Reference No.

: WT12128113-D-F-L Page 2 of 97

Test item description .................... : INSTANTANEOUS WATER HEATER


Trademark ....................................... : --
Model and/or type reference ........... : KUL59-813/85, KUL59-813/80, KUL59-813/75, KUL59-813/66,
KUL59-812/85, KUL59-812/80, KUL59-812/75, KUL59-812/66
Rating(s) ........................................... : 220-240V~, 50/60Hz, Class I, IPX4
8500W for KUL59-813/85 and KUL59-812/85, 8000W for
KUL59-813/80 and KUL59-812/80, 7500W for KUL59-813/75 and
KUL59-812/75, 6600W for KUL59-813/66 and KUL59-812/66
Copy of marking plate:

Marking plates for other models are same as model KUL59-813/80 except model name and rated power.

Summary of testing:

1. The samples are tested and found to be complied with the requirements of standards listed on cover
page.
2. Full tests were performed on model KUL59-813/85.

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 3 of 97

Test item particulars .................................................. :


Classification of installation and use ............................ : Fixed appliance and household indoor use only
Supply Connection........................................................ : Permanent connected to fixed wiring
...................................................................................... :
...................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object .................. : N
- test object does meet the requirement ....................... : P (Pass)
- test object does not meet the requirement ................. : F (Fail)

General remarks:

"(See Enclosure #)" refers to additional information appended to the report.


"(See appended table)" refers to a table appended to the report.
Throughout this report a point is used as the decimal separator.

General product information:

1. The appliance is for household and indoor use only.


2. Models are the same and have same construction and circuit principle diagram except rated power of
heating element.

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 4 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

5 GENERAL CONDITIONS FOR THE TESTS —


Tests performed according to clause 5, e.g. nature of P
supply, sequence of testing, etc
5.3 When tests carried out on single appliance, tests of P
clause 22.102, 22.107, 22.108 and 24.102 carried out
before tests of 19 (IEC 60335-2-35)
5.7 Water having temperature of 15 °C ± 5 °C used for P
tests (IEC 60335-2-35)

6 CLASSIFICATION —
6.1 Protection against electric shock (IEC 60335-2-35): —
- Bare-element water heaters class I or III N
(IEC 60335-2-35)
- Other water heaters class I, II or III (IEC 60335-2-35) Class I P
6.2 Water heaters be at least IPX1 (IEC 60335-2-35) IPX4 P

7 MARKING AND INSTRUCTIONS —


7.1 Rated voltage or voltage range (V) ............................ : 220-240V P
Nature of supply.......................................................... : ~ P
Rated frequency (Hz) ................................................. : 50/60Hz P
Rated power input (W) ............................................... : See page 2 P
Rated current (A) ....................................................... : N
Manufacturer's or responsible vendor's name, See page 2 P
trademark or identification mark................................. :
Model or type reference.............................................. : See page 2 P
Symbol 5172 of IEC 60417, for class II appliances N
IP number, other than IPX0........................................ : IPX4 P
Appliances marked with rated pressure in pascals See page 2 P
(MPa) (IEC 60335-2-35) ............................................. :
Bare-element water heaters marked with substance N
of the following:
The water resistivity must not be less than ... /cm
(IEC 60335-2-35)
Symbol IEC 60417-5036, for enclosure of N
electrically-operated water valves in external
hose-sets for connection of appliance to water mains
(IEC 60335-1/A1)
7.2 Warning for stationary appliances for multiple supply N
Warning placed in vicinity of terminal cover N

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 5 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

7.3 Range of rated values marked with the lower and P


upper limits separated by a hyphen
Different rated values marked with the values P
separated by an oblique stroke
7.4 Appliances adjustable for different rated voltages, the N
voltage setting is clearly discernible
7.5 Appliances with more than one rated voltage or one or N
more rated voltage ranges, marked with rated input or
rated current for each rated voltage or range, unless
power input is related to the arithmetic mean value of P
the rated voltage range (IEC 60335-1/A2)
Relation between marking for upper and lower limits N
of rated power input or rated current and voltage is
clear
7.6 Correct symbols used (IEC 60335-1/A1, P
IEC 60335-1/A2)
7.7 Connection diagram fixed to appliances to be N
connected to more than two supply conductors and
appliances for multiple supply
7.8 Except for type Z attachment, terminals for connection to the supply mains indicated as —
follows:
- marking of terminals exclusively for the neutral N
conductor (N)
- marking of protective earthing terminals P
(symbol 5019 of IEC 60417)
- marking not placed on removable parts P
7.9 Marking or placing of switches which may cause a P
hazard
7.10 Indications of switches on stationary appliances and By letters and other visual P
controls on all appliances by use of figures, letters or means
other visual means ..................................................... :
Figure 0 indicates only OFF position, unless N
no confusion with the OFF position N
7.11 Indication for direction of adjustment of controls P
7.12 Instructions for safe use provided P
If necessary to take precautions during user P
maintenance details be given
Instructions for open-outlet water heaters used with P
spray head state that spray head must be descaled
regularly (IEC 60335-2-35)
Instructions include substance of following (IEC 60335-2-35): —

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 6 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

WARNING: Do not switch on if there is a possibility N


that the water in the heater is frozen.
(IEC 60335-2-35)
Instructions state that (IEC 60335-1/A2): —
- Appliance is not to be used by children or persons P
with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge,
unless they have been given supervision or
instruction (IEC 60335-1/A2)
- Children being supervised not to play with appliance P
(IEC 60335-1/A2)
7.12.1 Sufficient details for installation supplied P
The installation instructions for open-outlet water P
heaters shall state that the outlet must not be
connected to any tap or fitting other than those
specified.
(IEC 60335-2-35)
If a pressure relief device is required for closed water N
heaters, the instructions shall state that it must be
fitted during Installation, unless it is incorporated in the
appliance.
(IEC 60335-2-35)
Installation instructions for bare-element water heaters state substance of following —
(IEC 60335-2-35):
- the resitivity of the water supply must not be less N
than ... Ωcm (IEC 60335-2-35)
- the appliance must be permanently connected to N
fixed wiring (not necessary if it complies with the
requirements for the connection by a supply cord
fitted with a plug specified in 13.2 and 24.101)
(IEC/EN 60335 2 35/A1)
- the appliance must be earthed (for class I appliances N
only) (IEC 60335-2-35)
When bare-element water heaters cannot be N
emptied, installation instruction state that appliance is
not to be installed in locations where freezing can
occur (IEC 60335-2-35)
7.12.2 Stationary appliances not fitted with means for P
disconnection from the supply mains having a contact
separation in all poles that provide full disconnection
under overvoltage category III, instructions state that
means for disconnection incorporated in fixed wiring
in accordance with wiring rules
7.12.3 Insulation of fixed wiring in contact with parts N
exceeding 50 K during clause 11; instructions stating
that fixed wiring protected
7.12.4 Instructions for built-in appliances: —

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 7 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

- dimensions of space N
- dimensions and position of supporting means N
- distances between parts and surrounding structure N
- dimensions of ventilation openings and arrangement N
- connection to supply mains and interconnection of N
separate components
- disconnection the appliance after installation, by N
accessible plug or a switch in fixed wiring in
accordance with wiring rules, unless
(IEC 60335-1/A1)
switch complying with clause 24.3 (IEC 60335-1/A1) N
7.12.5 Replacement cord instructions, type X attachment N
with a specially prepared cord
Replacement cord instructions, type Y attachment P

Replacement cord instructions, type Z attachment N

7.12.6 Caution in instructions for heating appliances with N


non-self-resetting thermal cut-out (IEC 60335-1/A1)
7.12.7 Instructions for fixed appliances state how appliance P
fixed to its support (IEC 60335-1/A1)
7.12.8 Instructions for appliances connected to water mains state (IEC 60335-1/A1): —
- maximum inlet water pressure (Pa) P
(IEC 60335-1/A1) ..................................................... :
- minimum inlet water pressure (Pa) if this is N
necessary (IEC 60335-1/A1) .................................... :
Instructions for appliances connected to water mains by detachable hose-sets state —
(IEC 60335-1/A1):
- new hose-sets supplied with appliance are to be P
used (IEC 60335-1/A1)
- old hose-sets not be used (IEC 60335-1/A1) P
7.13 Instructions and other texts in an official language In English P
7.14 Marking clearly legible and durable P
7.15 Marking on a main part P
Marking clearly discernible from outside, if necessary P
after removal of a cover
Portable appliances, cover can be removed or opened N
without a tool
Stationary appliances, name, trademark or P
identification mark and model or type reference visible
after installation
Fixed appliances, name, trademark or identification P
mark and model or type reference visible after
installation according to instructions
Waltek Services (Shenzhen) Co., Ltd.
http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 8 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Indications for switches and controls placed on or P


near components
Marking not on parts which can be positioned or P
repositioned in such a way that marking is misleading
Additional markings for bare-element water heaters N
visible during installation of appliance
(IEC 60335-2-35)
7.16 Marking of a possible replaceable thermal link or N
fuse link clearly visible with regard to replacing the link
7.101 Water inlet and water outlet be identified P
(IEC 60335-2-35)
Identification not on detachable parts P
(IEC 60335-2-35)
If colours used, blue for inlet and red for outlet P
(IEC 60335-2-35)
7.102 Class I bare-element water heaters marked to state N
that appliance must be earthed (EN 60335-2-35)

8 PROTECTION AGAINST ACCESS TO LIVE PARTS —


8.1 Adequate protection against accidental contact with P
live parts
8.1.1 Requirement applies for all positions, detachable P
parts removed
Insertion or removal of lamps, protection against N
contact with live parts of the lamp cap
Use of test probe B of IEC 61032: no contact with live P
parts
8.1.2 Use of test probe 13 of IEC 61032 through openings P
in class 0 appliances and class II appliances and
constructions: no contact with live parts
Test probe 13 also applied through openings in P
earthed metal enclosures having a non-conductive
coating: no contact with live parts
8.1.3 For appliances other than class II, use of test N
probe 41 of IEC 61032: no contact with live parts of
visible glowing heating elements
8.1.4 Accessible part not considered live if: —
- safety extra-low a.c. voltage: peak value not N
exceeding 42,4 V
- safety extra-low d.c. voltage: not exceeding 42,4 V N

- or separated from live parts by protective impedance N

If protective impedance: d.c. current not exceeding N


2 mA, and

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 9 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

a.c. peak value not exceeding 0,7 mA N

- for peak values over 42,4 V up to and including N


450 V, capacitance not exceeding 0,1 µF
- for peak values over 450 V up to and including N
15 kV, discharge not exceeding 45 µC
- for peak values over 15 kV energy of discharge not N
exceed 350 mJ (IEC 60335-1/A2)
8.1.5 Live parts protected at least by basic insulation before installation or assembly: —
- built-in appliances N
- fixed appliances P
- appliances delivered in separate units N
Requirement not apply to wall-mounted appliances N
intended to be permanently connected to fixed wiring
by cables having nominal cross-sectional more than
2,5 mm² (IEC 60335-2-35)
However, cross-sectional area of cable entry not N
exceed 25 cm² and there be no accessible live parts
within projection of opening (IEC 60335-2-35)
8.2 Class II appliances and constructions constructed so P
that there is adequate protection against accidental
contact with basic insulation and metal parts
separated from live parts by basic insulation only
Only possible to touch parts separated from live parts P
by double or reinforced insulation

10 POWER INPUT AND CURRENT —


10.1 Power input at normal operating temperature, rated (See appended table) P
voltage and normal operation not deviating from rated
power input by more than shown in table 1
Deviation of appliance with one or more rated voltage N
ranges (IEC 60335-1/A2)
10.2 Current at normal operating temperature, rated N
voltage and normal operation not deviating from rated
current by more than shown in table 2
Deviation of appliance with one or more rated voltage N
ranges (IEC 60335-1/A2)

11 HEATING —
11.1 No excessive temperatures in normal use P
11.2 Placing and mounting of appliance as described P
11.3 Temperature rises, other than of windings, P
determined by thermocouples

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 10 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Temperature rises of windings determined by P


resistance method, unless
windings makes it difficult to make necessary N
connections
11.4 Heating appliances and heating elements operated (See appended table) P
under normal operation at 1,15 times rated power
input (W) ..................................................................... :
11.5 Motor-operated appliances operated under normal N
operation at most unfavourable voltage between 0,94
and 1,06 times rated voltage (V) ................................ :
11.6 Combined appliances operated under normal N
operation at most unfavourable voltage between 0,94
and 1,06 times rated voltage
11.7 Appliance operated until steady conditions P
established (IEC 60335-2-35)
11.8 Temperature rises not exceeding values in table 3 (See appended table) P
(IEC 60335-1/A2)
Protective devices do not operate, except P
components in protective electronic circuits tested for N
the number of cycles specified in clause 24.1.4
(IEC 60335-1/A1)
Sealing compound does not flow out P

13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING —


TEMPERATURE
13.1 Leakage current not excessive and electric strength P
adequate
Heating appliances operated at 1,15 times rated (See appended table) P
power input (W) .......................................................... :
Motor-operated appliances and combined appliances N
supplied at 1,06 times rated voltage (V) .................... :
Protective impedance and radio interference filters N
disconnected before carrying out the tests
13.2 Leakage current measured by means of the circuit P
described in figure 4 of IEC 60990
Bare-element water heaters tested with water having N
resistivity marked on appliance (IEC 60335-2-35)
Class I bare-element water heaters, leakage current N
measured between metal sieve positioned in water
10 mm from orifice of outlet, and earthing terminal
(IEC 60335-2-35)

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 11 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Single-phase appliances, terminals of heating N


element connected through selector switch to each
pole of supply in turn, as shown in figure 101
(IEC 60335-2-35)
Three-phase appliances, earthing terminal connected N
to neutral conductor, as shown in figure 102
(IEC 60335-2-35)
Leakage current not exceed 0,25 mA N
(IEC 60335-2-35)
Bare-element water heaters intended to be connected N
to power supply by supply cord fitted with plug,
leakage current test repeated.
Leakage current measured between earthing terminal
of appliance and neutral conductor, as shown in
figure 103. Leakage current, measured with selector
switch in each position, not exceed 2,75 mA
(IEC 60335-2-35/A1)
Leakage current measurements (See appended table) P
13.3 Appliance is disconnected from supply P
(IEC 60335-1/A1)
Electric strength tests according to table 4 (See appended table) P
(IEC 60335-1/A1)
No breakdown during tests (IEC 60335-1/A1) P

14 TRANSIENT OVERVOLTAGES —
Appliances withstand the transient overvoltages to N
which they may be subjected
Clearances having a value less than specified in N
table 16 subjected to an impulse voltage test, test
voltage specified in table 6 (IEC 60335-1/A1)
No flashover during test, unless of functional N
insulation
In case of flashover of functional insulation, appliance N
complies with clause 19 with clearance short-circuited

15 MOISTURE RESISTANCE —
15.1 Enclosure provides the degree of moisture protection P
according to classification of appliance
Compliance checked as specified in clause 15.1.1, P
taking into account 15.1.2, followed by the electric
strength test of 16.3
No trace of water on insulation which can result in a P
reduction of clearances and creepage distances
below values specified in clause 29

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 12 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

15.1.1 Appliances, other than IPX0, subjected to tests as IPX4 P


specified in IEC 60529................................................ :
Water valves containing in external hoses for N
connection of an appliance to water mains, subjected
to the test as specified for IPX7 appliances
(IEC 60335-1/A1)
15.1.2 Hand-held appliance turned continuously through N
most unfavourable positions during test
Built-in appliances installed according instructions N
Appliances placed or used on the floor or table placed N
on a horizontal unperforated support
Appliances normally fixed to a wall and appliances P
with pins for insertion into socket-outlets are mounted
on a wooden board
For IPX3 appliances, the base of wall mounted N
appliances is placed at the same level as the pivot
axis of the oscillating tube
For IPX4 appliances, horizontal centre line of P
appliance is aligned with pivot axis of oscillating tube
However, for appliances normally used on floor or P
table, movement is limited to two times 90  for a
period of 5 min, support being placed at the level of
pivot axis of oscillating tube
Wall-mounted appliances fixed at distance of 3 mm P
from mounting surface, unless (IEC 60335-2-35)
installation instructions specify larger value N
(IEC 60335-2-35)
Appliances normally fixed to a ceiling are mounted N
underneath a horizontal unperforated support, pivot
axis of oscillating tube located at level of underside of
support (IEC 60335-1/A1)
IPX4 appliances, movement of tube is limited to two P
times 90  from vertical for a period of 5 min
(IEC 60335-1/A1)
Wall-mounted appliances, take into account distance P
to floor stated in instructions
Appliances with type X attachment fitted with a flexible N
cord as described
Detachable parts tested as specified P
15.2 Spillage of liquid does not affect the electrical N
insulation
Appliances with type X attachment fitted with a flexible N
cord as described

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 13 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Appliances incorporating an appliance inlet tested with N


or without an connector, whichever is most
unfavourable
Detachable parts removed N

Overfilling test with additional amount of water, over a N


period of 1 min (l)........................................................ :
Appliance withstands the electric strength test of N
clause 16.3
No trace of water on insulation that can result in a N
reduction of clearances and creepage distances
below values specified in clause 29
15.3 Appliances proof against humid conditions P
Humidity test for 48 h in a humidity cabinet 25℃, 93% R.H P
Appliance withstands tests of clause 16 P

16 LEAKAGE CURRENT AND ELECTRIC STRENGTH —


16.1 Leakage current not excessive and electric strength P
adequate
Protective impedance disconnected from live parts N
before carrying out tests
16.2 Single-phase appliances: test voltage 1,06 times rated (See appended table) P
voltage (V)................................................................... :
Three-phase appliances: test voltage 1,06 times rated N
voltage divided by 3 (V) ............................................ :
Bare-element water heaters tested with water having N
resistivity marked on appliance (IEC 60335-2-35)
Leakage current measurements (See appended table) P
16.3 Electric strength tests according to table 7 (See appended table) P
(IEC 60335-1/A1)
No breakdown during tests P

17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS —


No excessive temperatures in transformer or P
associated circuits in event of short-circuits likely to
occur in normal use
Appliance supplied with 1,06 or 0,94 times rated (See appended table) P
voltage and most unfavourable short-circuit or
overload likely to occur in normal use applied (V) ..... :
Temperature rise of insulation of the conductors of N
safety extra-low voltage circuits not exceeding the
relevant value specified in table 3 by more than 15 K
(K) ............................................................................... :

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 14 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Temperature of winding not exceeding value specified P


in table 8,
however limits do not apply to fail-safe transformers N
complying with sub-clause 15.5 of IEC 61558-1

19 ABNORMAL OPERATION —
19.1 Risk of fire or mechanical damage under abnormal or P
careless operation obviated
Electronic circuits so designed and applied that a fault P
will not render appliance unsafe
Appliances incorporating contactors or relays P
subjected to test of clause 19.14, being carried out
before tests of 19.11 (IEC 60335-1/A2)
19.4 Test conditions as in clause 11, any control limiting For the appliances, no controls P
the temperature during tests of 11 short-circuited limiting the temperature during
clause 11
Open-outlet water heaters, flow switches and (See appended table) P
pressure switches that operate during test of
clause 11 short--circuited, water-control valve
adjusted to most unfavourable position
(IEC 60335-2-35)
Flow switches of closed water heaters short-circuited N
and any pressure relief device rendered inoperative,
outlet valve closed (IEC 60335-2-35)
However, if appliance has no flow switch and N
back-siphonage is likely to occur, water heater filled
with just sufficient water to cover heating element and
operated with outlet valve open (IEC 60335-2-35)
19.5 Test is not carried out on appliances intended to be P
permanently connected to fixed wiring or
on appliances where an all-pole disconnection occurs N
during test of clause 19.4
Test of clause 19.4 repeated on class 0I and I N
appliances with tubular sheathed or embedded
heating elements. No short-circuiting, but one end of
element connected to elements sheath
Test repeated with reversed polarity and other end of N
heating element connected to sheath
19.6 Appliances with PTC heating elements tested at rated N
voltage, establishing steady conditions
The working voltage of the PTC heating element is N
increased by 5 % and the appliance is operated until
steady conditions are re-established. Voltage is then
increased in similar steps until 1,5 times working
voltage or until the PTC heating element ruptures (V):

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 15 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

19.7 Stalling test by locking rotor if locked rotor torque is N


smaller than full load torque or locking moving parts of
other appliances
Locked rotor, motor capacitors open-circuited or N
short-circuited, if required
Locked rotor, capacitors open-circuited one at a time N
Test repeated with capacitors short-circuited one at a N
time, if required
Appliances with timer or programmer supplied with N
rated voltage for each of tests, for a period equal to
maximum period allowed
Other appliances supplied with rated voltage for a N
period as specified
Winding temperatures not exceeding values specified N
in table 8
19.8 Three-phase motors operated at rated voltage with N
one phase disconnected
19.9 Running overload test on appliances incorporating N
motors intended to be remotely or automatically
controlled or liable to be operated continuously
Winding temperatures not exceeding values as N
specified
19.10 Series motor operated at 1,3 times rated voltage for N
1 min ........................................................................... :
During test, parts not being ejected from appliance N
19.11 Electronic circuits, compliance checked by evaluation P
of the fault conditions in clause 19.11.2 for all circuits
or parts of circuits, unless they comply with conditions
in 19.11.1
Appliances incorporating protective electronic circuit N
subjected to tests of clause 19.11.3 and 19.11.4
(IEC 60335-1/A1)
Appliances incorporating an electronic circuit that P
relies upon a programmable component to function
correctly, subjected to test of clause 19.11.4.8
(IEC 60335-1/A2)
Appliances having a device with an off position P
obtained by electronic disconnection, or a device
placing the appliance in a stand-by mode, subjected to
tests of clause 19.11.4 (IEC 60335-1/A2)
During and after each test following is checked: —
- temperature rise of windings do not exceed values N
specified in table 8, however
these limits do not apply to fail-safe transformers N
complying with sub-clause 15.5 of IEC 61558-1

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 16 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

- appliance complies with conditions specified in P


clause 19.13
- any current flowing through protective impedance N
not exceeding limits specified in clause 8.1.4
If a conductor of a printed board becomes open-circuited, appliance considered to —
withstood particular test, provided both following conditions are met (IEC 60335-1/A2):
- base material of printed circuit board withstands test P
of annex E
- any loosened conductor not reduce clearances or P
creepage distances between live parts and
accessible metal parts below values specified in
clause 29 (IEC 60335-1/A2)
19.11.1 Fault conditions a) to f) in 19.11.2 not applied to circuits or parts of circuit when both —
following conditions are meet:
- electronic circuit is a low-power circuit, that is, N
maximum power at low-power points not exceed
15 W according tests specified
- protection against electric shock, fire hazard, P
mechanical hazard or dangerous malfunction in
other parts of the appliance does not rely on correct
functioning of electronic circuit
19.11.2 Fault conditions applied one at a time, appliance operated under conditions specified in —
clause 11, but supplied at rated voltage, duration of tests as specified
(IEC 60335-1/A1):
a) short-circuit of functional insulation if clearances or P
creepage distances are less than values specified
in clause 29
b) open-circuit at terminals of any component P
c) short-circuit of capacitors, unless they comply with P
IEC 60384-14
d) short-circuit of any two terminals of an electronic P
component, other than integrated circuits. This fault
condition is not applied between two circuits of an
optocoupler
e) failure of triacs in diode mode P
f) failure of an integrated circuit (IEC 60335-1/A1) P
g) failure of an electronic power switching device N
(IEC 60335-1/A2)
Each low-power circuit is short-circuited N
In each case, test is ended if a non-self-resetting P
interruption of supply occurs within appliance
(IEC 60335-1/A1)

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 17 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

19.11.3 If appliance incorporates a protective electronic circuit N


which operates to ensure compliance with clause 19,
relevant test is repeated with a single fault simulated,
as indicated in a) to f) of 19.11.2
19.11.4 Appliance having a device with an off position N
obtained by electronic disconnection, or
(IEC 60335-1/A2)
device that can be placed in stand-by mode, N
(IEC 60335-1/A2)
subjected to tests of clause 19.11.4.1 to 19.11.4.7. N
Device set in off position or stand-by mode
(IEC 60335-1/A2)
Appliance incorporating a protective electronic circuit N
subjected to tests of clause 19.11.4.1 to 19.11.4.7,
except that (IEC 60335-1/A2)
appliance operated for 30 s or 5 min during test of N
clause 19.7 not subjected to tests for electromagnetic
phenomena (IEC 60335-1/A1)
19.11.4.1 Appliance subjected to electrostatic discharges in N
accordance with IEC 61000-4-2, test level 4
(IEC 60335-1/A1)
19.11.4.2 Appliance subjected to radiated fields in accordance N
with IEC 61000-4-3, test level 3 (IEC 60335-1/A1)
19.11.4.3 Appliance subjected to fast transient bursts in N
accordance with IEC 61000-4-4, test level 3 or 4 as
specified (IEC 60335-1/A1)
19.11.4.4 Power supply terminals of appliance subjected to N
voltage surges in accordance with IEC 61000-4-5,
test level 3 or 4 as specified (IEC 60335-1/A1)
Earthed heating elements in class I appliances N
disconnected (IEC 60335-1/A1)
Appliance having surge arresters incorporating spark N
gaps, test is repeated at level that is 95 % of flashover
voltage (IEC 60335-1/A1)
19.11.4.5 Appliance subjected to injected currents in N
accordance with IEC 61000-4-6, test level 3
(IEC 60335-1/A1)
19.11.4.6 Appliance subjected to class 3 voltage dips and N
interruptions in accordance with specified values in
table 1 and 2 of IEC 61000-4-11 (IEC 60335-1/A2)
19.11.4.7 Appliance subjected to mains signals in accordance N
with IEC 61000-4-13, test level class 2
(IEC 60335-1/A1)

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 18 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

19.11.4.8 Appliance supplied at rated voltage and operated P


under normal operation. After 60 s power supply is
reduces to a level such that appliance ceases to
respond or a programmable component ceases to
operate (IEC 60335-1/A2)
Appliance continue to either operate normally from the N
same point which the voltage decrease occurred or
(IEC 60335-1/A2)
manual operation required to restart P
(IEC 60335-1/A2)
19.12 If safety of appliance for any fault conditions specified N
in clause 19.11.2 depends on operation of a miniature
fuse-link complying with IEC 60127, test is repeated,
measuring current flowing through the fuse-link;
measured current (A); rated current of fuse-link (A) .. :
19.13 During tests appliance does not emit flames, molten P
metal, poisonous or ignitable gas in hazardous
amounts
Temperature rises not exceeding values shown in (See appended table) P
table 9
During test of clause 19.4, container not rupture and P
(IEC 60335-2-35)
water temperature not exceed (IEC 60335-2-35) —
- 140 °C, for closed water heaters with capacity N
exceeding 1 l (IEC 60335-2-35)
- 99 °C, for open-outlet water heaters with capacity P
exceeding 1 l (IEC 60335-2-35)
Enclosures not deformed to such an extent that P
compliance with clause 8 is impaired
(IEC 60335-1/A2)
If appliance can still be operated it complies with P
clause 20.2 (IEC 60335-1/A2)
Insulation, other than of class III appliance, withstand electric strength test of —
clause 16.3, test voltage specified in table 4:
- basic insulation ......................................................... : 1000V P
- supplementary insulation.......................................... : 1750V P
- reinforced insulation ................................................. : 3000V P
After operation or interruption of a control, clearances P
and creepage distances across functional insulation
withstanding electric strength test of clause 16.3. Test
voltage being twice working voltage (IEC 60335-1/A2)
Appliance does not undergo a dangerous malfunction, P
and (IEC 60335-1/A1)
no failure of protective electronic circuits, if appliance N
is still operable (IEC 60335-1/A1)

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 19 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Appliance tested with an electronic switch in off position, or in stand-by mode and —
(IEC 60335-1/A2)
- do not become operational, or (IEC 60335-1/A2) N
- if they become operational, do not result in a N
dangerous malfunction during or after tests of
clause 19.11.4 (IEC 60335-1/A2)
19.14 Appliances operated under conditions of clause 11. No relays contacts operating P
Contactors or relays contacts operating under under conditions of 11.
conditions of 11 short-circuited (IEC 60335-1/A2)

20 STABILITY AND MECHANICAL HAZARDS —


20.1 Adequate stability N
Tilting test through an angle of 10 ° (appliance placed N
on an inclined plane/horizontal plane); appliance does
not overturn
Tilting test repeated on appliances with heating N
elements, angle of inclination increased to 15 °
Possible heating test in overturned position; N
temperature rise does not exceed values shown in
table 9
20.2 Moving parts adequately arranged or enclosed as to N
provide protection against personal injury
Protective enclosures, guards and similar parts are N
non-detachable
Adequate mechanical strength and fixing of protective N
enclosures
Self-resetting thermal cut-outs and overcurrent N
protective devices not causing a hazard, by
unexpected reclosure
Not possible to touch dangerous moving parts with N
test probe

21 MECHANICAL STRENGTH —
21.1 Appliance has adequate mechanical strength and is P
constructed as to withstand rough handling
(IEC 60335-1/A1)
Checked by applying blows to the appliance in P
accordance with test Ehb of IEC 60068-2-75, spring
hammer test, impact energy 0,5 J (IEC 60335-1/A1)
If necessary, supplementary or reinforced insulation N
subjected to electric strength test of clause 16.3
(IEC 60335-1/A1)
If necessary, repetition of groups of three blows on a N
new sample (IEC 60335-1/A1)

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 20 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

21.2 Accessible parts of solid insulation having strength to P


prevent penetration by sharp implements
(IEC 60335-1/A1)
Insulation is tested as specified, unless N
(IEC 60335-1/A1)
thickness of supplementary insulation is at least 1 mm P
and reinforced insulation is at least 2 mm
(IEC 60335-1/A1)

22 CONSTRUCTION —
22.1 Appliance marked with the first numeral of the IP N
system, relevant requirements of IEC 60529 fulfilled
22.2 Stationary appliance: means to provide all-pole disconnection from supply provided, the —
following means being available:
- a supply cord fitted with a plug N
- a switch complying with clause 24.3 N
- a statement in the instruction sheet that a P
disconnection incorporated in fixed wiring is to be
provided
- an appliance inlet N
Singe-pole switches and single-pole protective N
devices for disconnection of heating elements in
single-phase, permanently connected class 0I and I
appliances, connected to phase conductor
(IEC 60335-1/A2)
22.3 Appliance provided with pins: no undue strain on N
socket-outlets
Applied torque not exceeding 0,25 Nm N
Pull force of 50 N to each pin after the appliance has N
being placed in the heating cabinet; when cooled to
room temperature the pins are not displaced by more
than 1 mm
Each pin subjected to a torque of 0,4 Nm; pins are not N
rotating unless rotating does not impair compliance
with standard
22.4 Appliance for heating liquids and appliance causing P
undue vibration not provided with pins for insertion into
socket-outlets
22.5 No risk of electric shock when touching pins of plug, No plug P
for appliances having a capacitor with rated
capacitance exceeding 0,1 F, appliance being
disconnected from supply at instant of voltage peak
(IEC 60335-1/A2)
22.6 Electrical insulation not affected by condensing water P
or leaking liquid

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 21 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Electrical insulation of class II appliances not affected P


in case of a hose rupture or seal leak
Enclosure drain hole positioned so that water can P
drain without impairing electric insulation, unless
(IEC 60335-2-35)
condensed water cannot accumulate within enclosure P
in normal use (IEC 60335-2-35)
Hole be at least 5 mm in diameter or N
(IEC 60335-2-35)
20 mm² in area with width of at least 3 mm P
(IEC 60335-2-35)
22.7 Adequate safeguards against the risk of excessive N
pressure in appliances provided with steam-producing
devices
22.8 Electrical connections not subject to pulling during P
cleaning of compartments to which access can be
gained without aid of a tool, and likely cleaned in
normal use
22.9 Insulation, internal wiring, windings, commutators and P
slip rings not exposed to oil, grease or similar
substances
Adequate insulating properties of oil or grease to N
which insulation is exposed
22.10 Not possible to reset voltage-maintained N
non-self-resetting thermal cut-outs by operation of an
automatic switching device incorporated within
appliance (IEC 60335-1/A1)
Non-self-resetting thermal motor protectors have a N
trip-free action, unless (IEC 60335-1/A1)
they are voltage maintained (IEC 60335-1/A1) N

Location or protection of reset buttons of N


non-self-resetting controls is so that accidental
resetting is unlikely
22.11 Reliable fixing of non-detachable parts that provide P
the necessary degree of protection against electric
shock, moisture or contact with moving parts
Obvious locked position of snap-in devices used for N
fixing such parts
No deterioration of the fixing properties of snap-in N
devices used in parts that are likely to be removed
during installation or servicing
Tests as described P
22.12 Handles, knobs etc. fixed in a reliable manner P

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 22 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Fixing in wrong position of handles, knobs etc. P


indicating position of switches or similar components
not possible
Axial force 15 N applied to parts, shape being so that P
an axial pull is unlikely to be applied
Axial force 30 N applied to parts, shape being so that N
an axial pull is likely to be applied
22.13 Unlikely that handles, when gripped as in normal use, P
make the operators hand touch parts having a
temperature rise exceeding the value specified for
handles which are held for short periods only
22.14 No ragged or sharp edges creating a hazard for user P
in normal use, or during user maintenance
No exposed pointed ends of self tapping screws etc., P
liable to be touched by user in normal use or during
user maintenance
22.15 Storage hooks and the like for flexible cords smooth N
and well rounded
22.16 Automatic cord reels cause no undue abrasion or N
damage to the sheath of flexible cord, no breakage of
conductors strands, no undue wear of contacts
Cord reel tested with 6000 operations, as specified N
Electric strength test of clause 16.3, voltage of 1000 V N
applied
22.17 Spacers not removable from outside by hand or by N
means of a screwdriver or a spanner
22.18 Current-carrying parts and other metal parts resistant P
to corrosion under normal conditions of use
22.19 Driving belts not used as electrical insulation N
22.20 Direct contact between live parts and thermal P
insulation effectively prevented, unless material used
is non-corrosive, non-hygroscopic and
non-combustible
Compliance is checked by inspection and, if P
necessary, by appropriate test
22.21 Wood, cotton, silk, ordinary paper and fibrous or P
hygroscopic material not used as insulation, unless
impregnated
Requirement does not apply to magnesium oxide and P
mineral ceramic fibres used for electrical insulation of
heating elements (IEC 60335-1/A2)
22.22 Appliances not containing asbestos P
22.23 Oils containing polychlorinated biphenyl (PCB) not P
used
22.24 Bare heating elements adequately supported N
Waltek Services (Shenzhen) Co., Ltd.
http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 23 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

In case of rupture, heating conductor unlikely to come N


in contact with accessible metal parts
22.25 Sagging heating conductors cannot come into contact N
with accessible metal parts
22.26 Appliances with parts of class III construction so P
constructed that insulation between parts operating at
safety extra-low voltage and other live parts complies
with double or (IEC 60335-1/A1)
reinforced insulation (IEC 60335-1/A1) P
22.27 Parts connected by protective impedance separated P
by double or reinforced insulation
22.28 Metal parts of class II appliances conductively N
connected to gas pipes or in contact with water:
separated from live parts by double or reinforced
insulation
22.29 Class II appliances permanently connected to fixed N
wiring so constructed that required degree of access
to live parts is maintained after installation
22.30 Parts serving as supplementary or reinforced P
insulation fixed so that they cannot be removed
without being seriously damaged, or
so constructed that they cannot be replaced in an P
incorrect position, and so that if they are omitted,
appliance is rendered inoperable or manifestly
incomplete
22.31 Clearances and creepage distances over P
supplementary and reinforced insulation not reduced
below values in clause 29 as a result of wear
Clearances and creepage distances between live P
parts and accessible parts not reduced below values
for supplementary insulation, if wires, screws etc.
become loose
22.32 Supplementary and reinforced insulation designed or P
protected against deposition of dirt or dust
Supplementary insulation of natural or synthetic N
rubber resistant to ageing, or arranged and
dimensioned so that creepage distances not reduced
below values in clause 29.2
Ceramic material not tightly sintered, similar material N
or beads alone not used as supplementary or
reinforced insulation
Oxygen bomb test at 70 C for 96 h and 16 h at room N
temperature
Insulating material in which heating conductors are N
embedded considered to be basic insulation and not
reinforced insulation (IEC 60335-1/A2)

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 24 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

22.33 Conductive liquids that are or may become accessible P


in normal use are not in direct contact with live parts
Electrodes not used for heating liquids N
Class II constructions, conductive liquids that are or P
may become accessible in normal use, not in direct
contact with basic or reinforced insulation
Class II constructions, conductive liquids which are in N
contact with live parts, not in direct contact with
reinforced insulation
Requirement not apply to bare-element water heaters N
(IEC 60335-2-35)
22.34 Shafts of operating knobs, handles, levers etc. not P
live, unless shaft is not accessible when part is
removed
22.35 Handles, levers and knobs, held or actuated in normal P
use, not becoming live in the event of a failure of basic
insulation (IEC 60335-1/A2)
Such parts being of metal, and their shafts or fixings N
are likely to become live in the event of a failure of
basic insulation, they are either adequately covered by
insulation material, or their accessible parts are
separated from their shafts or fixings by
supplementary insulation (IEC 60335-1/A2)
Requirement does not apply to handles, levers and N
knobs on stationary appliances other than those of
electrical components, provided they are either
reliably connected to an earthing terminal or earthing
contact, or separated from live parts by earthed metal
22.36 Handles continuously held in hand in normal use so N
constructed that when gripped as in normal use,
operators hand is not likely to touch metal parts,
unless
they are separated from live parts by double or N
reinforced insulation
22.37 Capacitors in class II appliances not connected to N
accessible metal parts, unless complying with
clause 22.42
Metal casings of capacitors in class II appliances N
separated from accessible metal parts by
supplementary insulation, unless complying with
clause 22.42
22.38 Capacitors not connected between the contacts of a P
thermal cut-out
22.39 Lamp holders used only for connection of lamps N

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 25 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

22.40 Motor-operated appliances and combined appliances N


intended to be moved while in operation, or having
accessible moving parts, fitted with a switch to control
the motor. Actuating member of switch being easily
visible and accessible
Unless appliance can operate continuously, N
automatically or remotely without giving rise to a
hazard, appliances for remote operation being fitted
with a switch. Actuating member of switch being easily
visible and accessible (IEC 60335-1/A2)
22.41 No components, other than lamps, containing P
mercury
22.42 Protective impedance consisting of at least two N
separate components
Values in clause 8.1.4 not exceeded if any one of N
components are short-circuited or open-circuited
22.43 Appliances adjustable for different voltages, N
accidental changing of setting of voltage unlikely to
occur
22.44 Appliances not have an enclosure shaped or P
decorated like a toy (IEC 60335-1/A2)
22.45 Air used as reinforced insulation, clearances not P
reduced below the values in clause 29.1.4 due to
deformation as a result of an external force applied to
enclosure
22.46 Software used in protective electronic circuits is N
software class B or C (IEC 60335-1/A1) .................... :
22.47 Appliances connected to water mains withstand water P
pressure expected in normal use (IEC 60335-1/A1)
No leakage from any part, including any inlet water P
hose (IEC 60335-1/A1)
22.48 Appliances connected to water mains constructed to P
prevent backsiphonage of non-potable water into
water mains (IEC 60335-1/A1)
22.49 Remote operation duration of operation set before N
appliance can be started, unless (IEC 60335-1/A2)
appliance switches off automatically or can operate N
continuously without hazard (IEC 60335-1/A2)
22.50 Controls incorporated in appliance take priority over N
controls actuated by remote operation
(IEC 60335-1/A2)
22.51 Control on appliance being manually adjusted to N
setting for remote operation before appliance can be
operated in this mode (IEC 60335-1/A2)
Visual indication showing that appliance is adjusted N
for remote operation (IEC 60335-1/A2)

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 26 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Manual setting and visual indication not necessary on appliances that can operate as —
follows, without giving rise to a hazard (IEC 60335-1/A2):
- operate continuously (IEC 60335-1/A2), N
- operate automatically, or (IEC 60335-1/A2) N
- be operated remotely (IEC 60335-1/A2) N
22.52 Socket-outlets on appliances accessible to user in N
accordance with socket-outlet system used in country
where appliance sold (IEC 60335-1/A2)
22.101 Rated pressure of closed water heaters be at least N
0,6 MPa (IEC 60335-2-35)
Rated pressure of closed water heaters intended to N
supplied by pressure reducing valve be at least
0,1 MPa (IEC 60335-2-35)
Rated pressure of open-outlet water heaters 0 Pa P
(IEC 60335-2-35)
22.102 Appliance withstand water pressure occurring in P
normal use (IEC 60335-2-35)
Compliance checked by subjecting appliance to water pressure of (IEC 60335-2-35): —
- twice rated pressure, for closed water heaters N
(IEC 60335-2-35)
- 0,15 MPa, for open-outlet water heaters P
(IEC 60335-2-35)
Open-outlet water heater incorporates valve that P
regulates water flow, water pressure of 2 MPa applied
to inlet of appliance, valve being closed
(IEC 60335-2-35)
Pressure relief devices rendered inoperative N
(IEC 60335-2-35)
Pressure raised at rate of 0,13 MPa/s to specified P
value and maintained for 5 min (IEC 60335-2-35)
Water not leak from appliance and (IEC 60335-2-35) P
there no permanent deformation to such an extent P
that compliance with this standard is impaired
(IEC 60335-2-35)
22.103 Closed water heaters with capacity exceeding 3 l N
supplied with pressure relief device that prevents
excessive pressure (IEC 60335-2-35)
Compliance checked by inspection and by subjecting N
appliance to slow increasing water pressure
(IEC 60335-2-35)
Pressure relief device operate before water pressure N
exceeds rated pressure by more than 0,1 MPa
(IEC 60335-2-35)

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 27 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

22.104 Outlet of open-outlet water heaters constructed so P


that water flow not limited to such an extent that
container subjected to significant pressure in normal
use (IEC 60335-2-35)
22.105 Appliances incorporating flow switch constructed so P
that if there is no water flow, heating element cannot
switched on, and switched off if water flow ceases
(IEC 60335-2-35)
22.106 Closed water heaters incorporate thermal cut-out that N
operates independently from thermostat or flow switch
(IEC 60335-2-35)
Only possible to reset thermal cut-out after removal of N
non-detachable cover (IEC 60335-2-35)
Capacity not exceed 1 l and appliance incorporates N
flow switch, an alternative protective device, such as
pressure switch, used instead of thermal cut-out
(IEC 60335-2-35)
22.107 Water not attain excessive temperature in normal use P
(IEC 60335-2-35)
Appliance operated at rated power input. Any P
regulating valve fully opened and water flow adjusted
so that flow switch or pressure switch is on verge of
operating (IEC 60335-2-35)
Temperature of outlet water (°C) not higher than 95 °C 50 °C P
and (IEC 60335-2-35) ........................................... :
not exceed temperature of inlet water (°C) by more 28.8K P
than 75 K (IEC 60335-2-35) ...................................... :
Appliances intended to supply water for showering 51 °C P
only, test carried out under normal operation and with
No thermal protector operated
water pressure of 0,2 MPa. Temperature of water at
outlet (°C) not exceed 55 °C (IEC 60335-2-35) ........ :
22.108 Outlet water of appliances intended to supply water for P
showering only not attain an excessive temperature
due to sudden pressure drop in water supply
(IEC 60335-2-35)
Appliance supplied with water at pressure of 0,4 MPa. P
It operated at rated power input with regulating valve
adjusted so that outlet water temperature is
25 K ± 1 K above inlet water temperature. Water
pressure then reduced to 0,2 MPa within 1 s
(IEC 60335-2-35)
Outlet water temperature not rise by more than 25 K P
within 10 s (IEC 60335-2-35)
Outlet water temperature measured by means of P
fine-wire thermocouple placed in centre of plastic
cylindrical receptacle having diameter of 30 mm and
height of 12 mm (IEC 60335-2-35)

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 28 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Receptacle positioned 25 mm below shower head P


(IEC 60335-2-35)
22.109 Water containers of open-outlet water heaters having No water containers N
pressure switch not rupture due to excessive internal
pressure (IEC 60335-2-35)
- appliances with weak part that ejected or ruptures N
when pressure is excessive, by the test of
clause 22.109.1 (IEC 60335-2-35);
- appliances with other means for relieving pressure, N
by tests of clause 22.109.1 and 22.109.3
(IEC 60335-2-35);
- appliances with heating elements that N
(IEC 60335-2-35):
- rupture before internal pressure is excessive, or N
(IEC 60335-2-35)
- cannot energized when internal pressure is N
excessive (IEC 60335-2-35)
by tests of clause 22.109.2 and 22.109.3 N
(IEC 60335-2-35)
After tests, appliance comply with clauses 8 and 16.2 N
(IEC 60335-2-35)
22.109.1 Appliance filled with water, water outlet being sealed. N
Water pressure then steadily increased
(IEC 60335-2-35)
Weak part ejected or rupture, or pressure relief device N
operate, before internal pressure reaches 1,1 MPa
(IEC 60335-2-35)
After pressure relieved, water allowed to flow for N
period of 1 min (IEC 60335-2-35)
22.109.2 Appliance filled with water, water outlet being sealed N
and inlet valve closed. Controls short-circuited or
open-circuited, whichever is more unfavourable
(IEC 60335-2-35)
Appliance then operated at rated power input N
(IEC 60335-2-35)
Heating element rupture without causing hazard N
unless it remains de-energized (IEC 60335-2-35)
If heating element ruptures, inlet valve opened and N
water pressure steadily increased until it reaches
1,1 MPa. Pressure maintained for 1 min
(IEC 60335-2-35)
22.109.3 Appliance filled with water, water inlet and outlet being N
sealed. Controls short-circuited or open-circuited,
whichever is more unfavourable (IEC 60335-2-35)
Appliance placed in an ambient with temperature not N
exceeding -5 °C until water frozen (IEC 60335-2-35)
Waltek Services (Shenzhen) Co., Ltd.
http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 29 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Appliance then placed in normal ambient and N


operated at rated power input (IEC 60335-2-35)
Heating element rupture without causing hazard or N
any excessive pressure be relieved by means of
pressure relief device, unless heating element
remains de-energized (IEC 60335-2-35)
Appliance switched off and allowed to reach room N
temperature (IEC 60335-2-35)
If heating element remains de-energized or ruptured, N
water supplied through inlet and pressure steadily
increased until it reaches 1,1 MPa. Pressure
maintained for 1 min (IEC 60335-2-35)
If pressure relief device operated, appliance N
connected to water supply for period of 1 min with
outlet still sealed (IEC 60335-2-35)
22.110 Appliances for wall-mounting have reliable provision P
for fixing to a wall, independent of connection to water
mains (IEC 60335-2-35)

23 INTERNAL WIRING —
23.1 Wireways smooth and free from sharp edges P
Wires protected against contact with burrs, cooling P
fins etc.
Wire holes in metal well rounded or provided with N
bushings
Wiring effectively prevented from coming into contact P
with moving parts
23.2 Beads etc. on live wires cannot change their position, N
and not resting on sharp edges or corners
Beads inside flexible metal conduits contained within N
an insulating sleeve
23.3 Electrical connections and internal conductors N
movable relatively to each other not exposed to undue
stress
Flexible metallic tubes not causing damage to N
insulation of conductors
Open-coil springs not used N
Adequate insulating lining provided inside a coiled N
spring, the turns of which touch one another
No damage after 10 000 flexings for conductors N
flexed during normal use or
100 flexings for conductors flexed during user N
maintenance

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 30 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Electric strength test, 1 000 V between live parts and N


accessible metal parts
23.4 Bare internal wiring sufficiently rigid and fixed N
23.5 Insulation of internal wiring withstanding electrical P
stress likely to occur in normal use
No breakdown when a voltage of 2 000 V is applied P
for 15 min between conductor and metal foil wrapped
around insulation
23.6 Sleeving used as supplementary insulation on internal N
wiring retained in position by positive means
23.7 Colour combination green/yellow used only for P
earthing conductors
23.8 Aluminium wires not used for internal wiring P
23.9 No lead-tin soldering of stranded conductors where P
they are subject to contact pressure, unless
clamping means so constructed that there is no risk of N
bad contact due to cold flow of solder
23.10 Insulation and sheath of internal wiring, incorporated N
in external hoses for appliance connection to water
mains, at least equivalent to that of light polyvinyl
chloride sheathed flexible cord (60227 IEC 52)
(IEC 60335-1/A1)

24 COMPONENTS —
24.1 Components comply with safety requirements in P
relevant IEC standards
List of components (See appended table) P
Components not tested and found to comply with P
relevant IEC standard for number of cycles specified,
tested in accordance with clause 24.1.1 to 24.1.9
(IEC 60335-1/A2)
Components not tested and found to comply with P
relevant IEC standard, components not marked or not
used in accordance with its marking, tested under
conditions occurring in appliance
Lampholders and starterholders not being tested and N
found to comply with relevant IEC standard, tested as
a part of appliance and additionally according to
gauging and interchangeability requirements of
relevant IEC standard (IEC 60335-1/A2)
24.1.1 Capacitors likely to be permanently subjected to N
supply voltage and used for radio interference
suppression or for voltage dividing, complying with
IEC 60384-14, or
tested according to annex F N

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 31 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

24.1.2 Safety isolating transformers complying with N


IEC 61558-2-6, or
tested according to annex G N
24.1.3 Switches complying with IEC 61058-1, the number of N
cycles of operation being at least 10 000, or
tested according to annex H N
Flow switches tested for 50000 cycles of operation tested P
(IEC 60335-2-35)
Pressure switches for open-outlet water heaters and N
pressure switches for appliances intended to supply
water for showering only tested for 20000 cycles of
operation (IEC 60335-2-35)
Pressure switches for other water heaters tested for N
50000 cycles of operation (IEC 60335-2-35)
If switch operates a relay or contactor, complete N
switching system is subjected to test
(IEC 60335-1/A1)
24.1.4 Automatic controls complying with IEC 60730-1 with relevant part 2. Number of cycles —
of operation being:
- thermostats: ....................................................10 000 N
- temperature limiters:.........................................1 000 N
- self-resetting thermal cut-outs:............................300 Approved P
- voltage-maintained non-self-resetting thermal N
cut-outs (IEC 60335-1/A1): ..............................1 000
- other non-self-resetting thermal cut-outs Approved P
(IEC 60335-1/A1): .................................................30
- timers: ...............................................................3 000 N
- energy regulators:...........................................10 000 N
Thermal cut-outs incorporated in closed water heaters N
comply with requirements for type 2B controls in
clauses 13, 15, 16, 17 and 20 of IEC 60730-1, unless
they tested with appliance (IEC 60335-2-35)
Self-resetting thermal cut-out operates during test of clause 22.107, number of cycles of —
operation increased to (IEC 60335-2-35):
- 3000, for waters heaters intended to supply water for P
showering only (IEC 60335-2-35);
- 1000, for other appliances (IEC 60335-2-35) N
Thermal motor protectors tested in combination with N
their motor under conditions specified in annex D
(IEC 60335-1/A1)

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 32 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Water valves containing live parts and incorporated in N


external hoses for appliance connection to water
mains, degree of protection declared for
subclause 6.5.2 of IEC 60730-2-8 is IPX7
(IEC 60335-1/A1)
24.1.5 Appliance couplers complying with IEC 60320-1 N
However, appliances classified higher than IPX0, N
appliance couplers complying with IEC 60320-2-3
Interconnection couplers complying with N
IEC 60320-2-2 (IEC 60335-1/A1)
24.1.6 Small lamp holders similar to E10 lampholders N
complying with IEC 60238, requirements for E10
lampholders being applicable
24.1.7 Remote operation of appliance via telecommunication N
network, relevant standard for telecommunication
interface circuitry in appliance is IEC 62151
(IEC 60335-1/A2)
24.1.8 Standard for thermal links IEC 60691 N
(IEC 60335-1/A2)
Thermal links not complying with IEC 60691 N
considered to be an intentionally weak part for
purposes of clause 19 (IEC 60335-1/A2)
24.1.9 Relays, other than motor starting relays, tested as part P
of appliance (IEC 60335-1/A2)
They also tested in accordance with clause 17 of Approved P
IEC 60730-1, number of operations in clause 24.1.4
selected according to relay function in the appliance
(IEC 60335-1/A2).....................................................:
24.2 No switches or automatic controls in flexible cords P
No devices causing protective device in fixed wiring to P
operate in event of a fault in appliance
No thermal cut-outs that can be reset by soldering P
24.3 Switches intended for all-pole disconnection of N
stationary appliances are directly connected to supply
terminals and having a contact separation in all poles,
providing full disconnection under overvoltage
category III conditions
24.4 Plugs and socket-outlets for extra-low voltage circuits N
and heating elements, not interchangeable with plugs
and socket-outlets listed in IEC 60083 or IEC 60906-1
or with connectors and appliance inlets complying with
standard sheets of IEC 60320-1
24.5 Capacitors in auxiliary windings of motors marked N
with their rated voltage and capacitance and used
accordingly

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 33 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Voltage across capacitors in series with a motor N


winding not exceed 1,1 times rated voltage, when
appliance is supplied at 1,1 times rated voltage under
minimum load
24.6 Working voltage of motors connected to supply mains N
and having basic insulation that is inadequate for
rated voltage of appliance, not exceeding 42 V
In addition, motors complying with requirements of N
annex I
24.7 Hose-sets for connection of appliances to water N
mains, complying with IEC 61770 and supplied with
appliance (IEC 60335-1/A1)
24.101 Thermal cut-out or other protective device P
incorporated to comply with clause 22.106 be non-self
resetting and, for multi-phase appliances, provide
all-pole disconnection (IEC 60335-2-35)
Bare-element water heaters intended to be connected N
to power supply by supply cord fitted with
non-polarized plug (IEC 60335-2-35/A1),
thermal cut-out or other protected device incorporated N
in the appliance shall provide all-pole disconnection
(IEC 60335-2-35/A1)
24.102 Thermal cut-out or other protective device, N
incorporated for compliance with clause 22.106 in
closed water heaters with capacity not exceeding 1 l,
maintain its operating characteristics
(IEC 60335-2-35)
Appliance supplied at rated voltage and operated N
under normal operation but with any control operates
during test of clause 11 short-circuited
(IEC 60335-2-35)
Water flow adjusted that temperature of water N
increases by approximately 1 K per minute
(IEC 60335-2-35)
Thermal cut-out caused to operate five times, N
1 5
temperatures at which it operates measured and  xi 
5 i1
mean value determined (IEC 60335-2-35) ............. :
Thermal cut-out subjected to 50000 cycles of N
temperature fluctuation (IEC 60335-2-35)
Each cycle consists of variation in temperature N
between maximum value measured during test of
clause 22.107 and half this value (IEC 60335-2-35)
Thermal cut-out then caused to operate 20 times and N
1 20
mean value of temperatures at which it operates not  xi 
20 i1
deviate by more than 20 % from mean value
previously determined (IEC 60335-2-35) ................ :
Deviation:

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 34 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Protective device sensitive to pressure, appliance is N


not energized and subjected to slowly increasing
water pressure (IEC 60335-2-35)
Mean operating pressure of protective device N
1 5
determined over five cycles (IEC 60335-2-35) ........ :  xi 
5 i1
Protective device subjected to 50000 cycles of N
pressure fluctuation (IEC 60335-2-35)
Each cycle consists of a variation in pressure between N
rated pressure of appliance and half this value
(IEC 60335-2-35)
Protective device then caused to operate 20 times N
1 20
and mean value of pressures at which it operates not  xi 
20 i1
deviate by more than 20 % from mean value
previously determined (IEC 60335-2-35) ................ :
Deviation:

25 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS —


25.1 Appliance not intended for permanent connection to fixed wiring, means for connection —
to supply mains:
- supply cord fitted with a plug N
- an appliance inlet having at least the same degree of N
protection against moisture as required for appliance
- pins for insertion into socket-outlets N

25.2 Appliance not provided with more than one means of P


connection to supply mains
Stationary appliance for multiple supply may be N
provided with more than one means of connection,
provided electric strength test of 1250 V for 1 min
between each means of connection causes no
breakdown
25.3 Connection of supply conductors for appliance P
intended to be permanently connected to fixed wiring
possible after the appliance has been fixed to its
support
Appliance provided with a set of terminals for N
connection of cables or fixed wiring, cross-sectional
areas (mm²) specified in clause 26.6 ......................... :
Appliance provided with a set of terminals allowing P
connection of a flexible cord
Appliance provided with a set of supply leads N
accommodated in a suitable compartment
Appliance provided with a set of terminals and cable N
entries, conduit entries, knock-outs or glands, allowing
connection of appropriate type of cable or conduit

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 35 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

25.4 Cable and conduit entries, rated current of appliance N


not exceeding 16 A, dimensions according to table 10
(mm) ........................................................................... :
Introduction of conduit or cable does not reduce N
clearances or creepage distances below values in
clause 29
25.5 Method for assemble supply cord with the appliance: —
- type X attachment N

- type Y attachment P

- type Z attachment N

Type X attachment, other than those with a specially N


prepared cord, not used for flat twin tinsel cords
25.6 Plugs fitted with only one flexible cord N
25.7 Supply cords being one of the following types (IEC 60335-1/A2): —
- rubber sheathed (at least 60245 IEC 53) N
(IEC 60335-1/A2)
- polychloroprene sheathed (at least 60245 IEC 57) N
(IEC 60335-1/A2)
- cross-linked polyvinyl chloride sheathed (at least N
60245 IEC 87) (IEC 60335-1/A2)
Polyvinyl chloride sheathed: —
Not used if they are likely to touch metal parts having a temperature rise exceeding 75 K
during clause 11 (IEC 60335-1/A2)
- light polyvinyl chloride sheathed cord (at least N
60227 IEC 52), appliances not exceeding 3 kg
(IEC 60335-1/A2)
- ordinary polyvinyl chloride sheathed cord (at least N
60227 IEC 53), other appliances (IEC 60335-1/A2)
Heat resistant polyvinyl chloride sheathed: —
Not used for type X attachment other than specially prepared cords (IEC 60335-1/A2)
- heat-resistant light polyvinyl chloride sheathed cord N
(at least 60227 IEC 56), appliances not exceeding
3 kg (IEC 60335-1/A2)
- heat-resistant polyvinyl chloride sheathed cord See table 24.1 P
(60227 IEC 57), other appliances (IEC 60335-1/A2)
25.8 Nominal cross-sectional area of supply cords See table 24.1 P
according to table 11; rated current (A);
cross-sectional area (mm²) ........................................ :
25.9 Supply cord not in contact with sharp points or edges P
25.10 Green/yellow core for earthing purposes in class I P
appliance

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 36 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

25.11 Conductors of supply cords not consolidated by P


lead-tin soldering where they are subject to contact
pressure, unless
clamping means so constructed that there is no risk of P
bad contacts due to cold flow of solder
25.12 Moulding cord to part of enclosure not damage P
insulation of supply cord
25.13 Inlet opening so shaped as to prevent damage to P
supply cord
Unless enclosure at the inlet opening is of insulation N
material, a non-detachable lining or bushing
complying with clause 29.3 for supplementary
insulation provided
If unsheathed supply cord, a similar additional bushing N
or lining is required, unless
the appliance is class 0 N
25.14 Supply cords adequately protected against excessive N
flexing
Flexing test: —
- applied force (N) ....................................................... : N
- number of flexings .................................................... : N
The test does not result in: —
- short-circuit between conductors N

- breakage of more than 10 % of strands of any N


conductor
- separation of conductor from its terminal N

- loosening of any cord guard N

- damage, within the meaning of the standard, to cord N


or cord guard
- broken strands piercing insulation and becoming N
accessible
25.15 Conductors of supply cord relieved from strain, P
twisting and abrasion by use of cord anchorage
Cord cannot be pushed into appliance to such an P
extent that cord or internal parts of appliance can be
damaged
Pull and torque test of supply cord, values shown in 100N, 0.35Nm P
table 10: pull (N); torque (not on automatic cord reel)
(Nm) ............................................................................ :
Max. 2 mm displacement of cord P

Creepage distances and clearances not reduced P


below values in clause 29.1

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 37 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

25.16 Cord anchorages for type X attachments constructed and located so that: —
- replacement of the cord is easily possible N

- it is clear how the relief from strain and prevention of N


twisting are obtained
- they are suitable for different types of cord N

- cord cannot touch the clamping screws of cord N


anchorage if these screws are accessible, unless
separated from accessible metal parts by
supplementary insulation
- cord is not clamped by a metal screw which bears N
directly on cord
- at least one part of cord anchorage securely fixed to N
appliance, unless
part of a specially prepared cord N

- screws which have to be operated when replacing N


cord do not fix any other component
- if labyrinths can be bypassed the test of clause 25.15 N
is nevertheless withstood
- class 0, 0I and I appliances: they are of insulating N
material or are provided with an insulating lining,
unless
a failure of the insulation of cord does not make N
accessible metal parts live
- class II appliances: they are of insulating material, or N
if of metal, they are insulated from accessible metal
parts by supplementary insulation
Conductors not moved more than 1 mm in terminals N

25.17 Adequate cord anchorages for type Y and Z P


attachment
25.18 Cord anchorages only accessible with aid of a tool, or P

so constructed that cord can only be fitted with aid of a P


tool
25.19 Type X attachment, glands not used as cord N
anchorage in portable appliances
Tying the cord into a knot or tying cord with string not N
used
25.20 Conductors of supply cord for type Y and Z P
attachment adequately additionally insulated

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 38 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

25.21 Space for supply cord for type X attachment or for N


connection of fixed wiring constructed to permit
checking of conductors with respect to correct
positioning and connection before fitting any cover, no
risk of damage to the conductors when fitting the
cover, no contact with accessible metal parts if a
conductor becomes loose, etc.
Portable appliances, uninsulated end of a conductor N
prevented from any contact with accessible metal
parts, unless end of cord is such that conductors
unlikely to slip free
25.22 Appliance inlet: —
- live parts not accessible during insertion or removal N

- connector can inserted without difficulty N

- appliance not supported by connector N

- not for cold conditions if temperature rise of external N


metal parts exceeds 75 K, unless supply cord is not
likely to touch such metal parts
25.23 Interconnection cords comply with requirements for N
supply cord, except as specified
if necessary, electric strength test of clause 16.3 N

25.24 Interconnection cords not detachable without aid of N


tool if compliance with standard is impaired when they
disconnected
25.25 Dimensions of pins compatible with dimensions of N
relevant socket-outlet. Dimensions of pins and
engagement face in accordance with relevant plug in
IEC 60083

26 TERMINALS FOR EXTERNAL CONDUCTORS —


26.1 Appliances provided with terminals or equally effective P
devices for connection of external conductors
Terminals only accessible after removal of a P
non-detachable cover
However, earthing terminals be accessible if a tool is P
required to make connections and means are
provided to clamp wire independently from its
connection (IEC 60335-1/A1)
26.2 Appliances with type X attachment and appliances for P
connection to fixed wiring provided with terminals in
which connections are made by means of screws,
nuts or similar devices, unless connections are
soldered
Screws and nuts serve only to clamp supply P
conductors, except

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 39 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

internal conductors, if so arranged that they unlikely to P


be displaced when fitting the supply conductors
If soldered connections used, conductor so positioned N
or fixed that reliance is not placed on soldering alone
Soldering alone used, barriers provided, clearances N
and creepage distances satisfactory if conductor
becomes free at soldered joint
26.3 Terminals for type X attachment and for connection to P
fixed wiring so constructed that conductor is clamped
between metal surfaces with sufficient contact
pressure and without damaging conductor
Terminals for type X attachment and those for connection to fixed wiring so fixed that —
when tightening or loosening the clamping means:
- terminal does not loosen P

- internal wiring not subjected to stress P

- clearances and creepage distances not reduced P


below values in clause 29
Compliance checked by inspection and by the test of P
subclause 9.6 of IEC 60999-1, torque applied being
equal to two-thirds of torque specified. Nominal
diameter of thread (mm); screw category; torque (Nm)
(IEC 60335-1/A2)........................................................ :
26.4 Terminals for type X attachment, except those with a P
specially prepared cord, and those for connection to
fixed wiring, no special preparation of conductors
required, and so constructed or placed that
conductors prevented from slipping out
26.5 Terminals for type X attachment so located or P
shielded that if a wire of a stranded conductor
escapes, no risk of accidental connection to other
parts that result in a hazard
Stranded conductor test, 8 mm insulation removed P

No contact between live parts and accessible metal P


parts and, for class II constructions, between live parts
and metal parts separated from accessible metal
parts by supplementary insulation only
26.6 Terminals for type X attachment and for connection to P
fixed wiring suitable for connection of conductors with
required cross-sectional area according to table 13;
rated current (A); nominal cross-sectional area (mm²)
(IEC 60335-1/A2)........................................................ :
Terminals only suitable for a specially prepared cord P
26.7 Terminals for type X attachment accessible after P
removal of a cover or part of enclosure
26.8 Terminals for connection to fixed wiring, including the P
earthing terminal, located close to each other

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 40 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

26.9 Terminals of pillar type constructed and located as P


specified
26.10 Terminals with screw clamping and screwless P
terminals not used for flat twin tinsel cords, unless
conductors ends fitted with a device suitable for screw
terminals
Pull test of 5 N to connection P
26.11 Type Y and Z attachment: soldered, welded, crimped P
and similar connections may be used
Class II appliances: conductor so positioned or fixed N
that reliance not placed on soldering, welding or
crimping alone
Class II appliances: soldering, welding or crimping N
alone used, barriers provided, clearances and
creepage distances satisfactory if conductor becomes
free

27 PROVISION FOR EARTHING —


27.1 Accessible metal parts of class 0I and I appliances, N
permanently and reliably connected to an earthing
terminal or contact of appliance inlet
Earthing terminals not connected to neutral terminal P
Class 0, II and III appliance have no provision for N
earthing
Safety extra-low voltage circuits not earthed, unless N
protective extra-low voltage circuits
Class I appliances, sheath of heating element be P
permanently and reliably connected to earthing
terminal, unless (IEC 60335-2-35/A1)
- container provided with inlet and outlet pipes of N
metal, which permanently and reliably connected to
earthing terminal, and (IEC 60335-2-35/A1)
- other accessible metal parts of container in contact N
with water permanently and reliably connected to
earthing terminal (IEC 60335-2-35/A1)
Class I bare-element water heaters, water enter and N
leave through metal pipes that permanently and
reliably connected to earthing terminal or flow over
metal parts similarly earthed (IEC 60335-2-35)
27.2 Clamping means adequately secured against P
accidental loosening
Terminals used for the connection of external N
equipotential bonding conductors allow connection of
conductors of 2,5 to 6 mm², and

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 41 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

do not provide earthing continuity between different N


parts of appliance
Conductors cannot be loosened without aid of tool N
27.3 Detachable parts plugged into another part of N
appliance, and having earth connection, earth
connection made before and separated after
current-carrying connections when removing part
(IEC 60335-1/A1)
Appliances with supply cord, current-carrying P
conductors become taut before earthing conductor, if
cord slips out of cord anchorage
27.4 No risk of corrosion resulting from contact between P
metal of earthing terminal and other metal
Adequate resistance to corrosion of coated or P
uncoated parts providing earthing continuity, other
than parts of a metal frame or enclosure
Parts of steel providing earthing continuity provided at N
essential areas with an electroplated coating,
thickness at least 5 µm
Adequate protection against rusting of parts of coated P
or uncoated steel, only intended to provide or transmit
contact pressure
In case of aluminium alloys precautions taken to avoid N
risk of corrosion
27.5 Low resistance of connection between earthing P
terminal and earthed metal parts
Requirement does not apply to connections providing P
earthing continuity in the protective extra-low voltage
circuit, provided that clearances of basic insulation
based on rated voltage of appliance
Resistance not exceeding 0,1 Ω at specified 0.047 Ω P
low-resistance test (Ω)................................................ :
27.6 Printed conductors of printed circuit boards not used N
to provide earthing continuity in hand-held appliances
They may be used to provide earthing continuity in N
other appliances if at least two tracks used with
independent soldering points and appliance
complies with clause 27.5 for each circuit

28 SCREWS AND CONNECTIONS —


28.1 Fixings, electrical connections and connections P
providing earthing continuity withstand mechanical
stresses
Screws not of soft metal liable to creep, such as zinc P
or aluminium
Diameter of screws of insulating material min. 3 mm N
Waltek Services (Shenzhen) Co., Ltd.
http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 42 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Screws of insulating material not used for any P


electrical connection or connections providing
earthing continuity
Screws used for electrical connections or connections P
providing earthing continuity screw into metal
Screws not of insulating material if their replacement N
by a metal screw can impair supplementary or
reinforced insulation
Type X attachment, screws to be removed for P
replacement of supply cord or for user maintenance,
not of insulating material if their replacement by a
metal screw can impair basic insulation
For screws and nuts; test as specified (See appended table) P
(IEC 60335-1/A2)
28.2 Electrical connections and connections providing P
earthing continuity constructed so that contact
pressure not transmitted through insulating material
liable to shrink or distort, unless shrinkage or distortion
compensated
Requirement does not apply to electrical connections N
in circuits carrying a current not exceeding 0,5 A
28.3 Space-threaded (sheet metal) screws only used for N
electrical connections if they clamp parts together
Thread-cutting (self-tapping) screws and thread rolling N
screws only used for electrical connections if they
generate a full form standard machine screw thread
(IEC 60335-1/A2)
However, thread-cutting (self-tapping) screws not N
used if they likely to be operated by user or installer
(IEC 60335-1/A2)
Thread-cutting, thread rolling and space threaded screws may be used in connections —
providing earthing continuity provided it is not necessary to disturb connection
(IEC 60335-1/A2):
- in normal use (IEC 60335-1/A2), N
- during user maintenance (IEC 60335-1/A2), N
- when replacing a supply cord having a type X N
attachment, or (IEC 60335-1/A2)
- during installation (IEC 60335-1/A2) N
At least two screws being used for each connection N
providing earthing continuity, unless
(IEC 60335-1/A2)
screw forms a thread having a length of at least half N
diameter of screw (IEC 60335-1/A2)

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 43 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

28.4 Screws and nuts that make mechanical connection P


secured against loosening if they also make electrical
connections or connections providing earthing
continuity
Rivets for electrical connections or connections N
providing earthing continuity secured against
loosening if subjected to torsion

29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION —


Clearances, creepage distances and solid insulation P
withstand electrical stress
Coatings used on printed circuits boards to protect N
microenvironment (Type 1 coating) or
(IEC 60335-1/A2)
to provide basic insulation (Type 2 coating), annex J N
applies (IEC 60335-1/A2)
Microenvironment is pollution degree 1 under Type 1 N
coating (IEC 60335-1/A2)
No clearance or creepage distance requirements N
under Type 2 coating (IEC 60335-1/A2)
29.1 Clearances not less than values in table 16, taking P
into account the rated impulse voltage for overvoltage
categories of table 15, unless (IEC 60335-1/A1)
for basic insulation and functional insulation they N
comply with impulse voltage test of clause 14
(IEC 60335-1/A1)
However, if construction is affected by wear, N
distortion, movement of parts or during assembly,
clearances for rated impulse voltages of 1500 V and
above are increased by 0,5 mm and impulse voltage
test is not applicable (IEC 60335-1/A1)
Impulse voltage test is not applicable when (IEC 60335-1/A1): —
- microenvironment is pollution degree 3 or P
(IEC 60335-1/A1)
- for basic insulation of class 0 and 0I appliance N
(IEC 60335-1/A1)
Appliances are in overvoltage category II P
Compliance is checked by inspection and (See appended table) P
measurements as specified (IEC 60335-1/A1)
29.1.1 Clearances of basic insulation withstand P
overvoltages, taking into account rated impulse
voltage
Clearance at terminals of tubular sheathed heating P
elements may be reduced to 1 mm if
microenvironment is pollution degree 1

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 44 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Lacquered conductors of windings considered to be P


bare conductors (IEC 60335-1/A1)
29.1.2 Clearances of supplementary insulation not less than P
those specified for basic insulation in table 16
29.1.3 Clearances of reinforced insulation not less than P
those specified for basic insulation in table 16, but
using next higher step for rated impulse voltage
29.1.4 Functional insulation, table 16 is applicable, unless P
appliance complies with clause 19 with functional N
insulation short-circuited
Lacquered conductors of windings considered to be P
bare conductors (IEC 60335-1/A1)
However, clearances at crossover points not P
measured (IEC 60335-1/A1)
Clearance between surfaces of PTC heating N
elements reduced to 1 mm
29.1.5 Appliances having higher working voltage than rated N
voltage, voltage used for determining clearances from
table 16 is sum of rated impulse voltage and
difference between the peak value of the working
voltage and peak value of rated voltage
If secondary winding of a step-down transformer is N
earthed, or if there is an earthed screen between
primary and secondary windings, clearances of basic
insulation on secondary side not less than those
specified in table 16, but using the next lower step for
rated impulse voltage
Circuits supplied with voltage lower than rated voltage, N
clearances of functional insulation based on the
working voltage used as rated voltage in table 15
29.2 Creepage distances not less than those appropriate P
for the working voltage, taking into account material
group and pollution degree
Pollution degree 2 applies, unless N
precautions taken to protect insulation; pollution N
degree 1
insulation subjected to conductive pollution; pollution P
degree 3
Compliance is checked by inspection and P
measurements as specified
29.2.1 Creepage distances of basic insulation not less than (See appended table) P
table 17
Pollution degree 1, creepage distance not less than N
minimum clearance in table 16, if clearance has been
checked according to test of clause 14

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 45 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

29.2.2 Creepage distances of supplementary insulation at (See appended table) P


least as specified for basic insulation in table 17
29.2.3 Creepage distances of reinforced insulation at least (See appended table) P
double as specified for basic insulation in table 17
29.2.4 Creepage distances of functional insulation not less (See appended table) P
than table 18
Creepage distances may be reduced if appliance N
complies with clause 19 with functional insulation
short-circuited
29.3 Supplementary and reinforced insulation having P
adequate thickness, or a sufficient number of layers,
to withstand electrical stresses (IEC 60335-1/A1)
Compliance checked by (IEC 60335-1/A1): —
- measurement, in accordance with clause 29.3.1, or P
(IEC 60335-1/A1)
- electric strength test in accordance with N
clause 29.3.2, or (IEC 60335-1/A1)
- an assessment of thermal quality of material N
combined with an electric strength test, in
accordance with clause 29.3.3 (IEC 60335-1/A1)
29.3.1 Supplementary insulation having a thickness of at P
least 1 mm (IEC 60335-1/A1)
Reinforced insulation having a thickness of at least P
2 mm (IEC 60335-1/A1)
29.3.2 Each layer of material withstand electric strength test N
of clause 16.3 for supplementary insulation
(IEC 60335-1/A1)
Supplementary insulation consisting of at least N
2 layers (IEC 60335-1/A1)
Reinforced insulation consisting of at least 3 layers N
(IEC 60335-1/A1)
29.3.3 Insulation is subjected to dry heat test Bb of N
IEC 60068-2-2, followed by (IEC 60335-1/A1)
electric strength test of clause 16.3 (IEC 60335-1/A1) N

If temperature rise during tests of clause 19 not N


exceed value in table 3, test of IEC 60068-2-2 is not
carried out (IEC 60335-1/A1)

30 RESISTANCE TO HEAT AND FIRE —


30.1 External parts of non-metallic material, P
parts supporting live parts, and P
thermoplastic material providing supplementary or P
reinforced insulation,

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 46 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

sufficiently resistant to heat P


Ball-pressure test according to IEC 60695-10-2 P
External parts: at 40 C plus maximum temperature (See appended table) P
rise determined during test of clause 11, or at 75 C,
whichever is higher; temperature (C) ....................... :
Parts supporting live parts: at 40C plus maximum (See appended table) P
temperature rise determined during test of clause 11,
or at 125C, whichever is higher; temperature (C) ... :
However, for parts of thermoplastic material providing (See appended table) P
supplementary or reinforced insulation, 25 C plus
maximum temperature rise determined during
clause 19, if higher; temperature (C) ........................ :
30.2 Parts of non-metallic material adequately resistant to (See appended table) P
ignition and spread of fire
Requirement does not apply to decorative trims, P
knobs and other parts unlikely to be ignited or to
propagate flames that originate inside the appliance
Compliance checked by test of clause 30.2.1. In addition: —
- attended appliances, clause 30.2.2 N
- unattended appliances, clause 30.2.3 applies P
Appliances for remote operation, clause 30.2.3 N
applies (IEC 60335-1/A2)
Base material of printed circuit board, clause 30.2.4 P
applies
30.2.1 Glow-wire test of IEC 60695-2-11 at 550 C, unless P
material is classified at least HB40 according to N
IEC 60695-11-10 (IEC 60335-1/A2)
Parts for which glow-wire test cannot be carried out, N
meet requirements in ISO9772 for category HBF
material
30.2.3 Appliances operated while unattended, tested as P
specified in clause 30.2.3.1 and 30.2.3.2
Test not carried out by specified items ...................... : For all specified items P
30.2.3.1 Not applicable to parts of insulating material N
supporting heating elements and their connections of
bare-element water heaters (IEC 60335-2-35/A1)
Parts of non-metallic material supporting connections P
carrying a current exceeding 0,2 A during normal
operation, and (IEC 60335-1/A2)
parts of non-metallic material within a distance of P
3 mm, (IEC 60335-1/A2)
subjected to glow-wire test of IEC 60695-2-11 with a P
test severity of 850 °C (IEC 60335-1/A2)

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 47 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

However, glow-wire test not carried out on parts of N


material classified as having a glow-wire flammability
index of at least 850 °C according to IEC 60695-2-12
(IEC 60335-1/A2)
Glow-wire flammability index only used if in specified N
range of thickness (IEC 60335-1/A2)
Glow-wire test not carried out on small parts comply N
with needle-flame test of annex E or on small parts of
material classified as V-0 or (IEC 60335-1/A2)
V-1 according to IEC 60695-1-10 (IEC 60335-1/A2) N
Classified V-0 or V-1 material only used if in specified N
range of thickness (IEC 60335-1/A2)
Test as specified for an interposed shielding material N
(IEC 60335-1/A2)
30.2.3.2 Bare-element water heaters, glow wire test carried out N
on parts of insulating material supporting heating
elements and their connections as specified for other
connections (IEC 60335-2-35/A1)
Parts of non-metallic material supporting P
current-carrying connections, and (IEC 60335-1/A2)
parts of non-metallic material within a distance of P
3 mm, (IEC 60335-1/A2)
subjected to glow-wire test of IEC 60695-2-11 P
However, glow-wire test not carried out on material having a glow-wire ignition —
temperature according to IEC 60695-2-13 of at least:
- 775 C, for connections carrying a current exceeding N
0,2 A during normal operation
- 675 C, for other connections N

Glow-wire ignition temperature only used if in N


specified range of thickness (IEC 60335-1/A2)
Test as specified for an interposed shielding material N
(IEC 60335-1/A2)
When glow-wire test of IEC 60695-2-11 carried out, temperatures are: —
- 750 C, for connections carrying a current exceeding P
0,2 A during normal operation
- 650 C, for other connections N
If a flame persists longer than 2 s during test, then N
these parts and adjacent parts further subjected to
needle-flame test of annex E, unless (IEC 60335-1/A1
corr.1)
material is classified as V-0 or V-1 according to N
IEC 60695-11-10 (IEC 60335-1/A2)
Classified V-0 or V-1 material only used if in specified N
range of thickness (IEC 60335-1/A2)
Waltek Services (Shenzhen) Co., Ltd.
http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 48 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

30.2.4 Base material of printed circuit boards subjected to P


needle-flame test of annex E (IEC 60335-1/A2)
Test not carried out by specified items ...................... : P

31 RESISTANCE TO RUSTING —
Relevant ferrous parts adequately protected against P
rusting

32 RADIATION, TOXICITY AND SIMILAR HAZARDS —


Appliance not emit harmful radiation, present a toxic P
or similar hazard due to their operation in normal use
(IEC 60335-1/A2)
Relevant tests specified in part 2, if necessary N
(IEC 60335-1/A2)

A ANNEX A (INFORMATIVE) —
ROUTINE TESTS
Description of routine tests to be carried out by N
manufacturer (IEC 60335-1, IEC 60335-2-35)

B ANNEX B (NORMATIVE) —
APPLIANCES POWERED BY RECHARGEABLE BATTERIES
Following modifications to this standard are applicable for appliances powered by N
batteries that recharged in appliance:
This annex does not apply to battery chargers N
3.1.9 Appliance operated under the following conditions: —
- appliance, supplied by its fully charged battery, N
operated as specified in relevant part 2
- battery is charged, battery being initially discharged N
to such an extent that appliance cannot operate
- if possible, appliance is supplied from supply mains N
through its battery charger, battery being initially
discharged to such an extent that appliance cannot
operate. Appliance operated as specified in relevant
part 2
If appliance incorporates inductive coupling between N
two parts that detachable from each other, appliance
is supplied from supply mains with detachable part
removed
3.6.2 Part to be removed in order to discard the battery is N
not considered to be detachable
5.101 Appliances supplied from supply mains tested as N
specified for motor-operated appliances
Waltek Services (Shenzhen) Co., Ltd.
http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 49 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

7.1 Battery compartment for batteries intended to be N


replaced by user, marked with battery voltage and
polarity of terminals
7.12 Instructions for appliances incorporating batteries N
intended to be replaced by user includes required
information
Details about how to remove batteries containing N
materials hazardous to environment given
7.15 Markings placed on part of appliance connected to N
supply mains
8.2 Appliances having batteries that according to N
instruction may be replaced by user need only have
basic insulation between live parts and inner surface
of battery compartment
If appliance can be operated without batteries, double N
or reinforced insulation required
11.7 Battery is charged for period described N

19.1 Appliances subjected to tests of clause 19.101, N


19.102 and 19.103
19.101 Appliances supplied at rated voltage for 168 h, battery N
being continually charged
19.102 Short-circuiting of terminals of battery, being fully N
charged, for appliances having batteries that can be
removed without aid of tool
19.103 Appliances having batteries replaceable by user N
supplied at rated voltage under normal operation with
battery removed or in any position allowed by
construction
21.101 Appliances having pins for insertion into N
socket-outlets have adequate mechanical strength,
checked according to procedure 2 of IEC 60068-2-32
Part of the appliance incorporating the pins subjected to the free fall test, procedure 2, of —
IEC 60068-2-32, number of falls being:
- 100, mass of part does not exceed 250 g N

- 50, mass of part exceeds 250 g N

After test, requirements of clause 8.1, 15.1.1, 16.3 N


and 29 are met
22.3 Appliances having pins for insertion into N
socket-outlets tested as fully assembled as possible
25.13 An additional lining or bushing not required for N
interconnection cords operating at safety extra-low
voltage
30.2 Parts of appliance connected to supply mains during N
the charging period, clause 30.2.3 applies
Other parts, clause 30.2.2 applies N
Waltek Services (Shenzhen) Co., Ltd.
http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 50 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

C ANNEX C (NORMATIVE) —
AGEING TEST ON MOTORS
Tests, as described, carried out when doubt with N
regard to temperature classification of insulation of a
motor winding

D ANNEX D (NORMATIVE) —
THERMAL MOTOR PROTECTORS
Applicable to appliances having motors that incorporate thermal motor protectors N
(IEC 60335-1/A1)
Appliance is supplied at rated voltage with rotor of N
motor locked (IEC 60335-1/A1)
Duration of test as follows (IEC 60335-1/A1): —
- motors with self-resetting thermal motor protectors N
operated for 300 cycles or (IEC 60335-1/A1)
for 72 h whichever occurs first unless N
(IEC 60335-1/A1)
they likely permanently subjected to supply voltage in N
which case duration is 432 h (IEC 60335-1/A1)
- motors with non-self-resetting thermal motor N
protectors operated for 30 cycles, reset as soon as
possible but in not less than 30 s (IEC 60335-1/A1)
During test temperatures not exceed values specified N
in clause 19.7 (IEC 60335-1/A1)
Appliance comply with clause 19.13 (IEC 60335-1/A1) N

E ANNEX E (NORMATIVE) —
NEEDLE-FLAME TEST
Needle-flame test carried out in accordance with IEC 60695-11-5, with the following P
modifications (IEC 60335-1/A2):
7 Severities (IEC 60335-1/A2) —
Duration of application of test flame is 30 s ± 1 s P
(IEC 60335-1/A2)
9 Test procedure (IEC 60335-1/A2) —
9.1 Specimen so arranged that flame can be applied to a P
vertical or horizontal edge as shown in examples of
figure 1 (IEC 60335-1/A2)
9.2 First paragraph does not apply (IEC 60335-1/A2) P
If possible, flame is applied at least 10 mm from a P
corner (IEC 60335-1/A2)
9.3 Test carried out on one specimen (IEC 60335-1/A2) P

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 51 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

If specimen does not withstand test, test may be N


repeated on two additional specimens, both
withstanding test (IEC 60335-1/A2)
11 Evaluation of test results (IEC 60335-1/A2) —
The duration of burning not exceeding 30 s N
(IEC 60335-1/A2)
However, for printed circuit boards, the duration of P
burning not exceeding 15 s (IEC 60335-1/A2)

F ANNEX F (NORMATIVE) —
CAPACITORS
Capacitors likely to be permanently subjected to the supply voltage, and used for radio N
interference suppression or voltage dividing, comply with the following clauses of
IEC 60384-14, with following modifications:
1.5 Terminology —
1.5.3 Class X capacitors tested according to subclass X2 N

1.5.4 This subclause is applicable N

1.6 Marking —
Items a) and b) are applicable N
3.4 Approval testing —
3.4.3.2 Table II is applicable as described N
4.1 Visual examination and check of dimensions —
This subclause is applicable N
4.2 Electrical tests —
4.2.1 This subclause is applicable N

4.2.5 This subclause is applicable N

4.2.5.2 Only table IX is applicable N

Values for test A apply N

However, for capacitors in heating appliances the N


values for test B or C apply
4.12 Damp heat, steady state —
This subclause is applicable N

Only insulation resistance and voltage proof are N


checked
4.13 Impulse voltage —
This subclause is applicable N
4.14 Endurance —
Subclauses 4.14.1, 4.14.3, 4.14.4 and 4.14.7 N
applicable

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 52 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

4.14.7 Only insulation resistance and voltage proof are N


checked
Visual examination, no visible damage N
4.17 Passive flammability test —
This subclause is applicable N
4.18 Active flammability test —
This subclause is applicable N
N
G ANNEX G (NORMATIVE) —
SAFETY ISOLATING TRANSFORMERS
Following modifications to this standard are applicable for safety isolating transformers: N
7 Marking and instructions —
7.1 Transformers for specific use marked with: —
- name, trademark or identification mark of N
manufacturer or responsible vendor
- model or type reference N
17 Overload protection of transformers and associated circuits —
Fail-safe transformers comply with subclause 15.5 of For BYQ-RSQ003 N
IEC 61558-1
22 Construction —
Subclauses 19.1 and 19.1.2 of IEC 61558-2-6 are N
applicable
29 Clearances, creepage distances and solid insulation —
29.1, 29.2 Distances specified in items 2a, 2c and 3 in table 13 of N
and 29.3 IEC 61558-1 apply (IEC 60335-1 corr.1)

H ANNEX H (NORMATIVE) —
SWITCHES
Switches comply with following clauses of IEC 61058-1, as modified: N
- Tests of IEC 61058-1 carried out under conditions N
occurring in appliance
- Before being tested, switches are operated 20 times N
without load
8 Marking and documentation —
Switches not required to be marked N

However, switches that can be tested separately from N


appliance marked with manufacturer’s name or trade
mark and type reference
13 Mechanism —

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 53 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Tests may be carried out on a separate sample N


15 Insulation resistance and dielectric strength —
15.1 Not applicable N
15.2 Not applicable N

15.3 Applicable for full disconnection and N


micro-disconnection
17 Endurance —
Compliance is checked on three separate appliances N
or switches
For 17.2.4.4, the number of cycles is 10 000, unless N
otherwise specified in clause 24.1.3 of relevant part 2
of IEC 60335
Switches for operation under no load and which can N
be operated only by a tool and switches operated by
hand that are interlocked so that they cannot be
operated under load, are not subjected to tests
However switches without this interlock subjected to N
test of subclause 17.2.4.4 for 100 cycles
Subclause 17.2.2 and 17.2.5.2 not applicable N
(IEC 60335-1/A1)
Ambient temperature during test is that occurring in N
appliance during test of clause 11 in IEC 60335-1
(IEC 60335-1/A1)
Temperature rise of terminals not more than 30 K N
above temperature rise measured in clause 11 of
IEC 60335-1, specified in footnote b of table 3
20 Clearances, creepage distances, solid insulation and coatings of rigid printed board —
assemblies
This clause is applicable to clearances and creepage N
distances for functional insulation, across full
disconnection and micro-disconnection, as stated in
table 24

I ANNEX I (NORMATIVE) —
MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE RATED
VOLTAGE OF THE APPLIANCE
Following modifications to this standard are applicable for motors having basic N
insulation that is inadequate for the rated voltage of the appliance:
8 Protection against access to live parts —
8.1 Metal parts of the motor are considered to be bare live N
parts
11 Heating —

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 54 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

11.3 Temperature rise of body of motor is determined N


instead of temperature rise of windings
11.8 Temperature rise of body of motor, where in contact N
with insulating material, not exceeding values in
table 3 for the relevant insulating material
16 Leakage current and electric strength —
16.3 Insulation between live parts of the motor and its other N
metal parts not subjected to test
19 Abnormal operation —
19.1 Tests of clause 19.7 to 19.9 not carried out N
19.101 Appliance operated at rated voltage with each of the following fault conditions: —
- short-circuit of terminals of the motor, including any N
capacitor incorporated in motor circuit
- short-circuit of each diode of rectifier N
- open-circuit of supply to motor N
- open-circuit of any parallel resistor, motor being in N
operation
Only one fault simulated at a time, tests carried out N
consecutively
22 Construction —
22.101 Class I appliances incorporating a motor supplied by a N
rectifier circuit, d.c. circuit being insulated from
accessible parts of appliance by double or reinforced
insulation
Compliance checked by tests specified for double and N
reinforced insulation

J ANNEX J (NORMATIVE) —
COATED PRINTED CIRCUIT BOARDS
Testing of protective coatings of printed circuit boards carried out in accordance with N
IEC 60664-3 with following modifications (IEC 60335-1/A2):
5.7 Conditioning of the test specimens (IEC 60335-1/A2) —
When production samples used, three samples of N
printed circuit board are tested (IEC 60335-1/A2)
5.7.1 Cold (IEC 60335-1/A2) —
Test carried out at -25 C (IEC 60335-1/A2) N
5.7.3 Rapid change of temperature (IEC 60335-1/A2) —
Severity 1 is specified (IEC 60335-1/A2) N
5.9 Additional tests (IEC 60335-1/A2) —
Subclause not applicable (IEC 60335-1/A2) N

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 55 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

K ANNEX K (NORMATIVE) —
OVERVOLTAGE CATEGORIES
Information on overvoltage categories is extracted P
from IEC 60664-1
Overvoltage category is a numeral defining a transient P
overvoltage condition
Equipment of overvoltage category IV is for use at N
origin of installation
Equipment of overvoltage category III is equipment in N
fixed installations and for cases where reliability and
availability of equipment is subject to special
requirements
Equipment of overvoltage category II is energy P
consuming equipment to be supplied from fixed
installation
If such equipment is subjected to special N
requirements with regard to reliability and availability,
overvoltage category III applies
Equipment of overvoltage category I is equipment for N
connection to circuits in which measures are taken to
limit transient overvoltages to an appropriate low level

L ANNEX L (INFORMATIVE) —
GUIDANCE FOR THE MEASUREMENT OF CLEARANCES AND CREEPAGE
DISTANCES
Sequences for determination of clearances and P
creepage distances

M ANNEX M (NORMATIVE) —
POLLUTION DEGREE
Information on pollution degrees is extracted from P
IEC 60664-1
Pollution —
Microenvironment determines effect of pollution on P
insulation, taking into account microenvironment
Means may be provided to reduce pollution at P
insulation by effective enclosures or similar
Minimum clearances specified where pollution may be P
present in microenvironment
Degrees of pollution in the microenvironment —
For evaluating creepage distances, following degrees of pollution in microenvironment —
are established:

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 56 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

- pollution degree 1: no pollution or only dry, N


non-conductive pollution occurs. Pollution has no
influence
- pollution degree 2: only non-conductive pollution N
occurs, except that occasionally a temporary
conductivity caused by condensation is to be
expected
- pollution degree 3: conductive pollution occurs or dry P
non-conductive pollution occurs that becomes
conductive due to condensation that is to be
expected
- pollution degree 4: pollution generates persistent N
conductivity caused by conductive dust or by rain or
snow

N ANNEX N (NORMATIVE) —
PROOF TRACKING TEST
Proof tracking test is carried out in accordance with IEC 60112 with following P
modifications (IEC 60335-1/A1):
7 Test apparatus (IEC 60335-1/A1) —
7.3 Test solutions (IEC 60335-1/A1) —
Test solution A is used (IEC 60335-1/A1) P
10 Determination of proof tracking index (PTI) (IEC 60335-1/A1) —
10.1 Procedure (IEC 60335-1/A1) —
Proof voltage is 100 V, 175 V, 400 V or 600 V 175 V P
(IEC 60335-1/A1)........................................................ :
Last paragraph of clause 3 applies (IEC 60335-1/A1) P
Test is carried out on five specimens P
(IEC 60335-1/A1)
In case of doubt, additional test with proof voltage N
reduced by 25 V, number of drops increased to 100
(IEC 60335-1/A1)
10.2 Report (IEC 60335-1/A1) —
Report stating if PTI value was based on a test using N
100 drops with a test voltage of (PTI-25) V
(IEC 60335-1/A1)

O ANNEX O (INFORMATIVE) —
SELECTION AND SEQUENCE OF THE TESTS OF CLAUSE 30
Description of tests for determination of resistance to P
heat and fire (IEC 60335-1/A2)

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 57 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

P ANNEX P (INFORMATIVE) —
GUIDANCE FOR THE APPLICATION OF THIS STANDARD TO APPLIANCES
USED IN WARM DAMP EQUABLE CLIMATES
Modifications applicable for class 0 and 0I appliances having rated voltage exceeding N
150 V, intended to be used in countries having a warm damp equable climate and
marked WDaE (IEC 60335-1/A1)
Modifications may also be applied to class I appliances having rated voltage exceeding N
150 V, intended to be used in countries having a warm damp equable climate and that
are marked WDaE, if liable to be connected to a supply mains that excludes protective
earthing conductor (IEC 60335-1/A1)
5 General conditions for the tests (IEC 60335-1/A1) —
5.7 Ambient temperature for the tests of clauses 11 and N
+3
13 is 40 /0 °C (IEC 60335-1/A1)
7 Marking and instructions (IEC 60335-1/A1) —
7.1 Appliance marked with the letters WDaE N
(IEC 60335-1/A1)
7.12 Instructions state that appliance is to be supplied N
through a RCD having a rated residual operating
current not exceeding 30 mA (IEC 60335-1/A1)
Instructions state that appliance is considered to be N
suitable for use in countries having a warm damp
equable climate, but may also be used in other
countries (IEC 60335-1/A1)
11 Heating (IEC 60335-1/A1) —
11.8 Values of table 3 reduced by 15 K (IEC 60335-1/A1) N
13 Leakage current and electric strength at operating temperature (IEC 60335-1/A1) —
13.2 Leakage current for class I appliances not exceed N
0,5 mA (IEC 60335-1/A1)
15 Moisture resistance (IEC 60335-1/A1) —
15.3 Value of t is 37 C (IEC 60335-1/A1) N
16 Leakage current and electric strength (IEC 60335-1/A1) —
16.2 Leakage current for class I appliances not exceed N
0,5 mA (IEC 60335-1/A1)
19 Abnormal operation (IEC 60335-1/A1) —
19.13 Leakage current test of clause 16.2 is applied in N
addition to electric strength test of 16.3
(IEC 60335-1/A1)

Q ANNEX Q (INFORMATIVE) —
SEQUENCE OF TESTS FOR THE EVALUATION OF ELECTRONIC CIRCUITS
Description of tests for appliances incorporating electronic circuits (IEC 60335-1/A2) —

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 58 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

R ANNEX R (NORMATIVE) —
SOFTWARE EVALUATION
Software evaluated in accordance with the following clauses of annex H of N
IEC 60730-1, as modified (IEC 60335-1/A1):
H.2 Definitions (IEC 60335-1/A1) —
Only definitions H.2.16 to H.2.20 applicable N
(IEC 60335-1/A1)
H.7 Information (IEC 60335-1/A1) —
Only footnotes 12) to 18) of Table 7.2, as modified, N
applicable (IEC 60335-1/A1)
Replace text of footnote 15) (IEC 60335-1/A1) N
H.11.12 Controls using software (IEC 60335-1/A1) —
All subclauses of H.11.12, as modified, except N
H.11.12.6 and H.11.12.6.1, applicable
(IEC 60335-1/A1)
Replace text in second paragraph (IEC 60335-1/A1) N

H.11.12.7 Delete text (IEC 60335-1/A1) N

H.11.12.7.1 Appliances using software class C having a single N


channel with self-test and monitoring structure,
manufacturer provides measures necessary to
address the fault/errors in safety related segments
and data (IEC 60335-1/A1)
H.11.12.8 Software fault/error detection occurs before N
compliance with clause 19.13 of IEC 60335-1 is
impaired (IEC 60335-1/A1)
H.11.12.8.1 Replace text (IEC 60335-1/A1) N

H.11.12.13 Software and safety related hardware under its control N


initializes and terminates before compliance with
clause 19.13 of IEC 60335-1 is impaired
(IEC 60335-1/A1)

EN 60335-2-35/A2:2011
7.12.1 Addition: P
In a multiple water outlet system where the water N
temperature can be set at each individual
water outlet, the instructions shall state the
substance of the following:
The system shall be installed so that the control for N
setting the water temperature in normal use installed
at a shower outlet shall take priority over any other
controls in the system that set the water temperature
in normal use at other water outlets.
22.47 Replacement: P

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 59 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

Appliances shall withstand the water pressure P


occurring in normal use.
Compliance is checked by subjecting the appliance P
to a water pressure o
– twice the rated pressure, for closed water heaters; N
– 0,15 MPa, for open-outlet water heaters. P
If an open-outlet water heater incorporates a valve N
that regulates the water flow, a water pressure of 2
MPa is applied to the inlet of the appliance, the valve
being closed.
Pressure-relief devices are rendered inoperative. P
The pressure is raised at a rate of 0,13 MPa/s to the
specified value and is maintained at that value for 5
min.
Water shall not leak from the appliance and there P
shall be no permanent deformation to such
an extent that compliance with this standard is
impaired.
22.48 Not applicable. P
22.50 Addition: N
The requirement is not applicable provided that the N
system is such that the shower outlet normal use
water temperature control takes precedence in
setting the system temperature. In the case of
systems with multiple shower outlets, the shower
with the lowest temperature setting shall take
precedence, the other shower outlets taking
precedence over non-shower outlets.
22.51 Addition: N
If the maximum temperature of the water obtainable N
from the system can exceed 55 oC, then
the requirement is not applicable provided that the
system is such that a shower outlet normal
use water temperature control takes precedence in
setting the system temperature. In the
case of systems with multiple shower outlets the
shower with the lowest temperature setting
shall take precedence, the other shower outlets
taking precedence over non-shower outlets.

22.102 Void. P

Deviation Report of IEC 60335-1:2010 from IEC 60335-1:2001+ A1:2004 + A2:2006


5 General conditions for the tests P

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 60 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

5.19 If a component or part of the appliance has both a N


self resetting feature and a non self-resetting feature
and if the non-self-resetting feature is not required in
order to comply with the standard, then appliances
incorporating such a component or part shall be
tested with the non-self-resetting feature rendered
inoperative.

7 MARKING AND INSTRUCTIONS P


7.1 Symbol IEC 60417-5180, for class III appliances, N
unless
the appliance is operated by batteries only N
7.4 Requirement met if frequent changes are not N
required and the rated voltage to which the appliance
is to be adjusted is determined from a wiring diagram
7.6 Correct symbols used P
Symbol for nature of supply placed next to rated P
voltage
Symbol for class II appliances placed unlikely to be N
confused with other marking
Units of physical quantities and their symbols P
according to international standardized system
7.7 Connection diagram fixed to appliances to be N
connected to more than two supply conductors and
appliances for multiple supply, unless
correct mode of connection is obvious N
7.10 This applies also to switches which are part of a P
control
If figures are used, the off position indicated by the N
figure 0
7.12 Details concerning precautions during user P
maintenance
For a part of class III construction supplied from a N
detachable power supply unit, the instructions state
that the appliance is only to be used with the unit
provided
Instructions for class III appliances state that it must N
only be supplied at SELV, unless
it is a battery-operated appliance, the battery being N
charged outside the appliance
7.12.1 Sufficient details for installation supplied P
For an appliance intended to be permanently N
connected to the water mains and not connected by
a hose-set, this is stated

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 61 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

7.12.6 If a non-self-resetting thermal cut-out is required in N


order to comply with the standard then the
instructions for appliances incorporating a
non-self-resetting thermal cut-out that is reset by
disconnection of the supply mains shall contain the
substance of the following:
CAUTION: In order to avoid a hazard due to N
inadvertent resetting of the thermal cut-out,
this appliance must not be supplied through an
external switching device, such as a timer, or
connected to a circuit that is regularly switched on
and off by the utility.

8 PROTECTION AGAINST ACCESS TO LIVE PARTS P


8.2 Test probe B of IEC 61032 is applied to built-in N
appliances and fixed appliances only after
installation.

11 HEATING P
11.8 The temperature rise limit for metal applies to parts P
having a metal coating at least 0,1 mm thick and to
metal parts having a plastic coating less than 0,3 mm
thick.

13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING P


TEMPERATURE
13.2 For class 0, class II and class III appliances, leakage N
current measured by means of the circuit described
in figure 4 of IEC 60990. For other appliances, a low
impedance ammeter may be used.

17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS N


Basic insulation is not short-circuited N

19 ABNORMAL OPERATION P
19.1 Appliances incorporating voltage selector switches N
subjected to the test of 19.15
19.9 Motor-operated and combined appliances for which N
30.2.3 is applicable and that use overload protective
devices relying on electronic circuits to protect the
motor windings, are also subjected to the test
19.11.4.6 Appliances having a rated current exceeding 16 A N
are subjected to the Class 3 voltage dips and
interruptions in accordance with IEC 61000-4-34

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 62 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

19.13 If the appliance contains lids or doors that are controlled by one or more interlocks, N
one of the interlocks may be released provided that:
- the lid or door does not move automatically to an N
open position when the interlock is released, and
- the appliance does not start after the cycle in which N
the interlock was released
19.15 For appliances with a mains voltage selector switch, N
the switch is set to the lowest rated voltage position
and the highest value of rated voltage is applied

20 STABILITY AND MECHANICAL HAZARDS P


20.2 Enclosures that can be opened by overriding an N
interlock are considered to be detachable parts

22 CONSTRUCTION P
22.24 Bare heating elements, other than those in class III N
appliances or class III constructions that do not
contain live parts, shall be supported so that the
heating conductor is unlikely to come into contact
with accessible metal parts if they rupture.
22.25 Appliances shall be constructed so that sagging N
heating conductors cannot come into contact with
accessible metal parts. This requirement does not
apply to class III appliances or class III constructions
that do not contain live parts.
22.33 For class II constructions, conductive liquids that are P
or may become accessible in normal use and
conductive liquids that are in contact with unearthed
accessible metal parts, not in direct contact with
basic or reinforced insulation, unless
the reinforced insulation consists of at least 3 layers N
For class II constructions, conductive liquids which P
are in contact with live parts, not in direct contact with
reinforced insulation, unless
the reinforced insulation consists of at least 3 layers N
An air layer not used as basic or supplementary P
insulation in a double insulation system if likely to be
bridged by leaking liquid
22.35 Insulating material covering metal handles, levers P
and knobs withstand the electric strength test of 16.3
for supplementary insulation
22.42 Resistors checked by the test of 14.1 a) in IEC 60065 N
Capacitors checked by the tests for class Y N
capacitors in IEC 60384-14

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 63 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

22.46 For programmable protective electronic circuits used N


to ensure compliance with the standard, the software
contains measures to control the fault/error
conditions in table R.1
Software that contains measures to control the N
fault/error conditions specified in table R.2 is to be
specified in parts 2 for particular constructions or to
address specific hazards
These requirements are not applicable to software N
used for functional purpose or compliance with
clause 11
23 INTERNAL WIRING P
23.3 Electric strength test of 16.3, 1000 V between live N
parts and accessible metal parts
Not more than 10% of the strands of any conductor N
broken, and
not more than 30% for wiring supplying circuits that N
consume no more than 15W
23.5 Basic insulation electrically equivalent to the basic N
insulation of cords complying with IEC 60227 or IEC
60245, or
23.6 Sleeving used as supplementary insulation on N
internal wiring retained in position by clamping at
both ends, or
be such that it can only be removed by breaking or N
cutting

24 COMPONENTS P
24.1 For components mentioned in 24.1.1 to 24.1.9 no P
additional tests specified in the relevant component
standard are necessary other than those specified in
24.1.1 to 24.1.9
No additional tests specified for nationally N
standardized plugs such as those detailed in IEC/TR
60083 or connectors complying with the standard
sheets of IEC 60320-1 and IEC 60309
24.1.3 If the switch only operates a motor staring relay N
complying with IEC 60730-2-10 with the number of
cycles of a least 10 000 as specified, the complete
switching system need not be tested
24.1.4 The number of cycles for controls operating during N
clause 11 need not be declared, if the appliance
meets the requirements of this standard when they
are short-circuited
24.2 Appliances not fitted with: N

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 64 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

- thermal cut-outs that can be reset by soldering, N


unless
the solder has a melding point of at least 230 ˚C N
24.7 Appliances intended to be permanently connected to N
the water mains shall not be connected by a
detachable hose-set
24.8 Motor running capacitors in appliances for which N
30.2.3 is applicable and that are permanently
connected in series with a motor winding, not
causing a hazard in event of a failure
One or more of the following conditions are to be met: N
- the capacitors are of class P2 according to IEC N
60252-1
- the capacitors are housed within a metallic or N
ceramic enclosure
- the distance of separation of the outer surface to N
adjacent non-metallic parts exceeds 50 mm
- adjacent non-metallic parts within 50 mm withstand N
the needle-flame test of Annex E
- adjacent non-metallic parts within 50 mm classified N
as at least V-1 according to IEC 60695-11-10

25 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS P


25.3 Appliance intended to be permanently connected to fixed wiring provided with one of P
the following means for connection to the supply mains:
- a set of terminals allowing the connection of a N
flexible cord
- a fitted supply cord P
- a set of supply leads accommodated in a suitable N
compartment
Appliances intended to be permanently connected to N
fixed wiring that are provided with
a set of terminals allowing the connection of cables N
of fixed wiring having the nominal cross-sectional
areas specified in 26.6, or
a set of terminals and cable entries, conduit entries, N
knock-outs or glands, which allow the connection of
the appropriate types of cable or conduit,
shall allow the connection of the supply conductors N
after the appliance has been fixed to its support.

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 65 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

If a fixed appliance is constructed so that parts can N


be removed to facilitate easy installation, this
requirement is considered to be met if it is possible to
connect the fixed wiring without difficulty after a part
of the appliance has been fixed to its support. In this
case, removable parts are to be constructed for ease
of reassembly without risk of incorrect assembly or
damage to the wiring or terminals.
25.5 Method for assembling the supply cord to the appliance: P
For multi-phase appliances supplied with a supply N
cord and that are intended to be permanently
connected to fixed wiring, the supply cord is
assembled to the appliance by type Y attachment
25.7 Supply cords, other than for class III appliances, being one of the following types: P
Supply cords for class III appliances adequately N
insulated
A voltage of 500 V is applied for 2 min between the P
conductor and metal foil wrapped around the
insulation, the insulation being at the temperature
measured during the test of Clause 11. There shall
be no breakdown during this test.
25.13 If unsheathed supply cord, a similar additional N
bushing or lining is required, unless the appliance is
class 0, or N
a class III appliance not containing live parts N
25.22 Appliance inlets: N
- live parts not accessible during insertion or removal N
Requirement not applicable to appliance inlets N
complying with IEC 60320-1

26 TERMINALS FOR EXTERNAL CONDUCTORS P


26.1 Terminals only accessible after removal of a P
non-detachable cover, except
for class III appliances that do not contain live parts N
26.2 Change ―connection to fixed wiring‖ to ―connection of N
cables of fixed wiring‖
26.3 Change ―connection to fixed wiring‖ to ―connection of N
cables of fixed wiring‖
26.4 Change ―connection to fixed wiring‖ to ―connection of N
cables of fixed wiring‖
26.6 Change ―connection to fixed wiring‖ to ―connection of N
cables of fixed wiring‖

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 66 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

28 SCREWS AND CONNECTIONS P


28.2 This requirement does not apply to electrical connections in circuits of appliances for N
which:
 30.2.2 is applicable and that carry a current N
not exceeding 0,5 A
 30.2.3 is applicable and that carry a current N
not exceeding 0,2 A

29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION P


For type 2 protection, the spacing between the N
conductors before the protection is applied is not
less than the values specified in Table 1 of IEC
60664-3
These values apply to functional, basic, P
supplementary and reinforced insulation .............. :
29.1.3 For double insulation, with no intermediate P
conductive part between basic and supplementary
insulation, clearances are measured between live
parts and the accessible surface, and the insulation
system is treated as reinforced insulation
29.1.4 Clearances for functional insulation are the largest values determined from: P
- table 16 based on the rated impulse voltage ...... : (see appended table) P
- table F.7a in IEC 60664-1, frequency not exceeding N
30 kHz
- clause 4 of IEC 60664-4, frequency exceeding 30 N
kHz
If values of table 16 are largest, the impulse voltage N
test of clause 14 may be applied instead, unless
the microenvironment is pollution degree 3, or P
the distances can be affected by wear, distortion, P
movement of the parts or during assembly
29.1.5 Appliances having higher working voltages than rated voltage, clearances for basic N
insulation are the largest values determined from:
- table 16 based on the rated impulse voltage ...... : N
- table F.7a in IEC 60664-1, frequency not exceeding N
30 kHz
- clause 4 of IEC 60664-4, frequency exceeding 30 N
kHz
If clearances for basic insulation are selected from N
Table F.7a of IEC 60664-1 or Clause 4 of IEC
60664-4, the clearances of supplementary insulation
are not less than those specified for basic insulation

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 67 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

If clearances for basic insulation are selected from N


Table F.7a of IEC 60664-1, the clearances of
reinforced insulation dimensioned as specified in
Table F.7a are to withstand 160% of the withstand
voltage required for basic insulation
If clearances for basic insulation are selected from N
Clause 4 of IEC 60664-4, the clearances of
reinforced insulation are twice the value required for
basic insulation
29.2.1 Creepage distances of basic insulation not less than (see appended table) P
specified in table 17 .............................................. :
However, if the working voltage is periodic and has a N
frequency exceeding 30 kHz, the creepage
distances are also determined from table 2 of IEC
60664-4, these values being used if exceeding the
values in table 17 .................................................. :
29.2.2 Creepage distances of supplementary insulation at (see appended table) P
least those specified for basic insulation in table 17,
or ........................................................................... :
Table 2 of IEC 60664-4, as applicable .................. : N
29.2.3 Creepage distances of reinforced insulation at least (see appended table) P
double those specified for basic insulation in table
17, or ..................................................................... :
Table 2 of IEC 60664-4, as applicable .................. : N
29.2.4 Creepage distances of functional insulation not less (see appended table) P
than specified in table 18 ...................................... :
However, if the working voltage is periodic and has a N
frequency exceeding 30 kHz, the creepage
distances are also determined from table 2 of IEC
60664-4, these values being used if exceeding the
values in table 18 .................................................. :
29.3 Compliance checked: N
- by an assessment of the thermal quality of the N
material combined with an electric strength test, in
accordance with 29.3.3, and
for accessible parts of reinforced insulation N
consisting of a single layer, by measurement in
accordance with 29.3.4, or
- as specified in subclause 6.3 of IEC 60664-4 for N
insulation that is subjected to any periodic voltage
having a frequency exceeding 30 kHz
29.3.4 Thickness of accessible parts of reinforced N
insulation consisting of a single layer not less than
specified in table 19 .............................................. :

30 RESISTANCE TO HEAT AND FIRE P

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 68 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

30.2 This requirement does not apply to: P


parts having a mass not exceeding 0,5 g, provided N
the cumulative effect is unlikely to propagate flames
that originate inside the appliance by propagating
flames from one part to another, or
30.2.1 Parts of non-metallic material subjected to the P
glow-wire test of IEC 60695-2-11 at 550 C
However, test not carried out if the material is N
classified as having a glow-wire flammability index
according to IEC 60695-2-12 of at least 550 C, or
30.2.2 The glow-wire test is also not carried out on small parts. These parts are to: N
- comprise material having a glow-wire flammability N
index of at least 750 C, or 650 C as appropriate, or
- comply with the needle-flame test of Annex E, or N
- comprise material classified as V-0 or V-1 N
according to IEC 60695-11-10 .............................. :
30.2.3.2 However, the glow-wire test of 750 C or 650 C as appropriate, is not carried out on N
parts of material fulfilling both or either of the following classifications:
- a glow-wire ignition temperature according to IEC N
60695-2-13 of at least:
 775 C, for connections carrying a current N
exceeding 0,2 A during normal operation
 675 C, for other connections N
- a glow-wire flammability index according to IEC N
60695-2-12 of at least:
- 750 C, for connections carrying a current N
exceeding 0,2 A during normal operation
- 650 C, for other connections N
The glow-wire test is also not carried out on small parts. These parts are to: N
- comprise material having a glow-wire ignition N
temperature of at least 775 C or 675 C as
appropriate, or
- comprise material having a glow-wire flammability N
index of at least 750 C or 650 C as appropriate, or
- comply with the needle-flame test of Annex E, or N
- comprise material classified as V-0 or V-1 N
according to IEC 60695-11-10
The consequential needle-flame test of Annex E applied to non-metallic parts that N
encroach within the vertical cylinder placed above the centre of the connection zone
and on top of the non-metallic parts supporting current-carrying connections, and
parts of non-metallic material within a distance of 3 mm of such connections if these
parts are those:

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 69 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

- parts that withstood the glow-wire test of IEC N


60695-2-11 of 750 C or 650 C as appropriate, but
produce a flame that persist longer than 2 s, or
- parts that comprised material having a glow-wire N
flammability index of at least 750 C or 650 C as
appropriate, or
- small parts, that comprised material having a N
glow-wire flammability index of at least 750 C or 650
C as appropriate, or
- small parts for which the needle-flame test of N
Annex E was applied, or
- small parts for which a material classification of V-0 N
or V-1 was applied
However, the consequential needle-flame test is not carried out on non-metallic N
parts, including small parts, within the cylinder that are:
- parts having a glow-wire ignition temperature of at N
least 775 C or 675 C as appropriate, or
- parts comprising material classified as V-0 or V-1 N
according to IEC 60695-11-10, or
- parts shielded by a flame barrier that meets the N
needle-flame test of Annex E or that comprises
material classified as V-0 or V-1 according to IEC
60695-11-10

B ANNEX B (NORMATIVE) N
APPLIANCES POWERED BY RECHARGEABLE BATTERIES
7.1 The positive terminal indicated by symbol IEC N
60417-5005 and the negative terminal by symbol
IEC 60417-5006
7.6 Symbols 60417-5005 and IEC 60417-5006 N

F ANNEX F (NORMATIVE) N
CAPACITORS
3.4.3.2 Table 3 is applicable as described N

G ANNEX G (NORMATIVE) N
SAFETY ISOLATING TRANSFORMERS
29.1, 29.2, The distances specified in items 2a, 2c and 3 in table N
29.3 13 of IEC 61558-1 apply
For insulated winding wires complying with N
subclause 19.12.3 of IEC 61558-1 there are no
requirements for clearances or creepage distances

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 70 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

For windings providing reinforced insulation, the N


distance specified in item 2c of table 13 of IEC
61558-1 is not assessed
For safety isolating transformers subjected to N
periodic voltages with a frequency exceeding 30
kHz, the clearances, creepage distances and solid
insulation values specified in IEC 60664-4 are
applicable, if greater than the values specified in
items 2a, 2c and 3 in table 13 of IEC 61558-1

R ANNEX R (NORMATIVE) N
SOFTWARE EVALUATION
Programmable electronic circuits requiring software N
incorporating measures to control the fault/error
conditions specified in table R.1 or R.2 validated in
accordance with the requirements of this annex
R.1 Programmable electronic circuits using software N
Programmable electronic circuits requiring software N
incorporating measures to control the fault/error
conditions specified in table R.1 or R.2 constructed
so that the software does not impair compliance with
the requirements of this standard
R.2 Requirements for the architecture N
Programmable electronic circuits requiring software N
incorporating measures to control the fault/error
conditions specified in table R.1 or R.2 use
measures to control and avoid software-related
faults/errors in safety-related data and safety-related
segments of the software
R.2.1.1 Programmable electronic circuits requiring software incorporating measures to N
control the fault/error conditions specified in table R.2 have one of the following
structures:
- single channel with periodic self-test and N
monitoring
- dual channel (homogenous) with comparison N
- dual channel (diverse) with comparison N
Programmable electronic circuits requiring software incorporating measures to N
control the fault/error conditions specified in table R.1 have one of the following
structures:
- single channel with functional test N
- single channel with periodic self-test N
- dual channel without comparison N
R.2.2 Measures to control faults/errors N

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 71 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

R.2.2.1 When redundant memory with comparison is N


provided on two areas of the same component, the
data in one area is stored in a different format from
that in the other area
R.2.2.2 Programmable electronic circuits with functions N
requiring software incorporating measures to control
the fault/error conditions specified in table R.2 and
that use dual channel structures with comparison,
have additional fault/error detection means for any
fault/errors not detected by the comparison
R.2.2.3 For programmable electronic circuits with functions N
requiring software incorporating measures to control
the fault/error conditions specified in table R.1 or
R.2, means are provided for the recognition and
control of errors in transmissions to external
safety-related data paths
R.2.2.4 For programmable electronic circuits with functions N
requiring software incorporating measures to control
the fault/error conditions specified in table R.1 or
R.2, the programmable electronic circuits
incorporate measures to address the fault/errors in
safety-related segments and data indicated in table
R.1 and R.2 as appropriate
R.2.2.5 For programmable electronic circuits with functions N
requiring software incorporating measures to control
the fault/error conditions specified in table R.1 or
R.2, detection of a fault/error occur before
compliance with clause 19 is impaired
R.2.2.6 The software is referenced to relevant parts of the N
operating sequence and the associated hardware
functions
R.2.2.7 Labels used for memory locations are unique N
R.2.2.8 The software is protected from user alteration of N
safety-related segments and data
R.2.2.9 Software and safety-related hardware under its N
control is initialized and terminates before
compliance with clause 19 is impaired
R.3 Measures to avoid errors N
R.3.1 General N
For programmable electronic circuits with functions requiring software incorporating N
measures to control the fault/error conditions specified in table R.1 or R.2, the
following measures to avoid systematic fault in the software are applied
Software that incorporates measures used to control N
the fault/error conditions specified in table R.2 is
inherently acceptable for software required to control
the fault/error conditions specified in table R.1
R.3.2 Specification N
R.3.2.1 Software safety requirements: N
Waltek Services (Shenzhen) Co., Ltd.
http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 72 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

The specification of the software safety N


requirements includes the descriptions listed
R.3.2.2 Software architecture N
R.3.2.2.1 The specification of the software architecture N
includes the aspects listed
- techniques and measures to control software
faults/errors (refer to R.2.2);
- interactions between hardware and software;
- partitioning into modules and their allocation to the
specified safety functions;
- hierarchy and call structure of the modules (control
flow);
- interrupt handling;
- data flow and restrictions on data access;
- architecture and storage of data;
- time-based dependencies of sequences and data
R.3.2.2.2 The architecture specification is validated against N
the specification of the software safety requirements
by static analysis
R.3.2.3 Module design and coding N
R.3.2.3.1 Based on the architecture design, software is N
suitably refined into modules
Software module design and coding is implemented N
in a way that is traceable to the software architecture
and requirements
R.3.2.3.2 Software code is structured N
R.3.2.3.3 Coded software is validated against the module N
specification by static analysis
The module specification is validated against the N
architecture specification by static analysis
R.3.3.3 Software validation N
The software is validated with reference to the N
requirements of the software safety requirements
specification
Compliance is checked by simulation of: N
- input signals present during normal operation N
- anticipated occurrences N
- undesired conditions requiring system action N

Deviation Report of IEC 60335-1:2010 from IEC 60335-1:2001+ A1:2004 + A2:2006


5 General conditions for the tests P
Waltek Services (Shenzhen) Co., Ltd.
http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 73 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

5.19 If a component or part of the appliance has both a N


self resetting feature and a non self-resetting feature
and if the non-self-resetting feature is not required in
order to comply with the standard, then appliances
incorporating such a component or part shall be
tested with the non-self-resetting feature rendered
inoperative.

7 MARKING AND INSTRUCTIONS P


7.1 Symbol IEC 60417-5180, for class III appliances, N
unless
the appliance is operated by batteries only N
7.4 Requirement met if frequent changes are not N
required and the rated voltage to which the appliance
is to be adjusted is determined from a wiring diagram
7.6 Correct symbols used P
Symbol for nature of supply placed next to rated P
voltage
Symbol for class II appliances placed unlikely to be N
confused with other marking
Units of physical quantities and their symbols P
according to international standardized system
7.7 Connection diagram fixed to appliances to be N
connected to more than two supply conductors and
appliances for multiple supply, unless
correct mode of connection is obvious N
7.10 This applies also to switches which are part of a N
control
If figures are used, the off position indicated by the N
figure 0
7.12 Details concerning precautions during user P
maintenance
For a part of class III construction supplied from a N
detachable power supply unit, the instructions state
that the appliance is only to be used with the unit
provided
Instructions for class III appliances state that it must N
only be supplied at SELV, unless
it is a battery-operated appliance, the battery being N
charged outside the appliance
7.12.1 Sufficient details for installation supplied P
For an appliance intended to be permanently N
connected to the water mains and not connected by
a hose-set, this is stated

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 74 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

7.12.6 If a non-self-resetting thermal cut-out is required in N


order to comply with the standard then the
instructions for appliances incorporating a
non-self-resetting thermal cut-out that is reset by
disconnection of the supply mains shall contain the
substance of the following:
CAUTION: In order to avoid a hazard due to N
inadvertent resetting of the thermal cut-out,
this appliance must not be supplied through an
external switching device, such as a timer, or
connected to a circuit that is regularly switched on
and off by the utility.

8 PROTECTION AGAINST ACCESS TO LIVE PARTS P


8.2 Test probe B of IEC 61032 is applied to built-in N
appliances and fixed appliances only after
installation.

11 HEATING P
11.8 The temperature rise limit for metal applies to parts P
having a metal coating at least 0,1 mm thick and to
metal parts having a plastic coating less than 0,3 mm
thick.

13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING P


TEMPERATURE
13.2 For class 0, class II and class III appliances, leakage N
current measured by means of the circuit described
in figure 4 of IEC 60990. For other appliances, a low
impedance ammeter may be used.

17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS N


Basic insulation is not short-circuited N

19 ABNORMAL OPERATION P
19.1 Appliances incorporating voltage selector switches N
subjected to the test of 19.15
19.9 Motor-operated and combined appliances for which N
30.2.3 is applicable and that use overload protective
devices relying on electronic circuits to protect the
motor windings, are also subjected to the test
19.11.4.6 Appliances having a rated current exceeding 16 A N
are subjected to the Class 3 voltage dips and
interruptions in accordance with IEC 61000-4-34

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 75 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

19.13 If the appliance contains lids or doors that are controlled by one or more interlocks, N
one of the interlocks may be released provided that:
- the lid or door does not move automatically to an N
open position when the interlock is released, and
- the appliance does not start after the cycle in which N
the interlock was released
19.15 For appliances with a mains voltage selector switch, N
the switch is set to the lowest rated voltage position
and the highest value of rated voltage is applied

20 STABILITY AND MECHANICAL HAZARDS P


20.2 Enclosures that can be opened by overriding an N
interlock are considered to be detachable parts

22 CONSTRUCTION P
22.24 Bare heating elements, other than those in class III N
appliances or class III constructions that do not
contain live parts, shall be supported so that the
heating conductor is unlikely to come into contact
with accessible metal parts if they rupture.
22.25 Appliances shall be constructed so that sagging N
heating conductors cannot come into contact with
accessible metal parts. This requirement does not
apply to class III appliances or class III constructions
that do not contain live parts.
22.33 For class II constructions, conductive liquids that are P
or may become accessible in normal use and
conductive liquids that are in contact with unearthed
accessible metal parts, not in direct contact with
basic or reinforced insulation, unless
the reinforced insulation consists of at least 3 layers N
For class II constructions, conductive liquids which P
are in contact with live parts, not in direct contact with
reinforced insulation, unless
the reinforced insulation consists of at least 3 layers N
An air layer not used as basic or supplementary P
insulation in a double insulation system if likely to be
bridged by leaking liquid
22.35 Insulating material covering metal handles, levers P
and knobs withstand the electric strength test of 16.3
for supplementary insulation
22.42 Resistors checked by the test of 14.1 a) in IEC 60065 N
Capacitors checked by the tests for class Y N
capacitors in IEC 60384-14

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 76 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

22.46 For programmable protective electronic circuits used N


to ensure compliance with the standard, the software
contains measures to control the fault/error
conditions in table R.1
Software that contains measures to control the N
fault/error conditions specified in table R.2 is to be
specified in parts 2 for particular constructions or to
address specific hazards
These requirements are not applicable to software N
used for functional purpose or compliance with
clause 11
23 INTERNAL WIRING P
23.3 Electric strength test of 16.3, 1000 V between live N
parts and accessible metal parts
Not more than 10% of the strands of any conductor N
broken, and
not more than 30% for wiring supplying circuits that N
consume no more than 15W
23.5 Basic insulation electrically equivalent to the basic N
insulation of cords complying with IEC 60227 or IEC
60245, or
23.6 Sleeving used as supplementary insulation on N
internal wiring retained in position by clamping at
both ends, or
be such that it can only be removed by breaking or N
cutting

24 COMPONENTS P
24.1 For components mentioned in 24.1.1 to 24.1.9 no P
additional tests specified in the relevant component
standard are necessary other than those specified in
24.1.1 to 24.1.9
No additional tests specified for nationally P
standardized plugs such as those detailed in IEC/TR
60083 or connectors complying with the standard
sheets of IEC 60320-1 and IEC 60309
24.1.3 If the switch only operates a motor staring relay N
complying with IEC 60730-2-10 with the number of
cycles of a least 10 000 as specified, the complete
switching system need not be tested
24.1.4 The number of cycles for controls operating during N
clause 11 need not be declared, if the appliance
meets the requirements of this standard when they
are short-circuited
24.2 Appliances not fitted with: N

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 77 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

- thermal cut-outs that can be reset by soldering, N


unless
the solder has a melding point of at least 230 ˚C N
24.7 Appliances intended to be permanently connected to N
the water mains shall not be connected by a
detachable hose-set
24.8 Motor running capacitors in appliances for which N
30.2.3 is applicable and that are permanently
connected in series with a motor winding, not
causing a hazard in event of a failure
One or more of the following conditions are to be met: N
- the capacitors are of class P2 according to IEC N
60252-1
- the capacitors are housed within a metallic or N
ceramic enclosure
- the distance of separation of the outer surface to N
adjacent non-metallic parts exceeds 50 mm
- adjacent non-metallic parts within 50 mm withstand N
the needle-flame test of Annex E
- adjacent non-metallic parts within 50 mm classified N
as at least V-1 according to IEC 60695-11-10

25 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS P


25.3 Appliance intended to be permanently connected to fixed wiring provided with one of N
the following means for connection to the supply mains:
- a set of terminals allowing the connection of a N
flexible cord
- a fitted supply cord N
- a set of supply leads accommodated in a suitable N
compartment
Appliances intended to be permanently connected to N
fixed wiring that are provided with
a set of terminals allowing the connection of cables N
of fixed wiring having the nominal cross-sectional
areas specified in 26.6, or
a set of terminals and cable entries, conduit entries, N
knock-outs or glands, which allow the connection of
the appropriate types of cable or conduit,
shall allow the connection of the supply conductors N
after the appliance has been fixed to its support.

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 78 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

If a fixed appliance is constructed so that parts can N


be removed to facilitate easy installation, this
requirement is considered to be met if it is possible to
connect the fixed wiring without difficulty after a part
of the appliance has been fixed to its support. In this
case, removable parts are to be constructed for ease
of reassembly without risk of incorrect assembly or
damage to the wiring or terminals.
25.5 Method for assembling the supply cord to the appliance: N
For multi-phase appliances supplied with a supply N
cord and that are intended to be permanently
connected to fixed wiring, the supply cord is
assembled to the appliance by type Y attachment
25.7 Supply cords, other than for class III appliances, being one of the following types: P
Supply cords for class III appliances adequately N
insulated
A voltage of 500 V is applied for 2 min between the P
conductor and metal foil wrapped around the
insulation, the insulation being at the temperature
measured during the test of Clause 11. There shall
be no breakdown during this test.
25.13 If unsheathed supply cord, a similar additional N
bushing or lining is required, unless the appliance is
class 0, or N
a class III appliance not containing live parts N
25.22 Appliance inlets: N
- live parts not accessible during insertion or removal N
Requirement not applicable to appliance inlets N
complying with IEC 60320-1

26 TERMINALS FOR EXTERNAL CONDUCTORS P


26.1 Terminals only accessible after removal of a P
non-detachable cover, except
for class III appliances that do not contain live parts N
26.2 Change ―connection to fixed wiring‖ to ―connection of N
cables of fixed wiring‖
26.3 Change ―connection to fixed wiring‖ to ―connection of N
cables of fixed wiring‖
26.4 Change ―connection to fixed wiring‖ to ―connection of N
cables of fixed wiring‖
26.6 Change ―connection to fixed wiring‖ to ―connection of N
cables of fixed wiring‖

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 79 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

28 SCREWS AND CONNECTIONS P


28.2 This requirement does not apply to electrical connections in circuits of appliances for N
which:
 30.2.2 is applicable and that carry a current N
not exceeding 0,5 A
 30.2.3 is applicable and that carry a current N
not exceeding 0,2 A

29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION P


For type 2 protection, the spacing between the N
conductors before the protection is applied is not
less than the values specified in Table 1 of IEC
60664-3
These values apply to functional, basic, P
supplementary and reinforced insulation .............. :
29.1.3 For double insulation, with no intermediate P
conductive part between basic and supplementary
insulation, clearances are measured between live
parts and the accessible surface, and the insulation
system is treated as reinforced insulation
29.1.4 Clearances for functional insulation are the largest values determined from: P
- table 16 based on the rated impulse voltage ...... : (see appended table) P
- table F.7a in IEC 60664-1, frequency not exceeding N
30 kHz
- clause 4 of IEC 60664-4, frequency exceeding 30 N
kHz
If values of table 16 are largest, the impulse voltage N
test of clause 14 may be applied instead, unless
the microenvironment is pollution degree 3, or P
the distances can be affected by wear, distortion, P
movement of the parts or during assembly
29.1.5 Appliances having higher working voltages than rated voltage, clearances for basic N
insulation are the largest values determined from:
- table 16 based on the rated impulse voltage ...... : N
- table F.7a in IEC 60664-1, frequency not exceeding N
30 kHz
- clause 4 of IEC 60664-4, frequency exceeding 30 N
kHz
If clearances for basic insulation are selected from N
Table F.7a of IEC 60664-1 or Clause 4 of IEC
60664-4, the clearances of supplementary insulation
are not less than those specified for basic insulation

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 80 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

If clearances for basic insulation are selected from N


Table F.7a of IEC 60664-1, the clearances of
reinforced insulation dimensioned as specified in
Table F.7a are to withstand 160% of the withstand
voltage required for basic insulation
If clearances for basic insulation are selected from N
Clause 4 of IEC 60664-4, the clearances of
reinforced insulation are twice the value required for
basic insulation
29.2.1 Creepage distances of basic insulation not less than (see appended table) P
specified in table 17 .............................................. :
However, if the working voltage is periodic and has a N
frequency exceeding 30 kHz, the creepage
distances are also determined from table 2 of IEC
60664-4, these values being used if exceeding the
values in table 17 .................................................. :
29.2.2 Creepage distances of supplementary insulation at (see appended table) P
least those specified for basic insulation in table 17,
or ........................................................................... :
Table 2 of IEC 60664-4, as applicable .................. : N
29.2.3 Creepage distances of reinforced insulation at least (see appended table) P
double those specified for basic insulation in table
17, or ..................................................................... :
Table 2 of IEC 60664-4, as applicable .................. : N
29.2.4 Creepage distances of functional insulation not less (see appended table) P
than specified in table 18 ...................................... :
However, if the working voltage is periodic and has a N
frequency exceeding 30 kHz, the creepage
distances are also determined from table 2 of IEC
60664-4, these values being used if exceeding the
values in table 18 .................................................. :
29.3 Compliance checked: N
- by an assessment of the thermal quality of the N
material combined with an electric strength test, in
accordance with 29.3.3, and
for accessible parts of reinforced insulation N
consisting of a single layer, by measurement in
accordance with 29.3.4, or
- as specified in subclause 6.3 of IEC 60664-4 for N
insulation that is subjected to any periodic voltage
having a frequency exceeding 30 kHz
29.3.4 Thickness of accessible parts of reinforced N
insulation consisting of a single layer not less than
specified in table 19 .............................................. :

30 RESISTANCE TO HEAT AND FIRE P

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 81 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

30.2 This requirement does not apply to: P


parts having a mass not exceeding 0,5 g, provided N
the cumulative effect is unlikely to propagate flames
that originate inside the appliance by propagating
flames from one part to another, or
30.2.1 Parts of non-metallic material subjected to the P
glow-wire test of IEC 60695-2-11 at 550 C
However, test not carried out if the material is N
classified as having a glow-wire flammability index
according to IEC 60695-2-12 of at least 550 C, or
30.2.2 The glow-wire test is also not carried out on small parts. These parts are to: N
- comprise material having a glow-wire flammability N
index of at least 750 C, or 650 C as appropriate, or
- comply with the needle-flame test of Annex E, or N
- comprise material classified as V-0 or V-1 N
according to IEC 60695-11-10 .............................. :
30.2.3.2 However, the glow-wire test of 750 C or 650 C as appropriate, is not carried out on N
parts of material fulfilling both or either of the following classifications:
- a glow-wire ignition temperature according to IEC N
60695-2-13 of at least:
 775 C, for connections carrying a current N
exceeding 0,2 A during normal operation
 675 C, for other connections N
- a glow-wire flammability index according to IEC N
60695-2-12 of at least:
- 750 C, for connections carrying a current N
exceeding 0,2 A during normal operation
- 650 C, for other connections N
The glow-wire test is also not carried out on small parts. These parts are to: N
- comprise material having a glow-wire ignition N
temperature of at least 775 C or 675 C as
appropriate, or
- comprise material having a glow-wire flammability N
index of at least 750 C or 650 C as appropriate, or
- comply with the needle-flame test of Annex E, or N
- comprise material classified as V-0 or V-1 N
according to IEC 60695-11-10
The consequential needle-flame test of Annex E applied to non-metallic parts that N
encroach within the vertical cylinder placed above the centre of the connection zone
and on top of the non-metallic parts supporting current-carrying connections, and
parts of non-metallic material within a distance of 3 mm of such connections if these
parts are those:

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 82 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

- parts that withstood the glow-wire test of IEC N


60695-2-11 of 750 C or 650 C as appropriate, but
produce a flame that persist longer than 2 s, or
- parts that comprised material having a glow-wire N
flammability index of at least 750 C or 650 C as
appropriate, or
- small parts, that comprised material having a N
glow-wire flammability index of at least 750 C or 650
C as appropriate, or
- small parts for which the needle-flame test of N
Annex E was applied, or
- small parts for which a material classification of V-0 N
or V-1 was applied
However, the consequential needle-flame test is not carried out on non-metallic N
parts, including small parts, within the cylinder that are:
- parts having a glow-wire ignition temperature of at N
least 775 C or 675 C as appropriate, or
- parts comprising material classified as V-0 or V-1 N
according to IEC 60695-11-10, or
- parts shielded by a flame barrier that meets the N
needle-flame test of Annex E or that comprises
material classified as V-0 or V-1 according to IEC
60695-11-10

B ANNEX B (NORMATIVE) N
APPLIANCES POWERED BY RECHARGEABLE BATTERIES
7.1 The positive terminal indicated by symbol IEC N
60417-5005 and the negative terminal by symbol
IEC 60417-5006
7.6 Symbols 60417-5005 and IEC 60417-5006 N

F ANNEX F (NORMATIVE) N
CAPACITORS
3.4.3.2 Table 3 is applicable as described N

G ANNEX G (NORMATIVE) N
SAFETY ISOLATING TRANSFORMERS
29.1, 29.2, The distances specified in items 2a, 2c and 3 in table N
29.3 13 of IEC 61558-1 apply
For insulated winding wires complying with N
subclause 19.12.3 of IEC 61558-1 there are no
requirements for clearances or creepage distances

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 83 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

For windings providing reinforced insulation, the N


distance specified in item 2c of table 13 of IEC
61558-1 is not assessed
For safety isolating transformers subjected to N
periodic voltages with a frequency exceeding 30
kHz, the clearances, creepage distances and solid
insulation values specified in IEC 60664-4 are
applicable, if greater than the values specified in
items 2a, 2c and 3 in table 13 of IEC 61558-1

R ANNEX R (NORMATIVE) N
SOFTWARE EVALUATION
Programmable electronic circuits requiring software N
incorporating measures to control the fault/error
conditions specified in table R.1 or R.2 validated in
accordance with the requirements of this annex
R.1 Programmable electronic circuits using software N
Programmable electronic circuits requiring software N
incorporating measures to control the fault/error
conditions specified in table R.1 or R.2 constructed
so that the software does not impair compliance with
the requirements of this standard
R.2 Requirements for the architecture N
Programmable electronic circuits requiring software N
incorporating measures to control the fault/error
conditions specified in table R.1 or R.2 use
measures to control and avoid software-related
faults/errors in safety-related data and safety-related
segments of the software
R.2.1.1 Programmable electronic circuits requiring software incorporating measures to N
control the fault/error conditions specified in table R.2 have one of the following
structures:
- single channel with periodic self-test and N
monitoring
- dual channel (homogenous) with comparison N
- dual channel (diverse) with comparison N
Programmable electronic circuits requiring software incorporating measures to N
control the fault/error conditions specified in table R.1 have one of the following
structures:
- single channel with functional test N
- single channel with periodic self-test N
- dual channel without comparison N
R.2.2 Measures to control faults/errors N

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 84 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

R.2.2.1 When redundant memory with comparison is N


provided on two areas of the same component, the
data in one area is stored in a different format from
that in the other area
R.2.2.2 Programmable electronic circuits with functions N
requiring software incorporating measures to control
the fault/error conditions specified in table R.2 and
that use dual channel structures with comparison,
have additional fault/error detection means for any
fault/errors not detected by the comparison
R.2.2.3 For programmable electronic circuits with functions N
requiring software incorporating measures to control
the fault/error conditions specified in table R.1 or
R.2, means are provided for the recognition and
control of errors in transmissions to external
safety-related data paths
R.2.2.4 For programmable electronic circuits with functions N
requiring software incorporating measures to control
the fault/error conditions specified in table R.1 or
R.2, the programmable electronic circuits
incorporate measures to address the fault/errors in
safety-related segments and data indicated in table
R.1 and R.2 as appropriate
R.2.2.5 For programmable electronic circuits with functions N
requiring software incorporating measures to control
the fault/error conditions specified in table R.1 or
R.2, detection of a fault/error occur before
compliance with clause 19 is impaired
R.2.2.6 The software is referenced to relevant parts of the N
operating sequence and the associated hardware
functions
R.2.2.7 Labels used for memory locations are unique N
R.2.2.8 The software is protected from user alteration of N
safety-related segments and data
R.2.2.9 Software and safety-related hardware under its N
control is initialized and terminates before
compliance with clause 19 is impaired
R.3 Measures to avoid errors N
R.3.1 General N
For programmable electronic circuits with functions requiring software incorporating N
measures to control the fault/error conditions specified in table R.1 or R.2, the
following measures to avoid systematic fault in the software are applied
Software that incorporates measures used to control N
the fault/error conditions specified in table R.2 is
inherently acceptable for software required to control
the fault/error conditions specified in table R.1
R.3.2 Specification N
R.3.2.1 Software safety requirements: N
Waltek Services (Shenzhen) Co., Ltd.
http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 85 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

The specification of the software safety N


requirements includes the descriptions listed
R.3.2.2 Software architecture N
R.3.2.2.1 The specification of the software architecture N
includes the aspects listed
- techniques and measures to control software
faults/errors (refer to R.2.2);
- interactions between hardware and software;
- partitioning into modules and their allocation to the
specified safety functions;
- hierarchy and call structure of the modules (control
flow);
- interrupt handling;
- data flow and restrictions on data access;
- architecture and storage of data;
- time-based dependencies of sequences and data
R.3.2.2.2 The architecture specification is validated against N
the specification of the software safety requirements
by static analysis
R.3.2.3 Module design and coding N
R.3.2.3.1 Based on the architecture design, software is N
suitably refined into modules
Software module design and coding is implemented N
in a way that is traceable to the software architecture
and requirements
R.3.2.3.2 Software code is structured N
R.3.2.3.3 Coded software is validated against the module N
specification by static analysis
The module specification is validated against the N
architecture specification by static analysis
R.3.3.3 Software validation N
The software is validated with reference to the N
requirements of the software safety requirements
specification
Compliance is checked by simulation of: N
- input signals present during normal operation N
- anticipated occurrences N
- undesired conditions requiring system action N

th
Group/CENELEC Common Differences to IEC 60335-1:2010 (5 Edition)

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 86 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

6.1 Delete ―class 0‖ and ―class 01‖ N


7.10 Add: P
Devices used to start/stop operational functions of P
the appliance, if any, shall be distinguished from
other manual devices by means of shape, or size, or
surface texture, or position, etc.
A tactile feedback or P
An audible and visual feedback P
NOTE Z1 The sound of the motor or sound of an P
actuator switching ON/OFF is regarded as audible
feedback. The stopping of the typical function
(e.g.stopping of the vibration on the body of the
appliance or of a part of it) is regarded as tactile
means.
NOTE Z2 Devices used to start/stop operational P
functions mean devices that are operated by the
user to start/stop the intended function of the
appliance.
A selector switch with an off-position clearly P
identifiable is allowed.
An ON/OFF switch, if any, is considered a suitable P
device to stop operational functions. A plug is not
considered a suitable device to stop operational
functions, as it can be difficult to be reached by
vulnerable persons.
7.12 The instructions shall include the substance of the P
following:
This appliance can be used by children aged from 8 P
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision
or instruction concerning use of the appliance in a
safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children
without supervision.
7.12.Z1 The specific instructions related to the safe operation P
of this appliance (as given in 7.12 of this standard)
shall be collated together in the front section of the
user instructions. The height of the characters,
measured on the capital letters, shall be at least
3mm
These instructions shall also be available in an P
alternative format, e.g. on a website
7.14 Added: P
For the evaluation of legibility and clarity of safety P
warnings guidance can be found in IEC 62079

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 87 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

rd
8.1.1 Replace the 3 paragraph by the following: P
Test probe B and probe 18 of EN 61032 are applied P
with a force not exceeding 1N,the appliance being in
every possible position……
8.2 Replace ―test probe B of EN 61032‖ by ―test probe of P
EN 61032‖
Replace ―test probe B of EN 61032‖ by ―test probe B P
and probe 18 of EN 61032 are‖
11.8 Delete the sentence ‖The temperature rise of P
the…… ― of the first paragraph.
15.1.2 Appliances with an automatic cord reel are tested N
with the cord in the most unfavourable position in
such a way that the reeling of the wet cord may affect
electrical insulation during operation. The cord shall
not be dried before reeling
20 Replace Note 1 by the following requirement: N
For appliances having dangerous movable parts,
due to their main function, e.g. the needle of a
sewing machine, tools of kitchen machines of the
blade of an electrical knife, full protection is not
possible for performing their intended use.
st
20.2 Replaced the 1 paragraph of compliance by: N
-a test probe that is similar to test probe B of EN
61032 but having a circular stop face with a diameter
of 50 mm, instead of the non-circular face, applied
with a force of 5N with the accessories and
detachable cover removed and
- test probe 18 of EN 61032, applied with a force of
2.5N on the appliance in a fully assembled situation.
24.1 Plugs and socket-outlets and other connecting N
devices of interconnection cords shall not be
interchangeable with plugs and socket-outlets listed
in IEC/TR 60083 or IEC 6906-1 or with connectors
and appliance inlets complying with the standard
sheets of IEC 60320-1, if direct supply to these parts
from the supply mains could give rise to a hazard
24.1.3 Add NOTE Z1 For this test a thermostat or timer that N
is operating the relay or contactor is considered to be
a switch
24.1.7 If the remote operation of the appliance is via a N
telecommunication network, the relevant standard
for the telecommunication interface circuitry in the
appliance is EN 41003.
24.Z1 For motor running capacitors (IEC 60252-1 type P2) N
with a metallic enclosure having an overpressure
fuse the flame testing of internal plastic parts
supporting current carrying connections as required
in 30.2.2 and 30.2.3.1 is not necessary.
Waltek Services (Shenzhen) Co., Ltd.
http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 88 of 97

IEC 60335-2-35
Clause Requirement - Test Result - Remark Verdict

25.6 Add N
Supply cords of single-phase portable appliances
having a rated current not exceeding 16A shall be
fitted with a plug complying with the following
standard sheets of IEC/TR60083
26 Add after the second sentence in the first paragraph: P
Conductors connected by soldering are not P
considered to be positioned or fixed so that reliance
is not placed upon the soldering alone to maintain
them in position unless they are held in place near
the terminals independently of the solder.
29 Modification: N
Replace NOTE 5 by:
Attention is drawn on the fact that for appliances
intended for use at altitudes exceeding 2000 m, the
altitude correction factors, relevant to the intended
altitude, for clearances specified in Table A.2 of EN
60664-1:2007 may need to be taken into account.
29.3.Z1 Appliance shall be constructed so that if there is a N
possibility of damaging the insulation during
installation, the insulation shall withstand the scratch
and penetration test of 21.2.
Annex ZB Deleted 7.1 and 29.3 N
Annex ZF Table ZF.1 add EN 60335-2-97, drives for rolling N
shutters, awnings, blinds and similar equipment
Annex ZG Add the following: N
7.12.ZG The instructions for appliances incorporating UVC N
emitters shall include the substance of the following:
WARNING-This appliance contains a UV emitter. Do N
not stare at the light source.
32 Add the following: N
For appliances incorporating UV emitters the N
manufacturer’s shall deliver a declaration providing
evidence that the plastic material exposed to the
radiation is UV resistant
NOTE Examples of appliances that may incorporate N
UVC emitters are range hoods, air cleaners and
finger nail hardeners

ANNEX EMF P
The test product also complies with the requirements of EN62233:2008 P
Limit………………100% Max: 1.877% P

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 89 of 97

IEC 60335-2-35

10.1 TABLE: Power input deviation P


Input deviation of/at: P rated (W) P measured dP Required dP Remark
(W)
KUL59-813/
230V, 50Hz 8500 8440 -0.7% +5%, -10% --
85
KUL59-813/
230V, 60Hz 8500 8432 -0.8% +5%, -10% --
85

10.2 TABLE: Current deviation N


Current deviation of/at: I rated (A) I measured (A) dI Required dI Remark

11.8 TABLE: Heating test, thermocouples P


Power input(W) .......................................................: 10643.5W
Test voltage (V) ........................................................: 266.5V 
Ambient (C) .............................................................: 21.5 
Thermocouple locations dT (K) Max. dT (K)
Power cord junction point 40.5 50
Cord clamp 37.3 Cl.30
Non self-resetting thermal cut-out 27.0 Ref.
Self-resetting thermal cut-out 27.4 Ref.
Terminal connector 51.3 Cl.30
Primary winding of transformer 36.6 85
Secondary winding of transformer 32.0 85
Transformer lead wire 24.8 T105-25=85
PCB surface 50.8 Cl.30
Relay 43.2 T85-25=60
Heater lead wire 35.9 T200-25=175
Control PCB lead wire 16.6 T80-25=55
Flow switch 8.4 Ref.
Water outlet sensor 21.7 Ref.
Thermal cut-out lead wire (near heater) 32.2 T200-25=175
Plastic enclosure (inside, near heater) 16.6 Cl.30
Switch button 4.5 60
Test corner 13.4 65
Inlet water temperature 0.3 Ref.

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 90 of 97

IEC 60335-2-35

Outlet water temperature 34.9 Ref.

13.2 TABLE: Leakage current P


Heating appliances: 1.15 x rated input...................: 10643.5W 
Motor-operated and combined appliances: -- 
1.06 x rated voltage ................................................:
Leakage current between I (mA) Max. allowed I (mA)
Live part and Plastic enclosure/ Switch knob 0.048 0.35 peak
Live part and Earthing part 0.137 0.75x8.5

13.3 TABLE: Electric strength P


Test voltage applied between: Voltage (V) Breakdown
(Yes/No)
Live part and Plastic enclosure/ Switch knob 3000 No
Live part and Earthing part 1000 No

14 TABLE: Transient overvoltages N


Clearance between: Cl (mm) Required Cl Rated impulse Impulse test Flashover
(mm) voltage (V) voltage (V) (Yes/No)

16.2 TABLE: Leakage current P


Single phase appliances: 1.06 x rated voltage ......: 1.06X 240=254.4V 
Three phase appliances 1.06 x rated voltage -- 
divided by 3:..........................................................:
Leakage current between I (mA) Max. allowed I (mA)
Live part and Plastic enclosure/ Switch knob 0.059 0.25
Live part and Earthing part 0.189 3.5

16.3 TABLE: Electric strength P


Test voltage applied between: Voltage (V) Breakdown
(Yes/No)
Live part and Plastic enclosure/ Switch knob 3000 No
Live part and Earthing part 1250 No

17 TABLE: Overload protection, temperature rise P


Temperature rise of part/at: dT (K) Max. dT (K)
Primary winding of transformer 132.1 225-25=200
Secondary winding of transformer 109.4 225-25=200
Transformer lead wire 76.0 Ref.

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 91 of 97

IEC 60335-2-35

Temperature of winding R1 (Ω) R2 (Ω) T (C) Max. T (C) Max. T (°C)


Primary winding of transformer 0.9 1.41 167.8 225 130
Secondary winding of transformer 2.4 3.5 140.3 225 130

19.7 TABLE: Abnormal operation, locked rotor/moving parts N


Test voltage (V) ........................................................: 
Ambient, t1 (C) .........................................................: 
Ambient, t2 (C) .........................................................: 
Temperature of winding R1 (Ω) R2 (Ω) T (C) Max. T (C) Max. T (°C)

19.13 TABLE: Abnormal operation, temperature rises P


Thermocouple locations dT (K) Max. dT (K)
Cl.19.4 Cl.19.5
Power cord junction point 41.4 41.6 150
Cord clamp 39.6 39.9 Cl.30
Primary winding of transformer 36.7 36.5 Ref.
Secondary winding of transformer 32.3 32.0 Ref.
Plastic enclosure (inside, near heater) 15.4 15.6 Cl.30
Test corner 13.4 11.3 150

24.1 TABLE: Components P


Object / part No. Manufacturer/ Type / model Technical data Standard Mark(s) of
trademark conformity
Guangdong Rifeng EN 50363-1:2005 EC.1282.OB
2
Power Cord Electrical Cable H07RN-F 3G6mm EN 50395:2005 130328.GRE
Co., Ltd. EN 50396:2006 0464
Zheng Yu Electric
2 VDE
Alternative Appliance Fittings H07RN-F 3G6mm EN 60227
40016693
(Kunshan) Co., Ltd.
2 VDE or other
Alternative Various H07RN-F 3G6mm EN 60227
EU approved
Thermal cut-out Changshu Mingjia
250VAC, 10A,
for relay Electronic EN 60730-1 VDE
KSD301 Tf:65℃, 10E4,
(self-resetting ) Equipment co., EN 60730-2-9 40006355
Tmax:210
LTD
Foshan Kehua
250VAC, 10A,
Electrical TUV
Alternative KSD301 T180, Tf:60℃, EN60730
Appliance CO., R50209508
10E4
LTD
Waltek Services (Shenzhen) Co., Ltd.
http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 92 of 97

IEC 60335-2-35

Foshan
250VAC, 10A,
Lianhehuilong VDE
Alternative KSD301 T180, Tf:60℃, EN60730
Electrical 40034938
10E4
Appliance Co., Ltd
250VAC, 40A, Tf:
Thermal
Therm-O-Disc 85℃,T120, EN 60730-1 VDE
cut-out(non-self- 66T
Europe B.V. 30cycles, grow EN 60730-2-9 40012575
resetting )
wire: 850℃
EN 61810-5:1998
Song Chuan 855AWP-1A- 250VAC, 30A, TUV R
Relay EN 61810-1:1998
Precision Co., Ltd. C2 T85, 10E4 50057260
EN 60255-23:1996
Guangzhou
Heating element Shichao Special 220-240VAC,
KUL812/813/8 EN 60335-1 Tested with
for model Ceramics 8500W, silicon
18 EN 60335-2-35 appliance
KUL59-813/85 Manufacture Co., nitride
LTD
Guangzhou
Heating element Shichao Special 220-240VAC,
KUL812/813/8 EN 60335-1 Tested with
for model Ceramics 8000W, silicon
18 EN 60335-2-35 appliance
KUL59-813/80 Manufacture Co., nitride
LTD
Guangzhou
Heating element Shichao Special 220-240VAC,
KUL812/813/8 EN 60335-1 Tested with
for model Ceramics 7500W, silicon
18 EN 60335-2-35 appliance
KUL59-813/75 Manufacture Co., nitride
LTD
Guangzhou
Heating element Shichao Special 220-240VAC,
KUL812/813/8 EN 60335-1 Tested with
for model Ceramics 6600W, silicon
18 EN 60335-2-35 appliance
KUL59-813/66 Manufacture Co., nitride
LTD
UL E228872
Degson Electronics EN 60335-1
Terminal block DG 45C-02T 300VAC, 25A Tested with
Co.,Ltd EN 60335-2-35
appliance
GUANGZHOU Min. thickness:
Plastic EN 60335-1 Tested with
YOU XIN MOULD ABS 2,0
enclosure EN 60335-2-35 appliance
CO.,LTD mm
Chuandong
Water flow 24VDC, 0.05A, EN 60335-1 Tested with
Magnetic CPS-3150
switch 10E4, EN 60335-2-35 appliance
Electronic Co.,Ltd.
Input:
Guangzhou
220V-240V,
Haizhu District EN 60335-1 Tested with
Transformer EI-48x20 50Hz. Output:
Jiangnan Radio EN 60335-2-35 appliance
13V, 0.42A, class
component factory
130
GUANGZHOU
14 AWG
FENG TAI VDE
Internal wire 3135 -16AWG, --
ELECTRONIC CO 40013790
200℃, 600 V
LTD
14 AWG
VDE or UL
Alternative Various 3135 -16AWG, --
approved
200℃, 600 V

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 93 of 97

IEC 60335-2-35

GUANGZHOU
ZHIHE 600V, T105, UL
Internal wire ELECTRONIC CO 1015 --
8-16AWG (E251728)
LTD
600V, T105,
Alternative Various 1015 -- UL approved
8-16AWG
300V, T80,
Internal wire Various 2468 -- UL approved
14-24AWG

KINGBOARD UL E123995
KB2150, V-0, Thickness: EN 60335-1
PCB LAMINATES Tested with
KB5150 1.6 mm EN 60335-2-35
HOLDINGS LTD appliance
SHENZHEN UL E226252
BOMIN XING V-0, Thickness: EN 60335-1
Alternative BMX-01 Tested with
ELECTRONIC CO 1.6 mm EN 60335-2-35
appliance
LTD
SHENZHEN UL E226252
BOMIN XING V-0, Thickness: EN 60335-1
Alternative BMX-01 Tested with
ELECTRONIC CO 1.6 mm EN 60335-2-35
appliance
LTD

28.1 TABLE: Threaded part torque test P


Threaded part identification Diameter of thread Column number Applied torque ( Nm )
(mm) (I, II, or III)
Screws for earth 4.91 II 2.0
Screw for enclosure 3.64 II 1.2

29.1 TABLE: Clearances P


Overvoltage category ... : II 
Type of insulation:
Rated impulse Min. cl Basic Functional Supplementary Reinforced Verdict / Remark
voltage (V): (mm)
330 0,5* -- -- -- -- N
500 0,5* -- -- -- -- N
800 0,5* -- -- -- -- N
1 500 0,5*/** -- -- -- -- N
2 500 1,5** >1.5 >1.5 >1.5 -- P
4 000 3,0** -- -- -- >3.0 P
6 000 5,5** -- -- -- -- N
8 000 8,0** -- -- -- -- N
10 000 11,0** -- -- -- -- N

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 94 of 97

IEC 60335-2-35

*) The value is increased to 0,8mm for pollution degree 3


*) If the construction is affected by wear, distortion, movement of the parts or during assembly, the value is
increased by 0,5 mm

29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation P


Working voltage Creepage distance
(V) (mm)
Pollution degree
1 2 3 Type of insulation
Material group Material group
) ) )
I II IIIa/IIIb I II IIIa/IIIb B* S* R* Verdict
50 0,2 0,6 0,9 1,2 1,5 1,7 1,9   N
50 0,2 0,6 0,9 1,2 1,5 1,7 1,9   N
50 0,4 1,2 1,8 2,4 3,0 3,4 3,8   N
50 and 125 0,3 0,8 1,1 1,5 1,9 2,1 2,4   N
50 and 125 0,3 0,8 1,1 1,5 1,9 2,1 2,4   N
50 and 125 0,6 1,6 2,2 3,0 3,8 4,2 4,8   N
125 and 250 0,6 1,3 1,8 2,5 3,2 3,6 4,0 >4.0   P
125 and 250 0,6 1,3 1,8 2,5 3,2 3,6 4,0  >4.0  P
125 and 250 1,2 2,6 3,6 5,0 6,4 7,2 8,0   >8.0 P
250 and 400 1,0 2,0 2,8 4,0 5,0 5,6 6,3   N
250 and 400 1,0 2,0 2,8 4,0 5,0 5,6 6,3   N
250 and 400 2,0 4,0 5,6 8,0 10,0 11,2 12,6   N
400 and 500 1,3 2,5 3,6 5,0 6,3 7,1 8,0   N
400 and 500 1,3 2,5 3,6 5,0 6,3 7,1 8,0   N
400 and 500 2,6 5,0 7,2 10,0 12,6 14,2 16,0   N
500 and 800 1,8 3,2 4,5 6,3 8,0 9,0 10,0   N
500 and 800 1,8 3,2 4,5 6,3 8,0 9,0 10,0   N
500 and 800 3,6 6,4 9,0 12,6 16,0 18,0 20,0   N
800 and 1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5   N
800 and 1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5   N
800 and 1000 4,8 8,0 11,2 16,0 20,0 22,0 25,0   N
1000 and 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0   N
1000 and 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0   N
1000 and 1250 6,4 10,0 14,2 20,0 25,0 28,0 32,0   N
1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0   N
1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0   N

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 95 of 97

IEC 60335-2-35

1250 and 1600 8,4 12,6 18,0 25,0 32,0 36,0 40,0   N
1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0   N
1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0   N
1600 and 2000 11,2 16,0 22,0 32,0 40,0 44,0 50,0   N
2000 and 2500 7,5 10,0 14,0 20,0 25, 0 28,0 32,0   N
2000 and 2500 7,5 10,0 14,0 20,0 25, 0 28,0 32,0   N
2000 and 2500 15,0 20,0 28,0 40,0 50,0 56,0 64,0   N
2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0   N
2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0   N
>2500 and 3200 20,0 25,0 36,0 50,0 64,0 72,0 80,0   N
3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0   N
3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0   N
3200 and 4000 25,0 32,0 44,0 64,0 80,0 90,0 100,0   N
4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0   N
4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0   N
4000 and 5000 32,0 40,0 56,0 80,0 100,0 112,0 126,0   N
5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0   N
5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0   N
5000 and 6300 40,0 50,0 72,0 100,0 126,0 142,0 160,0   N
6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0   N
6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0   N
6300 and 8000 50,0 64,0 90,0 126,0 160,0 180,0 200,0   N
8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0   N
8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0   N
8000 and 10000 64,0 80,0 112,0 160,0 200,0 220,0 250,0   N
10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0   N
10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0   N
10000 and 12500 80,0 100,0 142,0 200,0 250,0 280,0 320,0   N
)
* , B=Basic, S=Supplementary and R=Reinforced

29.2 TABLE: Creepage distances, functional insulation P


Working voltage Creepage distance
(V) (mm)
Pollution degree
1 2 3
Material group Material group

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 96 of 97

IEC 60335-2-35

I II IIIa/IIIb I II IIIa/IIIb Verdict / Remark


50 0,2 0,6 0,8 1,1 1,4 1,6 1,8 N
50 and 125 0,3 0,7 1,0 1,4 1,8 2,0 2,2 N
125 and 250 0,4 1,0 1,4 2,0 2,5 2,8 3,2 P
250 and 400 0,8 1,6 2,2 3,2 4,0 4,5 5,0 N
400 and 500 1,0 2,0 2,8 4,0 5,0 5,6 6,3 N
500 and 800 1,8 3,2 4,5 6,3 8,0 9,0 10,0 N
800 and 1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5 N
1000 and 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0 N
1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 N
1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0 N
2000 and 2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0 N
2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0 N
3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0 N
4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0 N
5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0 N
6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0 N
8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0 N
10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0 N

30.1 TABLE: Ball pressure P


Impression diameter Allowed impression
Part Test temperature (C)
(mm) diameter (mm)
Cord clamp 78 0.7 2.0
Plastic enclosure 75 0.7 2.0
Transformer bobbin 125 1.2 2.0
PCB material 125 0.6 2.0
Terminal connector 125 1.1 2.0

30.2 TABLE: Glow-wire test P


Ignition of Ignition of
Test temp.
Part test sample test tissue ti (s) te (s) hf (mm) verdict
(C)
(Y/N) paper (Y/N)
Cord clamp 550 N N -- -- -- P
Transformer bobbin 850 Y N 0 20 30 P

750 N N -- -- -- P

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Reference No.: WT12128113-D-F-L Page 97 of 97

IEC 60335-2-35

PCB material 850 N N -- -- -- P

750 N N -- -- -- P
Relay 850 Y N 0 30 30 P

750 N N -- -- -- P
Terminal connector 850 Y N 0 32 40 P

750 N N -- -- -- P
Non self-resting 850 Y N 5 35 30 P
thermal cut-out
750 N N -- -- -- P
Plastic enclosure 550 N N -- -- -- P
Remark:
Ti = the time between glow wire touched the material and the material ignited
Te = the time between glow wire touched the material and the flame extinguished

30.2-2 TABLE: Needle flame test P


Part Name Application Ignition of tb Ignition of Remark ** Result
Time sample*? wrapping tissue (P/F)
Yes / No Yes / No
PCB material 30s No 0 No -- P

Remark: tb – Duration of burning.


The duration of burning (tb) shall not exceed 30 s. However, for printed circuit boards, it shall not exceed 15s.

=================== End of Test Report ===================

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Page 1 of 13
Photo Documentation
Reference No.: WT12128113-D-F-L

Model: KUL59-813/85

Photo 1

Photo 2

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Page 2 of 13
Photo Documentation
Reference No.: WT12128113-D-F-L

Photo 3

Photo 4

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Page 3 of 13
Photo Documentation
Reference No.: WT12128113-D-F-L

Photo 5

Photo 6

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Page 4 of 13
Photo Documentation
Reference No.: WT12128113-D-F-L

Photo 7

Photo 8

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Page 5 of 13
Photo Documentation
Reference No.: WT12128113-D-F-L

Photo 9

Photo 10

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Page 6 of 13
Photo Documentation
Reference No.: WT12128113-D-F-L

Photo 11

Photo 12

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Page 7 of 13
Photo Documentation
Reference No.: WT12128113-D-F-L

Photo 13

Photo 14

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Page 8 of 13
Photo Documentation
Reference No.: WT12128113-D-F-L

Photo 15

Photo 16

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Page 9 of 13
Photo Documentation
Reference No.: WT12128113-D-F-L

Photo 17

Photo 18

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Page 10 of 13
Photo Documentation
Reference No.: WT12128113-D-F-L

Photo 19

Photo 20

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Page 11 of 13
Photo Documentation
Reference No.: WT12128113-D-F-L

Photo 21

Photo 22

Waltek Services (Shenzhen) Co., Ltd.


http://www.waltek.com.cn
Page 12 of 13
Photo Documentation
Reference No.: WT12128113-D-F-L

Model: KUL59-813/80

Photo 23

Model: KUL59-813/75

Photo 24