LUMINOUS UV PROTECTED FR PVC WIRE SPECIFICATION

DOC: LUM_UV PROTECTED_FR PVC WIRE


Length of coil : 90 meter for 0.50 to 6.00 Sq. mm. and 100 meter for [(As per IEC 60227 / IS : 694 -1990 & ASTM G154-00a)
10 & 16 Sq. mm. (IEC 60502 / IS 1554 (Pt I & II) )] Date: 12-05-2015, Rev-00
COPPER INSULATION FINISH GOOD
Wire size Current Insulation
Mini. No. of Avg. Min. Copper Mini. Max. Copper Approx.
Sr.No.
(Sq. mm.) copper strand Dia. After
Min. Copper Wt. Brightness
Annealing Resistance at 20
Carrying Thickness Min. Insulation PVC Min. Total Wt.
Over All Dia.
Applications Colour Outer Surface Eccentricity Coiling Packing
(Kg./coil) of copper Capacity Nominal Wt. (Kg./coil.) Property (Kg/coil)
strands insulation (mm.) in % °C (Ohm/Km) (mm.)
(Amp.) (mm.)

1 ** 0.50 16 0.188 0.356 Bright 15% 39.00 4 0.6 0.415 0.771 2.21
2 ** 0.75 24 0.188 0.533 Bright 15% 26.00 7 0.6 0.470 1.003 2.41
3 ** 1.00 32 0.188 0.711 Bright 15% 19.50 12 0.7 0.603 1.314 2.80 SHLs, Street lights
4 ** 1.50 30 0.235 1.042 Bright 20% 13.30 16 0.7 0.648 1.689 3.03
5 ** 2.50 50 0.235 1.736 Bright 20% 7.98 22 0.8 0.921 2.657 3.68

Module Inter-connections, DC connection


6 ** 4.00 56 0.282 2.800 Bright 23% 4.95 29 0.8 1.185 3.985 4.25 in small rating solutions, AC/load Smooth as
As per As per As per As per
connections up to 2KW solutions per
UV Luminous Luminous Luminous Luminous
Luminous
Protected standard standard standard standard
DC connections between SPV array to standard
FR PVC (Golden (Golden (Golden (Golden
7 ** 6.00 84 0.282 4.199 Bright 23% 3.30 37 0.8 1.485 5.685 4.93 DCDB/PCU in 1KW and above solutions, (Golden
sample) sample) sample) sample)
AC/load connections in 3-6KW Systems sample)

DC connections between SPV array to


8 ** 10.00 140 0.287 8.031 Bright 23% 1.91 51 1.0 2.324 10.355 6.10 DCDB/PCU in 1KW and above solutions,
AC/load connections 5 to 10KW Systems

DC connections between SPV array to


9 ** 16.00 226 0.284 12.721 Bright 23% 1.21 68 1.0 2.807 15.528 7.17 DCDB/PCU in 5KW and above solutions,
AC connections in >10KW Systems

Note: - 1:- UV PROTECTED FR PVC wire meets the all requirements of [ IEC 60227 / IS : 694 / ( IEC 60502 / IS 1554 (Pt I & II ) ]. 2:- Required UV certification / test report from BIS / NABL accredited laboratory and CE Certification.

Construction:- Copper confirms to IS: 8130:1984 & PVC confirms to IS: 5831:1984

Conductor: Electrolytic grade, Copper purity 99.99 %, bright annealed multi strand bunch copper conductor as per IS: 8130.

**Conductor as per class 5 of IS: 8130.

Insulation: Double layer insulation with UV Protected FR property (Test Qualify as per ASTM G154-00 a). Oxygen Index more than. 30%

Inner – UV Protected FR PVC compound.

Outer - Skin colour coated UV Protected FR PVC.

Colour - Red & Black

Standards: IEC 60227 / IS : 694 / ( IEC 60502 / IS 1554 (Pt I & II ), IS 8130, & IS 5831.

Size: 0.5 sq. mm to 16.0 sq. mm.

Packing: Length for 0.50 to 6.00 Sq. mm. in 90 mtr coil and for 10.00 & 16.00 in 100 meter coil.

Printing :- Print Month / Year (M/Y) code on the wire with printing content UV protected FR PVC wire.
Prepared By: Approved By:
Sunil Kumar Vijay Prasad
AM. - Quality (HEB) DGM- Engg.(R&D -HEB)