Ready-to-use configuration

Current differential - With distance backup, 1/3 pole autoreclose and check synchronising P543 M
Nominal auxiliary voltage
24 - 32 Vdc 9
48 - 110 Vdc 2
110 - 250 Vdc (100 - 240 Vac) 3

In/Vn rating
In = 1A/5A ; Vn = 100-120Vac 1
IEC61869/9-2LE Sampled Values, Red. Eth PRP, Dual IP, 2x LC ports + 1 RJ45 port B
IEC61869/9-2LE Sampled Values, Red. Eth PRP, Dual IP, 3x RJ45 ports C
Hardware options
Standard - None 1
IRIG-B Only (Modulated) 2
Second Rear Comms 7
IRIG-B (Modulated) + Second Rear Comms 8
InterMiCOM + Courier Rear Port E
InterMiCOM + Courier Rear Port + IRIG-B modulated F
Redundant Ethernet RSTP, 2 multi-mode ST fibre ports + Modulated IRIG-B J
Redundant Ethernet RSTP, 2 multi-mode ST fibre ports + Un-modulated IRIG-B K
Redundant Ethernet Parallel Redundancy Protocol (PRP), 2 multimode ST fibre ports + Un-modulated IRIG-B P
Redundant Ethernet (100Mbit/s) PRP or HSR or RSTP and Dual IP, 2 LC ports + 1 RJ45 port + Modulated/Un-modulated IRIG-B + IEEE1588 Q
Redundant Ethernet (100Mbit/s) PRP or HSR or RSTP and Dual IP, 3 RJ45 ports + Modulated/Un-modulated IRIG-B + IEEE1588 R
Ethernet (100Mbit/s), 1 RJ45 port + Modulated/Un-modulated IRIG-B + IEEE1588 S

Product Options
Ch1=850nm multi-mode, Ch2=850nm multi-mode, 16inputs & 14stn outputs A
Ch1=1300nm single-mode, Ch2=not fitted (2 Terminal only), 16inputs & 14stn outputs B
Ch1=1300nm single-mode, Ch2=1300nm single-mode, 16inputs & 14stn outputs C
Ch1=1300nm multi-mode, Ch2=1300nm multi-mode, 16inputs & 14stn outputs E
Ch1=1550nm single-mode, Ch2=1550nm single-mode, 16inputs & 14stn outputs G
Ch1=850nm multi-mode, Ch2=1300nm single-mode, 16inputs & 14stn outputs H
Ch1=1300nm single-mode, Ch2=850nm multi-mode, 16inputs & 14stn outputs L
Ch1=1300nm multi-mode, Ch2=1300nm multi-mode, 16inputs & 24stn outputs P
Ch1=1550nm single-mode, Ch2=850nm multi-mode, 16inputs & 14stn outputs R
Ch1=850nm multi-mode, Ch2=850nm multi-mode, 16 inputs & 7stn+4hb outputs S
Ch1=1300nm single-mode, Ch2=not fitted (2 Terminal only), 16 inputs & 7stn+4hb outputs T
Ch1=1300nm single-mode, Ch2=1300nm single-mode, 16 inputs & 7stn+4hb outputs U
Ch1=1300nm multi-mode, Ch2=1300nm multi-mode, 16 inputs & 7stn+4hb outputs W
Ch1=1550nm single-mode, Ch2=1550nm single-mode, 16 inputs & 7stn+4hb outputs Z
Ch1=850nm multi-mode, Ch2=1300nm single-mode, 16 inputs & 7stn+4hb outputs 0
Ch1=1300nm single-mode, Ch2=850nm multi-mode, 16 inputs & 7stn+4hb outputs 3
Ch1=1550nm single-mode, Ch2=850nm multi-mode, 16 inputs & 7stn+4hb outputs 5
Ch1=850nm multi-mode, Ch2=850nm multi-mode, 16inputs & 24stn outputs I
Ch1=1300nm single-mode, Ch2=not fitted (2 Terminal only), 16inputs & 24stn outputs N
Ch1=1300nm single-mode, Ch2=1300nm single-mode, 16inputs & 24stn outputs O
Ch1=1550nm single-mode, Ch2=1550nm single-mode, 16inputs & 24stn outputs Q
Ch1=850nm multi-mode, Ch2=1300nm single-mode, 16inputs & 24stn outputs 6
Ch1=1300nm single-mode, Ch2=850nm multi-mode, 16inputs & 24stn outputs 7
Ch1=1550nm single-mode, Ch2=850nm multi-mode, 16inputs & 24stn outputs 8

Protocol options
K-Bus with simple password management - CSL0 1
IEC 60870-5-103 (VDEW) with simple password management - CSL0 3
DNP3.0 with simple password management - CSL0 4
IEC61850 Edition 1 / 2 and Courier via rear K-Bus/RS485 with simple password management - CSL0 6
IEC 61850 Edition 1 / 2 and CS103 via rear port RS485 with simple password management - CSL0 7
DNP3 over Ethernet with Courier rear port K-Bus/RS485 protocol with simple password management - CSL0 8
IEC61850 Edition 1 / 2 and DNP3 serial with simple password management - CSL0 9
IEC61850 Edition 1 / 2 and DNP3 over Ethernet and DNP3.0 via rear RS485 with simple password management - CSL0 B
IEC61850 Edition 1 / 2 and Courier via rear K-Bus/RS485 with advanced Cyber Security - CSL1 - Security Adminstration Tool (SAT) Required G
IEC61850 Edition 1 / 2 and CS103 via rear port RS485 with advanced Cyber Security - CSL1 - Security Adminstration Tool (SAT) Required H
IEC61850 Edition 1 / 2 and DNP3 serial with advanced Cyber Security - CSL1 - Security Adminstration Tool (SAT) Required J

L
IEC61850 Edition 1 / 2 and DNP3 over Ethernet and DNP3.0 via rear RS485 with advanced Cyber Security - CSL1 - Security Adminstration Tool (SAT) Required

Mounting
Flush / Panel mounting M

Language
English, French, German, Spanish 0
English, French, German, Russian 5
Chinese, English or French via HMI, with English or French only via Communications port C

Software version
Without Distance **
With Distance **

Customer specific options


Standard version 8

Hardware version
Phase 3 Extended CPU M
Phase 2 Extended CPU K

02/03/2020 2/11
Order form configurator MiCOM P543
Ready-to-use configuration

1-4 5 6 7 8 9 10 11 12-13 14 15

Current Differential Protection with 3-pole Autoreclose,


P543 9 1 1 B 3 M 0 K1 8 M
Check Synchronising and Distance Back-Up
SAP PART NUMBER E543911B3M0K18M
Design Suffix
M : CPU3/XCPU3 M
K : XCPU2, With Function Key,Tri-colour LEDs & IEC61850 and other communications Options
Software
K1 : With Distance
H9 : With Distance
H7 : With Distance
H6 : With Distance
H4 : With Distance K1
D3 : With Distance
D2 : With Distance
D1 : With Distance
D0 : With Distance
C0 : Without Distance
Vx Aux Rating
24 - 32 Vdc
48 - 110 Vdc 9
110 - 250 Vdc (100 - 240 Vac)
In/Vn Rating
In = 1A/5A ; Vn = 100-120Vac
IEC61869/9-2LE Sampled Values, Red. Eth PRP, Dual IP, 2x LC ports + 1 RJ45 port 1
IEC61869/9-2LE Sampled Values, Red. Eth PRP, Dual IP, 3x RJ45 ports
Hardware Options
Standard - None
IRIG-B only (Modulated)
InterMiCOM + Courier Rear Port
InterMiCOM + Courier Rear Port + IRIG-B modulated 1
Redundant Ethernet (100Mbit/s) PRP or HSR or RSTP and Dual IP, 2 LC ports + 1 RJ45 port + Modulated/Un-modulated IRIG-B + IEEE1588
Redundant Ethernet (100Mbit/s) PRP or HSR or RSTP and Dual IP, 3 RJ45 ports + Modulated/Un-modulated IRIG-B + IEEE1588
Ethernet (100Mbit/s), 1 RJ45 port + Modulated/Un-modulated IRIG-B + IEEE1588
Product Options - 1
16inputs and 14 standard-outputs
16inputs & 7 standard + 4 high break-outputs
16inputs & 24 standard-outputs
Product Options - 2
Ch1=850nm multi-mode, Ch2=850nm multi-mode
Ch1=1300nm single-mode, Ch2=not fitted (2 Terminal only) B
Ch1=1300nm single-mode, Ch2=1300nm single-mode
Ch1=1300nm multi-mode, Ch2=1300nm multi-mode
Ch1=1550nm single-mode, Ch2=1550nm single-mode
Ch1=850nm multi-mode, Ch2=1300nm single-mode
Ch1=1300nm single-mode, Ch2=850nm multi-mode
Ch1=1550nm single-mode, Ch2=850nm multi-mode
Protocol/Communications Options
Courier with simple password management - CSL0
IEC 60870-5-103 (VDEW) with simple password management - CSL0
DNP3.0 serial via rear RS485 with simple password management - CSL0 3

Mounting Option
Flush Panel Mounting M
Language
Multilingual - English, French, German, Spanish
Multilingual - English, French, German, Russian 0
Chinese, English or French via HMI, with English or French only via Communications port
Customisation
Default 8
Customer

02/03/2020
Master Text

P543911B3M0K18M

Current differential - With distance backup, 1/3 pole autoreclose and check synchronising

Vx Nominal Auxiliary Voltage :


24 - 32Vdc
Vn Nominal Voltage :
100 -120Vac
Hardware Options :
Standard - None
Communications Options :
IEC 60870-5-103 (VDEW) with simple password management - CSL0
Language :
Multilingual - English, French, German, Spanish
Software Version :
K1
Software Configuration :
Default
Communications Options :
Ch1=1300nm single-mode, Ch2=not fitted (2 Terminal only)
Channels :
Single
In :
1/5A
Frequency :
50 / 60 Hz
Case Mounting :
Flush Panel

Page 4 of 11 458034693.xls 02/03/2020


21/11/19
10/09/19
12/04/19
20/03/19
03/12/18
18/09/18
12/07/18
30/06/18
14/05/18
04/01/18
13/11/17
22/09/17
06/03/17
11/08/16
04/07/16
01/10/14
24/07/14
05/02/14
05/07/13
25/11/12
04/10/12
10/09/12
20/08/12
18/07/12
11/07/12
10/06/12
03/06/12
14/05/12
13/03/12
27/02/12
10/02/12
21/11/11
22/09/11
01/09/11
03/03/11
18/10/10
06/10/10
15/02/10
04/12/09
11/05/09
31/03/09
13/05/08
07/02/08
19/12/07
26/04/07
26/04/07
28/02/07
20/02/07
29/08/06
24/07/06
13/07/06
28/06/06
31/05/06
20/04/06
19/04/06
03/04/06
03/04/06

07/03/06
28/02/06
21/12/05
01/11/05
01/09/05

17/01/05
15/12/04
10/12/04
29/11/04
12/11/04
09/11/04
03/11/04
17/08/04
09/03/04
27/02/04
15/01/04
21/11/03
10/07/03
07/05/03
02/03/03
18/02/03
17/12/02
11/12/02
05/12/02
27/11/02
12/11/02
O2 kill reference warning added
PEP0548158R releases software version K1
Process Bus options released
Amendment to 'C0' text from incorrect 'with distance' to 'without distance'
Correction to product option text
SW 'H9' released
Product options P,8 readded as removed in error on PWP program
Hardware option B removed from offer as per PWP program
Obsolescence warning added to hardware options = B
Obsolescence actions : design suffix J, hardware options 3,4,6,A,G,H,L,M,N & P and product options D,V,P,F,X,8,J,1,K,2,M &
Software release D3 and obsolescence warnings added
Software version H7 released along with new 16 Input & 24 Output options
CZHO-AHSB9Y releases software version H6
MBRO-ACEKEZ releases software version H4 with new Ethernet comms options
XLAZ-A9Z8LL releases D2 software version
As per MBRO-9NLE2F .. Software version D1 released
As per SBIA-9KBCL4 new power supply option released (9) with (1) removed from option
As per DKEG-9FJDJW power supply voltage amended from 24-48Vdc to 24-32Vdc
SBIA-98UAW2 releases PRP options
As per SBIA-8YQCWT + SBIA-8ZUAH6 PCBA 2071960A22 replaces ZN0017012
"Stand alone non modulated IRIG-B" (digit 7 = C) withdrawn from offer as per Obsolescence Program
HMI amended from GN027700x to 2072035A0x per JGAR-8X7AQ8
Vx auxiliary rating amended to 48 - 110 Vdc (from 48-110Vdc (40-100Vac)) per CBUN-8WXJKE
Additional communications protocols added to 'B0' major S/W version as per MBRO-8TNDW4
Design suffices B & G withdrawn from offer per Obsolescence Program
S/W releases C0 & D0 as MBRO-8V7BMX
2071962A01 replaces ZN0019001 and 2071966A01 replaces ZN0031001 as per SBIA-8URHXU
Obsolescence warning added to suffix B & G options
PSUs amended to 2071964xxx as per SBIA-8S6A9S
Tendering sheet added
Obsolescence warning added to "Stand alone non modulated IRIG-B" (digit 7 = C) as per latest obsoletion notice
Restrictions on protocol options for 'A0' & 'B0' SW version applied as per M. Browne instruction
SW versions 'A0' and 'B0' released as per MBRO-8KTHKH
Updated as per latest AG obsoletion notice
Reworked for Schneider Electric requirements
Vn rating corrected, was 48 - 110Vdc (30 - 100Vac)
References to Alstom, Areva and MiCOM removed. 'Settings' replaced by 'Customisation'
47' & '57' software released by CID SSWA-7ZMJNR
Redundant Ethernet options made available, see CIDs NROB-7YAKCC & SKEL-7YBM34
Cortec corrected (softwares 4* & 5*, descriptions were reversed in error)
Vx rating changed in line with CID BLIN-7P7HJX; '45'/'55' software released - see CID NROB-7QGBSS
54' & '44' Software released - protocol DNP 3.0 over Ethernet now available, See CID NROB-7DPAJC
Software version '12' conditionally re-added to Cortec with agreement from N Robinson
Software versions '11' & '12' removed from Cortec - see CID NROB-7A2BF6
Database correction to allow Modbus with Hardwares B, G & J with Options 2, 3, 4, 7 & 8
NROB-74SGQU - full release of '42' & '52' software including Chinese language variant, protocols clarified for hardware option
BOM modified in line with SWOO-6XHG6N making the user interface a model list variable
"42" & "52" Software released for IEC61850 options only: see CID NROB-6YFBQD
"New" Cortec & Date Drivers corrected to show Product Specific option "4" as "Ch1=1300nm multi-mode …" rather than "… si
"16" Software released for Design Suffix "B" and Protocol "3" : CID NROB-6RZCWS
Database corrected with latest text options throughout.
Database & Date Drivers include IEC 61850 with 41/51 Softwares & High Break. Documents now include two digit key for Cus
Wattage info. Removed from Master Text (by hiding row) per CDN R6034
Versions "Z" to "AC" corrected to control Hardware Options with Hardware Version "B" for Protocols 1,2,3 & 4
Version"AB" corrected to show all Hardware Options with Hardware Versions "B & G" for Protocols 1,2,3 & 4
Release of some "K" Hardware with "40" or "50" Softwares with DC dates =>05/05/06. CDN R5946
Version"AA" corrected to remove "IRIG-B (De-modulated) from available options until further notice

Hardware Suffix "K" & Software Series "50" with Distance or "40" without Distance, IEC61850 options denoted "AVAILABLE S
Date Drivers & "New" Cortec text was "… IEC61850 + IEC61850 via rear RS485 port …" & IEC61850 S/Ware requirement det
BOM dependencies corrected for ZN0031s & ZN0042s (were based on digits 9&15) in error
Hardware Suffix "K" & Software Series "50" with Distance or "40" without Distance, IEC61850 & revised Ethernet options adde
On BOM GN0107020 was driven by 'N', (see above)
Hardware options amended to read "Second Rear Comms" & "IRIG-B & Second Rear Comms", also text changes to product s
…, 1550nm single-mode + 850nm multi-mode option amended to R - was showing N in error
"30…J" released to production with DC date of 15/12/04 as per agreement between A Macfarlane, Neil Robinson, Patricia Hor
Product Specific options "L", "M" & "N" added, applicable only to suffix "G" and suffix "J" relays as per CDN R5307
BOM corrected (GN0010 duplicated in error under Drg Ref 5)
"30…J" released to production with DC date of 07/01/05 as per CDN R5272
Product Specific options "H", "J" & "K" added, applicable only to suffix "G" and suffix "J" relays as per CDN R5189
"30…J" Software/Hardware added with DC date of 01/01/05
Configurator amended to allow choice of design suffix and software first to drive the subsequent options, software/hardware 13
"20…G" Software/Hardware release date re-set set for 09/03/04. CDN R3500/176
Rack mounting option removed from Cortec worksheet (never was selectable)
"20…G" Software/Hardware release date re-set set for 19/06/04
"20…G" Software/Hardware release date with "…/Russian" language option set for 19/01/04
Russian language was incorrectly available from 01/03/03
ZB9800801 & ZB9800802 added to BOM for use when Ethernet is selected
Software & Design Suffix back to 12 and B, 20 & G were released to enable special orders and will be re-released when fully a
P541 cortec created from P54x, includes UCA2 / Ethernet from 01/03/2003
P547 software issue to "03", was "02"
Case Assy's added to bom for P545 & P546
Bom amended as there were repeat parts,Date drivers added for Hardware and Protocol, New final assembly drawings added
Rear Comms added to P541-546, software issue now 12 was 11
Original Created
BOM

Qty.
NUMBER DESCRIPTION Ref
Required
P543911B3M0K18M
GN0361001 F/ASSY:CURR.DIFF 3 1
2072035A01 F/ASSY USER INTERFACE (60TE) EXTENDED PHII Ref 22 1
2071964A05 PSU 24/32V Ref 1 1
2071966A01 PCB ASSY MVP PHASE 2 RELAY-A/04 Ref 2 2
2071960A22 OPTO INPUT BOARD Ref 3 1
GN0107010 CURRENT DIFF. MODULE Ref 5 1
GN0010072 INPUT-Current Diff 1&2/ Phase-Comparison Ref 23 1
GN2037001 BLANKING PLATE. Ref 34 1
ZB4018110 Self tapping screw pan head size 4 X ¼" Ref 60 6
ZB4018215 SELF TAP SCREW SIZE 6x1/4" LG (KAN) Ref 61 2

Page 9 of 11 458034693.xls 02/03/2020


1 2 3 4 5 6 7 8 9 10 11 12 13

Cortec Landing cell : P54391KB7M0C08M P 5 4 3 9 1 K B 7 M 0 C 0


Configurator feedback : P543911B3M0K18M P 5 4 3 9 1 1 B 3 M 0 K 1
0
Cortec digit control 1 P
Cortec digit control 2 5
Cortec digit control 3 4
Cortec digit control 4 3
$B$1 1 9
$B$31 1 1
$B$13 1 1
$B$35 1 B
$B$39 2
$B$6 2 3
$B$76 M
$B$60 1 0
$B$85 1 K 1
$B$72 1
$B$80 1
14 15

8 M
8 M double digit in same row

5
6
7
8
9
10
11
12
13
14
15 1
16
17
8 18
M 19
0
0
0
0
0
0
0
0
0
0
0
0

Das könnte Ihnen auch gefallen