Alimentar-
system enables the detection of analytes at very low concentrations ius. Currently, AA is the most widely used vitamin/antioxidant sup-
because of the improved signal-to-noise ratio (Guillarme et al., plement worldwide. It is available as a single compound or in
2007). The injection volume in UPLC can be significantly reduced multi-compound preparations. It is also used in cosmetic and food
without loss of sensitivity (Guillarme, Nguyen, Rudaz, & Veuthey, industry as an antioxidant. Vitamin C in food can be lost, particu-
2008; Spacil, Nováková, & Solich, 2008). However, the use of short larly during thermal processing or storage. Its loss (10–60%) is
columns (50–100 mm), packed with sub-2 lm particles in conven- due to both oxidation and leaching (Combs, 2008). Thus, addition
tional liquid chromatography (LC), are limited by increased column of AA to fortify foods or restore vitamin C losses during processing
back-pressure (>40 MPa) which is not compatible with conven- or storage is common.
tional instrumentation (de Villiers et al., 2006). The necessity of Several analytical methods have been proposed for the determi-
using instrumentation dedicated to UPLC is a limitation of this tech- nation of vitamin C, including titrimetric (Suntornsuk, Gritsanapun,
nique (Guillarme et al., 2007). Nilkamhank, & Paochom, 2002), enzymatic (Shekhovtsova,
Muginova, Luchinina, & Galimova, 2006), chemiluminometric
⇑ Corresponding author. Tel.: +48 61 8569320; fax: +48 61 8543993.
(Pires, Marconi, Meneses, & Zagatto, 2006), spectrophotometric
E-mail address: a.gliszczynska-swiglo@ue.poznan.pl (A. Gliszczyńska-Świgło).
(Llamas, Di Nezio, & Fernández Band, 2011), fluorometric (AOAC,

http://dx.doi.org/10.1016/j.foodchem.2014.11.104
0308-8146/© 2014 Elsevier Ltd. All rights reserved.
I. Klimczak, A. Gliszczyńska-Świgło / Food Chemistry 175 (2015) 100–105 101

2007), and amperometric (Wawrzyniak, Ryniecki, & Zembrzuski, 2. Materials and methods
2005) but separation techniques such as capillary electrophoresis
(Dong et al., 2007), gas chromatography (Silva, 2005) and liquid 2.1. Materials
chromatography (LC) (Nováková, Solich, & Solichová, 2008;
Spínola, Mendes, Cămara, & Castilho, 2012; Tarrago-Trani, Cartons or bottles of commercial fruit beverages (juices and
Phillips, & Cotty, 2012), are regarded as more accurate. Among drinks) were purchased from local markets. Vitamin C pharmaceu-
chromatography techniques, HPLC methods are much more fre- tical preparations were bought in local pharmacy. Bottles of fruit
quently used than gas chromatography. juices (three for each type of juice originating from two different
Many chromatographic methods refer to the determination of batches; n = 6) were stored after opening for 24 and 48 h in the
AA. Some of them are dedicated to the determination of AA and cold (4–6 °C) to assess the effect of time on the concentration of
TAA content as the sum of AA and DHAA after reduction of DHAA DHAA. Meta-phosphoric acid and AA (min 99.7%) were purchased
to AA (Kałuz_ ewicz et al., 2012; Spínola et al., 2012; Tarrago-Trani et from Merck (Darmstadt, Germany), DL-dithiothreitol (DTT; min
al., 2012). This is essential for fruits and vegetables because many 99%) was from Sigma–Aldrich (Steinheim, Germany). Deionized-
harvesting and post-harvest handling procedures promote doubly distilled water was filtered through a 0.45 lm filter for
oxidation or degradation of AA (Hernandez, Lobo, & González, HPLC (Millipore, Bedford, MA, USA). Methanol (Chempur, Piekary Ś
2006; Kałuz_ ewicz et al., 2012; Lee & Kader, 2000). In many plant la˛ skie, Polska) was HPLC grade. All other chemicals were reagent
crops, DHAA may represent up to 10% of total vitamin C and it grade.
tends to increase during storage (Lee & Kader, 2000). However, in
the case of some fruit juices (e.g. stored short-term orange juices),
2.2. Sample preparation
losses due to oxidation can be insignificant (Fernández-García,
Butz, Bognàr, & Tauscher, 2001; Sánchez-Moreno, Plaza, de
The vitamin C extraction method was adapted from Ross (1994).
Ancos, & Cano, 2003). For other types of juices, literature data in
Beverage sample (0.5 mL) and 10% meta-phosphoric acid (0.5 mL)
this respect are limited (Brenes, Del Pozo-Insfran, & Talcott,
were mixed using a vortex (5 min) (final concentration of meta-
2005; González-Molina, Moreno, & García-Viguera, 2009). There-
phosphoric acid was 5%), centrifuged at 8500g for 10 min, and
fore, it is important to determine whether DHAA analysis is neces-
injected onto the HPLC or UPLC column to determine AA content
sary for all type of juices.
(Gliszczyńska-Świgło & Tyrakowska, 2003). Before injection onto
Enhanced sensitivity and separation power of UPLC in compar-
UPLC column, the samples of fruit juices or drinks were diluted
ison to conventional HPLC decreases the time and cost of analysis,
1:50 or 1:10, respectively, using 10% meta-phosphoric acid.
and has become increasingly important in liquid chromatography
The sum of AA and DHAA (vitamin C content; TAA) was deter-
applications. These include analysis of food and plant compounds,
mined after reduction of DHAA to AA using DTT. The juice sample
e.g. vitamins (de Brouwer et al., 2010; Hampel, York, & Allen, 2012;
(0.2 mL) and 5% DTT (0.2 mL) were mixed and diluted to 2 mL with
Spínola et al., 2012), phenolics (Gruz, Novak, & Strnad, 2008;
10% meta-phosphoric acid and injected onto HPLC or UPLC column
Herrero et al., 2011) and alkaloids (Ortega et al., 2010; Yi et al.,
2012). In the fields of food safety, UPLC is used for determination to determine vitamin C (Gliszczyńska-Świgło et al., 2006).
Vitamin C tablets were dissolved in 25 mL 10% meta-phosphoric
of pesticides residues and their metabolites (Leandro, Hancock,
acid and treated as fruit beverages samples. Before injection onto
Fussell, & Keely, 2006; Li et al., 2013), and heterocyclic aromatic
HPLC or UPLC column, the samples of tablets were diluted 1:50 or
amines (Barceló-Barrachina et al., 2006). Major applications of
1:150, respectively, using 10% meta-phosphoric acid. Three
UPLC in pharmaceutical analyses include quality control and sta-
independent extractions were carried out for all samples. The only
bility monitoring of products, drug discovery and development
difference between sample preparation for HPLC and UPLC was the
(Nováková & Vlčková, 2009; Wren & Tchelitcheff, 2006). There
magnitude of sample dilution before injection.
are few methods dedicated solely to vitamin C determination in
foods (Spínola et al., 2012).
Due to the widespread application of vitamin C in food industry, 2.3. Chromatographic determination of AA
and its losses during processing or storage, it is necessary to moni-
tor levels of this compound in food and pharmaceutical prepara- The vitamin C was determined using Waters 600 high-perfor-
tions using low-cost, fast and reliable analytical tools. Sample mance liquid chromatograph (Waters Corp., Milford, MA, USA)
preparation before analysis is crucial to obtain accurate results. equipped with LiChrospher C18 (250 × 4.0 mm, 5 lm, Merck KGaA,
According to literature data, 1–10% meta-phosphoric acid can be Germany) fitted with the same guard column. A gradient of mobile
used to prepare samples for AA determination in beverages, fruits phase composed of methanol (solvent A) and 5 mmol/L KH2PO4, pH
and biological samples (final concentration from 0.2% to 5%) 2.65 (solvent B) was used according to the following program: lin-
(Karlsen, Blomhoff, & Gundersen, 2005; Odriozola-Serrano, ear increment starting with 5–22%A in 6 min and the return to the
Hernández-Jover, & Martín-Belloso, 2007; Tiwari, O’Donnell, initial conditions within the next 9 min with the flow rate of
Muthukumarappan, & Cullen, 2009; Valdramidis, Cullen, Tiwari, & 0.8 mL/min. The eluate was detected using a Waters 996 photodi-
O’Donnell, 2010). The weakness of these methods is incomplete ode array detector set at 245 nm (Gliszczyń ska-Świgło et al.,
data on stability of AA during sample preparation and analysis. 2006). The injection volume was 20 lL.
Therefore, the first aim of the present study was to determine the UPLC determination of vitamin C was done using Acquity™
stability of AA in meta-phosphoric acid used for sample ultra high performance liquid chromatograph equipped with
preparation. ACQUITY UPLC BEH C18 (100 × 2.1 mm; 1.7 lm; Waters, Milford,
MA, USA) fitted with guard column. A gradient of mobile phase
The next aim of this study was to validate and compare UPLC
composed of methanol (solvent A) and 5 mmol/L KH2PO4, pH
and HPLC methods for AA and TAA determination. The validated
2.65 (solvent B) was used according to the following program: lin-
HPLC and UPLC methods were applied to different fruit juices
ear increment starting with 5–15%A in 1 min, from 15% to 35% for
and vitamin supplements. Moreover, the concentration of AA and
the next 1 min and the return to the initial conditions within the
TAA was determined in different fruit juices stored for 24 and
next 4 min with the flow rate of 0.2 mL/min. The eluate was
48 h after opening to verify the necessity of determination of both
detected using a Waters Acquity™ photodiode array detector set
AA and DHAA to assess the concentration of vitamin C in this kind
at 245 nm. The injection volume was 5 lL.
of product.
102 I. Klimczak, A. Gliszczyńska-Świgło / Food Chemistry 175 (2015) 100–105

AA was identified by comparing its retention time and ultravi- concentration of meta-phosphoric acid was 5% or 10% for juices
olet spectrum with that of the AA standard. UV-spectrum was also and tablets, respectively).
used to confirm the purity of AA separated from other possible
compounds present in extract. Quantification of AA or vitamin C 3.2. Analytical characteristics
(as the sum of AA and DHAA) was done using the external standard
method with AA as a standard. For each extract, at least two injec- In this paper, HPLC and UPLC methods for vitamin C determina-
tions were made. tion were compared. AA and DTT were eluted from an HPLC system
The content of DHAA was determined indirectly by subtraction in 4.01 and 13.06 min, respectively. Using UPLC system, retention
of AA from TAA. times of AA and DTT were 1.56 and 3.30 min, respectively
(Fig. 1). Using UPLC method, the total time of analysis was 2.5
2.4. Method validation times shorter than with HPLC and solvent consumption decreased
from 12 to 1.2 mL/min.
Validation of HPLC and UPLC methods included linearity, instru- Analytical characteristics of HPLC and UPLC methods included:
ment precision and sensitivity. Quantification of AA was performed linearity, precision and sensitivity (Table 1). Quantification of AA
using an external standard method. The eight-point (25–300 lg/mL was performed using an external standard method. The curve for
for HPLC and 5–50 lg/mL for UPLC) calibration curves (n = 4; gener- AA in HPLC method was linear to atleast 300 lg/mL. In UPLC
ated during a 6-month period) were prepared with the standard method, lower concentrations must be used: a maximum concen-
solutions of AA in 10% meta-phosphoric acid at concentrations tration cannot be higher than 50 lg/mL. The RSD values of the
spanning those present in samples. standard curve slopes obtained with HPLC and UPLC systems were
Instrument precision was checked from six consecutive injec- 2.78%, 1.82%, respectively. Linear correlation coefficients (r) for
tions of fruit juice and vitamin C tablet extracts prepared as both standard curves were 0.999.
described in Section 2.2. Instrument precision was checked from six consecutive injec-
The LOD and LOQ were calculated from the calibration curve at tions of AA extracts from fruit juice and pharmaceutical prepara-
concentrations from 0.1 to 3 lg/mL (HPLC) or 0.05–3 lg/mL tion. In the case of fruit juice, the intra-day (the daily) and inter-
(UPLC). The following equation was used: day (day-to-day) RSDs obtained using HPLC were 2.2% and 2.4%,
respectively, whereas with UPLC – 1.7% and 1.9%, respectively.
LOD ¼ 3:3×
b r For vitamin C tablets, the intra- and inter-day RSDs obtained using
LOQ ¼ b ;
10×r
HPLC were 0.4% and 0.5%, respectively; with UPLC system – 0.1%
and 0.3%, respectively (Table 1). Precision of AA determination in
where r is the standard deviation of y-intercepts and b is the slope
pharmaceutical preparation using both methods was higher than
of the calibration curve.
obtained for fruit juice. It is probably the effect of less complex
The efficiency of the extraction method was determined by
matrix of tablet than fruit juice.
spiking samples at two concentration levels of AA (50% and 100%
The LOD and the LOQ for AA under HPLC conditions were
of the AA level in the product). Spiked and unspiked samples were
0.049 lg/mL and 0.149 lg/mL, respectively. These results are much
treated in the same way throughout the whole procedure. Three
lower than those reported by Sánchez-Mata, Cămara-Hurtado,
independent extractions were carried out for each product and
Diez-Marquês, and Torija-Isasa (2000), Hernandez et al. (2006)
AA level. Each sample was injected onto the HPLC or UPLC columns
and Vidovic´ et al. (2008) but slightly higher than those reported
twice.
by Valente, Albuquerque, Sanches-Silva, and Costa (2011). In UPLC
method, LOD and LOQ were 0.024 and 0.073 lg/mL, respectively
2.5. Statistical analysis (Table 1). These results are very similar to those obtained by
Spínola et al. (2012) but better than those reported by Zhang,
Statistical analyses were performed using the Statistica 9.0 Chen, Liao, and Ren (2009) as well as by Talekar, Vora, Gawade,
(StatSoft, Inc., 2000) program. Results on the effect of storage time and Gopala (2013). Moreover, the extraction solvent used in the
on the AA and TAA concentrations in juice samples were assessed present study was simpler than that described by Spínola et al.
using ANOVA. Differences between fresh and stored samples were (2012) and guaranteed stability of sample within at least 24 h.
evaluated by the Dunnett’s test. The differences between HPLC and The proposed UPLC method can be an alternative for existing
UPLC results as well as between AA and TAA concentrations in methods for vitamin C determinations in juices and pharmaceuti-
stored fruit beverages were evaluated by the Student’s t test. The cal preparations.
differences at 5% level were considered as significant. The efficiency of the extraction was determined based on the
recovery of AA from spiked juice and tablet samples. It was found
3. Results and discussion that the recovery of AA was not lower than 98.9% (Table 2).

3.1. Stability of AA in meta-phosphoric acid 3.3. Quantification of AA in fruit beverages and vitamin C tablets

The results of our study show that the stability of AA in juice The validated HPLC and UPLC methods were applied to different
samples using 2.5% meta-phosphoric acid (final concentration of fruit juices and vitamin supplements. The content of vitamin C in
meta-phosphoric acid was 1.25%) was significantly less than with tested products is reported in Table 3. DHAA was not present in
10% meta-phosphoric acid (meta-phosphoric acid final concentra- any sample (the results obtained for samples prepared with and
tion of 5%). The concentration of AA in juice samples (n = 6) without DTT were not statistically different). The results obtained
decreased from 252.7 to 232.2 mg/L (8%) in 1 h. In the same time, using HPLC and UPLC methods were very similar although, for
the concentration of AA in tablet samples dissolved in 2.5% meta- some products, the results obtained using UPLC were slightly
phosphoric acid (n = 6) decreased from 62.5 to 46.5 mg/tablet higher than those obtained by HPLC. It may be due to the higher
(26%). Juice or tablet samples dissolved in 10% meta-phosphoric sensitivity of UPLC than HPLC.
acid were more stable. However, after 24 h, at least 97.3% of AA The changes in AA, TAA and DHAA concentrations in different
was still present in juice or tablet samples. Based on these results, opened fruit juices stored for 24 and 48 h under refrigeration con-
10% meta-phosphoric acid was used for sample preparations (final ditions are presented in Table 4. DHAA was not observed in any
I. Klimczak, A. Gliszczyńska-Świgło / Food Chemistry 175 (2015) 100–105 103

A Juice sample B AA
Juice sample with DTT
AA

A245 [a.u.]

A245 [j.u.]
DTT

DTT

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4
Retention time [min] Retention time [min]

Fig. 1. Typical HPLC (A) and UPLC (B) chromatograms of ascorbic acid separated from fruit juice and pharmaceutical preparation.

Table 1 Table 3
Method validation parameters for determination of AA in juices and vitamin C tablets. Comparison of vitamin C content in analysed samples as determined by HPLC and
UPLC methods.
HPLC UPLC
Sample Vitamin C content ± SD (%RSD) (mg/L or mg/
Standard linearity Range (lg/mL) 0–300 0–50
tablet)
r 0.999 0.999
HPLC UPLC
Instrument precision Intra-day
Fruit juices and beverages
(n = 6)
Orange juice 224.3 ± 0.9a (0.4) 230.9 ± 1.8b (0.8)
Juice Mean (mg/L) ± SD 248.2 ± 5.4 255.9 ± 4.3
White grapefruit juice 1 255.6 ± 3.6a (1.4) 267.2 ± 2.4b (0.9)
RSD (%) 2.2 1.7
Red grapefruit juice 2 467.1 ± 1.5a (0.3) 473.7 ± 1.4b (0.3)
Vitamin C tablet Mean (mg/tablet) 67.6 ± 0.3 67.7 ± 0.1 Blackcurrant nectar 209.6 ± 2.7a (1.3) 208.2 ± 2.7a (1.3)
RSD (%) 0.4 0.1 Multifruit drink 1* 86.6 ± 1.3a (1.5) 84.7 ± 0.3a (0.4)
Multifruit drink 2* 87.6 ± 0.6a (0.7) 88.7 ± 0.6a (0.7)
Instrument precision Inter-day Ice Tea drink* 100.0 ± 0.4a (0.4) 97.5 ± 0.9b (0.9)
(n = 6) Vitamin preparations
Juice Mean (mg/L) ± SD 245.5 ± 5.8 253.5 ± 4.9
Multivitamin preparation 64.4 ± 0.3a (0.5) 68.7 ± 1.6b (2.3)
RSD (%) 2.4 1.9
Vitamin C 65.8 ± 0.6a (0.9) 67.7 ± 0.1b (0.1)
Vitamin C tablet Mean (mg/ 65.8 ± 0.3 66.2 ± 0.2 Vitamin C + rutin* 100.0 ± 0.1a (0.1) 99.7 ± 0.4a (0.4)
tablet) ± SD
RSD (%) 0.5 0.3 Values are mean ± SD (at least three independent extractions were carried out for
three products (n = 9) and at least two injections into UPLC or HPLC column were
Limits done for each sample).
Means in each row are significantly different at a = 0.05.
a,b
LOD (lg/mL) 0.049 0.024 *
In accordance with producer declaration.
LOQ (lg/mL) 0.149 0.073

fresh juice (the results obtained for samples prepared with and effect on AA in fortified fruit juices comparing to orange and black-
without DTT were not statistically different). The decrease in AA currant juices. Apple juice phenolic acids were recognised as less
of 0–2.9% and 4.1–6.4% in comparison to fresh juice was observed efficient protectors of AA than flavonoids of orange and blackcur-
for juices stored for 24 and 48 h, respectively. The concentration of rant juices (Miller & Rice-Evans, 1997). These results may explain
DHAA was from 0% to 5.4% depending on storage time and a kind of higher losses of AA in apple juices than in multifruit juices ana-
juice. It was reported that phenolic compounds protect AA from lysed in the present study. It was observed that oxidation process
degradation but this protection depends on the type of compound was only partly responsible for the loss of AA because the concen-
(Miller & Rice-Evans, 1997; Özkan, Kırca, & Cemeroğlu, 2004). tration of DHAA did not compensated the decrease of AA in fresh
Moreover, it was found that apple juice had the lowest protective juice. This was especially apparent for multifruit juices, in which

Table 2
Recovery of AA from selected fruit beverages and pharmaceutical preparation.
Product AA content ± SD (mg/L) or (mg/tablet) AA spiked levela (%) Recoveryb (%)

HPLC UPLC HPLC UPLC

Grapefruit juice 468.3 ± 0.8 454.2 ± 0.5 50 99.8 ± 0.3 99.9 ± 0.2
100 100.2 ± 0.2 100.0 ± 0.1

Blackcurrant nectar 208.1 ± 07 209.2 ± 0.7 50 99.0 ± 0.7 99.3 ± 0.4


100 98.9 ± 0.6 99.5 ± 0.5

Vitamin C supplement 100.1 ± 0.1 99.8 ± 0.2 50 99.9 ± 0.3 99.9 ± 0.2
100 99.8 ± 0.4 99.8 ± 0.3
a
Percent of AA content in product.
b
Recovery mean ± SD (n = 3 in each level).
104 I. Klimczak, A. Gliszczyńska-Świgło / Food Chemistry 175 (2015) 100–105

Table 4
The changes in vitamin C content in fruit juices (mg/L) during short-term storage under refrigeration conditions.

Product Storage (h) AA1 TAA DHAA2

Multifruit juice 1 0 392.3 ± 3.9a 394.2 ± 2.7a 0


24 381.1 ± 4.8A,a 389.2 ± 1.5A,b 8.1 ± 3.7
(2.9%) (1.3%) (2.1%)
48 376.1 ± 1.5A,a 386.9 ± 2.0A,b 10.8 ± 2.2
(4.1%) (1.9%) (2.8%)
Multifruit juice 2 0 435.8 ± 4.0a 433.1 ± 2.1a 0
24 428.4 ± 1.4a 429.4 ± 1.7a 0
48 414.4 ± 2.3A,a 426.2 ± 2.9A,b 11.8 ± 2.9
(4.9%) (1.6%) (2.7%)
Apple juice 1* 0 254.6 ± 6.7a 251.2 ± 2.2a 0
24 247.2 ± 1.5a 245.8 ± 3.1a 0
48 238.3 ± 4.9A,a 251.9 ± 1.1b 13.6 ± 3.5
(6.4%) (5.4%)
Apple juice 2* 0 360.3 ± 1.6a 357.5 ± 2.5a 0
24 354.2 ± 2.9A,a 360.3 ± 3.9a 0
(1.7%)
48 340.8 ± 1.5A,a 353.0 ± 2.2b 12.2 ± 2.3
(5.4%) (3.4%)

Values are mean ± SD (three juices from two different batches were analysed; at least three independent extractions were carried out for each bottle of product (n = 18) and at
least two injections into column were done for each sample).
Means in the column for AA or TAA are significantly different from appropriate fresh sample (Dunnett’s test, a = 0.05).
A

Means in each row are significantly different (Student’s t test, a = 0.05).


a,b

1
In parenthesis – the loss of AA in comparison with fresh juice.
2
Calculated as the difference between TAA and AA; in parenthesis – the percentage of TAA.
*
Enriched with ascorbic acid (according to the producer declaration).

probably not only oxidation but also degradation of AA occurred. Combs, G. F. (2008). The vitamins fundamental aspects in nutrition and health.
Amsterdam, Boston, Heidelberg, London, New York, Oxford, Paris, San Diego,
The changes in the concentration of AA in apple juices were mainly
San Francisco, Singapore, Sydney, Tokyo: Elsevier, Academic Press.
due to the oxidation thus the decrease in TAA during storage was Davey, M. W., Van Montagu, M., Inzé, D., Sanmartin, M., Kanellis, A., Smirnoff, N.,
not observed. Determination of vitamin C in fruit juices stored et al. (2000). Plant L-ascorbic acid: Chemistry, function, metabolism,
for at least 24 h under refrigeration may require determination of bioavailability and effects of processing. Journal of the Science of Food and
Agriculture, 80, 825–860.
TAA because oxidation of AA may occur during storage. de Brouwer, V., Storozhenko, S., Stove, C. P., van Daele, J., van der Straeten, D., &
Lambert, W. E. (2010). Ultra-performance liquid chromatography–tandem mass
4. Conclusions spectrometry (UPLC–MS/MS) for the sensitive determination of folates in rice.
Journal of Chromatography B, Analytical Technologies in the Biomedical and Life
Sciences, 878, 509–513.
Although many methods have been developed for determina- de Villiers, A., Lestremau, F., Szucs, R., Gelebart, S., David, F., & Sandra, P. (2006).
tion of AA or TAA, both HPLC and UPLC methods proposed in this Evaluation of ultra performance liquid chromatography. Part I: Possibilities and
limitations. Journal of Chromatography A, 1127, 60–69.
study for determination of AA or TAA (vitamin C) in fruit beverages Dong, S., Zhang, S., Cheng, X., He, P., Wang, Q., & Fang, Y. (2007). Simultaneous
and pharmaceutical preparations can be recommended as rapid, determination of sugars and ascorbic acid by capillary zone electrophoresis
precise and sensitive. Extraction of AA and DHAA from tested prod- with amperometric detection at carbon paste electrode modified with
polyethylene glycol and Cu 2O. Journal of Chromatography A, 1161, 327–333.
ucts using 10% meta-phosphoric acid guaranteed determination of Fernández-García, A., Butz, P., Bognàr, A., & Tauscher, B. (2001). Antioxidative
vitamin C within 24 h without its essential loss. For fresh commer- capacity, nutrient content and sensory quality of orange juice and an orange–
cial beverages as well as for pharmaceutical preparations, it is not lemon–carrot juice product after high pressure treatment and storage in
different packaging. European Food Research and Technology, 213, 290–296.
necessary to determine both AA and DHAA. Determination of vita-
Gliszczyńska-Świgło, A., & Tyrakowska, B. (2003). Quality of commercial apple
min C in stored fruit juices may require determination of TAA juices evaluated on the basis of the polyphenol content and the TEAC
because oxidation of AA may occur during storage. Both methods antioxidant activity. Journal of Food Science, 68, 1844–1849.
Gliszczyńska-Świgło, A., Ciska, E., Pawlak-Lemańska, K., Chmielewski, J., Borkowski,
can be useful in the routine qualitative and quantitative analysis
T., & Tyrakowska, B. (2006). The changes in the content of health-promoting
of vitamin C in beverages and pharmaceutical preparations. How- compounds and antioxidant activity of broccoli upon domestic processing. Food
ever, UPLC method is faster, more sensitive, consumes less eluent Additives and Contaminants, 23, 1088–1098.
and it is more eco-friendly than the conventional HPLC method. González-Molina, E., Moreno, D. A., & García-Viguera, C. (2009). A new drink rich in
healthy bioactives combining lemon and pomegranate juices. Food Chemistry,
In consequence, UPLC is cheaper than HPLC because a higher num- 115, 1364–1372.
ber of analyses per unit of time can be performed and consumption Gruz, J., Novak, O., & Strnad, M. (2008). Rapid analysis of phenolic acids in beverages
of eluent is much lower. by UPLC–MS/MS. Food Chemistry, 111, 789–794.
Guillarme, D., Nguyen, D. T.-T., Rudaz, S., & Veuthey, J.-L. (2007). Recent
developments in liquid chromatography – Impact on qualitative and
References quantitative performance. Journal of Chromatography A, 1149, 20–29.
Guillarme, D., Nguyen, D. T.-T., Rudaz, S., & Veuthey, J.-L. (2008). Method transfer for
fast liquid chromatography in pharmaceutical analysis: Application to short
AOAC. (2007). Official methods of analysis. Method 967.21 vitamin C (total) in food.
columns packed with small particle. Part II: Gradient experiments. European
Washington: Association of Official Analytical Chemists, pp. 24–25.
Journal of Pharmaceutics and Biopharmaceutics, 68, 430–440.
Barceló-Barrachina, E., Moyano, E., Galceran, M. T., Lliberia, J. L., Bagó, B., & Cortes,
Hampel, D., York, E. R., & Allen, L. H. (2012). Ultra-performance liquid
M. A. (2006). Ultra-performance liquid chromatography–tandem mass
chromatography tandem mass-spectrometry (UPLC–MS/MS) for the rapid,
spectrometry for the analysis of heterocyclic amines in food. Journal of
simultaneous analysis of thiamin, riboflavin, flavin adenine dinucleotide,
Chromatography A, 1125, 195–203.
nicotinamide and pyridoxal in human milk. Journal of Chromatography B, 903,
Belitz, H.-D., Grosch, W., & Schieberle, P. (2009). Food chemistry. Berlin, Heidelberg:
7–13.
Springer.
Hernandez, Y., Lobo, M. G., & González, M. (2006). Determination of vitamin C in
Brenes, C. H., Del Pozo-Insfran, D., & Talcott, S. T. (2005). Stability of copigmented
tropical fruits: A comparative evaluation of methods. Food Chemistry, 96, 654–
anthocyanins and ascorbic acid in a grape juice model system. Journal of
664.
Agricultural and Food Chemistry, 53, 49–56.
I. Klimczak, A. Gliszczyńska-Świgło / Food Chemistry 175 (2015) 100–105 105

Herrero, M., Temirzoda, T. N., Segura-Carreterob, A., Quirantes, R., Plaza, M., & Sánchez-Moreno, C., Plaza, L., de Ancos, B., & Cano, M. P. (2003). Vitamin C,
Ibañez, E. (2011). New possibilities for the valorization of olive oil by-products. provitamin A carotenoids, and other carotenoids in high-pressurized orange
Journal of Chromatography A, 1218, 7511–7520. juice during refrigerated storage. Journal of Agricultural and Food Chemistry, 51,
Kałuz_ ewicz, A., Gliszczyńska-Świgło, A., Klimczak, I., Lisiecka, J., Tyrakowska, B., & 647–653.
Knaflewski, M. (2012). The influence of short-term storage on the content of Shekhovtsova, T. N., Muginova, S. V., Luchinina, J. A., & Galimova, A. Z. (2006).
flavonoids and vitamin C in broccoli. European Journal of Horticultural Science, 3, Enzymatic methods in food analysis: Determination of ascorbic acid. Analytica
137–143. Chimica Acta, 573–574, 125–132.
Karlsen, A., Blomhoff, R., & Gundersen, T. E. (2005). High-throughput analysis of Silva, F. O. (2005). Total ascorbic acid determination in fresh squeezed orange juice
vitamin C in human plasma with the use of HPLC with monolithic column and by gas chromatography. Food Control, 16, 55–58.
UV-detection. Journal of Chromatography B, 824, 132–138. Spacil, Z., Nováková, L., & Solich, P. (2008). Analysis of phenolic compounds by high
Lee, S. K., & Kader, A. A. (2000). Preharvest and postharvest factors influencing performance liquid chromatography and ultra performance liquid
vitamin C content of horticultural crops. Postharvest Biology and Technology, 20, chromatography. Talanta, 76, 189–199.
207–220. Spínola, V., Mendes, B., Cămara, J. S., & Castilho, P. C. (2012). An improved and fast
Leandro, C. C., Hancock, P., Fussell, R. J., & Keely, B. J. (2006). Comparison of ultra- UHPLC–PDA methodology for determination of L-ascorbic and dehydroascorbic
performance liquid chromatography and high-performance liquid acids in fruits and vegetables. Evaluation of degradation rate during storage.
chromatography for the determination of priority pesticides in baby foods by Analytical and Bioanalytical Chemistry, 403, 1049–1058.
tandem quadrupole mass spectrometry. Journal of Chromatography A, 1103, 94– Suntornsuk, L., Gritsanapun, W., Nilkamhank, S., & Paochom, A. (2002). Quantitation
101. of vitamin C content in herbal juice using direct titration. Journal of
Li, M., Liua, X., Donga, F., Xua, J., Kong, Z., Lia, Y., et al. (2013). Simultaneous Pharmaceutical and Biomedical Analysis, 28, 849–855.
determination of cyflumetofen and its main metabolite residues in samples of Tarrago-Trani, M. T., Phillips, K. M., & Cotty, M. J. (2012). Matrix-specific method
plant and animal origin using multi-walled carbon nanotubes in dispersive validation for quantitative analysis of vitamin C in diverse foods. Journal Food
solid-phase extraction and ultrahigh performance liquid chromatography– Composition and Analysis, 26, 12–25.
tandem mass spectrometry. Journal of Chromatography A, 1300, 95–103. Talekar, U., Vora, D. N., Gawade, S., & Gopala, A. (2013). Development and
Llamas, N. E., Di Nezio, M. S., & Fernández Band, B. S. (2011). Low-injection validation of simultaneous determination of organic acid in fruit juices of
spectrophotometric method with on-line photodegradation for determination Citrus medica L. by RP-UHPLC. Indo American Journal of Pharmaceutical Research,
of ascorbic acid and total sugars in fruit juices. Journal of Food Composition and 3, 7146–7154.
Analysis, 24, 127–130. Tiwari, B. K., O’Donnell, C. P., Muthukumarappan, K., & Cullen, P. J. (2009). Ascorbic
Miller, N. J., & Rice-Evans, C. A. (1997). The relative contributions of ascorbic acid acid degradation kinetics of sonicated orange juice during storage and
and phenolic antioxidants to the total antioxidant activity of orange and apple comparison with thermally pasteurised juice. LWT – Food Science and
fruit juices and blackcurrant drink. Food Chemistry, 60, 331–337. Technology, 42, 700–704.
Nováková, L., & Vlčková, H. (2009). A review of current trends and advances in Valdramidis, V. P., Cullen, P. J., Tiwari, B. K., & O’Donnell, C. P. (2010). Quantitative
modern bio-analytical methods: Chromatography and sample preparation. modelling approaches for ascorbic acid degradation and non-enzymatic
Analytica Chimica Acta, 656, 8–35. browning of orange juice during ultrasound processing. Journal of Food
Nováková, L., Solich, P., & Solichová, D. (2008). HPLC methods for simultaneous Engineering, 96, 449–454.
determination of ascorbic and dehydroascorbic acids. Trends in Analytical Valente, A., Albuquerque, T. G., Sanches-Silva, A., & Costa, H. S. (2011). Ascorbic acid
Chemistry, 27, 942–958. content in exotic fruits: A contribution to produce quality data for food
Odriozola-Serrano, I., Hernández-Jover, T., & Martín-Belloso, O. (2007). Comparative composition databases. Food Research International, 44, 2237–2242.
evaluation of UV-HPLC methods and reducing agents to determine vitamin C in Vidović, S., Stojanović, B., Veljković, J., Pražić-Arsić, L., Roglić, G., & Manojlović, D.
fruits. Food Chemistry, 105, 1151–1158. (2008). Simultaneous determination of some water-soluble vitamins and
Ortega, N., Romero, M.-P., Marcià, A., Reguant, J., Anglès, N., Morelló, J.-R., et al. preservatives in multivitamin syrup by validated stability-indicating high-
(2010). Comparative study of UPLC–MS/MS and HPLC–MS/MS to determine performance liquid chromatography method. Journal of Chromatography A,
procyanidins and alkaloids in cocoa samples. Journal of Food Composition and 1202, 155–162.
Analysis, 23, 298–305. Wawrzyniak, Z., Ryniecki, A., & Zembrzuski, W. (2005). Application of voltammetry
Özkan, M., Kırca, A., & Cemeroğlu, B. (2004). Effects of hydrogen peroxide on the to determine vitamin C in apple juices. Acta Scientiarum Polonorum, Technologia
stability of ascorbic acid during storage in various fruit juices. Food Chemistry, Alimentaria, 4, 5–16.
88, 591–597. Wren, S. A. C., & Tchelitcheff, P. (2006). Use of ultra-performance liquid
Pires, C. K., Marconi, L. M. T., Meneses, S. R. P., & Zagatto, E. A. G. (2006). A multi- chromatography in pharmaceutical development. Journal of Chromatography
pumping flow system for chemiluminometric determination of ascorbic acid in A, 1119, 140–146.
powdered materials for preparation of fruit juices. Microchemical Journal, 83, 70– Yi, L., Liang, Z.-T., Peng, Y., Yao, X., Chen, H.-B., & Zhao, Z.-Z. (2012). Tissue-specific
74. metabolite profiling of alkaloids in Sinomenii Caulis using laser microdissection
Ross, M. (1994). Determination of ascorbic acid and uric acid in plasma by high and liquid chromatography–quadrupole/time of flight-mass spectrometry.
performance liquid chromatography. Journal of Chromatography B, 657, 197– Journal of Chromatography A, 1248, 93–103.
200. Zhang, H., Chen, S., Liao, W., & Ren, Y. (2009). Fast simultaneous determination of
Sánchez-Mata, M. C., Cămara-Hurtado, M., Diez-Marquês, C., & Torija-Isasa, M. E. multiple water-soluble vitamins and vitamin like compounds in infant formula
(2000). Comparison of high-performance liquid chromatography and by UPLC–MS/MS. Journal of Food, Agriculture and Environment, 7, 88–93.
spectrofluorimetry for vitamin C analysis of green beans (Phaseolus vulgaris
L.). European Food Research and Technology, 210, 220–225.

Das könnte Ihnen auch gefallen