SITE ADDRESS JOB DESCRIPTION

26 ALBERT STREET, PROPOSED NEW GRANNY FLAT


GRANVILLE NSW-2142

INDEX TO SHEETS
SHEET TITLE REV
S0 COVER SHEET 0
S1 GENERAL NOTES 0
S2 MEMBER SCHEDULE 0
S3 SLAB ON GROUND & ROOF LAYOUTS 0
S4 LINTEL BEAMS LAYOUT 0
S5 SECTIONS & DETAILS 0

NOTE:
IT IS THE RESPONSIBILITY OF THE CLIENT IN CONSULTATION WITH THEIR
BUILDER TO CHECK AND VERIFY THE BUILDABILITY OF THE DESIGN AS
PRESENTED AND REFER ANY CONCERNS BACK TO THE ENGINEER PRIOR TO
CONSTRUCTION.

THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE PROJECT


ARCHITECTURAL AND OTHER CONSULTANTS DRAWINGS AND
SPECIFICATIONS.

THE SLAB SETOUT AT SITE SHALL BE AS PER CLIENT BRIEF.

THE BUILDER HAS TO VERIFY THE DIMENSIONS AS PER ARCHITECTURAL


DRAWINGS, ANY DISCREPANCIES IN DIMENSIONS SHOULD BE NOTIFIED
IMMEDIATELY TO THIS OFFICE.

NOT FOR CONSTRUCTION

PROJECT PROJECT NUMBER DRAWN BY DATE PRINT DATE


REVISIONS & AMENDMENTS SAFE AUSTRALIA
REV. DATE DESIGN & CONSULTING ENGINEERS PROPOSED NEW GRANNY FLAT 191107 ZH 24.12.2019 24.12.2019
DESCRIPTION
0 ISSUED FOR DISCUSSION 24.12.19
26 ABERT STREET, THE PONDS, NSW 2769

CIVIL, STRUCTURE, STORMWATER, PROJECT MANAGEMENT APPROVED BY CHECKED BY SHEET SIZE SCALE
SUITE 7, 5-7 ROSS STREET GRANVILLE, NSW 2142
PARRAMATTA, NSW 2150, Australia AN VR A3 NA
P: 02 7801 4847 DRAWING CONTENT
M: 04 3734 2436
COVER SHEET CLIENT DRAWING No. REVISION
E: contact@safeoz.com.au AZHAR M. NASIR
www.safeoz.com.au MIEAust, CPEng, NPER, (2016938) KIA ANVARI S0 0
GENERAL NOTES: CONCRETE WORK: STRUCTURAL TIMBER:
T.1 THE TYPE, QUALITY, PLACEMENT & FIXING OF ALL STRUCTURAL TIMBER SHALL
C.1 ALL WORKMANSHIP AND MATERIAL SHALL BE IN ACCORDANCE WITH AS 3600 & AS 2870 COMPLY WITH THE REQUIREMENTS OF AS1720 OR AS1684 WHERE
G.1 THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL
C.2. CONCRETE QUALITY SHALL BE AS TABULATED BELOW U.N.O AND SHALL BE VERIFIED BY APPROPRIATE.
AND OTHER CONSULTANTS DRAWINGS AND SPECIFICATIONS AND WITH SUCH
TEST. T.2 ALL TIMBER MEMBERS INCLUDING STRAP OR PLY BRACINGS SHALL BE
OTHER WRITTEN INSTRUCTIONS AS MAY BE ISSUED DURING THE COURSE OF
SELECTED IN ACCORDANCE WITH THE ABOVE CODES.
THE CONTRACT. ALL DISCREPANCIES SHALL BE REFERRED TO THE
T.3 ALL SCREWS AND BOLTS TO BE GALVANIZED AND FIXED IN ACCORDANCE WITH
ARCHITECT/ENGINEER FOR DECISION BEFORE PROCEEDING WITH THE WORK.
AS 1720.
G.2 DIMENSIONS SHALL NOT BE OBTAINED BY SCALING THE STRUCTURAL
MAX SIZE T.4 ALL TIMBER TO BE MINIMUM STRESS GRADE F7 U.N.O.
DRAWINGS. SLUMP CEMENT EXPOSURE CONCRETE COVER
ELEMENT AGG. T.5 TIMBER JOINTS SHALL BE FREE OF DEFECTS.
G.3 SETTING OUT DIMENSIONS SHOWN ON THE DRAWINGS SHALL BE VERIFIED BY (mm) TYPE CLASS. GRADE (mm)
(mm) T.6 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE DURING
THE BUILDER.
CONSTRUCTION THAT THE TIMBER IS PROTECTED FROM WEATHER AND THAT
G.4 DURING CONSTRUCTION THE STRUCTURE SHALL BE MAINTAINED IN A STABLE
THE STRENGTH IS NOT IMPAIRED IN ANY WAY.
CONDITION AND NO PART SHALL BE OVERSTRESSED.
T.7 ROOF TRUSSES ARE TO BE DESIGNED IN ACCORDANCE WITH AS 1720.
G.5 ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH THE SLABS ON 40 TOP T.8 THE TRUSS DESIGNER SHALL PROVIDE CERTIFIED DETAILS OF ALL PLATES AND
REQUIREMENTS OF THE CURRENT EDITIONS OF THE AS CODES AND THE 100 20 A A2 N32
BY-LAWS AND ORDINANCES OMA MA GRADE 45 EXT. CLEATS TO BE ATTACHED TO STEEL WORK TO SUPPORT ROOF TRUSSES, AS
PER MANUFACTURES SPECIFICATION.
G.6 THE STRUCTURAL ELEMENTS SHOWN ON THE DRAWINGS HAVE BEEN
DESIGNED IN ACCORDANCE WITH THE FOLLOWING CODES:
FOOTINGS & T.9 ROOF TRUSS DEFLECTION IS TO BE LIMITED TO SPAN/600 UNDER LONG TERM
100 20 A A2 N32 65 DEAD LOAD U.N.O.
CONCRETE - AS 3600 PIERS T.10 ROOF TRUSSES TO BE SPACED AT MAXIMUM 600 CENTERS U.N.O.
FOOTING - AS 2870
SUSPENDED 30 TOP T.11 FOR ALL ROOFING, INSULATION AND CEILING DETAILS REFER TO
STEEL - AS 4100 & AS 4600
80 20 A A2 N32 ARCHITECTURAL DRAWINGS.
SLAB 30 BTM
LINTEL SCHEDULE
FOUNDATIONS AND FOOTINGS:
C.3 ALL CONCRETE SHALL BE PLACED AND CURED IN ACCORDANCE WITH AS 3600 WHERE CURING
F.1 FOOTINGS HAVE BEEN DESIGNED FOR AN ASSUMED BEARING PRESSURE OF SPAN (mm) DESCRIPTION END BEARING
COMPOUNDS ARE USED IT MUST BE APPLIED AS FOLLOWS;
100kPa. BUILDER TO CONFIRM BEFORE PROCEEDING WITH CONCRETE POUR.
F.2 ASBESTOS HAS BEEN IDENTIFIED AT SITE AS PER CLIENT BRIEF. BUILDER TO
A) ONTO SLAB WITHIN 2HRS OF FINISHING OPERATION. 0- 900 75x10mm PLATE 100mm
B) ONTO WALLS AND COLUMNS IMMEDIATELY AFTER REMOVAL OF FORMWORK. 900-1050 100x10mm PLATE 100mm
ASSESS THE SOIL CONTAMINATION AND SEEK QUALIFIED OPINION AND
C.4 SIZES OF CONCRETE ELEMENTS DO NOT INCLUDE THICKNESS OF APPLIED FORMWORK.
APPROVAL IF NEEDED. 1050-1200 90x90x6 EA 100mm
C.5 CONSTRUCTION JOINTS WHERE NOT SHOWN SHALL BE TO THE APPROVAL OF THE ENGINEER.
F.3 FOOTINGS SHALL BE PLACED CENTRALLY UNDER WALLS AND COLUMNS UNLESS
C.6 BEAM DEPTH ARE WRITTEN FIRST AND INCLUDE SLAB THICKNESS. IF ANY. 1200-1500 90X90X8 EA 100mm
OTHERWISE NOTED.
C.7 HORIZONTAL FORMWORK SHALL BE STRIPPED WHEN APPROVED OF BY THE ENGINEER. 1500-1800 100X100X8 EA 150mm
F.4 ALL WORKMANSHIP & MATERIALS SHALL BE IN ACCORDANCE WITH AS 2870.
C.8 UNLESS NOTED OTHERWISE NO ALLOWANCE HAS BEEN MADE FOR STACKED MATERIALS OR
F.5 FILL USED IN CONSTRUCTION OF A SLAB EXCEPT WHERE THE SLAB IS 1800-2400 150X90X8 UA 150mm
MACHINERY ON THE CONCRETE STRUCTURE.
SUSPENDED SHALL CONSIST OF A CONTROLLED FILL OR ROLLED FILL IN
C.9 NO HOLES OR CHASES OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE 2400-3000 150X90X10 UA 150mm
ACCORDANCE WITH AS 2870
MADE IN CONCRETE ELEMENTS WITHOUT THE PRIOR APPROVAL OF THE ENGINEER. 3000-3700 150X90X12 UA 150mm
A) ROLLED FILL CONSISTS OF MATERIAL COMPACTED IN LAYERS BY REPEATED
C.10 REINFORCEMENT IS REPRESENTED DIAGRAMMATICALLY.
ROLLING WITH AN EXCAVATOR. ROLLED FILL SHALL NOT EXCEED 600mm 3700-5900 250 PFC + 12mm PLATE 150mm
C.11 SPLICES IN REINFORCEMENT MADE IN POSITIONS OTHER THAN SHOWN SHALL BE TO THE
COMPACTED IN LAYERS NOT MORE THAN 300mm FOR SAND MATERIAL OR
APPROVAL OF THE ENGINEER. WHERE THE LAP LENGTH IS NOT SHOWN IT SHALL BE SUFFICIENT WELDED TO BTM FLANGE
400mm COMPACTED IN LAYERS NOT MORE THAN 150mm FOR OTHER MATERIAL.
TO DEVELOP THE FULL STRENGTH OF THE REINFORCEMENT. OR EQUIVALENT GALINTEL
B) CONTROLLED FILL SHALL CONSIST OF WELL GRADED SAND FILL UP TO 800mm
C.12 WELDING OF REINFORCEMENT SHALL NOT BE PERMITTED UNLESS SHOWN ON THE STRUCTURAL
DEEP WELL COMPACTED IN NOT MORE THAN 300mm LAYERS BY VIBRATING
DRAWINGS.
PLATE OR VIBRATING ROLLER. NON SAND FILL UP TO 400mm DEEP, WELL NOTES:
C.13 PIPES OR CONDUITS SHALL NOT BE PLACED WITHIN THE CONCRETE COVER TO REINFORCEMENT
COMPACTED IN NOT MORE THAN 150 LAYERS BY A MECHANICAL ROLLER. CLAY 1. SET ANGLES WITH LONG LEG VERTICAL.
WITHOUT THE APPROVAL OF THE ENGINEER.
FILL SHOULD BE MOIST DURING COMPACTION. FOR COMPACTED DEPTHS 2. LINTELS EXCEPT FOR INTERNAL WALLS TO BE HOT DIPPED GALVANIZED.
C.14 ALL REINFORCING BARS SHALL COMPLY WITH AS 4671 ALL FABRIC SHALL COMPLY WITH
GREATER THAN THAT GIVEN ABOVE THE FILL SHALL BE SUBJECT TO CONTROL
AS 4671 AND SHALL BE SUPPLIED IN FLAT SHEETS.
AND TESTING. IF TEST FAILS THEN PIERS ARE REQUIRED. CONTACT THIS OFFICE
PRIOR TO FURTHER CONSTRUCTION.
C.15 REINFORCING SYMBOLS: STRUCTURAL STEEL:
N - DENOTES GRADE D500 HIGH STRENGTH DEFORMED BARS TO AS 4671. S.1 ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH
F.6 EDGE BEAMS MAY BE FOUNDED ON CONTROLLED FILL. EDGE BEAMS SHALL NOT
R - DENOTES GRADE R250 HOT ROLLED PLAIN BARS TO AS 4671. AS 4100 EXCEPT WHERE VARIED BY THE CONTRACT DOCUMENTS.
BE FOUNDED ON ROLLED FILL.
SL - DENOTES HARD-DRAWN WIRE SQUARE REINFORCEMENT FABRIC TO AS 4671. S.2 UNLESS OTHERWISE NOTED, ALL STEEL SHALL BE IN ACCORDANCE WITH:
F.7 TOP SOIL CONTAINING GRASS ROOTS OR OTHER ORGANIC MATERIAL SHALL BE
RL - DENOTES HARD-DRAWN WIRE RECTANGULAR REINFORCING FABRIC TO AS 4671. AS 3679.1 GRADE 300 FOR ROLLED SECTIONS.
REMOVED FROM THE AREA ON WHICH THE SLAB IS TO REST.
THE NUMBER IMMEDIATELY FOLLOWING THESE SYMBOLS IS THE BAR DIAMETER IN MILLIMETER AS 1163 GRADE 350 FOR RHS SECTIONS.
F.8 IF ANY FOOTING IS LOCATED SUCH THAT A LINE DRAWN AT 45 DEGREES FOR
C.16 FABRIC REINFORCEMENT TO BE LAPPED ONE MESH PLUS 30mm. LAPS IN POSITIONS OF MAXIMUM AS 1163 GRADE 350 FOR CHS SECTIONS.
CLAY AND 30 DEGREES FOR SAND FROM ITS BASE INTERSECTS A SERVICE
MOMENT ARE NOT PERMITTED. AS 3378 GRADE 350 FOR ALL PLATE.
TRENCH THE PIERS ARE REQUIRED AS PER DETAIL BELOW.
C.17 ALL REINFORCEMENT SHALL BE FIRMLY SUPPORTED ON INSULATED STEEL. PLASTIC OR AS 3679.1 GRADE 350 FOR ALL FLAT.
CONCRETE CHAIRS GENERALLY AT NOT GREATER THAN 800 CENTERS BOTH WAYS. RODS SHALL AS 1397 GRADE 450 FOR 1.5, 1.9, 2.4 AND 3.0 BMT OF COLD-FORMED STEEL
450 DIA CONCRETE PIERS BE TIED AT ALTERNATE INTERSECTIONS. SECTIONS.
FOUND BELOW LINE OF C.18 ALL TENSILE REINFORCEMENT TO BE LAPPED AS SHOWN (u.n.o) S.3 UNLESS NOTED OTHERWISE ALL WELDS SHALL BE 6mm CONTINUOUS FILLET
ZONE OF INFLUENCE WELDS AND ALL GUSSET PLATES SHALL BE 10mm THICK.
INTO NATURAL GROUND S.4 BUTT WELDS WHERE INDICATED IN THE DRAWINGS ARE TO BE COMPLETE
PENETRATION BUTT WELDS AS DEFINED IN AS 1554.
CL REINFORCED BAR N12 N16 N20 N24
S.5 UNLESS OTHERWISE SHOWN ALL BOLTS SHALL BE 16 DIA HIGH STRENGTH (H.S.)
BOLTS SHALL CONFORM TO AS 1252 AND SHALL BE INSTALLED IN ACCORDANCE
LAP LENGTH (mm) 500 600 700 800 WITH AS 4100 AS DIRECTED BY THE ENGINEER.
S.6 UNLESS NOTED OTHERWISE ALL BEAMS TO BE SUPPORTED ON BRICKWORK /
SERVICE ENGAGED BRICK PIERS PLACE INCOMPRESSIBLE PACKING AS REQUIRED UNDER
TRENCH THE ENDS OF THE BEAM TO ENSURE EVEN BEARING ON BRICKWORK. ALL
AY
CL STEELWORK IN CONTACT WITH EXTERNAL BRICKWORK TO BE HOT DIPPED
R GALVANIZED TO SPECIFICATION.
FO ND
45 SA
F OR
30

SERVICE TRENCH DETAIL NOT FOR CONSTRUCTION


NOT TO SCALE

PROJECT PROJECT NUMBER DRAWN BY DATE PRINT DATE


REVISIONS & AMENDMENTS SAFE AUSTRALIA
REV. DESCRIPTION DATE DESIGN & CONSULTING ENGINEERS PROPOSED NEW GRANNY FLAT 191107 ZH 24.12.2019 24.12.2019
0 ISSUED FOR DISCUSSION 24.12.19
26 ABERT STREET, THE PONDS, NSW 2769

CIVIL, STRUCTURE, STORMWATER, PROJECT MANAGEMENT APPROVED BY CHECKED BY SHEET SIZE SCALE
SUITE 7, 5-7 ROSS STREET GRANVILLE, NSW 2142
PARRAMATTA, NSW 2150, Australia AN VR A3 NA
P: 02 7801 4847 DRAWING CONTENT
M: 04 3734 2436
GENERAL NOTES CLIENT DRAWING No. REVISION
E: contact@safeoz.com.au AZHAR M. NASIR
www.safeoz.com.au MIEAust, CPEng, NPER, (2016938) KIA ANVARI S1 0
SLAB MEMBER SCHEDULE
MEMBER REFERENCE SIZE/SPACING GRADE TREATMENT / JOINT GROUP REMARKS (TIE-DOWN, CONNECTION, ETC)
PAINT

SLAB S1 100mm N32 - - 100THK RC SLAB ON GRADE WITH SL82


TOP MESH, 40mm COVER
EDGE BEAMS EB1 300 W x 400 D N32 - - 3 N12 TOP & BOTTOM REBARS & R10-300
STIRRUPS. COVERS ALL AROUND WILL BE 45 mm
INTERNAL BEAMS IB1 300 W x 400 D N32 - - 3 N12 TOP & BOTTOM REBARS & R10-300
STIRRUPS. COVERS ALL AROUND WILL BE 45 mm
R1 140 X 45 (TOP CHORDS) MGP10 H2S JD5 @ 600 C/C TIMBER ROOF TRUSS. REFER
DWG S5 FOR FURTHER DETAILS
ROOF TRUSS (TR1) ST1 35 X 35 (INTERMEDIATE STRUTS) MGP10 H2S JD5

T1 90 X 45 (TIE MEMBER) MGP10 H2S JD5

LINTEL BEAM (LB) SCHEDULE


SPAN LB (TILE ROOF) LB (SHEET ROOF) TC

≤ 1.7 m 120 X 45 MGP 10 120 X 45 MGP 10 1 STUD

1.7 - 2.3 190 X 45 MGP 10 190 X 45 MGP 10 2 STUDS


NOTES:
1. CONCEAL FLOOR BEAMS AND TRIMMERS IN JOIST DEPTH. 2.3 - 2.8 240 X 45 MGP 10 240 X 45 MGP 10 2 STUDS
2. CONCEAL VERANDAH BEAMS IN THE ROOF.
3. TYPICALLY POSITION BEARERS AND POLE PLATES BENEATH JOISTS.
4. INSTALL JOISTS AND SUPPORTS IN ACCORDANCE WITH MANUFACTURERS SPECIFICATION.
5. BEARERS, FLOOR BEAMS AND JOISTS TO BE SUPPORTED ON TIMBER FRAME U.N.O.
6. TYPICALLY PROVIDE 4 STUDS UNDER ALL POINT LOADS U.N.O.
7. FIX POLE PLATES SUPPORTING JOISTS TO STEEL BEAMS WITH M12 BOLTS AT 450 CRS.
8. NOMINAL JOIST NOGGING BETWEEN FLOOR JOISTS SHALL BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATION. FLOOR JOISTS SHALL BE PROVIDED WITH SUPPORT AND
MIDSPAN BLOCKING IN ACCORDANCE WITH AS1684 OR MANUFACTURER'S DETAILS.
9. LINTELS NOT DESIGNED TO SUPPORT TOP HUNG DOORS U.N.O.
10. PERIMETER WALLS ARE TYPICALLY LOAD BEARING WALLS
11. DENOTES STEP TO ARCHITECTURAL DETAILS.
12. TR DENOTE TIMBER TRUSSES TO MANUFACTURERS SPEC AT 600 CRS MAX.
13. TGT DENOTES TRUNCATED GIRDER TRUSS TO MANUFACTURERS SPEC.
14. 2S DENOTES TWO STUDS.
15. 3S DENOTES THREE STUDS.
16. 4S DENOTES FOUR STUDS.
17. DJ DENOTES DOUBLE JOIST.
18. LBW DEMOTES LOAD BEARING WALL.
19. NLB DEMOTES NON LOAD BEARING WALL. NOT FOR CONSTRUCTION
20. H.D.G. DENOTES HOT DIP GALVANISED.
21. FOR FULL DESCRIPTION OF MEMBERS AND THEIR DETAILS REFER 'MEMBER SCHEDULE'.

PROJECT PROJECT NUMBER DRAWN BY DATE PRINT DATE


REVISIONS & AMENDMENTS SAFE AUSTRALIA
REV. DATE DESIGN & CONSULTING ENGINEERS PROPOSED NEW GRANNY FLAT 191107 ZH 24.12.2019 24.12.2019
DESCRIPTION
0 ISSUED FOR DISCUSSION 24.12.19
26 ABERT STREET, THE PONDS, NSW 2769

CIVIL, STRUCTURE, STORMWATER, PROJECT MANAGEMENT APPROVED BY CHECKED BY SHEET SIZE SCALE
SUITE 7, 5-7 ROSS STREET GRANVILLE, NSW 2142
PARRAMATTA, NSW 2150, Australia AN VR A3 NA
P: 02 7801 4847 DRAWING CONTENT
M: 04 3734 2436
MEMBER SCHEDULE CLIENT DRAWING No. REVISION
E: contact@safeoz.com.au AZHAR M. NASIR
www.safeoz.com.au MIEAust, CPEng, NPER, (2016938) KIA ANVARI S2 0
NOR
TH
EB1

S1

BOUNDARY LINE
BOUNDARY LINE
TR1

NLB
NLB
IB1
NLB

A
S6

EB1
S1

EB1
A
S5
RB1

NLB
IB1

NLB
S1

EB1

2435

ROOF LAYOUT LAYOUT OF SLAB ON GRADE NOT FOR CONSTRUCTION


DOWNPIPE (TYP)
SCALE - 1 : 50 SCALE - 1 : 50
0 .25m .5m 1.0m 1.5m 2.0m 2.5m

1:25 @ A1 1:50 @ A3 1:70.7 @ A4

PROJECT PROJECT NUMBER DRAWN BY DATE PRINT DATE


REVISIONS & AMENDMENTS SAFE AUSTRALIA
REV. DATE DESIGN & CONSULTING ENGINEERS PROPOSED NEW GRANNY FLAT 191107 ZH 24.12.2019 24.12.2019
DESCRIPTION
0 ISSUED FOR DISCUSSION 24.12.19
26 ABERT STREET, THE PONDS, NSW 2769

CIVIL, STRUCTURE, STORMWATER, PROJECT MANAGEMENT APPROVED BY CHECKED BY SHEET SIZE SCALE
SUITE 7, 5-7 ROSS STREET GRANVILLE, NSW 2142
PARRAMATTA, NSW 2150, Australia AN VR A3 1:50
P: 02 7801 4847 DRAWING CONTENT
M: 04 3734 2436
SLAB ON GROUND & ROOF LAYOUTS CLIENT DRAWING No. REVISION
E: contact@safeoz.com.au AZHAR M. NASIR
www.safeoz.com.au MIEAust, CPEng, NPER, (2016938) KIA ANVARI S3 0
TC TC TC TC
LINTEL BEAM (LB) SCHEDULE
SPAN LB (TILE ROOF) LB (SHEET ROOF) TC LB LB

≤ 1.7 m 120 X 45 MGP 10 120 X 45 MGP 10 1 STUD

1.7 - 2.3 190 X 45 MGP 10 190 X 45 MGP 10 2 STUDS

2.3 - 2.8 240 X 45 MGP 10 240 X 45 MGP 10 2 STUDS

TC

LB
250

TC
LINTEL

TC
250

LB
30 X1.0 mm G.I. STRAP.
NUMBER OF NAILS
AS PER TABLE TC

TC

LB
BOLT TO SLAB
OR FLOOR FRAME TC
250

TC TC
100 MAX LB

TYPICAL LB TO TC CONNECTION DETAIL LAYOUT OF LINTEL BEAMS


N.T.S SCALE - 1 : 50

NOT FOR CONSTRUCTION


0 .25m .5m 1.0m 1.5m 2.0m 2.5m

1:25 @ A1 1:50 @ A3 1:70.7 @ A4

PROJECT PROJECT NUMBER DRAWN BY DATE PRINT DATE


REVISIONS & AMENDMENTS SAFE AUSTRALIA
REV. DESCRIPTION DATE DESIGN & CONSULTING ENGINEERS PROPOSED NEW GRANNY FLAT 191107 ZH 24.12.2019 24.12.2019
0 ISSUED FOR DISCUSSION 24.12.19
26 ABERT STREET, THE PONDS, NSW 2769

CIVIL, STRUCTURE, STORMWATER, PROJECT MANAGEMENT APPROVED BY CHECKED BY SHEET SIZE SCALE
SUITE 7, 5-7 ROSS STREET GRANVILLE, NSW 2142
PARRAMATTA, NSW 2150, Australia AN VR A3 1:20
P: 02 7801 4847 DRAWING CONTENT
M: 04 3734 2436
LINTEL BEAMS LAYOUT CLIENT DRAWING No. REVISION
E: contact@safeoz.com.au AZHAR M. NASIR
www.safeoz.com.au MIEAust, CPEng, NPER, (2016938) KIA ANVARI S4 0
1-No 14 TYPE 17 BUGLE BATTEN
TRIP-L-GRIP CONNECTOR EVERY RAFTER SCREW WITH MIN 38mm PENETRATION
USE 30 x 2.8mm GALV. REINFORCED HEAD
NAILS EQUAL TO OPPOSITE SIDE 2.5 X 0.8 mm
4 NAILS - R1 STRAP 4 NAILS
2 NAILS - WALL PLATE EACH END 2 NAIL-ON PLATES (1.0mm THK),
2 NAILS - STUD MIN. 5 NAILS/FACE
(TYP)

15 % 15 %

ROOF ARCHITECTURAL DETAILS

ST1
R1 R1
ST1 ST1
420

ST
ST

1
T1
CEILING LEVEL

250
TIE TO EACH PAIR OF
RAFTERS WITH 6 - 3.05 mm x 75 mm
NAILS PER END

EAVE GUTTER
DOWNPIPE (TYP) TO BE CONNECTED TYPICAL
TO STORMWATER DRAINAGE SYSTEM

30 X 1.0 mm GALV. PGI STRAP


LOOPED OVER PLATE & FIXED TO
STUD WALL WITH 4 - 32 X 2.8 mm
GALV.
90 X 45 MGP 10 @ 450 C/C
FLAT HEAD NAILS TO EACH END AT
STUDS WITH 90 X 45 TOP
EVERY ALTERNATE STUD (TYP)
& BOTTOM PLATES (TYP)

SL82 TOP MESH


40 TOP COVER (TYP)
FIX BTM PLATE TO SLAB
WITH M12 DYNABOLT @
900 mm C/C (TYP) FFL AT LEAST 100 mm
ABOVE NGL ALL AROUND
100

400
3 N12 TOP & 3 N12 TOP &
BOTTOM (TYP) EXISTING SLAB & COMPACTED FILL BOTTOM (TYP)
R10 @ 300 C/C OR PODS TO CARRY NEW SLAB FOR R10 @ 300 C/C
(TYP) NEW SLAB TO BEAR ON FIRM STRATA (TYP)

ADEQUATE DRAINAGE 300


COMMERCIAL GRADE
OF STORMWATER SYSTEM
VAPOUR BARRIER
ALL AROUND
SECTION A
SCALE - 1 : 20
NOT FOR CONSTRUCTION
0 100mm 200mm 400mm 600mm 800mm 1000mm

1:10 @ A1 1:20 @ A3 1:26 @ A4

PROJECT PROJECT NUMBER DRAWN BY DATE PRINT DATE


REVISIONS & AMENDMENTS SAFE AUSTRALIA
REV. DATE DESIGN & CONSULTING ENGINEERS PROPOSED NEW GRANNY FLAT 191107 ZH 24.12.2019 24.12.2019
DESCRIPTION
0 ISSUED FOR DISCUSSION 24.12.19
26 ABERT STREET, THE PONDS, NSW 2769

CIVIL, STRUCTURE, STORMWATER, PROJECT MANAGEMENT APPROVED BY CHECKED BY SHEET SIZE SCALE
SUITE 7, 5-7 ROSS STREET GRANVILLE, NSW 2142
PARRAMATTA, NSW 2150, Australia AN VR A3 VARIES
P: 02 7801 4847 DRAWING CONTENT
M: 04 3734 2436
SECTIONS & DETAILS CLIENT DRAWING No. REVISION
E: contact@safeoz.com.au AZHAR M. NASIR
www.safeoz.com.au MIEAust, CPEng, NPER, (2016938) KIA ANVARI S5 0