Beruflich Dokumente
Kultur Dokumente
2. SAFETY PRECAUTIONS
3. SYSTEM REQUIREMENTS
Page 1
G-SPEED eS INSTALLATION GUIDE
Page 2
G-SPEED eS INSTALLATION GUIDE
Page 3
G-SPEED eS INSTALLATION GUIDE
1. INTRODUCTION 4. WHAT’S IN THE BOX
Thank you for purchasing G-SPEED eS from G-Technology, Take a moment to ensure that the following items are
Inc. (G-Tech)! Specifically designed for professional content included in the box. If anything is missing, please call G-Tech
creation applications, G-SPEED eS features a high-speed at (310) 449-4599. Please keep the shipping container and
3Gbit/sec eSATA interface and provides RAID 0, 1, 5, 10 and packing materials. In the unlikely event that you need to
JBOD functionality when used in conjunction with the optional return G-SPEED eS to us for any reason, you must use the
G-Tech PCI Express (PCIe) RAID controller. Up to four G-Tech shipping container. If the Product is returned
G-SPEED eS units can be attached to the G-Tech RAID damaged caused by improper packaging, the warranty will be
controller for storage capacities to 16 TB and data rates over void and liability will rest with the user.
600 MB/sec. G-SPEED eS supports multi-stream video editing
workflows on Mac Pro workstations.
3. SYSTEM REQUIREMENTS
Page 4
G-SPEED eS INSTALLATION GUIDE
5. G-SPEED eS OVERVIEW 6. OPTIONAL G-TECH PCIe RAID CONTOLLER OVERVIEW
Disk Module
Lock Hole
Power Supply
LED
(4) High-speed
3 Gb/s eSATA ports.
Supports up to (4)
G-SPEED eS systems
Temperature/Fan RPM
Warning LED
6.1 Supported RAID Levels
If your G-SPEED eS shipped with the optional G-Tech
PCIe RAID controller, the system was configured as a
RAID 0 at the factory. The controller also supports
RAID 1, 5, 10 and JBOD configurations. If you wish to
Removable change the RAID mode, please refer to Section 10.
Fan
3 GB/sec For an explanation of supported RAID levels, please
eSATA refer to Appendix B.
Port
Page 5
G-SPEED eS INSTALLATION GUIDE
7. G-SPEED eS AUDIBLE ALARMS 8. SETTING UP G-SPEED eS WITH THE G-TECH PCIe
7.1 The G-SPEED eS enclosure is equipped with an audible RAID CONTROLLER
alarm that sounds when: G-SPEED eS comes pre-configured in RAID 0 mode and
formatted for MAC OS X. Connecting G-SPEED to your Mac
1. The internal temperature of the G-SPEED eS enclosure
Pro and configuring your system takes just a few steps as
reaches a temperature of 60° centigrade
outlined below.
and/or
8.1 Installing the G-Tech PCIe RAID Controller
2. When the main FAN fails or the RPM of the fan slows to
a state where the fan can longer adequately cool the 1. Install the G-Tech RAID controller into SLOT 4 (top slot)
system. of your Mac Pro workstation.
In addition to the audible alarm, the Temperature/Fan
Warning LED located on the front bezel of G-SPEED eS
will illuminate.
If you hear an audible alarm and see the RED warning LED on
the front of G-SPEED eS, stop using G-SPEED eS immediately. G-Tech PCIe
Check to see if the fan is spinning and move the unit to a RAID Controller
cooler location. If you require a new fan, contact G-Tech
Support for a replacement.
Page 6
G-SPE
EED eS INSTA
ALLATION GUIDE
8.2 Attaching G-S SPEED eS to the G-TECH RA AID Controllerr 2 Double-click
2. k on the “G-Tech RAID Controlller” installer
1. Attach one ennd of the suppliied eSATA cable
e to the eSATA package as shown below.
port located on
o the back of G-SPEED
G eS.
2. Attach the oth
her end of the eSATA cable to Port 1 (leftmost
port) on the G-Tech
G RAID co
ontroller as shown below.
Check fo
or software update
es at
www.g-technology.com/Support/
http://w
If you are
a upgrading so oftware you mustt un-install the
previouus version first. S
See section 8.4 fo
or details
3 The followin
3. ng window will a appear. Follow the
ower cord to the
3. Attach the po e back of G-SPE
EED eS and instructions to load the sofftware.
connect the other
o end to AC
C power.
4. Power on G-S
SPEED eS.
Pag
ge 7
G-SPE
EED eS INSTA
ALLATION GUIDE
8.4 Uninstalling the
t G-Tech PC
CIe RAID Conttroller Softwa
are 3. The followin
3 ng will appear in
n your browserr window.
Enter “admin” as the Userr Name and “00 000” (four
1. Double-click on
o the uninstall.command file located in the
he Password and
zeros) as th d click on the <Login>
<
“Manuals-Drivvers” folder on the included CD as shown
button.
above.
1. Open your we
eb browser and
d enter the follo
owing address:
/localhost:740
https:// 02
Pag
ge 8
G-SPE
EED eS INSTA
ALLATION GUIDE
4. The main screeen of the web GUI will appea ar as shown 10. CHANGING
C TH
HE G-TECH RAID CONTOLLE
ER MODE
below. Note that the G-SPEE ED eS is set up as a RAID 0.
The G-SPEED eS/G-Tech RAID
T D controller com
mbination is
our drives in the unit are displayed in the
Each of the fo
c
configured at th
he factory in RA
AID 0 mode. RAID
R 1, 5, 10 an
nd
lower Section
n of the GUI.
J
JBOD modes arre also available
e. The web GUII is used to
c
change the modde of operation. Follow the diirections below to
c
change modes.
Pag
ge 9
G-SPE
EED eS INSTA
ALLATION GUIDE
4. Click on the <DELETE>
< buttton. The following window 7. Select RAID
7 D 5 for “Array TType:”, enter G--SPEEDeS-R5
will appear. Click
C the <OK> button to proce eed. for “Array Name:”, select F Foreground an nd Write Back
k
for “Initialization Method:”” and “Cache Po olicy:”
respectively y and click the <
<Select All> buutton.
WARNING:
W This will delete any data
stored on G-SPEED eS!
e
Page
e 10
G-SPE
EED eS INSTA
ALLATION GUIDE
9. C
Click the <OK> > button. The following
f windoow will appear.
T
The GUI will ind
dicate that the G-SPEED eS is initializing.
11. CONFIGURING
C G TWO G-SPEE
ED eS UNITS IN
I RAID 5 MO
ODE
10.The
T RAID 5 inittialization proce
ess takes appro oximately 1:45
p TB of final capacity.
per c Oncee the initializatio
on process is
c
complete, the GUI
G will indicate e “Type” as RA AID 5 and
“
“Status” as Nor rmal .
ms will mount o
3. Both system on the desktop.
Page
e 11
G-SPE
EED eS INSTA
ALLATION GUIDE
4. U
Unmount both G-SPEED eS un
nits by dragging
g the icons to 6. Click on the “Maintenance” link next to the array with “OS
S
t
the trash. Name” GS Dis sk 1_0. The wiindow shown below will appea ar.
5. L
Launch the G-TTech RAID Controller web GUI.. With the two
u
units attached to
t the G-Tech RAID
R controller,, the GUI will
d
display informa
ation like that shown below.
Page
e 12
G-SPE
EED eS INSTA
ALLATION GUIDE
8. Click the <OK
K> button to de
elete the array. 11
1. Click the <OK>
< button to delete the array. Both
arrays have now been deleted as s shown below.
9. Click on the “Maintenance” link next to the
e array with “OS
S
Name” GS Dis sk 1_1. The window below will appear.
Page
e 13
G-SPE
EED eS INSTA
ALLATION GUIDE
13. Select RAID 5 for “Array Type:”, enter G-S SPEED-eS- 14
4. The followin
ng window will a
appear.
R5 for “Array Name:”, selectt Foreground and Write
Back for “Inittialization Methhod:” and “Cachhe Policy:”
respectively and
a click the <S
Select All> buttton then
Click the <Creeate> button.
15
5. Click the <OOK> button. Thhe following window will appear
to indicate that
t the G-SPEE
ED eS is initializ
zing.
Page
e 14
G-SPE
EED eS INSTA
ALLATION GUIDE
15. The RAID 5 innitialization pro
ocess takes app proximately 1:445 The GUI will display
d information like that sh
hown below. An n
per TB of fina
al capacity. Onc ce the initialization process is exclamation mark
m on the G-SPEED eS icon indicates that
complete, thee GUI will indicaate “Type” as RAID
R 5 and the “Status” of
o the array is C
Critical. The lower portion of
“Status” as Normal.
N the GUI indica
ates which drive in which G-SPEED eS unit
has failed.
16. The Mac OS will
w display the “Disk Insertion n” window
indicating thee G-SPEED eS is s now ready to be initialized.
Click on the <Initialize>
< buttton to launch the
t Apple Disk
Utility and reffer to your systtem documenta ation for
instructions.
12. WH
HAT TO DO IN THE EVENT OF O A DISK DRI IVE FAILURE
Th
he G-Tech RAID controller conttinually monitors the health off
ea
ach of the disk drives
d in G-SPE EED eS. In the event of a disk
k
faiilure, an audible alarm will sou
und. The web GUI will also
report the failed drive and its phhysical position
n.
Page
e 15
G-SPE
EED eS INSTA
ALLATION GUIDE
3 Remove the
3. e failed drive (In this example Drive 3, of the
e
REMOVING THE W
R WRONG DRIVE WI ILL RESULT IN THE
G-SPEED eS S connected to port 2 of the G-Tech
G RAID
L
LOSS OF THE ARR
RAY AND ALL OF THE
T CONTENT
controller) by
b inserting the e provided key in to the lock S
STORED ON G-SPEEED eS.
hole and geently sliding thee drive module out of the
enclosure. he failed drive w
4. Replace th with a new diskk module and
secure in place. Once thhe drive has spuun up to speed,,
the GUI will
w indicate thatt the array is re
ebuilding (The
“Status” shows Rebuildiing and the percentage
complete) as shown belo ow. The rebuild d time is
approxima ately 2 hours pe
er TB.
WAR RNING: Make absollutely sure that you u remove the failed d
drive indicated by the GUI.
G If multiple G-S
SPEED eS units are e
conne ected to the G-Techh RAID controller, it is a good idea to
o
w the cable to ensure you know which
follow h Port # the array isi
conne ected to on the RAIID controller.
Page
e 16
G-SPEED eS INSTALLATION GUIDE
13. TECHNICAL SUPPORT 14. LIMITED WARRANTY
If you encounter any difficulties while installing G-SPEED, G-Technology Inc. (G-Tech) warrants your Product against
please contact G-Tech Technical Support via one of the any defect in material and workmanship, under normal
following ways: use, for the designated warranty period. If the Product
should become defective within the warranty period,
Telephone: (310) 449-4599 G-Tech, will at its discretion, repair or replace the Product.
Fax: (310) 449-4670 Repair or replacement parts or Products will be furnished
E-mail: support@g-technology.com on an exchange basis and will be either new or
Internet: http://www.g-technology.com/support reconditioned. All replaced parts or Products shall become
the Property of G-Tech. This warranty shall not apply if the
When contacting Technical Support, make sure to be in front Product has been damaged by accident, misuse, abuse or
of your computer and have the following information readily as a result of unauthorized service or parts. Warranty
available: service is available to the purchaser by obtaining a Return
Material Authorization number (RMA) and by delivering
• Your G-SPEED eS serial number (on bottom of unit) the Product during the warranty period to an authorized
• Operating system and version G-Tech service facility or to G-Tech. The purchaser shall
• Computer brand and model bear all shipping, packing and insurance costs and all
• eSATA host adapter brand and model other costs, excluding parts and labor, necessary to
• Amount of memory installed effectuate repair, replacement or refund under this
• Other devices attached to your computer warranty. All returned Product must be shipped to
G-Tech in the original shipping container.
Thank you for purchasing G-SPEED eS. If you have any
comments or questions about this manual or the Product, For more information on how to obtain warranty service,
please call (310) 449-4599, or send an email to an RMA number or to acquire shipping materials, contact
info@g-technology.com. G-Tech at 1653 Stanford Street, Santa Monica, CA 90404,
(310) 449-4599 or support@g-technology.com.
Page 17
G-SPE
EED eS INSTA
ALLATION GUIDE
APPE
ENDIX A: WEB
B GUI A.1 Manage: Array
A
1. Name: Array
A name (as shown in GUI only).
1 Manage:
1.
Array: This s is the main screen of the G-SPEED eS 2. Type: Displays RAID lev
vel of array.
web GUI. G-SPEED
G eS is configured an nd monitored
from this pa
age. (See Appe endix A.1 for de etails) y: you guessed it… capacity off the array.
3. Capacity
Devices: Hard
H drive param
meters are mod dified on this
4. Cache Policy:
P Displays current write
e cache policy
page (you should not make m any chan nges on this
for RAID
D protected a arrays. For more
m info see
page as thet drives aree configured for optimal
appendix
x A.1.7.7
performance with the G-SP PEED eS.
Spare Poo ol: When conffigured in prottected mode
5. OS Nam me: Controllerr assigned na
ame that will
drives can be
b assigned to a “spare pool”” (sometimes
display in
n Disk Utility.
called hot spare).
s These drives
d will be automatically
a
added to the Array in the event
e of a drive
e failure.
6. Status: Displays
D currennt status of arra
ay.
Norma al: All OK
2 Events: All events of the G-SPEED eS controller
2. c are
Critica
al: Drive failure
e has occurred
recorded he ere, such as array
a changes and failures.
Initiallizing: Building
g RAID 1, 5 or 10 array
These even nts can be emmailed by settinng up email
Rebuiilding: Parity data being recon nstructed
notification under the “Setttings” tab.
6 Logout: Sa
6. ay goodbye
Page
e 18
G-SPE
EED eS INSTA
ALLATION GUIDE
7.4 OCE/ORL LM:
Online Capacity Expansio on: It is possible to expand th
he
capacity of
o an existing arrray when additional
G-SPEED eSe units are addded to the systtem.
Online RAAID Level Migraation: it is posssible to change
the RAID level of an exis
sting array.
RAID 0 RAID 5
Page
e 19
G-SPE
EED eS INSTA
ALLATION GUIDE
8.1 Array Type
e: select the RA
AID level for new
w array
8.2 Array Namme: This is the name that wiill be displayed
d in
the MAIN pa
age of the GUI.
8.3 Initializatio
on Method: Se
ets the priority of the RAID
creation pro
ocess.
Foregrou und: All controlller resources are
a used for th he
8. C
Create Array creation process
p and thhe array is nott available unttil
C
Click on “Create Array” and the
e following will appear. complete.
Backgrou und: Minimal controller reso ources are use ed
for the cre
eation process and the array y is available fo
or
immediatee use.
NOTTE: RAID protection is not available
until initialization is complete
Location: “Controller#
#/Port#/Drive
e#”
Page
e 20
G-SPE
EED eS INSTA
ALLATION GUIDE
9. Lo
ocation: Show
ws the location of
o disks attache
ed to the
controller.
Lo
ocation: “Contr
roller#/Port#/
/Drive#”
10. Moodel: Displays s the drive moodel and serial number of (This page left inte
entionally blan
nk)
dis
sks currently atttached to the controller.
c
11. Ca
apacity: Displaays the advertised capacity of
o the disks
currently attache
ed to the contro
oller.
12. Maax Free: Displays the maxim mum free capaacity of the
dis
sks currently atttached to the controller.
c
13. Re
escan: Rescan ns the eSATA bus to detectt any new
de
evices attached.
14. Be
eeper Mute: Mutes
M audible be
eeper.
NOTE: Beepe er will sound when a drive fails or an array
a is
disconnected from the system without
w first selectin
ng
“Unplug” in th
he Array Maintenannce menu.
Page
e 21
G-SPE
EED eS INSTA
ALLATION GUIDE
3. SAF-TE: This
s feature is not currently suppo
orted.
5. Password: Changes
C login p
password. Defau
ult is 0000
Page
e 22
G-SPEED eS INSTALLATION GUIDE
APPENDIX B: RAID levels explained APPENDIX C: Notes
RAID
Level Description Advantage Disadvantage Ideal For… When the G-Tech web GUI is open dropped frames
0 Disk striping Offers the highest No fault tolerance - Content creation may occur in editing applications such as Final Cut
performance and a failure of one drive applications Pro. We recommend not having the GUI open while
useable storage in the array results requiring highest
capacity of 100% in complete data storage capacity
working in these programs.
of total available loss
storage capacity It is recommended not to exceed the standard eSATA
1 Mirroring Maximum level of Useable storage Applications in cable length of 1 meter (3 feet).
data protection as space is 50% of which data
identical data is total available security is
written to multiple capacity paramount Up to (4) G-SPEED eS storage units can be attached
drives to the G-Tech RAID controller for up to 16TB of
5 Disk striping High read Useable storage Content creation capacity and over 600 MB/sec of performance.
with performance, capacity equals applications
distributed medium write total capacity of all requiring data
parity performance with drives in the array protection Replacements / extra G-SPEED eS disk modules are
data protection in less the capacity of available for purchase online at:
case of a drive one drive. www.g-technology.com/products/g-speed-es.cfm
failure.
For example, a 4x
1TB RAID 5 yields
a useable capacity
of 3 TB.
Page 23