Sie sind auf Seite 1von 9

DAEWOO CP-310 1

General Information 1. Check for correct location of all neck compo- 2. Adjust VR401 so that the horizontal centre of PIF ADJUSTMENT Adjustment Sequence
nents (See figure. 5). the picture may be coincident with the The VCR should be adjusted in the sequence
2. Rough-in the static convergence at the centre mechanical centre of CRT. 1. APPARATUS CONNECTION & shown below.
Also Covers: of the CRT, as explained in the static conver- PRESETTING
gence procedure. FOCUS VOLTAGE ADJUSTMENT
DVT-1484D, DVT-2084D 3. Rotate the picture control to centre of its 1. Receive RETMA pattern signal. CONNECTION
rotation range, and rotate brightness control 2. Adjust the FOCUS VOLUME on the FBT and 1. Connect H-out of LSW-480 to X-axis of the
to max. CW position. make the picture on the screen be finest. oscilloscope and V-out of LSW-480 to Y-axis
Ferguson 4. Apply green color signal to procedure a green of the oscilloscope.
raster. 2. Connect the sweep signal output to TP1.
FG 14 CB 12V, FG 20 CB 12V 5. Loosen the deflection yoke tilt adjustment
RF AGC ADJUSTMENT
1. Receive PAL COLOR BAR signal in the VHF 3. Set ATTENUATOR of LSW-480 to 30dB.
wedges (3), loosen the deflection yoke clamp high band where the strength of signal can be 4. Supply 12V D.C. voltage (B+) to TP4.
Goodmans screw and push the deflection yoke as close 60-65 dB. 5. Supply 4-5V D.C. voltage to TP3.
as possible to the CRT screen. 2. Set the CONTRAST control to Max., the
TVC 1400 & TVC 14 VP 6. Begin the following adjustment with the tabs BRIGHTNESS control to provide adequate PRESET
on the round purity magnet rings set together, black and grey scales. 1) Oscilloscope Scaling
initially move the tabs on the round purity 3. Maintain the fine tuning on the screen, and a) Put the scale of X and Y of the oscilloscope
magnet rings to the side of the CRT neck. adjust VR601 (AGC DELAY CONTROL VR.) to D.C level.
Then, slowly separate the two tabs while at in order that it may be located on the position b) Set the horizontal time display to X-Y
Electrical Adjustments (TV) the CRT. This is accomplished as follows: the same time rotating them to adjust for a which the picture noise disappear on the c) Put the horizontal axis (X) to 1V/div. and the
uniform green vertical band at the CRT image. vertical axis (Y) to 2V/div.
GENERAL INFORMATION 1. Switch the receiver on allow it to warm up for screen.
All adjustments are throughly checked and 15 minutes. 7. Carefully side the deflection yoke backward to MAIN B+ (+103V) ADJUSTMENT 2) LSW-480 MARKER FREQ. SETTING.
corrected when the receiver leaves the factory. 2. Apply crosshatch pattern from dot/bar achieve green purity. (uniform green screen) 1. Set the Bright, Contrast and colour to MAX.
Therefore the receiver should operate normally generator to the receiver. Observe spacing Centre purity was obtained by adjusting the 2. Connect DC voltage meter to the P405 and fp(n+1) fs fc fp-2 fp fs(n-1)
and produce proper colour and B/W pictures between lines around edges of the CRT tabs on the round purity magnet rings, outer adjust VR801 for +103V DC. B/G, D/K, L 31.9 33.4 34.5 36.9 38.9 40.4
upon installation. But, several minor adjust- screen. edge purity was obtained by sliding the 31.9 33.5 35.07 37.5 39.5 41
ments may be required depending on the 3. Tilt the deflection yoke up and down, and deflection yoke forward. Tighten the deflection
particular location in which the receiver is insert tilt adjustment wedges 1 and 2 between yoke clamp screw.
operated. This receiver is shipped completely in the deflection yoke and the CRT until the mis- 8. Check for red and blue field purity by applying
a card-board carton. Carefully draw out the convergence illustrated in figure. 2 (A) has red signal and touch up adjustments, if
receiver from the carton and remove all packing been corrected. required. SERVO
materials. 4. Tilt the deflection yoke right and left, and 9. Perform black and white tracking procedure.
Plug the power cord into a AC power outlet. insert tilt adjustment wedge 3 between the 1. PLAYBACK PHASE
Turn the receiver ON and adjust the FINE deflection yoke and the CRT until mis- SCREEN & WHITE BALANCE ADJUSTMENT
TUNING for the best picture detail. Check and convergence illustrated in figure. 2 (B) has 1. This adjustment is to be made only after Mode Play
adjust all the customer controls such as been corrected. warming up at least 15 minutes. Adjustment Parts R595
BRIGHTNESS, CONTRAST and COLOUR 5. Alternately change spacing between, and 2. Receive B/W pattern signal Check Point TP396
Controls to obtain a natural B/W picture. depth of the insertion of, the three wedges 3. Set the RGB Bias VR (R522, R512, R502) to Test Equipments Oscilloscope
until proper dynamic convergence is ob- center. Test Tape DP-1
PROTECTION CIRCUIT CHECK tained. 4. Set the G, B Drive VR (R515, R505) to
1. Turn on the receiver. 6. Use a strong adhesive tape to firmly secure CENTER. Location of Adjustments Parts
2. The receiver must be turned off and changed latch of the three rubber wedges to the funnel 5. Set the CONTRAST, BRIGHTNESS, COLOR II. ADJUSTMENT OF AFT(B/G, D/K, I, L) MAIN PCB
in stand-by mode. of the CRT. control to MIN, and Sub-brightness control to 1. Connect the test point of LSW-480 to TP2.
7. Check purity and readjust, if necessary. CENTER. 2. Adjust L103 (AFT COIL) so that the P marker
HIGH VOLTAGE CHECK 6. Rotate the R, G and B Bias VR of the other point is located on the reference level.
1. Connect an accurate high voltage metre to STATIC (CENTRE) CONVERGENCE color which did not appear on the screen
the anode of the picture tube. ADJUSTMENT clockwise, until a dim white is obtained.
2. Turn on the receiver. Set the BRIGHTNESS 1. Switch the receiver on and allow it to warm 7. Rotate the Screen control gradually anti-
and CONTRAST controls to minimize (zero up for 15 minutes. clockwise until the last horizontal line
beam current). 2. Connect the output of a crosshatch generator disappears on the screen.
3. High voltage should be below 27.5kv to the receiver and concentrating on the 8. Set the CONTRAST, BRIGHTNESS, COLOR
(14:25.0kv, 21”: 29.0kv) centre of the CRT screen, proceed as follows: control to MAX.
a. Locate the pair of 4 pole magnet rings. 9. Set the G, B Drive VR to obtain the best white Observation Waveform
AUTOMATIC DEGAUSSING Rotate individual rings (Change spacing uniformity on the screen. Horizontal Axis: S/DIV
A degaussing coil is mounted around the picture between tabs) to converge the vertical red 10.Rotate the CONTRAST, BRIGHTNESS, Vertical Axis: CH1: SW30, CH2: V.OUT
tube so that external degaussing after moving and blue lines. Rotate the pair of rings COLOR controls until a dim raster is obtained Electrical Adjustments (VCR)
the receiver is normally unnecessary. Providing (maintaing spacing between tabs) to con- and touch-up adjustment of RGB Bias VR to
the receiver is properly degaussed upon verge the horizontal red and blue lines. (Refer obtain the best white uniformity on the screen. ALIGNMENT AND ELECTRICAL ADJUST-
installation. The degaussing coil operates for to fig. 1 (A)) MENT
about 1 second after the power of the receiver is b. After completing red and blue centre conver- SUB-BRIGHTNESS ADJUSTMENT
switched ON. If the set is moved or placed in a gence, locate the pair of 6 pole magnet rings. 1. White balance adjustment must proceed this For these adjustment, use the equipment
different direction, the power switch must be Rotage individual rings (change spacing procedure. mentioned below The suitable output waveform
switched off for at least 15 minutes in order to between tabs) to converge the vertical red 2. Set the CONTRAST, BRIGHTNESS, COLOR of the color-bar singal and proceed by using the
make the automatic degaussing circuit operate and blue (Magenta) and green lines. Rotate control to MIN. alignment tape and video signal. generator is Adjustment Procedure
properly. the pair of rings (maintaining spacing 3. Rotate the SUB-BRIGHTNESS VR (VRAO1) shown below.
Should the chassis or parts of the cabinet between tabs) to converge the horizontal red gradually CCW until the last beam disappears 1. Preparation
become magnetized to cause poor colour purity, and blue (Magenta) and green lines. (Refer to on the screen. Instrument and Tools Required 1) Play back on test tape (COLOR BAR).
use an external degaussing coil. Slowly move Fig. 1(B)) 1. Color TV receiver. 2) Set the oscilloscope to the CHOP mode.
the degaussing coil around the faceplate of the VERTICAL HEIGHT ADJUSTMENT 2. Oscilloscope having 10 MHz or more Connect CH1 to the SW PULSE (PT01 (3))
picture tube, the sides and front of the receiver COLOR PURITY ADJUSTMENT 1. Receive RETMA pattern signal. bandwidth. and CH2 to the VIDEO OUT (TP396) and
and slowly withdraw the coil to a distance of For the best result, it is recommended that the 2. Set the BRIGHTNESS control and CON- 3. Color-bar generator. trigger the scope with the signal from CHi.
about 2m before disconnecting it from the AC purity adjustment is made in final receiver TRAST control to Max., and the COLOR 4. Frequency counter. 2. Adjustment
source. location. If the receiver will be moved, perform control to centre. 5. VTVM. 1) Adjust R595 to position the rising edge of SW
If colour shading still persists, perform the adjustment with it’s facing east. The receiver 3. Adjust VR301 for the optimum vertical height 6. VOM (20 kµ/V). PULSE at 6.5H±0.5H from the V-SYNC.
COLOUR PURITY ADJUSTMENT and CON- must have been operating 15 minutes prior to and over scanning. 7. Audio oscillator.
VERGENCE ADJUSTMENTS procedures, as this procedure and the faceplate of the CRT 8. Audio attenuator. VIDEO
mentioned later. must be at room temperature. The receiver is VERTICAL CENTER ADJUSTMENT 1. EE LEVEL ADJUSTMENT
equipped with an automatic degaussing circuit. 1. Receive RETMA pattern signal. Signal Level and Input and Output Impedance
DYNAMIC CONVERGENCE ADJUSTMENT But, if the CRT shadow mask has come 2. Adjust VR302 so that the vertical center of the Requirement Mode EE (Stop)
Dynamic convergence (convergence of the excessively magnetized, it may be necessary to picture may be coincident with the mechanical 1. Video input: Negative sync, 1 Vp-p standard Adjustment Parts R395
three colour field at the edges of the CRT degauss it with manual coil. Do not switch the center of CRT. composite video signal, 75Ω. Check Point TP395
screen) is accomplished by proper insertion and coil. 2. Video output: Same as above. Test Equipments Oscilloscope Signal gen.
positioning of three rubber wedges between the The following procedure is recommended while HORIZONTAL CENTER ADJUSTMENT 3. Audio input: Line -5dBm 47KΩ. Input Signal Color bar signal with
edges of the deflection yoke and the funnel of using a dot generation. 1. Receive RETMA pattern signal. 4. Audio output: -5dBm, 10KΩ. or less. 100% white
DAEWOO CP-310 2
Adjustment Procedure Adjustment Procedure Test Tape Blank Tape
Electrical Adjustments Input Signal Color Bar
Location of Adjustments Parts
Main PCB
1. Preparation
(VCR) Cont’d 1. Preparation
1) Set the SYSTEM SELECT SWITCH to the 1) Set the LINE mode. Location of Adjustments Parts
Location of Adjustments Parts AUTO MODE. 2) Supply the COLOR BAR signal to the VIDEO Main PCB
Main PCB 2) Play back the test tape (COLOR BAR). IN JACK.
2) Connect the oscilloscope to TP396 (VOUT)
2. Adjustment and trigger the scope externally with the
1) Connect the oscilliscope to TP396 and trigger C.SYNC signal from TP31 3.
the scope externally with the C.SYNC signal 3) Record the signal for about 10 seconds in SP
from TP313. mode and play back the signal just recorded.
2) Adjust R396 to obtain 2.0±0.1 Vp-p between Confirm the playback output level is
the SYNC TIP and 100% white level. 2.0±0.2Vp-p. Adjustment Procedure

2. Adjustment Observation Waveform 1. Preparation


3. SYNC TIP FREQUENCY 1) Set the LINE mode.
If the playback output level is not 2.0±0.2Vp-p, Horizontal Axis: 10µS/DIV
adjust as follows. Vertical Axis:50 mV/DIV 2) Supply the signal in OPEN mode.
Mode (STOP) 3) Connect the AUDIO level meter to both
Observation Waveform Adjustment Parts R391, R393 1) Adjust R392 a little.
Horizontal Axis: 10µS/DIV 2) Record the Color bar signal for about 10 TP201 and TP202.
Check Point TP391 4) After inserting a blank tape, record in SP
Vertical Axis: 0.1 V/DIV Test Equipments Frequency counter seconds and play back the signal just
recorded. mode.
Input Signal No signal
3) Confirm the playback output level.
2. Adjustment
Location of Adjustments Parts 4) Repeat the procedure 1) to 4) until the
1) Adjust R292 to obtain 2.4mVrms.
Main PCB playback output level becomes 2.0±0.2Vp-p
between the SYNC TIP and 100% white peak. 3. Adjustment Inspection Standard
In comfirmation of recording playback
5. C RECORD CURRENT frequency characteristics, compared with 1
KHz recording-playback output level, (8KHz)
Mode EE Adjustment Procedure recording-playback output level is higher than
Adjustment Parts R399 & R491 the standard, increase the record bias and if
Check Point TP399 1. Preparation lower, decrease it.
Test Equipments Oscilloscope 1) Set the LINE mode.
Adjustment Procedure Test Tape Blank Tape 2) Supply the COLOR BAR signal to the VIDEO End
Input Signal Color Bar IN JACK.
1. Preparation
1) Set the LINE mode. Location of Adjustments Parts 2. Adjustment
Adjustment Procedure 1) Set the VCR to the EE mode.
2) Supply the COLOR BAR signal with 100% Main PCB
white to the VIDEO IN JACK. 2) Trigger the scope externally with the C.SYNC
1. Preparation signal from TP31 3.
1) Set the LINE mode. 3) Connect the oscilloscope to TP399.
2. Adjustment 2) Supply the input signal in the OPEN state.
1) Set the VCR to STOP (FE) mode. Adjust R399 until Y-FM record current
2) Connect the oscilloscope to TP395 and becomes 300±10 mVp-p.
2. Adjustment
trigger the scope externally with the compos- 1) Set the VCR to the FE (STOP) mode.
ite synchronous signal from TP31 3. AUDIO
2) Connect the frequency counter to TP391.
3) Adjust R395 to obtain 0.5±0.01 Vp-p between 3) Set the SYSTEM SELECT SWITCH to the 1. AUDIO PLAYBACK OUTPUT LEVEL
the SYNC TIP and 100% white level. PAL mode.
4) Adjust R393 to obtain 3.8 ±0.1 Mhz. Mode Play
2. PLAYBACK OUTPUT LEVEL Observation Waveform Adjustment Parts R291
4. FM DEVIATION Horizontal Axis: 10µS/DIV Check Point Audio Output
Mode PLAY Vertical Axis: 20 mV/DIV Test Equipments Audio Level Meter
Adjustment Parts R396 Mode REC PLAY Test Tape DP-1
Check Point TP396 Adjustment Parts R392
Test Equipments Oscilloscope Check Point TP396 Location of Adjustments Parts
Test Tape DP-1 Test Equipments Oscilloscope Main PCB
Input Signal Color bar with
Location of Adjustments Parts 100% white
Main PCB
Location of Adjustments Parts
Main PCB

Adjustment Procedure
Adjustment Procedure
1. Preparation
1) Set the LINE mode. 1. Preparation
2) Supply the COLOR BAR signal to the VIDEO 1) Connect the AUDIO level meter to the AUDIO
IN JACK. OUTPUT JACK.
2) Play back the test tape (DP-1).
Observation Waveform 2. Adjustment 2. Adjustment
Horizontal Axis: S/DIV 1) Set the VCR to FE mode. 1) Adjust R291 until the output level becomes
Observation Waveform -5 ±1.5dBm.
Vertical Axis: 0.5 V/DIV Horizontal Axis: 10µS/DIV 2) Connect the oscilloscope to TP399.
Vertical Axis: 0.5V/DIV Adjust R399 until Y-FM record current 2. AUDIO RECORD BIAS
becomes minimum.
3) Trigger the scope externally with the C.SYNC Mode REC
signal from TP31 3. Adjustment Parts R292
4) Adjust R491 until Color record current Check Point TP201, TP202
becomes 80±5 mVp-p. Test Equipments Audio Level Meter
Test Tape Blank Tape
6. Y RECORD CURRENT

Mode FE
Adjustment Parts R399
Check Point TP399
Test Equipments Oscilloscope
DAEWOO CP-310 3
Video Diagram
DAEWOO CP-310 4
Audio Diagram

Remote Control Diagram

Head Amp
Diagram
DAEWOO CP-310 5

Connection Diagram
(DVT-1484)
DAEWOO CP-310 6

Connection Diagram
(DVT-2084)
DAEWOO CP-310 7
Main
Diagram
(TV)
DAEWOO CP-310 8
Power Servo Syscon Diagram (DVT 1484P)
DAEWOO CP-310 9
Power Servo Syscon Diagram (DVT 2084P)