Sie sind auf Seite 1von 2

10/6/2015 Set CHR Transmission Configuration (SET CHRTRMCFG)

Set CHR Transmission Configuration (SET CHRTRMCFG)
Function
Note
Parameters
Example

Function

SET CHRTRMCFG is used to set the configuration information about the CHR transmission function.
You can run this command to set the status of the CHR transmission switch and configure related
transmission parameters during the system configuration.

When the CHR transmission function is disabled and the CHR offline collection function is
enabled, the CHRs are saved in the
/opt/HUAWEI/cgp/workshop/omu/share/export/pm/CHR directory.
When the CHR transmission function and the CHR offline collection function are both
enabled, the CHRs are saved in the
/opt/HUAWEI/cgp/workshop/omu/share/export/pm/CacheCHR directory.

Note

The CHR offline collection function can be enabled or disabled only when the CHR
transmission function is disabled.
The CHR transmission information can be queried by LST CHRTRMCFG.
When the CHR transmission function and the CHR offline collection function are disabled,
the OMU discards the CHRs.
When the CHR transmission function is enabled and the CHR buffer function is disabled,
CHRs are discarded if the OMU is disconnected to the Genex server.

Parameters

Parameter
Parameter ID Name Parameter Description
TRANSMIT CHR This parameter specifies the status of the CHR transmission
transmission switch.
switch Value:
OFF(Off)
ON(On)
No default value
NOTE: The initial value is OFF(Off).

COLLECTIONSWITCH CHR This parameter specifies whether to enable the CHR offline


collection collection function. The rule for setting this parameter is as
flag follows: This parameter can be specified only when the CHR
transmission function is disabled.
Value:
NO(No)
YES(Yes)
Default value: NO(No)
Note: The initial value is NO(No).

IPADDRESS Genex This parameter specifies the IP address of the Genex server.


server IP Value: IP address
address
No default value

http://127.0.0.1:52199/hedex/pages/31186318/04/31186318/04/resources/en/cnup/reference/mml/cgp/Document/set_chrtrmcfg.html 1/2
10/6/2015 Set CHR Transmission Configuration (SET CHRTRMCFG)

PORT Genex This parameter specifies the port number of the Genex server.


server port Value range: 0­65535
Default value: 8003

STORESWITCH CHR store This parameter specifies whether to buffer CHRs.


flag Value:
NO(No)
YES(Yes)
Default value: NO(No)

Example

1.  To enable the CHR transmission function, CHR buffer function, and set the IP address and
port number of the Genex server to 167.1.0.1 and 8003 respectively, run the following
command:
SET CHRTRMCFG: TRANSMIT=ON, IPADDRESS="167.1.0.1", PORT=8003,
STORESWITCH=YES;
2.  To disable the CHR transmission function and enable the CHR offline collection function,
run the following command:
SET CHRTRMCFG: TRANSMIT=OFF, COLLECTIONSWITCH=YES;

Parent topic: CHR Transmission Management

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.

http://127.0.0.1:52199/hedex/pages/31186318/04/31186318/04/resources/en/cnup/reference/mml/cgp/Document/set_chrtrmcfg.html 2/2

Das könnte Ihnen auch gefallen