Low Voltage Switchboards and Switchgear

1.0 CMP Switchboards.................................................................................1-3 1


Standards and Certifications................................................................................... 1-4
Product Selection.................................................................................................... 1-4
Technical Data and Specifications........................................................................... 1-5
Layouts and Dimensions......................................................................................... 1-6

2.0 Pow-R-Line CS Switchboards................................................................2-9 2


Standards and Certifications................................................................................... 2-10
Product Selection and Specifications...................................................................... 2-10
Layouts and Dimensions......................................................................................... 2-14

3.0 Pow-R-Line C Switchboards..................................................................3-19 3


Standards and Certifications................................................................................... 3-21
Product Selection.................................................................................................... 3-22
Technical Data and Specifications........................................................................... 3-25

4.0 Commercial Metering Switchboards....................................................4-29 4


Standards and Certifications................................................................................... 4-30
Product Selection.................................................................................................... 4-30
Dimensions............................................................................................................. 4-30

5.0 Integrated Facility Switchboards..........................................................5-31 5


Features, Benefits and Functions........................................................................... 5-32
Options................................................................................................................... 5-32
Standards and Certifications................................................................................... 5-32
Product Selection.................................................................................................... 5-33
Technical Data and Specifications........................................................................... 5-41

6.0 Pow-R-Line C Switchboards with 6


Drawout Moulded-Case Circuit Breaker...............................................6-43
Standards and Certifications................................................................................... 6-44
Product Selection.................................................................................................... 6-45
Technical Data and Specifications........................................................................... 6-45
Dimensions............................................................................................................. 6-45

7.0 Generator Connection Assemblies 7


Generator Quick Connect Switchboards............................................7-48
Standards and Certifications................................................................................... 7-49
Product Selection.................................................................................................... 7-49
Technical Data and Specifications........................................................................... 7-49
Dimensions............................................................................................................. 7-49
Customer Service Termination Enclosure...........................................7-50
Roll-Up Generator Quick Connect Assembly.....................................7-52

8.0 Pow-R-Line C Switchgear......................................................................8-55 8


Standards and Certifications................................................................................... 8-58
Optional Breaker Accessories................................................................................. 8-58
Dimensions............................................................................................................. 8-60

9.0 Switchboard Accessories and Modifications.......................................9-61 9


Moulded-Case Circuit Breakers
Magnum Power Circuit Breakers............................................................................ 9-64
Trip Units................................................................................................................. 9-65
Fusible Switches..................................................................................................... 9-71
Surge Protection Devices....................................................................................... 9-75
Metering................................................................................................................. 9-76

Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 1-1


Low Voltage Switchboards and Switchgear
CMP Switchboards

Contents
CMP-A1 Switchboard CMP-A2 Switchboard
1
Description Page
Standards and Certifications.................................... 1-4 2
Product Selection.................................................... 1-4
Technical Data and Specifications............................ 1-5 3
Layouts and Dimensions......................................... 1-6
4
5
6
7
8
9
1
CMP Switchboards 1
Product Description Features, Benefits sprinklerproof, & components totally front 1
Eaton’s CMP switchboard and Functions NEMA 3R optional accessible to enable the
combines all three The service entrance • Sealing screws, knurled panel to be installed against 1
components of a service panel is CSA® approved thumb screws and the wall. Freestanding option
entrance application into a and completely factory padlock hasp is available for 18" deep
enclosure.
1
single cell, including a main assembled. Barriers are • Utility ground stud
service compartment, a
utility metering section and
provided to isolate the
main disconnect, the utility
• Hydro stubs are available All covers are painted 1
• Distribution cell ANSI 61 grey.
the distribution feeders, metering compartment
providing the most flexible and the distribution
accommodates Eaton’s Busbar System 1
Series C and Series G
and compact footprint for section into three separate
the entire service entrance compartments. The design
breakers, fusible switches
(FDPW), metered switches
• Tin-plated aluminum
1
switchboard. allows for the assembly • Silver-flashed copper
up to 200A (FSMC)
to be reversed in the field and chassis-mounted • Tin-plated copper
1
Application Description without modification and panelboards
Eaton's CMP switchboard is
to accommodate either top
or bottom entry of service • User metering (refer to Tab Main Breaker 1
ideally suited to commercial 9-Components, or contact
entrance cables. Eaton type main breaker,
and industrial applications Eaton for more information) maximum 800A (CMP-A1) 1
such as: • Freestanding (18"D Only) Surge protection devices
• or 1200A (CMP-A2) with
• Light Commercial • Compact and (refer to Tab 9-Components, standard thermal-magnetic or 1
space-efficient or contact Eaton for more solid-state trip units available.
Retail
• • Top or bottom entry information) The trip unit on the standard
thermal-magnetic breaker
1
• Shopping Plaza • Meets the provincial • Door-Over-Distribution
may be changed; however,
• Shopping Centers
and municipal metering
requirements
• Special Colours
all power to the switchboard
1
must be disconnected prior to
• Institutions / Schools • Accommodates a variety
of utility CTs and PTs
Enclosure removal of the breaker cover. 1
• Agricultural The service entrance
• CSA approved up to
800A (CMP-A1) and
switchboard is standard CSA The main breaker section
comes complete with
1
• Small buildings Type 1 & sprinklerproof, and
1200A (CMP-A2) at provisions for padlocking
• Sports and entertainment 600 Vac
NEMA 3R is optional. The
CSA Type 1 & sprinkerproof the main breaker and the 1
facilities • Main breaker maximum options are fabricated sealing screws on the front
800A (CMP-A1) and from code gauge formed cover. Grounding is supplied 1
1200A (CMP-A2) galvanized steel, complete with a removable disconnect
• Breakers are padlockable with flat covers to form a rigid link to ground the neutral,
the service conduit and the
1
to ensure maximum deadfront totally enclosed
system ground.
security structure. 1
• Standard enclosure All compartments are
ratings of CSA Type 1 & designed to make 1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 1-3
Low Voltage Switchboards and Switchgear
CMP Switchboards

Utility Metering Compartment Distribution Section Standards and Certifications Product Selection
1 The utility metering The distribution section • CSA C22.2 No. 31 Description Type
compartment is designed accepts the installation CSA C22.2 No. 244
2 to meet the provincial of circuit breakers on a

• CSA C22.2 No. 229
800A maximum at 600 Vac CMP-A1
and municipal utility Pow-R-Line 4 type interior. 1200A maximum at 600 Vac CMP-A2
3 requirements. It is bussed A flat cover is supplied and
and pre-drilled to accept any space not occupied by Breaker Accessories
4 standard bus type current
transformers. Utility CTs
a feeder breaker has a filler
plate, allowing no access to
• Padlock hasp
• Visible windows
and PTs can be easily parts when energized.
5 factory or field installed. The • Electronic trip units
compartment has provisions The distribution section • Shunt trip
6 for sealing the front cover, accommodates 14 three-pole
• Auxiliary switch
and the cover has a hinged breakers (“21X” of circuit
breaker distribution space; • Bell alarm
7 door for easy access.
1X = 1-3/8 inch). • Undervoltage release
Metering options include:
8
• CTs—window type and
9 bar type
• External clamp-on CTs to
1 •
verify meter
Up to four PTs in utility
compartment
1 • Neutral and ground
studs available
1
Utility specific options:
1 • Standard
• BC Hydro
1 • Hydro Quebec
Alectra utilities
1 •

1
1
1
1
CMP-A1 CMP-A2
1
1
1
1
1
1
1
1
1
1
1
1-4 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
CMP Switchboards

Technical Data and Specifications


1
Rating Breaker Options CMP-A2
The service entrance panel bus is rated to 800A (CMP-A1), kA Value
2
Device Ampere Mounting
1200A (CMP-A2), 600V, three-phase, four-wire, 60 Hz. Type
Main Breakers
Rating 240V 600V Height a
3
Interrupting Rating
• Maximum 65 kA at 600V
KD Frame 70–400 b 65–200 25–65 4X 4
LD Frame 300–600 65–200 25–50 6X
• Maximum 200 kA at 240V LG Frame 250–600 65–200 18–65 4X 5
MDL Frame 300–800 c 65–100 25–35 6X
Breaker Options CMP-A1 NG Frame 500–1200 65–200 25–65 6X 6
kA Value Branch Breakers
Device Ampere Mounting
Type Rating 240V 600V Height FD Frame 15–225 18–200 14–35 3X 7
Main Breakers JD Frame 70–250 65–200 18–35 3X

KD Frame 70–400 b 65–200 25–65 4X KD Frame 70–400 b 65–200 25–65 4X 8


LD Frame 300–600 65–200 25–50 6X LD Frame 300–600 65–200 25–50 6X

LG Frame 250–600 65–200 18–65 4X LG Frame 250–600 65–200 18–65 4X 9


MDL Frame 300–800 c 65–100 25–35 6X MDL Frame 300–800 c 65–100 25–35 6X

NG Frame 320–800 65–200 25–65 6X NG Frame 500–1200 65–200 25–65 6X 1


Branch Breakers
FD Frame 15–225 18–200 14–35 3X
Branch Fusible Switches-CMP A2 1
Cell Width
JD Frame
KD Frame
70–250
70–400 b
65–200
65–200
18–35
25–65
3X
4X
Device
Type 38-Inch 44-Inch
Mounting
Height a 1
30/30A twin Y Y 4X
LD Frame
LG Frame
300–600
250–600
65–200
65–200
25–50
18–65
6X
4X 30/60A twin Y Y 4X
1
60/60A twin
100/100A twin
Y
Y
Y
Y
4X
5X
1
FSMC Device Options CMP-A2
200A (single or twin)
400A
Y
Y
Y
Y
6X
9X
1
Ampere
Rating
Single
or Twin X Space a
600A
800A
Y
N
Y
Y
11X
11X
1
30/30
30/60
Twin
Twin
7X
7X
1200A N Y 15X
1
NNote
60/30
60/60
Twin
Twin
7X
7X
a 1X = 1-3/8 inch.
b Ampere ratings below 100A available with electronic trip unit only.
1
100/100
200
Twin
Single
7X
7X
c Ampere ratings below 400A available with thermal-magnetic only.
1
1
1
1
1
Twin 30A, 60A or 100A FSMC Switch
1
1
1
1
Single 200A FSMC Switch 1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 1-5
Low Voltage Switchboards and Switchgear
CMP Switchboards

Dimensions (CSA Type 1 & Sprinklerproof)


1 Approximate Dimensions in Inches (mm)

2 Layout A: Top-Fed CMP-A1 Main/PUC/21X Layout B: Bottom-Fed CMP-A1 Main/PUC/21X


Distribution (800A Maximum at 600 Vac) Distribution (800A Maximum at 600 Vac)
3
4
5
6
7
8
9
1
1
1
1
1
Layout C: Top-Fed CMP-A2 Main/PUC/21X Layout D: Bottom-Fed CMP-A2 Main/PUC/21X
1 Distribution (1200A Maximum at 600 Vac) Distribution (1200A Maximum at 600 Vac)

1
1
1
1
1
1
1
1
1
1 b
b

1 NNote

1
a 1X = 1-3/8 inch
b Bottom-fed: Only 2 rows of twin 100A or single 200A FSMC. Top fed: Only 1 row of single 200A or twin 100A FSMC

1 c For NEMA 3R dimensions consult your local Eaton sales representative

1
1
1-6 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
CMP Switchboards

Dimensions (CSA Type 1 & Sprinklerproof)


Approximate Dimensions in Inches (mm)
1
Layout E: Top-Fed CMP-A2 Main/40X Layout F: Bottom-Fed CMP-A2 Main/40X 2
Distribution (1200A Maximum at 600 Vac) Distribution (1200A Maximum at 600 Vac)
3
4
5
6
7
8
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 1-7
Low Voltage Switchboards and Switchgear
CMP Switchboards

This page intentionally left blank.


1
2
3
4
5
6
7
8
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1-8 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Pow-R-Line CS Switchboards

Contents
Pow-R-Line CS Switchboards
1
Description Page
Standards and Certifications.................................... 2-10 2
Product Selection and Specifications...................... 2-10
Layouts and Dimensions......................................... 2-14 3
4
5
6
7
8
9
1
Pow-R-Line CS Switchboards 1
Product Description Application Description Features, Benefits • Breakers are padlockable 1
Eaton’s Pow-R-Line CS The Pow-R-Line CS and Functions to ensure maximum
switchboard is the most switchboard is ideally suited • Compact and space- security 1
compact expandable service to commercial and industrial efficient • Distribution cell
entrance and distribution applications such as: • Top or bottom entry accommodates Eaton’s 1
solution in Canada. Eaton’s Series C and Series G
• Light Commercial
Pow-R-Line CS switchboard
is a compact solution that
• Meets the provincial
and municipal metering
breakers, fusible switches 1
• Retail (FDPW), metered switches
offers main device, utility requirements
metering, and distribution in • Shopping Plaza
up to 200A (FSMC)
and chassis-mounted
1
a single cell. Additionally, the
• Utility ground stud
panelboards
switchboard is expandable
• Shopping Centers
• 75°C or 90°C wireway 1
to include a 75°C or • Institutions / Schools • User metering (refer to
90°C wireway, sub-main,
distribution, and fusible • Agricultural
• Main breaker maximum
400, 600, 800, or 1200A
Tab 9-Components, or
contact Eaton for more
1
switch metercenter cells for information)
a complete offering. Eaton’s
• Small buildings • Optional distribution cell, 1
sub-main cell with utility • Surge protection
Pow-R-Line CS Switchboard • Sports and entertainment
uses a space-saving design facilities
compartment, wire way,
pull boxes, fusible switch
devices (refer to Tab 1
to provide a smaller footprint 9-Components, or
meter center (FSMC)
than any other comparable contact Eaton for more
information)
1
switchboards in the market. • Convenient space for
utility CTs and PTs • Door-Over-Distribution 1
• Sealing screws, knurled • Special Colours
thumb screws and padlock 1
hasp • Cross-bus for future

• Standard enclosure
expansion
1
ratings of CSA Type 1; • Freestanding (18”D Only)
sprinklerproof optional • Fire pump breaker in
1
wireway (up to 400A)
• Nema 3R (Available only
for single cell or incoming
1
through wireway)
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 2-9
Low Voltage Switchboards and Switchgear
Pow-R-Line CS Switchboards

Enclosure Utility Metering Provisions: Special Dimensions and • Ability to add surge
1 Standard enclosure is CSA® • Meets all provincial and Configurations: protection and user
Type 1; sprinklerproof. municipal utility metering metering in the distribution
2 Nema Type 3R is optional, requirements
Eaton has the ability to offer
custom dimensions to suit
section
and available only for single • Utility ground studs • Optional door-over-
limited space requirements.
3 cell or incoming through available Special heights, special
distribution
wireway. Freestanding option Utility CTs and PTs can • Optional cross-bus for
• depths, widths, and corner
4 is available for 18” deep
enclosure.
be easily factory or field sections. future expansion
installed • 12” or 18” depth
5 Finish
• PUC Utility metering Standards and Certifications: • 48” width
options include: • CSA C22.2 No. 31
6 Standard:
• CTs-window type and
• CSA C22.2 No. 244 Pow-R-Line CS – 50X
bar type Distribution Cell:
CSA C22.2 No. 229
7 Galvanized steel tub. •
• External clamp-on CTs • Pow-R-Line 1A / 2A
All doors and covers have to verify meter chassis
a grey paint finish (ANSI 61)
8 using a modern, completely
• Up to four PTs in utility
compartment
• 50X distribution section

automated and continuously configurable for metered


9 monitored electrostatic • Neutral and ground
studs available
fusible switches (FSMC),
non-metered fusible
powdered coating.
switches (FDPW) or circuit
1 This continually monitored
system includes spray Breaker Accessories: breakers (not mixed)
de-grease and clean, spray Padlock hasp • Ability to add surge
1

rinse, iron phosphate spray • Visible windows
Additional Sections: protection and user
coating rinse, nonchemical metering in the distribution
1 seal, oven drying,


Electronic trip units
Shunt trip
Pow-R-Line CS - Wireway: section
electrostatic powder spray • Direct cable connection or • Optional door-over-
1 paint coating and oven curing. • Auxiliary switch wireway distribution
• Bell alarm • 75°C rated (standard) or • Optional cross-bus for
1 Optional: • Undervoltage release 90°C rated (optional) future expansion
• Factory bussing to • 12” or 18” depth
Assembly can be painted
1 any colour required by the Arc Flash Considerations: disconnect / circuit breaker • 30”W, 38”W, or 48”W
customer. Arc flash is an ongoing in main assembly depending on the feeder
1 concern in the electrical • 30”D X 30”W design
available for specific utility
device configuration and
industry. Eaton offers a amperage
Busbar System requirements
1 • Tin-plated aluminum
variety of solutions to reduce
the risk of arc flash such • 12”, 18”, or 30” depth Pow-R-Line CS – Sub-main cell
• Silver-flashed copper as the Arcflash Reduction (30”D available only at
1 • Tin-plated copper Maintenance System™ 30”W)
with 600A max. breaker:
• 80% Rated sub-main
in Eaton’s moulded-case • Width options:
1 Main Breaker: breakers. • 800A: 12”W,
disconnect, up to 600A
circuit breaker
Main breaker up to 1200A, 18”W, 24”W,
1 80% or 100% rated. Advanced Metering and 30”W × 30”D
• Includes reverse fed
breaker, utility metering
NNote: For 100% rating,
Communications: • 1200A: 24”W, or compartment and
1 incoming wireway required. Eaton has an extensive line of 30”W × 30”D outgoing lugs
powerful metering products, • PUC Utility metering
1 Customer Metering:
trip units, controllers and
Pow-R-Line CS – 1200A • Field wiring connection
gateways, that can be wired Main/40X Distribution Cell: compartment
1 Full line of Eaton
microprocessor-based
together in switchboards to
create an intelligent system • Service entrance rated • Optional door-over-
customer metering and and interface with building main compartment distribution
1 monitoring devices. management and SCADA • Main circuit breaker • Optional cross-bus for
Please refer to Tab 9— systems. (400, 600, 800 or 1200A) future expansion
1 Components, or contact
Provision for Future Devices
• Top or bottom, left or • 12” or 18” depth
Eaton for more information. right cable entry • 30” width
1 Chassis/Group Mounted: • 1200A, 100% rated main
Surge Protection Device Where a provision for future available when a wireway
1 (SPD): circuit protective devices is selected.
Standard integrated surge is required, the space and • 40X distribution section

1 protection device with a blank filler plate will be


supplied. Connections and
configurable for metered
fusible switches (FSMC),
integral disconnect is
mounting hardware are not non-metered fusible
1 available if required.
Tab 9—Components, included. switches (FDPW) or circuit
or contact Eaton for more breakers (not mixed)
1 information.

2-10 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca


Low Voltage Switchboards and Switchgear
Pow-R-Line CS Switchboards

Technical Data and Specifications


1
Rating Breaker Options Pow-R-Line CS
The service entrance panel bus is rated to 800A, 1200A, kA Value
2
Device Ampere Mounting
600V, three-phase, four-wire, 60Hz. Type
Main Breakers
Rating 240V 600V Height a
3
Interrupting Rating
• Maximum 65 kA at 600V
KD Frame 70–400 b 65–200 25–65 4X 4
LD Frame 300–600 65–200 25–50 6X
• Maximum 200 kA at 240V LG Frame 250–600 65–200 18–65 4X 5
MDL Frame 300–800 c 65–100 25–35 6X
FSMC Device Options Pow-R-Line CS NG Frame 320–800 65–200 25–65 6X 6
Ampere Single NG Frame 500–1200 65–200 25–65 6X d
Rating or Twin X Space a Branch Breakers 7
30/30 Twin 7X FD Frame 15–225 18–200 14–35 3X
30/60 Twin 7X JD Frame 70–250 65–200 18–35 3X 8
60/30 Twin 7X KD Frame 70–400 b 65–200 25–65 4X
60/60 Twin 7X LD Frame 300–600 65–200 25–50 6X 9
100/100 Twin 7X LG Frame 250–600 65–200 18–65 4X
200 Single 7X MDL Frame 300–800 c 65–100 25–35 6X 1
NG Frame 320–800 65–200 25–65 6X
NG Frame 500–1200 65–200 25–65 6X d 1
Branch Fusible Switches-Pow-R-Line CS 1
Cell Width
Device
Type 38-Inch 48-Inch
Mounting
Height a 1
30/30A twin
30/60A twin
Y
Y
Y
Y
4X
4X
1
Twin 30A, 60A or 100A FSMC Switch
60/60A twin
100/100A twin
Y
Y
Y
Y
4X
5X
1
200A (single or twin)
400A
Y
Y
Y
Y
6X
9X
1
600A
800A
Y
N
Y
Y
11X
11X
1
1200A N Y 15X
1
NNote
Single 200A FSMC Switch a 1X = 1-3/8 inch.
1
b Ampere ratings below 100A available with electronic trip unit only.
c Ampere ratings below 400A available with thermal-magnetic only.
1
d Only available for 1200A Cell

1
1
1
1
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 2-11
Low Voltage Switchboards and Switchgear
Pow-R-Line CS Switchboards

Dimensions (CSA Type 1 & Sprinklerproof)


1 Approximate Dimensions in Inches (mm)

2 Layout A: Top-Fed Pow-R-Line CS Main/PUC/21X Layout B: Bottom-Fed Pow-R-Line CS Main/PUC/21X


Distribution (800A Maximum at 600 Vac) Distribution (800A Maximum at 600 Vac)
3
4
5
6
7
8
9
1
1
1
1
1
Layout C: Top-Fed Pow-R-Line CS Main/PUC/21X Layout D: Bottom-Fed Pow-R-Line CS Main/PUC/21X
1 Distribution (1200A Maximum at 600 Vac) Distribution (1200A Maximum at 600 Vac)

1
1
1
1
1
1
1
1
1
1 b
b

1 NNote

1
a 1X = 1-3/8 inch
b Bottom-fed: Only 2 rows of FSMC metered switches. Top-fed: Only 1 row of FSMC metered switches

1 c For NEMA 3R dimensions consult your local Eaton sales representative

1
1
2-12 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Pow-R-Line CS Switchboards

Dimensions (CSA Type 1 & Sprinklerproof)


Approximate Dimensions in Inches (mm)
1
Layout E: Top-Fed Pow-R-Line CS Main/40X Layout F: Bottom-Fed Pow-R-Line CS Main/40X 2
Distribution (1200A Maximum at 600 Vac) Distribution (1200A Maximum at 600 Vac)
3
4
5
6
7
8
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 2-13
Low Voltage Switchboards and Switchgear
Pow-R-Line CS Switchboards

Dimensions
1 Approximate Dimensions in Inches (mm)

2 Layout A: Bottom-Fed Pow-R-Line CS with Incoming Wire Way Layout B: Top-Fed Pow-R-Line CS with Incoming Wire Way
and Main/PUC/21X Distribution (800A Maximum at 600 Vac) and Main/PUC/21X Distribution (800A Maximum at 600 Vac)
3
4
5
6
7
8
9
1
a

1
1 c c

1
1 Layout C: Bottom-Fed Pow-R-Line CS with Incoming Wire Way Layout D: Top-Fed Pow-R-Line CS with Incoming Wire Way and
and Main/PUC/21X Distribution (1200A Maximum at 600 Vac) Main/PUC/21X Distribution (1200A Maximum at 600 Vac)
1
1
1
1
1
1
1
1 a a

1 c c

1
1 NNote

1 a 1X = 1-3/8 inch.
b Width of cell is determined by breaker size and trip unit type. For fusible switches 800A and above, 48-inch-wide (1219.2 mm) cell is required. Contact Eaton for more information.

1 c 30”W X 30”D, rear aligned wireway available as an option.

1
1
1
2-14 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Pow-R-Line CS Switchboards

Dimensions (CSA Type 1 & Sprinklerproof)


Approximate Dimensions in Inches (mm)
1
Layout E: Bottom-Fed Pow-R-Line CS Main/40X Layout F: Top-Fed Pow-R-Line CS Main/40X 2
Distribution (1200A Maximum at 600 Vac) Distribution (1200A Maximum at 600 Vac)
3
4
5
6
7
8
9
1
a

1
c c

1
1
Additional Cells 1
50X Distribution Cell Top exit Sub-main cell Bottom exit Sub-main cell 1
(1200 Maximum at 600 Vac) with 600A maximum breaker with 600A maximum breaker
1
1
1
1
1
1
a
1
1
b
d e
1
NNote
a 1X = 1-3/8 inch.
1
b Width of cell is determined by breaker size and trip unit type. For fusible switches 800A and above, 44-inch-wide (1117.6 mm) cell is required. Contact Eaton for more information.
c 30”D X 30”W wireway available as an option.
1
d TBD
e TBD
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 2-15
Low Voltage Switchboards and Switchgear
Pow-R-Line CS Switchboards

1 Filler 1X Breaker To Fusible Transition, All Widths


Sub Panel
2 12X
18
Poles BAB
100 Amp QBHW
3 42 Max. GHB, GBH
20X Poles
4 400 Amp. Maximum Bus Rating

1P 1P 1X
5
2P 2P 2X
EHD,
6 225 Amp FDB, FD,
Max.
24-Inch (609.6 mm) Wide Box

HFD, FDC
7 3P 3P 3X FDE, HFDE(3P)

8
2P 2P 2X

9 225 Amp
Max. ED, EDH, EDC

1 3P 3P 3X

1 2 or 3P 3X 250 Amp JD, HJD, JDC


Max.
1 400 Amp Max. DK, KD, HKD, KDC, CKD, CHKD
2 or 3P 4X
600 Amp Max. LGE, LGH, LGU
1
600 Amp LD, HLD, CLD, CHLD, LDC
1
Load

2 or 3P 6X
Max.

1 100 Amp
2 or 3P 2 or 3P 3X FCL, FB-P
Max.
38-Inch (965.2 mm) Wide Box

1 250 Amp
3X
2 or 3P 2 or 3P Max. JD, HJD, JDC
1 400 Amp DK, KD, HKD, KDC,
4X
Max. CKD, CHKD
1 2 or 3P 2 or 3P
400 Amp
Max. LCL, LA-P
1 2 or 3P
6X
800 Amp MDL, HMDL,
Max. CMDL, CHMDL
1
2 or 3P 6X 1200 Amp
NGS, NGH, NGC
1 Max.

1
48-Inch (1219.2 mm) Wide Box

1 2 or 3P 800 Amp
6X
Max. NB-P
1
1200 Amp
NGSC, NGHC, NGCC
1 Max.

Breaker may be used as main.


1
1 Figure 2-4. Layout for Branch and Horizontally Mounted Main Devices — PRLCS
a BAB and QBHW breakers with shunt trips require one additional pole space, i.e., 1-pole is 2-pole size, 2-pole is 3-pole size, and 3-pole is 4-pole size.
1 b If panel contains only BAB or QBHW branch breakers, use a PRL1a panelboard.
c GHB and GBH breakers cannot be mixed on same subchassis as BAB, QBHW.
1 d If panel contains only GHB and GBH branch breakers, use a PRL2a panelboard.
e When only one single-pole breaker of the group is required on either side of chassis, the single-pole breaker space required changes from 1X to 2X.
1 f Minimum 38-inch (965.2 mm) wide box is required if optional #6 – 300 kcmil lug is required.

2-16 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca


Low Voltage Switchboards and Switchgear
Pow-R-Line CS Switchboards

Fusible to Breaker Transition 1


1X
Requires 1X Filler
2
30A 30A 4X 3
4
60A 60A 4X 5
6

38-inch (965.2 mm) Wide Box


200A
7
6X
Main or Branch Switch 8
9
100A 100A 5X 1
1
400A 9X 1
Branch Switch
1
600A 11X
1
Branch Switch
1
1
200A 200A 6X

1
400A
1
9X
Main or Branch 1
48 Inch (1219.2 mm) Wide Box

1
600A 11X
Main or Branch 1
1
800A 11X
Branch 1
1
1200A
Branch
15X
1
1
Figure 2-7. Branch and Horizontally Mounted Main Device Layout — PRLCS 1
● 400 and 600 ampere horizontally mounted feeder switches in 38-inch (965 mm) or 48-Inch (1219.2 mm) wide box.
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 2-17
Low Voltage Switchboards and Switchgear
Pow-R-Line CS Switchboards

This page intentionally left blank.


1
2
3
4
5
6
7
8
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2-18 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchboards

Contents
Pow-R-Line C Switchboard
1
Description Page
Standards and Certifications.................................... 3-21 2
Product Selection.................................................... 3-22
Technical Data and Specifications............................ 3-25 3
4
5
6
7
8
9
1
Pow-R-Line C Switchboards 1
Product Description Application Description Features, Benefits • A main moulded-case 1
Eaton Pow-R-Line C™ The Pow-R-Line C and Functions circuit breaker or a main
switchboards combine a switchboard is ideally suited fusible switch, within the 1
space-saving design with to commercial and industrial Main Devices sizes listed for panelboard
a modular construction and applications such as: • Magnum DS power circuit
design, can be included
in the panel-mounted
1
increased system ratings breakers, fixed-mounted
• Institutions and assembly in lieu of a
to provide economical and
dependable electrical system school boards or drawout, 800A to separate, individually 1
6000A at 600 Vac mounted unit
distribution and protection. • Office towers
• Health care facilities
maximum—100% rated
• Eaton fixed-mounted
• Ground fault protection on 1
• Retail facilities feeders if required
• Utility
moulded-case circuit
breakers up to 2500A, • Optional 10X 1
600 Vac maximum (1X = 1-3/8 inch) box
Solar applications

• Residential • Eaton fusible switches
available for meters, 1
protection and control
up to 1200A, 600 Vac
• Commercial
maximum
devices 1
• Industrial Pow-R-Line C designates
• Bolted pressure switches
up to 4000A a family of distribution 1
• Ground fault protection on switchboards, incorporating
main device if required design concepts that fit
the ever-increasing need
1
for applications on high
Distribution Devices short-circuit systems, while 1
• Moulded-case circuit retaining maximum safety
breakers fixed-mounted and convenience throughout 1
up to 2000A, 600 Vac the line.
maximum
Feeder circuit protective 1
• Moulded-case circuit
devices are an assembly
breakers drawout up to of units mounted on a 1
600A, 600 Vac maximum panelboard-type base
• Fusible switches up to (panelboard construction). 1
1200A, 600 Vac maximum Circuit protective devices
• Fusible switched meter are front accessible. 1
sockets (FSMC) up to
200A (48.00-inch-wide
cell only)
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 3-19
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchboards

Enclosure Standard Switchboard Height Provision for Busway Surge Protection Device (SPD)
1 Standard enclosure is CSA® The standard Pow-R-Line C Entrance and Exit Standard integrated surge
Type 1; sprinklerproof, Type 2, switchboard height is Busway connections to protection device with
2 3R are optional. Structures 90.00 inches (2286.0 mm). switchboard sections include integral disconnect is
and formed doors are made Custom height is cutout and drilling in the available if required. Please
3 of code gauge steel. available at 78.00 inches top of the switchboard with refer to Tab 9—Components
(1981.0 mm) high. riser connections from the or contact Eaton for more
4 Standard Finish Optional base channels
switchboard device or the
bus, up to the point where
information.

Grey paint finish (ANSI 61) 1.00 inch (25.4 mm), the bus duct enters the
5 using a modern, completely 1.50 inches (38.1 mm) switchboard. No connections Transition Cells
automated and continuously (standard option) or are furnished external to Transition structures are
6 monitored electrostatic 2.00 inches (50.8 mm) high the switchboard. required for connecting
powder coating. This available. Consult Eaton for switchboards to the
other options. In all transactions involving
7 continually monitored system
includes spray de-grease busway attached to switch-
secondary of power centre
transformer (dry or fluid
and clean, spray rinse, iron boards, it is essential that filled), motor control
8 phosphate spray coating
Provision for Future Devices
Chassis/Group Mounted
information regarding centres, and for other special
rinse, nonchemical seal, orientation of the busway switchboard configurations
9 oven drying, electrostatic
Where a provision for future
circuit protective devices
with respect to the front such as “L” or “U” shaped
powder spray paint coating of the switchboard be lineups. In some applications,
is required, the space and
1 and oven curing.
a blank filler plate will be
supplied to the coordinating
assembly plant.
an extra structure complete
with connections is required;
supplied. Connections and
1 Integral Base mounting hardware are NNote: Additional depth to the
switchboard may be required.
in others, where switchboard
depth and space permit, only
The ruggedly formed base not included. Optional
the connection conductors
1 greatly increases the rigidity insulated main bus is
On Pow-R-Line C are required. Refer to factory
of the structure, reduces available if required.
switchboards, a bus system for these applications.
1 the possibility of damage is used to connect the bus
during the installation of the Busbar System duct to the individually PLC Transfer Schemes
1 equipment, and is suitable for
rolling, jacking and handling.
Standard tin-plated aluminum mounted device, the main or
Advanced PLC-based transfer
or copper up to 3000A. sub-main switchboard bus,
A lifting angle is bolted and load shedding schemes
1 onto the top of the bus
Standard silver-plated copper
for 4000A to 6000A. Tin-
or the vertical main bus of
the panel-mounted circuit can be designed for various
compartment structure for protective device panels. applications such as data
plated copper also available.
1 increased strength.
Optional insulated main bus
centres, health care facilities
Side or rear hydro stub, and wastewater treatment
is available.
1 Front Accessible
collector bus, utility wireway
and transformer coordination
plants. HMI is optional for
touch screen monitoring
Standard bus and connectors
Front accessible switchboards to Eaton standard cross bus and control of incoming,
1 align at the rear, enabling
on all switchboards are
rated for use on systems are available; consult Eaton tie and feeder power
them to be placed against capable of producing up to factory for more information. circuit breakers. Contact
1 a wall (Pow-R-Line C front 50,000A rms symmetrical an Eaton sales engineer
accessible). If the main short-circuit current at the for more information.
Utility Metering Provisions
1 section is deeper than others,
due to physical size of the
incoming terminals.
• Meets all provincial and
main device, the necessary Increased bus short-circuit municipal utility metering Bus Duct Integration
1 off-set in lineup will occur in ratings equal to that of requirements Custom bus duct can be
front, and the main section connected switchboard • Utility ground studs integrated into switchboard
1 will be accessible from the devices, up to 200,000A rms available assemblies. Eaton can design
side as well as from the front. symmetrical, are available • Utility CTs and PTs and manufacture custom bus
1 Standard front accessible in most Pow-R-Line C can be easily factory or duct flanges to coordinate
switchboards will align at switchboards when approved field installed with the bus duct risers of
1 the front and the rear. main devices are installed.
Contact Eaton for more
a wide range of amperage.

information. CSA labeled Customer Metering


1 Rear Accessible
switchboard sections are Full line of Eaton
Eaton offers rear accessible marked with their applicable microprocessor-based
1 switchboards that align at the
front and the rear.
short-circuit rating. customer metering and
NNote: The short-circuit rating monitoring devices. Please
1 of the switchboard assembly refer to Tab 9—Components,
is limited to the interrupting or contact Eaton for more
1 capacity of the lowest rated
branch device.
information.

1
1
3-20 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchboards

Transformer and MCC Advanced Metering Standards and Certifications


Close-Coupling and Communications • CSA C22.2 No. 31
1
Close-couple dry-type, Eaton has an extensive line of CSA C22.2 No. 244
liquid-filled transformers powerful metering products,

• Seismic qualified to
2
and motor control centres trip units, controllers and
Zone 4 per IBC/CBC
(MCC) with standard gateways, that can be wired 3
switchboard configurations together in switchboards to
can be supplied. Transformer
unit substations and MCC
create an intelligent system
and interface with building
4
bus coordination would management and SCADA
create a compact lineup and systems. 5
minimization of installation
time by eliminating cable
Special Dimensions
6
installations. and Configurations
Eaton has the ability to offer
7
Integrated Transfer Switches custom dimensions to suit
Eaton automatic transfer limited space requirements. 8
switches (contactor, Special heights, special
moulded-case circuit breaker depths and widths, corner 9
or power circuit breaker sections, back-to-back, front
type, including optional access only (on deeper
switchboards that normally
1
bypass-isolation type)
can be integrated into a require rear access), rear
switchboard lineup. Electrical access and side access 1
and mechanical coordination configurations are available.
is ensured when transfer 1
switches are integrated into Arc Flash Considerations
the switchboard.
Arc flash is an ongoing
1
concern in the electrical
industry. Eaton offers a 1
variety of solutions to reduce
the risk of arc flash such 1
as the Arcflash Reduction
Maintenance System™ in 1
moulded-case or power
circuit breakers, safety
shutters in Magnum drawout
1
power circuit breakers, infra-
red viewing windows and 1
remote racking accessories.
1
1
1
1
1
1
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 3-21
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchboards

Product Selection
1 For complete application and pricing information, contact your local Eaton sales office.

2 Wireway Cell Layouts


3 Approximate Dimensions in Inches (mm)
Wireways are front access with rear and side access option, top or bottom incoming,
4 three- or four-wire, aluminum or copper, with bolted cover standard and front door optional.

5 Pow-R-Line C Switchboards Wireway Section Layout a

6
7
8
9 90.00 Wireway
(2286.0)
1
1
1
1 W
D

1 Wireway

1
Pow-R-Line C Wireway Cells
1 Cell Depth Cell Width (W)

1 Ampere
Rating
18.00
(457.2)
24.00
(609.6)
30.00
(762.0)
36.00
(914.4)
60.00 to 90.00
(1524.0 to 2286.0)
18.00
(457.2)
24.00
(609.6)

1 800
1200













1 2000
2500










 

1 3000
3200









1 4000   

NNote
1 a 91.50 inches (2324.1 mm) high with 1.50 inch (38.1 mm) optional base channel.
Specific municipality code designs available. Consult Eaton for more information.

1 Consult Eaton for CSA enclosure rating.


Custom 78.00 inches (1981.2 mm) high wireways available. Consult Eaton for custom height information.
Custom lug sizing and spacing available. Consult Eaton for more information.
1
1
1
1
1
1
1
3-22 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchboards

Main and Utility Cell Layouts


Approximate Dimensions in Inches (mm) 1
With copper or aluminum main bus; system incoming by cable or bus duct; 2
available for indoor or outdoor structures.

Pow-R-Line C Switchboards Main and Utility Section Layouts a


3
4
5
GFR Metering
Compartment
6
Main/
Sub-Main
Main/
Sub-Main
Main/
Sub-Main
7
Breaker Device Device

90.00
8
90.00 90.00 90.00
(2286.0) (2286.0) (2286.0) (2286.0)
9
Utility CT/PT
Compartment
Utility CT/PT
Compartment
Utility CT/PT
Compartment
Utility CT/PT
Compartment 1
1
38.00/48.00 b 38.00/48.00 b 38.00/48.00 b 38.00/48.00 b
1
(965.2/1219.2) (965.2/1219.2) (965.2/1219.2) (965.2/1219.2)
18.00/24.00 18.00/24.00 18.00/24.00 18.00/24.00 1
(457.2/609.6) (457.2/609.6) (457.2/609.6) (457.2/609.6)

Layout A Layout B Layout C Layout D


1
Top-mounted main/sub-main Top-mounted main/sub-main Top-mounted main/sub-main Top-mounted main/sub-main
bolted pressure switch with breaker with utility metering device with utility device with horizontal 1
utility metering compartment compartment and vertical metering compartment. metering compartment and
and ground fault relay. metering compartment. utility metering compartment.
1

Standard Pow-R-Line C Main and Utility Cells—Main Devices


1
Ampere Rating Main Device Frame Layout A Layout B Layout C Layout D 1
100–2500 Moulded-case circuit breaker F, J, K, L, M, N, R   
400–1200 Fusible switch FDP   1
1200–2000 Fusible switch Pringle switch  
2500–3000 c Fusible switch Pringle switch   1
3000 c Fusible switch Pringle switch  
800–1200 c Power circuit breaker Fixed mounted    1
1200–3200 c Power circuit breaker Fixed mounted   
4000–6000 d Power circuit breaker Fixed mounted   1
800–1200 d Power circuit breaker Drawout  
1200–3200 d Power circuit breaker Drawout   1
4000–6000 d Power circuit breaker Drawout
1
 

NNote
a 91.50 inches (2324.1 mm) high with 1.50 inch (38.1 mm) optional base channel.
b Main devices up to and including 3200A require 38.00-inch-wide (965.2 mm) cells; main devices 4000–6000A require 48.00-inch-wide (1219.2 mm) cells. 1
c 24.00 inch (609.6 mm) depth required.
d Additional depth required. Consult Eaton for more information. 1
All layouts shown are top fed. Consult Eaton for top and bottom incoming.
Custom 78.00 inches (1981.2 mm) high main utility available. Consult Eaton for custom heights.
Consult Eaton for copper or aluminum bussing, CSA enclosure rating, and horizontal and vertical metering.
1
Power Xpert® Metering is not compatible with vertical metering layout (Layout B).
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 3-23
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchboards

Main and Half-High Distribution Cell Layouts


1 Approximate Dimensions in Inches (mm)
2 With copper or aluminum main bus; system incoming by cable or bus duct;
available for indoor or outdoor structures.
3
Pow-R-Line C Switchboards Main and Half-High Distribution Section Layout a

4
5
6
b Main/
18X/22X
7 Chassis
Sub-Main
Device

8
90.00 90.00

9 (2286.0) (2286.0)

1 Main/ b
18X/22X
Sub-Main Chassis
Device
1
1 38.00 38.00
(965.2) (965.2)
1 24.00 24.00
(609.6) (609.6)
1 Bottom-mounted main/ Top-mounted main/
sub-main breaker with sub-main breaker with
1 distribution chassis. distribution chassis.

1
Pow-R-Line C Main and Half-High Cells—
1 Main Devices
Ampere Main Main/ Distribution
1 Rating Device Frame Utility Chassis
400–2500 Moulded-case K, L, M, N, R Main 18X
1 circuit breakers
400–2500 Moulded-case K, L, M, N, R Main 22X
1 400–1200
circuit breakers
Fusible switch FDP Main 18X

1 400–1200 Fusible switch FDP Main 22X


NNote
1 a 91.50 inches (2324.1 mm) high with 1.50 inch (38.1 mm) optional base channel.
b 1X = 1-3/8 inch.

1 Consult Eaton for CSA enclosure rating.


Consult Eaton for horizontal and vertical metering.
Consult Eaton for top or bottom incoming and additional layouts.
1
1
1
1
1
1
1
3-24 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchboards

Distribution Cell Layouts


Approximate Dimensions in Inches (mm)
1
Distribution boards are offered in copper or aluminum, three- or four-wire, 2
with cable in option available.
Pow-R-Line C Switchboards Distribution Section Layout a 3
4
5
6
50X
b 7
Vertical
90.00
(2286.0)
Panel
Space
8
for
Devices 9
1
1
38.00/48.00 c
(965.2/1219.2)
1
18.00/24.00
(457.2/609.6)
1
50X Distribution Chassis
1
Standard Pow-R-Line C Distribution Cells—Branch Devices 1
Ampere Rating Frame Feeder Device Distribution Size
1
100–1600 F, J, K, L, M, N d, R e Moulded-case circuit breaker 18X / 22X / 50X
20–600 JG, LG Drawout MCCB f 18X / 22X / 50X 1
30/60 Single Fusible switch 18X / 22X / 50X
100 Single/twin Fusible switch 18X / 22X / 50X 1
200 Single/twin Fusible switch 18X / 22X / 50X
400 Single Fusible switch 18X / 22X / 50X 1
600 Single Fusible switch 18X / 22X / 50X
800 Single Fusible switch 18X / 22X / 50X 1
1200 Single Fusible switch 18X / 22X / 50X
1
Commercial Metering Switchboard 1
Eaton offers Fusible Switch Metering Centres (FSMC) for commercial metering applications.
Please refer to Tab 3—Commercial Metering for more information. 1
NNote 1
a 91.50 inches (2324.1 mm) high with optional base channel.
b 1X = 1-3/8 inch. 1
c Width of cell may require 48.00 inches (1219.2 mm) due to cable sizing or other features; consult Eaton for more information.
d For cable sizing 750 kcmil and greater, 48.00-inch-wide (1219.2 mm) cell required. 1
e Copper bussing and 50 kAIC only.
f Refer to Tab 5—Pow-R-Line C Switchboards with Drawout Moulded-Case Circuit Breaker, for more information. 1
Consult Eaton for CSA enclosure rating.
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 3-25
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchboards

1 Filler 1X Breaker To Fusible Transition, All Widths


Sub Panel
2 12X
18
Poles BAB
100 Amp QBHW
3 42 Max. GHB, GBH
20X Poles
4 400 Amp. Maximum Bus Rating

1P 1P 1X
5
2P 2P 2X
EHD,
6 225 Amp FDB, FD,
Max. HFD, FDC
7 3P 3P 3X FDE, HFDE(3P)

8
2P 2P 2X

9 225 Amp
Max. ED, EDH, EDC

1 3P 3P 3X

1 2 or 3P 250 Amp JD, HJD, JDC


38-Inch (965.2 mm) Wide Box

3X
Max.
1 400 Amp Max. DK, KD, HKD, KDC, CKD, CHKD
2 or 3P 4X
600 Amp Max. LGE, LGH, LGU
1
600 Amp LD, HLD, CLD, CHLD, LDC
1
Load

2 or 3P 6X
Max.

1 100 Amp
2 or 3P 2 or 3P 3X FCL, FB-P
Max.
1
3X 250 Amp
2 or 3P 2 or 3P Max. JD, HJD, JDC
1
4X
400 Amp DK, KD, HKD, KDC,
1 2 or 3P 2 or 3P Max. CKD, CHKD
400 Amp
LCL, LA-P
1 2 or 3P
6X Max.
800 Amp MDL, HMDL,
Max. CMDL, CHMDL
1
2 or 3P 6X 1200 Amp
NGS, NGH, NGC
1 Max.

1
48-Inch (1219.2 mm) Wide Box

1 2 or 3P 800 Amp
6X
Max. NB-P
1
1200 Amp
NGSC, NGHC, NGCC
1 Max.

Breaker may be used as main.


1
1 Figure 2-4. Layout for Branch and Horizontally Mounted Main Devices — PRLC
a BAB and QBHW breakers with shunt trips require one additional pole space, i.e., 1-pole is 2-pole size, 2-pole is 3-pole size, and 3-pole is 4-pole size.
1 b If panel contains only BAB or QBHW branch breakers, use a PRL1a panelboard.
c GHB and GBH breakers cannot be mixed on same subchassis as BAB, QBHW.
1 d If panel contains only GHB and GBH branch breakers, use a PRL2a panelboard.
e When only one single-pole breaker of the group is required on either side of chassis, the single-pole breaker space required changes from 1X to 2X.
1 f Minimum 38-inch (965.2 mm) wide box is required if optional #6 – 300 kcmil lug is required.

3-26 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca


Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchboards

Fusible to Breaker Transition 1


1X
Requires 1X Filler
2
30A 30A 4X 3
4
60A 60A 4X 5
6

38-inch (965.2 mm) Wide Box


200A
7
6X
Main or Branch Switch 8
9
100A 100A 5X 1
1
400A 9X 1
Branch Switch
1
600A 11X
1
Branch Switch
1
1
200A 200A 6X

1
400A
1
9X
Main or Branch 1
48 Inch (1219.2 mm) Wide Box

1
600A 11X
Main or Branch 1
1
800A 11X
Branch 1
1
1200A
Branch
15X
1
1
1
Figure 2-7. Branch and Horizontally Mounted Main Device Layout — PRLC
▲ Fusible switch may be used as horizontal main.
1
● 400 and 600 ampere horizontally mounted feeder switches in 38-inch (965 mm) or 48-Inch (1219.2 mm) wide box. 400 and 600 ampere
horizontally mounted main switches only in 44-inch (1117.6 mm) wide box. For vertically mounted main see Page 2-19 for sizing.
1
Note: See Page 2-19 for MLO or Neutral and Vertically Mounted Main space requirements. 1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 3-27
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchboards

This page intentionally left blank.


1
2
3
4
5
6
7
8
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3-28 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Commercial Metering Switchboards

Contents
Commercial Metering Switchboard
1
Description Page
Standards and Certifications.................................... 4-30 2
Product Selection.................................................... 4-30
Dimensions.............................................................. 4-30 3
4
5
6
7
8
9
1
Commercial Metering Switchboards 1
Product Description Features, Benefits Main Bus Enclosure 1
Eaton commercial metering and Functions • Single-bolt bus joints • Freestanding, front
switchboards use space- The commercial metering up to 3000A for ease accessible design (rear 1
saving design with modular switchboard has a free- of installation at accessible where required)
construction, incorporating standing switchboard shipping splits • Structures are ANSI 61 1
metering sections with construction; it is factory • 50 kA bracing standard; light grey baked enamel,
tenant feeder circuits using
meter sockets to meet
assembled and fully
integrated.
65, 85, 100 kA optional code gauge steel with
formed doors / removable
1
• Tin-plated aluminum bus
local utility or customer back sheets; other colours
requirements. All meter
is standard with optional
silver-plated copper optional 1
sockets and associated Metering Unit / Metering Cell
available • Standard enclosures
feeder devices are • Twin-mounted 30A,
• Provision for future are CSA® Type 1; 1
completely factory prewired 60A and 100A metering sprinklerproof optional
extension is provided
and shipped ready for the
installation of the meters.
switches available
as standard • Split back sheets for 1
• Single-mounted 200A
• Available with a bus ease of handling
Eaton offers a number of
metering switches available
• Metering switches are
connected, incoming • Single-cell shipping splits 1
options for commercial Pow-R-Line C™ main cell available as standard for
metering switchboards. type FSMC (fusible switch
meter sockets), suitable to
or a separate, standalone ease of handling 1
These include assemblies main lugs only structure
accept revenue grade, self-
that meet utility requirements
for globe type watthour contained meters • Channel sills optional 1
meters and electronic tenant • Various meter base jaw
metering switchboards. options available to meet 1
all requirements—most
Application Description common is Star (Y) type, 1
seven jaw, suitable for
Commercial multi-metering
applications such as:
four-wire systems up to
347/600V
1
• Shopping centres • Switch jaws are spring
reinforced to firmly
1
• Office buildings
grip blades
• Condominium complexes
• Maximum quantity of
1
• Apartment buildings
six FSMC twin or single
units can be installed 1
in each 90.00 inch
(2286.0 mm) high 1
x 48.00-inch-wide
(1219.2 mm) enclosure 1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 4-29
Low Voltage Switchboards and Switchgear
Commercial Metering Switchboards

Standards and Certifications Product Selection Dimensions


1 • CSA C22.2 No. 229 Approximate Dimensions in Inches (mm)
CSA C22.2 No. 31 FSMC Device Options
2 •
• CSA C22.2 No. 244 FSMC Layout
Ampere Single
3 Rating or Twin X Space a
30/30 Twin 7X

4 30/60 Twin 7X
60/30 Twin 7X
5 60/60 Twin 7X
100/100 Twin 7X
6 200 Single 7X
NNot
7 a 1X = 1-3/8 inch.

8 90.00
(2286.0)

9
1
1
1 18.00/24.00
48.00
(457.2/609.6)
1 (1219.2)

1
1
1 FSMC Units Installed in
Pow-R-Line C Switchboard

1 Twin 30A, 60A or 100A FSMC Switch

1
1
1
1
Single 200A FSMC Switch
1
1
1
1
1
1
1
1
1
4-30 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Integrated Facility Switchboards

Contents
Integrated Facility Switchboards
1
Description Page
Features, Benefits 2
and Functions...................................................... 5-32
Options.................................................................... 5-32 3
Standards and Certifications.................................... 5-32
Product Selection.................................................... 5-33 4
Technical Data and Specifications............................ 5-41
5
6
7
8
9
1
Integrated Facility Switchboards 1
Product Description The service entrance Other associated equipment Application Description 1
Eaton Integrated Facility equipment can be integrated can also be integrated into Eaton Integrated Facility
Switchboards™ (IFS™) utilizes with multiple lighting the assembly, including Switchboards are designed 1
the modular Pow-R-Line C™ and appliance branch dry-type distribution to meet specific needs for:
switchboard design to panelboards into a compact
front accessible group-
transformers, time clock
space, lighting control, • Retail stores
1
integrate traditionally
mounted switchboard. electronic controls, surge Commercial offices
separate electrical distribution
and control equipment Where multiple switchboards protection devices, metering,

• High rise buildings
1
into a single space-saving or panelboards are used automatic transfer switches
factory assembled and in the same electrical and energy monitoring
• Correctional facilities 1
room as a conventional devices. Depending upon • Agricultural facilities
connected package.
distribution system, the
integrated design significantly
the application, other user-
defined equipment such as a
• Industrial facilities 1
• Hospitals / health
reduces equipment space subsystem control package
requirements, as well as may also be incorporated.
care facilities 1
• Educational facilities
minimizes installation time
and costs. Whether the application is 1
a multi-site prototype or a
single application, integrated 1
switchboards offer time and
space-saving features. 1
1
1
1
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 5-31
Low Voltage Switchboards and Switchgear
Integrated Facility Switchboards

Features, Benefits Space Savings Options


1 and Functions The space-saving
Busbar System
Standard bus in the • Automatic transfer
switchboard installation
2 Front Accessible provides additional usable
switchboards is tin-plated
aluminum or silver-plated •
switches
Breakers
Integrated facility floor space. For example: copper; optional tin-plated
3 switchboards are front • Retail stores—floor space copper available.
• Metering
accessible and align at the • Dry-type transformers
for sales
4 rear, enabling them to be
• Offices—additional Short-Circuit Rating
• Enclosed control
placed against a wall. Most • Seismic construction
storage, cubicle
5 switchboards align at the
front and the rear. If the main • Health care—additional
Standard bus and connectors
on all switchboards are rated
• Surge protection devices
work area for use on systems capable • UPS
section is deeper than others
6 due to physical size of the • Retrofits—ability to fit of producing up to 65 kA • HVAC control
main device, the necessary existing rooms rms symmetrical short-circuit • Harmonic blocking filter
7 off-set in line-up will occur current at the incoming • Power factor correction
in the front, and the main Site Construction Savings terminals. • Generator Quick Connect
8 section will be accessible Timely installation of the Short-circuit ratings up to
from both the front and electrical system typically is 200 kA symmetrical are Standards and Certifications
9 the side. a key element on the critical available when used with • CSA® C22.2 No. 31
path for any project. approved devices. Contact
CSA C22.2 No. 244
1 Standard Switchboard Height
Along with the time to
Eaton for more information. •
• Factory wired panelboards
Switchboard height is install the equipment, other and dry-type distribution
1 90.00 inches (2286.0 mm). expenses include the time to Bus Duct Integration transformers meet CSA
handle all of the loose pieces Applications such as condo, C22.2 No. 31 and the
1 Switchboard Shipping Splits of equipment arriving on a job
site and ensuring it reaches
commercial office towers Canadian Electrical Code
The sections can be and health care facilities may • Zone 4 Construction (IBC/
the proper trades person.
1 shipped as specified by
With Eaton Integrated Facility
require bus duct. Custom
bus duct flanges can be
CBC Seismic Qualified)
the customer to meet
Switchboards, one piece designed and manufactured
1 specific requirements.
of equipment is typically to coordinate with bus duct
For retrofit applications, shipped to a job site virtually risers of a wide range of
1 single-piece switchboard eliminating these issues. amperages. The bus duct can
structures can be shipped to even be directly integrated
The equipment may also
1 facilitate movement through
be used for temporary into the switchboard,
limited access doorways, etc. eliminating the need for bus
power on job sites, further
1 reducing construction plugs and therefore creating
a more compact footprint.
Factory Interconnections expenses and times.
1 Where interconnections
are required within the IFS, Lighting Control
1 power cabling is factory
Eaton lighting control
installed and sized per the
panelboards with remote
Canadian Electrical Code.
1 control breakers can be
installed in IFS assemblies.
1
1
1
1
1
1
1
1
1 Traditionally Mounted Equipment

1 Integrated Facility Switchboard

5-32 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca


Low Voltage Switchboards and Switchgear
Integrated Facility Switchboards

Product Selection
1
Integrated Facility Switchboard Applications
2
Electrical Room With and Without IFS—Plan View
3
Panel L1 Panel L2 4
Main
IFS
Switchboard
5
Transformer
Integrated Facility
Switchboard Solution
6
7

Telephone
8
Telephone Panel P3 Panel P2 Panel P1

9
Traditional Electrical Room IFS Electrical Room
1
Optimized IFS Layout—Front View 1
Main RD
1
Breaker
Customer P1 P3 L1
1
Metering Feeder
Breaker
Section 1
Utility SPD Dry-Type
Metering
Section
P2
Distribution
L2
1
Transformer
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 5-33
Low Voltage Switchboards and Switchgear
Integrated Facility Switchboards

Approximate Dimensions in Inches (mm)


1
Integrated Facility Switchboards Distribution Section Layout
2 Eaton Pow-R-Line panelboard integration—factory wired from feeder device in adjacent section(s) to panelboards.
Standard features include lockable trim doors and factory-mounted overcurrent devices.
3
Style 1 and 2 Integrated Facility Switchboards Distribution Section Layout
4
W
5 3.00
(76.2)
3.00
(76.2)

6
3.00
7 D (76.2)
Conduit Area
12.00
(304.8)
8 Cell “A”

9 90.00 90.00
Floor Plan
Cell “C” Style 1 and 2 Sections
(2286.0) (2286.0)
1 W
3.00 3.00
1 Cell “B” (76.2) (76.2)

1 3.00
D (76.2) Conduit Area 3.00
1 D D
(76.2)
W W
1
IFS Style 1 Section IFS Style 2 Section Floor Plan
1 Style 2 Section with Blank Steel Backpan Only

1 IFS Style 1 Allowable Configurations (Select One “Panelboard Type” per Panelboard “Cell”)
Main Maximum Branch Allowable Width (W) Depth (D)
1 Panel
Cell
Panelboard
Type
Maximum
Vac Rating
Device
Type
Main Rating
Amperes
Circuit Panelboard
Ampere Range Modifications Standard Optional Standard Optional
Section
Height

1 IFS Style 1 Section


A Pow-R-Line 1a 240 MLO 600 15–100 ab 26.00 (660.4) 30.00 (762.0) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)

1 Breaker 225 20.00 (508.0) 26.00 (660.4)


30.00 (762.0)
Pow-R-Line 2a 600Y/347 MLO 600 15–100 ab 26.00 (660.4) 30.00 (762.0) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)
1 Breaker 225 20.00 (508.0) 26.00 (660.4)
30.00 (762.0)
1 Pow-R-Command™ 240 MLO 225 15–100 ab 20.00 (508.0) 26.00 (660.4) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)
480Y/277 30.00 (762.0)
1 Blank steel
backpan c
— None — — d 20.00 (508.0) 26.00 (660.4)
30.00 (762.0)
18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)

1 B Pow-R-Line 1a 240 MLO


Breaker
600
225
15–100 ab 26.00 (660.4)
20.00 (508.0)
30.00 (762.0)
26.00 (660.4)
18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)

30.00 (762.0)
1 Pow-R-Line 2a 600Y/347 MLO 600 15–100 ab 26.00 (660.4) 30.00 (762.0) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)

1 Breaker 225 20.00 (508.0) 26.00 (660.4)


30.00 (762.0)
Pow-R-Command 240 MLO 225 15–100 ab 20.00 (508.0) 26.00 (660.4) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)
1 480Y/277 30.00 (762.0)
Blank steel — None — — d 20.00 (508.0) 26.00 (660.4) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)
1 backpan c 30.00 (762.0)
NNote
1 a Copper main lugs, ground bar circuit breaker handle lockoff devices, nameplates, 200% rated neutral through 400A, permanent circuit numbers, directory frames, shunt trip breakers, through-feed
lugs to panel immediately above or below.

1 b If panel sizing with non-interchange main is 48.00 inches (1219.2 mm) high or less, the panel will fit in a half section. If it is 72.00 inches (1828.8 mm) high, you must use a full section.
If it is 60.00 inches (1524.0 mm) high, contact Eaton for structure dimensions. (One exception is PRL 1a/2a with 400A MLO and 42 circuits, which will fit in half section.)
c Possible uses: HVAC, dimming, contactors, A/V equipment and data rack equipment. Contact Eaton for details.
1 d Galvanized steel backpan provided for customer specified equipment. Contact Eaton for details.

5-34 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca


Low Voltage Switchboards and Switchgear
Integrated Facility Switchboards

Approximate Dimensions in Inches (mm)


1
Style 1 and 2 Integrated Facility Switchboards Distribution Section Layout

W
2
3.00
(76.2)
3.00
(76.2) 3
4
3.00
D (76.2)
Conduit Area
12.00
(304.8)
5
Cell “A”
6
90.00 90.00
Cell “C”
Floor Plan
Style 1 and 2 Sections
7
(2286.0) (2286.0)

W 8
3.00 3.00
Cell “B” (76.2) (76.2) 9
3.00 1
D (76.2) Conduit Area 3.00
D D
(76.2)
1
W W
1
IFS Style 1 Section IFS Style 2 Section Floor Plan
Style 2 Section with Blank Steel Backpan Only
1
IFS Style 2 Allowable Configurations (Select One “Panelboard Type” per Panelboard “Cell”)
1
Main Maximum Branch Allowable Width (W) Depth (D)
Panel
Cell
Panelboard
Type
Maximum
Vac Rating
Device
Type
Main Rating
Amperes
Circuit Panelboard
Ampere Range Modifications Standard Optional Standard Optional
Section
Height 1
IFS Style 2 Section
C Pow-R-Line 1a 240 MLO 600 15–100 ab 26.00 (660.4) 30.00 (762.0) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)
1
Pow-R-Line 2a 600Y/347
Breaker
MLO
400
600 15–100 ab 26.00 (660.4) 30.00 (762.0) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)
1

Pow-R-Line 3a 600
Breaker
MLO
400
600 15–125 ab 26.00 (660.4) 30.00 (762.0) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)
1
Breaker 400
1
Pow-R-Command 480Y/277 MLO 400 15–100 ab 26.00 (660.4) 30.00 (762.0) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)
Breaker 225 1
Blank steel — None — — d 20.00 (508.0) 26.00 (660.4) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)

NNote
backpan c 30.00 (762.0)
1
a Copper main lugs, ground bar circuit breaker handle lockoff devices, nameplates, 200% rated neutral through 400A, permanent circuit numbers, directory frames, shunt trip breakers, through-feed
lugs to panel immediately above or below.
1
b If panel sizing with non-interchange main is 48.00 inches (1219.2 mm) high or less, the panel will fit in a half section. If it is 72.00 inches (1828.8 mm) high, you must use a full section.
If it is 60.00 inches (1524.0 mm) high, contact Eaton for structure dimensions. (One exception is PRL 1a/2a with 400A MLO and 42 circuits, which will fit in half section.) 1
c Possible uses: HVAC, dimming, contactors, A/V equipment and data rack equipment. Contact Eaton for details.
d Galvanized steel backpan provided for customer specified equipment. Contact Eaton for details. 1
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 5-35
Low Voltage Switchboards and Switchgear
Integrated Facility Switchboards

Approximate Dimensions in Inches (mm)


1
Style 3 and 4 Integrated Facility Switchboards Distribution Section Layout
2
3
4 Cell “F”
W
5 Cell “D” 3.00
(76.2)
3.00
(76.2)

6
90.00 90.00 3.00
7 (2286.0) (2286.0) D (76.2) Conduit Area 3.00
(76.2)

8
Cell “E”
9 Floor Plan Style 3 Section
with Blank Space in Cell “E”

1 Bottom Entry Conduit Space not


Recommended with Transformer
D D in Cell “E” or “F” (Style 3 or 4)
1 W W

1 IFS Style 3 Section IFS Style 4 Section

1 IFS Style 3 Allowable Configurations (Select One “Panelboard Type” per Panelboard “Cell”)
Main Maximum Branch Allowable Width (W) Depth (D)
1 Panel Panelboard Maximum Device Main Rating Circuit Panelboard Section
Cell Type Vac Rating Type Amperes Ampere Range Modifications Standard Optional Standard Optional Height

1 IFS Style 3 Section


D Pow-R-Line 1a 240 MLO 600 15–100 a 26.00 (660.4) 30.00 (762.0) 24.00 (609.6) — 90.00 (2286.0)
1 Breaker 225
Pow-R-Line 2a 600Y/347 MLO 600 15–100 a 26.00 (660.4) 30.00 (762.0) 24.00 (609.6) — 90.00 (2286.0)
1 Breaker 225
Pow-R-Line 3a 600 MLO 600 15–125 ab 26.00 (660.4) 30.00 (762.0) 24.00 (609.6) — 90.00 (2286.0)
1 Breaker 400
Pow-R-Line C 600 MLO 800 15–600 a 26.00 (660.4) 36.00 (914.4) 24.00 (609.6) — 90.00 (2286.0)
1 switchboard
chassis
Breaker 600 30.00 (762.0)
MLO or 800 15–600 a 36.00 (914.4) — 24.00 (609.6) — 90.00 (2286.0)
1 Breaker
Pow-R-Command 240 MLO 225 15–100 a 26.00 (660.4) 30.00 (762.0) 24.00 (609.6) — 90.00 (2286.0)
1 Blank steel
480Y/277
— None — — c 26.00 (660.4) 30.00 (762.0) 24.00 (609.6) — 90.00 (2286.0)
backpan
1 NNote

1 a Copper main lugs, ground bar circuit breaker handle lockoff devices, nameplates, 200% rated neutral through 400A, permanent circuit numbers, directory frames, shunt trip breakers, through-feed
lugs to panel immediately above or below.
b If panel sizing with non-interchange main is 48.00 inches (1219.2 mm) high or less, the panel will fit in a half section. If it is 72.00 inches (1828.8 mm) high, you must use a full section.
1 If it is 60.00 inches (1524.0 mm) high, contact Eaton for structure dimensions. (One exception is PRL 1a/2a with 400A MLO and 42 circuits, which will fit in half section.)
c Galvanized steel backpan provided for customer specified equipment. Contact Eaton for details.
1 Select one “Panelboard Type” or one “Blank Steel Backpan” and either one “Transformer” or one “Blank Space” per “Cell.“

1
1
1
1
1
5-36 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Integrated Facility Switchboards

Approximate Dimensions in Inches (mm)


1
Style 3 and 4 Integrated Facility Switchboards Distribution Section Layout
2
3

Cell “F”
4
W
Cell “D” 3.00
(76.2)
3.00
(76.2)
5
6
90.00 90.00 3.00
(2286.0) (2286.0) D (76.2) Conduit Area 3.00
(76.2)
7
8
Cell “E”
Floor Plan Style 3 Section 9
with Blank Space in Cell “E”
Bottom Entry Conduit Space not
Recommended with Transformer 1
D D in Cell “E” or “F” (Style 3 or 4)
W W
1
IFS Style 3 Section IFS Style 4 Section
1
IFS Style 3 and 4 General Purpose Dry-Type Distribution Transformers 1
Panel Panelboard Temperature kVA Full Cap Taps Allowable Width (W) Depth (D) Section
Cell Type Rise Windings Range FCAN FCBN Modifications Standard Optional Standard Optional Height 1
IFS Style 3 Section
E ab Transformer c 150°C only d Aluminum 15–45 4–2.5% 2–2.5% a 26.00 (660.4) — 24.00 (609.6) — 90.00 (2286.0)
1
150°C only d Aluminum 75 4–2.5% 2–2.5% 30.00 (762.0) — 24.00 (609.6) — 90.00 (2286.0)
1
a

115°C Aluminum 112.5 4–2.5% 2–2.5% a 36.00 (914.4) — 24.00 (609.6) — 90.00 (2286.0)
IFS Style 4 Section
Fa Transformer c 150°C Aluminum 150 4–2.5% 2–2.5% a 36.00 (914.4) — 30.00 (762.0) — 90.00 (2286.0)
1
225 4–2.5% 2–2.5% 44.00 (1117.6) — 36.00 (914.4) — 90.00 (2286.0)
1
a

NNote
a Copper windings, 115°C, 80°C, K-Factor, low sound are available options but may change dimensions.
b Either one F Frame or K Frame circuit breaker can be included in any transformer section to be used as a disconnect.
1
c General purpose CSA C802.2 Energy Efficient.
d Contact Eaton for other temperature rise transformers and special requirements.
1
1
1
1
1
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 5-37
Low Voltage Switchboards and Switchgear
Integrated Facility Switchboards

Approximate Dimensions in Inches (mm)


1
Style 5 and 6 Integrated Facility Switchboards Distribution Section Layout
2
W
3 3.00
(76.2)
3.00
(76.2)

4 a
22X 3.00

5 Cell “G”
Distribution
Chassis
D (76.2)
Conduit Area
12.00
(304.8)
Cell “H”
6
90.00 90.00
7 (2286.0) (2286.0) Floor Plan
Style 5 and 6 Sections

8 22X
a

Distribution Cell “G”


9 Chassis
Cell “H”

1
D D
1 W W

IFS Style 5 Section IFS Style 6 Section


1
1 IFS Style 5 and 6 Allowable Configurations (Select One “Panelboard Type” per Panelboard “Cell”)
Main Maximum Branch Allowable Width (W) Depth (D)
1 Panel
Cell
Panelboard
Type
Maximum
Vac Rating
Device
Type
Main Rating
Amperes
Circuit Panelboard
Ampere Range Modifications Standard Optional Standard Optional
Section
Height

1 IFS Style 5 and 6 Sections


G Pow-R-Line 1a 240 MLO 600 15–100 bc 26.00 (660.4) 30.00 (762.0) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)

1 Breaker 225
Pow-R-Line 2a 600Y/347 MLO 600 15–100 bc 26.00 (660.4) 30.00 (762.0) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)

1 Breaker 225
Pow-R-Line 3a 600 MLO 600 15–125 bc 26.00 (660.4) 30.00 (762.0) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)
1 Breaker 400
Pow-R-Command b 240 MLO 225 15–100 b 26.00 (660.4) 30.00 (762.0) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)
1 H Pow-R-Line C
480Y/277
600 MLO 800 15–600 b 26.00 (660.4) 30.00 (762.0) 18.00 (457.2) 24.00 (609.6) 90.00 (2286.0)
switchboard 36.00 (914.4)
1 chassis
Breaker
Breaker
600
800 15–600 b 36.00 (914.4) — 24.00 (609.6) — 90.00 (2286.0)

1 NNote
a 1X = 1-3/8 inch.

1 b Copper main lugs, ground bar circuit breaker handle lockoff devices, nameplates, 200% rated neutral through 400A, permanent circuit numbers, directory frames, shunt trip breakers,
through-feed lugs to panel immediately above or below.

1 c If panel sizing with non-interchange main is 48.00 inches (1219.2 mm) high or less, the panel will fit in a half section. If it is 72.00 inches (1828.8 mm) high, you must use a full section.
If it is 60.00 inches (1524.0 mm) high, contact Eaton for structure dimensions. (One exception is PRL 1a/2a with 400A MLO and 42 circuits, which will fit in half section.)

1
1
1
1
1
1
1
5-38 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Integrated Facility Switchboards

Approximate Dimensions in Inches (mm)


1
Style 7 Integrated Facility Switchboards Distribution Section Layout
2
W
3
Cell Cell 4
“I” “J” D
5
Floor Plan Style 7 Section
6
There is no Bottom Entry
Conduit Space with
Transformer in Cell “J”
7
Cell “K”
8
9
IFS Style 7 Section 1
IFS Style 7 Panelboard Over Dry-Type Transformer (Select One “Panelboard Type” per Panelboard “Cell”)
1
Panel Panelboard Maximum
Main
Device
Maximum
Main Rating
Branch
Circuit
Allowable
Panelboard
Width (W) Depth (D)
Section
1
Cell Type Vac Rating Type Amperes Ampere Range Modifications Standard Optional Standard Optional Height
IFS Style 7 Section
1
I Pow-R-Line 1a 240 MLO
Breaker
400 15–100 a 36.00 (914.4) — 24.00 (609.6) — 90.00 (2286.0)
1
Pow-R-Line 2a 600Y/347 MLO
Breaker
400 15–100 a 36.00 (914.4) — 24.00 (609.6) — 90.00 (2286.0)
1
J Pow-R-Line 1a 240 MLO 400 15–100 a 36.00 (914.4) — 24.00 (609.6) — 90.00 (2286.0)
1
Breaker
Pow-R-Line 2a 600Y/347 MLO 400 15–100 a 36.00 (914.4) — 24.00 (609.6) — 90.00 (2286.0) 1
Breaker
Pow-R-Line 3a 600 MLO 400 15–225 ab 36.00 (914.4) — 24.00 (609.6) — 90.00 (2286.0) 1
Breaker

IFS Style 7 General Purpose Dry-Type Distribution Transformers


1
Panel Panelboard Temperature kVA
Full Cap Taps
Allowable
Width (W) Depth (D)
Section 1
Cell Type Rise Windings Range FCAN FCBN Modifications Standard Optional Standard Optional Height
IFS Style 7 Section 1
K Transformer cd 150°C only e Aluminum 15–75 4–2.5% 2–2.5% f 36.00 (914.4) — 24.00 (609.6) — 90.00 (2286.0)
115°C Aluminum 112.5 4–2.5% 2–2.5% f 36.00 (914.4) — 24.00 (609.6) — 90.00 (2286.0) 1
NNote
a Copper main lugs, ground bar circuit breaker handle lockoff devices, nameplates, 200% rated neutral through 400A, permanent circuit numbers, directory frames, shunt trip breakers,
1
through-feed lugs to panel immediately above or below.
b If panel sizing with non-interchange main is 48.00 inches (1219.2 mm) high or less, the panel will fit in a half section. If it is 72.00 inches (1828.8 mm) high, you must use a full section. 1
If it is 60.00 inches (1524.0 mm) high, contact Eaton for structure dimensions. (One exception is PRL 1a/2a with 400A MLO and 42 circuits, which will fit in half section.)
c Either one F Frame or K Frame circuit breaker can be included in any transformer section to be used as a disconnect. 1
d General purpose CSA C802.2 Energy Efficient.
e Contact Eaton for other temperature rise transformers and special requirements. 1
f Copper windings, 115°C, 80°C, K-Factor, and harmonic mitigating transformers are available options but may change dimensions.

1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 5-39
Low Voltage Switchboards and Switchgear
Integrated Facility Switchboards

Approximate Dimensions in Inches (mm)


1
Integrated Facility Switchboards ATS Section Layout
2 Eaton Pow-R-Line panelboard and integrated wall-mounted ATS (non-bypass)—factory wired from feeder devices in adjacent sections.
Standard features include lockable trim doors and factory-mounted overcurrent devices.
3
Style 8, 9, 10 and 11 Integrated Facility Switchboards ATS Section Layout
4
5
6
a
22X
7 Cell “O”
Distribution
Cell “L” Chassis

8
90.00 90.00 90.00 90.00
9 (2286.0) (2286.0) Cell “N” (2286.0) (2286.0)

1
22X a
Cell “M” Cell “P”
1 Distribution
Chassis

1
D D D D
1 W W W W

1 IFS Style 8 Section IFS Style 9 Section IFS Style 10 Section IFS Style 11 Section

1 IFS Style 8, 9, 10 and 11 Contactor-Based, Non-Bypass Transfer Switches (Select One “ATS Type” per ATS “Cell”)
1 Maximum Main Rating
Width
20.00 26.00 30.00 36.00
Depth
18.00 24.00
Standard Terminals
Load Side, Normal Neutral
ATS Cell Vac Rating Amperes (508.0) (660.4) (762.0) (914.4) (457.2) (609.6) and Standby Source Connection
1 IFS Style 8, 9, 10 and 11 Sections

1 L/M/O/P 480 40–100       (1) #14–2/0 (3) #14–1/0


600 40–100       (1) #6–250 kcmil (3) #14–1/0
1 480 150–200       (1) #6–250 kcmil (3) 1/0–250 kcmil
600 150–200       (1) #6–250 kcmil (3) 1/0–250 kcmil
1 480 225–400       (2) 3/0–250 kcmil (6) 250–500 kcmil
(1) 3/0–600 kcmil
1 N 480 40–100       (1) #14–2/0 (3) #14–1/0
600 40–100       (1) #6–250 kcmil (3) #14–1/0
1 480 150–200       (1) #6–250 kcmil (3) 1/0–250 kcmil
600 150–200       (1) #6–250 kcmil (3) 1/0–250 kcmil
1 480 225–400       (2) 3/0–250 kcmil (6) 250–500 kcmil
(1) 3/0–600 kcmil
1 600 225–400    (2) 3/0–250 kcmil (6) 250–500 kcmil
(1) 3/0–600 kcmil
1 600–1200    (4) 1/0–750 kcmil (12) 1/0–750 kcmil
480 600–1200    (4) 1/0–750 kcmil (12) 1/0–750 kcmil
1 NNote
a 1X = 1-3/8 inch.
1 All amperages available in three- and four-pole.

1
1
1
5-40 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Integrated Facility Switchboards

Approximate Dimensions in Inches (mm)


1
IFS Style 8, 9, 10 and 11 Breaker-Based, Non-Bypass Transfer Switches
(Select One “ATS Type” per ATS “Cell”) 2
Width Depth
Frame Maximum Main Rating 26.00 30.00 36.00 18.00 24.00 3
ATS Cell Size Vac Rating Amperes (660.4) (762.0) (914.4) (457.2) (609.6)
IFS Style 8, 9, 10 and 11 Sections 4
L/M/O/P F 600 30–150     
240 30–200 5
N F 600 30–150     
240 30–200 6
K, L, M 600/240 225–600   
Na 600/240 800–1200    7
NNote
a Please consult Eaton for N size breaker frame. 8
All amperages available in two-, three- and four-pole.
9
Technical Data and Specifications 1
Contactors / Motor Control
1
Consult Eaton for complete application.
1
Seismic Construction
Zone 4 seismic is optional. 1
Metering 1
Metering can be installed in the following standard cells:
1
• Blank steel backpan (20, 26, 30, 36 inches wide)
• Pow-R-Line 4 chassis (minimum 36 inches wide, 1
22X spacing)
Metering products: 1


IQ 100 (130, 140, 150)
IQ 200 (250, 260)
1
• PXM (2250, 2260, 2270, 4000, 6000, 8000) 1
• PXG (400e, 600e, 800e)
• IQ 35M 1
• Non-Eaton products
Consult Eaton for more information. 1
1
1
1
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 5-41
Low Voltage Switchboards and Switchgear
Integrated Facility Switchboards

This page intentionally left blank.


1
2
3
4
5
6
7
8
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
5-42 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchboards with Drawout Moulded-Case Circuit Breaker

Contents
Pow-R-Line C Switchboard with Drawout Moulded-Case Circuit Breakers
1
Description Page
Standards and Certifications.................................... 6-44 2
Product Selection.................................................... 6-45
Technical Data and Specifications............................ 6-45 3
Dimensions.............................................................. 6-45
4
5
6
7
8
9
1
Pow-R-Line C™ Switchboards with Drawout Moulded-Case Circuit Breaker 1
Product Description Application Description The base cassette is Drawout Cassette 1
Eaton drawout moulded- Drawout moulded-case circuit designed to accept the The drawout cassette
case circuit breakers are breaker switchboards are drawout cassette that contains the breaker and is 1
installed in switchboards in ideal for applications such as: contains the breaker. The group-mounted. The cassette
a group-mounted manner.
• Data centres
loadside feeder conductors
are also part of the base
incorporates a viewing 1
Breakers use drawout window and an external
Health care facilities cassette, allowing the racking port. The viewing
cassettes and are three-
pole with ratings from 20A

• Process industry loadside feeder conductors window allows personnel to
1
to 600A. The breakers are to remain with the base visually inspect the breaker
inserted and removed via a
• Institutions cassette when the breaker is status and to see whether 1
• Laboratories removed without removing the breaker is connected to
mechanical system similar
to other drawout designs • Critical load applications the loadside conductors. or disconnected from the 1
associated with switchgear; The base cassette contains a bus. The window exposes
however, these breakers
are horizontally mounted in
Features, Benefits drawout racking mechanism, the Connected/Disconnected
position indicator on the base
1
and Functions a Connected/Disconnected
a traditional switchboard. cassette. The external racking
Feeder devices are also Enclosures
position indicator and a pull-
port allows access to the 1
apart terminal block base
front accessible and front racking mechanism to draw
connected.
CSA® Type 1, sprinklerproof
optional. Please consult Eaton
(used for connections to the
breaker accessories). out the breaker. 1
for other enclosure types. The drawout cassette
Group-mounted drawout
moulded-case circuit breakers
NNote: Per industry practice,
all power to the board section contains handles attached 1
include Eaton JG and LG must be disconnected at its to the deadfront to help
breaker families and include
Base Cassette
source before working on any easily remove the breaker. 1
standard thermal-magnetic The base cassette is electrical equipment. The cassette also contains
trip units or optional Eaton permanently factory mounted
to the switchboard’s chassis. Safety features include
a pigtail wiring harness, 1
310+ electronic trip units. which is factory-wired from
The lineside connections finger-safe connections to
use bus connectors and are the moulded-case circuit
the breaker accessory ports
and contains a pull-apart
1
factory connected to the breaker drawout cassette and terminal block that attaches
switchboard’s vertical bus. a mechanism system that the permanently mounted 1
will not allow the breaker to female terminal block located
be connected or removed on the base cassette. 1
while the breaker is in the External connections on
energized, ON, position. the secondary side of the 1
terminal block are provided
by the installer.
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 6-43
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchboards with Drawout Moulded-Case Circuit Breaker

The drawout cassette Surge Protection Devices (SPDs) When the Eaton Arcflash Zone selective interlocking
1 employs two breaker Eaton SPDs are available. Reduction Maintenance provides increased system
families—the JG and the A moulded-case circuit System is enabled, the protection and can reduce
2 LG with standard thermal- breaker is provided as a resulting reduced arc-flash arc-flash risk by allowing the
magnetic trip unit. Optional lineside disconnect for energy allows for reduced breaker closest to the fault
3 310+ electronic trip units
offer ampere ratings from
the SPD. Refer to Tab 9— PPE, which improves worker
comfort and mobility. With
to trip without any preset
time delays. This is achieved
Components—or contact
20A to 250A on the JG and the Arcflash Reduction by selecting and setting the
4 100A to 600A on the LG.
Eaton for more information.
Maintenance System set trip unit equipped with the
at 2.5X or 4.0X, it reduces zone selective interlocking
5 Breaker Options
Optional Infrared (IR) incident energy levels to allow option. The hardwired
Viewing Windows PPE Category 0 for currents connection between the
6 • Electronic trip units
• Infrared viewing windows
Infrared windows are an of 2.5X or 4.0X the breaker trip units sends a restraining
available option on both ampere rating or greater. The signal upstream, allowing the
7 for the lineside and
loadside connections
the JG and LG families of
single-mounted drawout
initial setting of each Arcflash
Reduction Maintenance
breaker closest to the fault
to act instantaneously. Zone
• Shunt trips moulded-case circuit breaker System trip unit is determined selective interlocking reduces
8 • Auxiliary contacts
cassettes. Infrared windows by completing a power stress on the distribution
can be located to view the system analysis to assess system and can reduce arc-
9 • Bell alarm
• Zone selective interlocking
lineside and/or loadside available fault current at the flash risk by isolating faults
connections. circuit breaker. Based on that without time delays.
1 • Arcflash Reduction analysis, the Maintenance
mode protection settings are
Maintenance System™ Arcflash Reduction Standards and Certifications
defined, achieving a reduced
1 The JG and LG families Maintenance System
level of arc-flash energy. The
• CSA C22.2 No. 31
of drawout breakers are The Eaton Arcflash Reduction Maintenance mode is then • CSA C22.2 No. 244
1 available in either a single Maintenance System provides activated by adjusting the trip
group-mounted design or reduced levels of incident unit’s instantaneous setting to
1 a high-density, twin group-
mounted design where two
arc-flash energy when put
in the Maintenance mode.
desired Maintenance mode
levels that are determined by
breakers occupy the same The Arcflash Reduction
1 vertical space. Maintenance System is
the power analysis.
available on the LG family of
1 Short-Circuit Rating
drawout MCCBs, combining Electronic Trip Units With Zone
Selective Interlocking (ZSI)
the Arcflash Reduction
1 The short-circuit current
rating of the switchboard is
Maintenance System with
the Digitrip 310+ electronic
Unlike power air circuit
breakers, moulded-case
determined by the short- trip unit and allowing for the circuit breakers do not offer
1 circuit current rating of the ability to place the trip unit in the ability to turn off the
lowest rated overcurrent Maintenance mode to reduce instantaneous trip settings.
1 device in the switchboard. potential arc-flash energy. As a result, the coordination
This is done by a dedicated between one breaker and
1 Busbar System instantaneous sensing circuit another could compromise
with settings of 2.5 and 4.0 selectivity (breaker closest
Standard tin-plated copper
1 bus and silver-plated copper.
times the current rating of
the trip unit. This dedicated
to the fault opening first).
Zone selective interlocking
analog sensing circuit delivers is designed to mitigate
1 Metering breaker clearing times that are selectivity issues with
A full line of Eaton customer faster than instantaneous by moulded-case circuit breakers.
1 metering is available. All eliminating microprocessor
Both the JG and LG families
options offered in Eaton’s processing latencies. This
of moulded-case circuit
1 standard bolt-on switchboard provides superior arc flash
breakers offer zone selective
product are also available reduction to competing
interlocking as an option.
1 with the Pow-R-Line drawout systems that simply lower
the standard instantaneous
moulded-case circuit breaker
pickup set point.
1 switchboard. Refer to Tab 9—
Components—or contact
Eaton for more information.
1
1
1
1
1
6-44 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchboards with Drawout Moulded-Case Circuit Breaker

Product Selection Technical Data and Specifications


Eaton Pow-R-Line C switchboard: 1
Standard Adjustable Thermal-Magnetic
Single Group-Mounted
Feeder Trip Units
• Maximum 4000A rating 2
• Rated at 240, 480 and 600 Vac
250A JG Frame 600A LG Frame
• Maximum interrupting ratings: 3
70A 250A • 200 kAIC at 240 Vac
90A 300A • 100 kAIC at 480 Vac 4
100A 350A • 65 kAIC at 600 Vac
125A 400A 5
150A 500A
175A 600A Short-Circuit Current Ratings
6
200A — Short-Circuit Rating kA
225A — Maximum Breaker
Ampere Rating
Breaker
Frame
Symmetrical by Vac
240V 480V 600V
7
250A —
250 JGS 85 35 18 8
JGH 100 65 25
Optional 310+ Electronic Trip Units
Twin Group-Mounted
Feeder
250A JG Frame 600A LG Frame
JGC 200 100 35 9
JGU 200 150 50
20A 100A 600 LGS 85 35 25 1
25A 125A LGH 100 65 35
30A 150A LGC 200 100 50 1
40A 175A LGU 200 150 65
45A 200A 1
50A 225A
Optional Accessories
70A 250A
Position a
1
80A 300A
90A 350A
Accessory Left Right
1
100A 400A Alarm contact (Make/Break) — 

110A 450A Auxiliary switch (1A/1B) — 


1
125A 500A Auxiliary switch (2A/2B) — 

150A 600A Auxiliary switch and alarm contact —  1


175A — Shunt trip (specify voltage)  —

200A — Undervoltage release mechanism  — 1


225A —
250A — 1
Dimensions
Approximate Dimensions in Inches (mm) 1
Drawout Group-Mounted “X” Space Factors b
1
Breaker Family Type
Group-Mounted
Chassis “X” Space
Width 1
and Configuration Required 38.00 (965.2) 48.00 (1219.2)
JG family, single mount 7X  
1
JG family, dual/twin mount
LG family, single mount
7X
9X




1
LG family, dual/twin mount 9X — 
1
NNote
a Only one accessory per position.
b 1X = 1-3/8 inch.
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 6-45
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchboards with Drawout Moulded-Case Circuit Breaker

Layout for Branch and Horizontally Mounted Main Devices—PRLC


1
Instructions
2 Determine box size by locating all main and feeder devices in your panel. The width of box is determined by the maximum box
size shown for each device.
3
4
5
6 Feeder Only
Single Drawout 7X
250A
Max.
JGS, JGH, JGC

7
8
9 Main or Feeder
38 Inch (965.2 mm) Wide Box

600A
Single Drawout 9X LGS, LGH, LGC
Max.
1
1
1 Main Only 6X
1200A
Max. NGS a, NGH a, NGC a
Fixed Mount
1
1
Feeder Only Feeder Only 250A
48 Inch (1219.2 mm) Wide Box

JGS, JGH, JGC


1 Dual Drawout Dual Drawout
7X
Max.

1
1
Main or Feeder Main or Feeder 600A
1 Dual Drawout Dual Drawout 9X
Max.
LGS, LGH, LGC

1
1
1 a 100% rated breaker.

1
b Optional 750 kcmil terminal requires 44-inch (1117.6 mm) wide box.
c Contact Eaton for availability.

1
1
1
1
1
1
1
1
6-46 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchboards with Drawout Moulded-Case Circuit Breaker

This page intentionally left blank.


1
2
3
4
5
6
7
8
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 6-47
Low Voltage Switchboards and Switchgear
Generator Connection Assemblies

Contents
1 Typical Generator Quick Connect Assembly

Description Page
2 Generator Quick Connect Switchboards.............
Standards and Certifications............................... 7-49
3 Product Selection............................................... 7-49
Technical Data and Specifications....................... 7-49
4 Dimensions........................................................ 7-49
Customer Service Termination Enclosure................ 7-50
5 Roll-Up Generator Quick Connect Assembly........... 7-52
6
7
8
External View Internal View
9
1
1 Generator Quick Connect Switchboards
1 Product Description Application Description Features, Benefits Safer and More Reliable
The Eaton Generator Quick The Generator Quick Connect and Functions • Reduces the potential
1 Connect Switchboard is Switchboard can be applied safety hazards associated
an engineered assembly in both new and retrofit Reduced Downtime with connecting the
1 designed to allow safe applications. (Speed of Connection) mobile generator to
and reliable connection of The Generator Quick Connect the facility’s electrical
The switchboard supports system under lost power
1 a mobile generator to the
facility’s electrical system. all market segments and
Switchboard is ready for
immediate connection. conditions
applications, such as: • Eliminates the safety
Once the Quick Connect
1 The Eaton Quick Connect
• Commercial facilities Switchboard is installed: hazards of generator
includes Cam-type
cables lying in the path of
1 receptacles, standard
mechanical lugs, a dedicated
• Institutions and
school boards
• A permanent connection customers or employees
point for temporary mobile
generator-service disconnect, Retail buildings
1 and a manual key-interlock

• Industrial facilities •
power is established
No additional field Reduced Emergency Costs
transfer scheme. The modifications to the The costs associated with
1 switchboard provides a
• Residential facilities
internal switchboard are temporarily connecting
quick and safe supply of • Health care facilities
required to connect the mobile generators, such as
1 emergency power to parts of • Wastewater treatment
facilities
generator cables modifying switchboards,
the electrical power system making physical modifications
• Modifications to the
1 that are not covered by the
emergency power system;
• Data centres
facility’s physical structure to buildings, and routing
to accommodate generator cables to connect the mobile
it can also back up existing
1 generators. cables (e.g., drilling holes generator, are eliminated or
greatly reduced.
in walls) is not required
1 Loads connected to the
Generator Quick Connect
• No routing of cables
through doorways,
Switchboard can be safely
1 transferred to an alternative
windows, hallways or
staircases is required
power source.
1
1
1
1
1
1
7-48 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Generator Connection Assemblies

Decreased Utility Dependency Standards and Certifications Technical Data and Specifications
The Quick Connect • CSA® C22.2 No. 31
1
Switchboard allows the Generator Quick Connect kW Ratings (Rated up to 600V)
2
a
facility to switch between
kW (Maximum) Rating c
utility feed and generator
feed, without relying on utility
Ampere
80% Rated Generator
Disconnect Breaker
100% Rated Generator
Disconnect Breaker 3
for disconnect service. Rating b 600V 208V 600V 208V
Product Selection 400 266 92 332 115
4
Standard Generator Quick
600
800
399
531
138
184
498
664
173
230
5
Connect Assembly
• Standard ratings available
1200
1600
797
1063
276
368
996
1329
345
461
6
up to 2000A (80% rated)
or 1600A (100% rated)
Generator Quick Connect Main Breaker Ratings
7
• Detailed operating
instructions mounted
on front cover
Breaker Maximum Interrupting Rating (kA) 8
Cam Lock Receptacles with Frame Ampere Rating 240V 600V
Colour-Coded Generator Connections • The Generator Service
Disconnect is a CSA
N-Frame 1200 65, 100 25, 35, 65 9
R-Frame 1600 125, 200 50, 65
approved circuit breaker
key interlocked with the R-Frame 2000 (80% rated) 125, 200 50, 65 1
service disconnect
• Accessories include Generator Quick Connect Schematic
1
ground fault, shunt trip,
auxiliary contacts and 1
alarms
• Colour-coded Cam-type Inside
Switchboard
Building Wall Generator Quick Connnect
1
Bottom Flip-Up Cover for plug receptacles for easy
Easy Access to Incoming Lugs
or Cam Lock Receptacles
connection to generator 1
• Mechanical lugs are Generator
Portable

1
Cable
provided for alternate Generator Power

method of connecting
generator cables
• Standard enclosure is
Underground Conduit 1
CSA Type 1; sprinklerproof,
Type 2, 3R are optional 1
• Pow-R-Line C™ Dimensions
construction similar Approximate Dimensions in Inches (mm)
1
to Eaton’s standard
switchboard Standard structures are 24.00 inches (762.0 mm) deep, by 1
30.00 inches (762.0 mm) wide by 90.00 inches (2286.0 mm) high.
Custom Generator Quick
Connect Assembly CSA Type 3R enclosures are equipped with a 13.00-inch 1
(330.0 mm) front structure extension.
• Accommodates ratings
greater than 1600A
1
NNote
(100% rated) or 2000A
(80% rated); consult Eaton
a 50 kAIC standard bus bracing. 1
b Standard ratings up to 1600A; for higher amperages, consult Eaton.
for more information
• Custom integration into
c Calculated using the following: kW (max.) = [(V*A*1.73*PF)/1000]*(breaker rating) 1
with PF (power factor) equaling 0.8.
switchboard lineups are
available; consult Eaton 1
for more information
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 7-49
Low Voltage Switchboards and Switchgear
Generator Connection Assemblies

Contents
1 Customer Service Termination Enclosure

Description Page
2 Generator Quick Connect Switchboards.................. 7-48
Customer Service Termination Enclosure............
3 Catalogue Number Selection.............................. 7-51
Product Selection............................................... 7-51
4 Technical Data and Specifications....................... 7-51
Roll-Up Generator Quick Connect Assembly........... 7-52
5
6
7
8
9
1
1 Customer Service Termination Enclosure
1 Product Description Features, Benefits Busbar System Standards and Certifications
Eaton Customer Service and Functions • Standard aluminum
1 Termination Enclosures bussing
• CSA C22.2 No. 31
(CSTEs) are the splitter Enclosure • Optional copper bussing;
1 connection assemblies Eaton CSTEs are made please consult Eaton for
between utility transformers with code gauge steel more information
1 and the customer’s main
distribution for specific
construction. Standard
enclosures are CSA Type 3R, Utility Metering
utility applications.
1 complete with ventilation
and a padlocking handle. Utility CTs and PTs are
installed by others. Optional
1 Both pad-mounted and remote meter assemblies
wall-mounted designs available—EATON #M501.
1 are available.
Terminations
1 • Load mechanical lugs
to suit #2–500 kcmil
1 • Provisions for utility two-
hole compression lugs—
1 on line side

1
1
1
1
1
1
1
1
1
7-50 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Generator Connection Assemblies

Catalogue Number Selection


1
CSTE 4 1 M W 2
Ampere Rating Design
3
Volts Connection
4 = 400A
6 = 600A 1 = 120/240 M = Utility
P = Pad-mount
W = Wall-mount 4
8 = 800A 2 = 120/208 metering
10 = 1000A
12 = 1200A
6 = 347/600 S = Splitter 5
16 = 1600A
20 = 2000A 6
25 = 2500A
30 = 3000A
7
NNot
Please use catalogue number selection for purchasing. 8
9
Product Selection
Approximate Dimensions in Inches (mm) 1
Wall-Mounted CSTE Available as Splitter Only 1
Ampere Rating Width Depth Height
1
400 30.00 (762.0) 10.00 (254.0) 30.00 (762.0)
600–1000 36.00 (914.4) 16.00 (406.4) 46.00 (1168.4) 1
1200–2000 46.00 (1168.4) 23.00 (584.2) 48.00 (1219.2)
2500–4000 60.00 (1524.0) 30.00 (762.0) 60.00 (1524.0) 1
Wall-Mounted CSTE Available as Splitter with Utility Metering Provisions 1
Ampere Rating Width Depth Height
400 30.00 (762.0) 10.00 (254.0) 30.00 (762.0)
1
600–1000 36.00 (914.4) 16.00 (406.4) 46.00 (1168.4)
1200–1600 46.00 (1168.4) 23.00 (584.2) 48.00 (1219.2)
1
2000–4000 60.00 (1524.0) 30.00 (762.0) 60.00 (1524.0)
1
Pad-Mounted CSTE Available as Splitter Only or Splitter with
Utility Metering Provisions 1
Ampere Rating Width Depth Height
400–1000 36.00 (914.4) 16.00 (406.4) 52.00 (1320.8)
1
1200–1600 46.00 (1168.4) 23.00 (584.2) 48.00 (1219.2)
1
2000–4000 60.00 (1524.0) 30.00 (762.0) 60.00 (1524.0)

1
Technical Data and Specifications
1
Ratings
• 120/240 Vac 1
• 208Y/120V
• 600Y/347V 1
• Ampere ratings of 400, 600, 800, 1000, 1200, 1600, 2000,
2500, 3000A (for ratings above 3000A, consult Eaton) 1
• Assembly short-circuit rating: 50,000A rms symmetrical
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 7-51
Low Voltage Switchboards and Switchgear
Generator Connection Assemblies

Contents
1 Roll-Up Generator Quick Connect Assembly

Description Page
2 Generator Quick Connect Switchboards.................. 7-48
Customer Service Termination Enclosure................ 7-50
3 Roll-Up Generator Quick Connect Assembly......
Catalogue Number Selection.............................. 7-53
4 Product Selection............................................... 7-53
Technical Data and Specifications....................... 7-53
5
6
7
8
9
1
1 Roll-Up Generator Quick Connect Assembly
1 Product Description Features, Benefits Busbar System Standards and Certifications
Eaton’s Roll-Up Generator and Functions • Standard aluminum
1 Quick Connect Assembly bussing
• CSA C22.2 No. 31
is the connection assembly Enclosure • Optional copper bussing,
1 between the temporary Eaton Roll-Up Generator please consult Eaton for
generator and the customer’s Quick Connect Assemblies more information
1 main distribution or transfer
switch.
are made with code gauge
steel construction. Standard Terminations
1 Roll-Up Generator Quick enclosure is CSA Type 3R
with a padlocking handle; • Accommodates
Connect Assemblies are mechanical and
Type 4X is optional.
1 splitter connection points
housing generator connection
compression lugs
Both pad-mounted and • Provisions for two-hole
points and load connection
1 points.
wall-mounted designs
are available.
compression lugs or
cam lock receptacles
1
1
1
1
1
1
1
1
1
1
1
1
7-52 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Generator Connection Assemblies

Catalogue Number Selection


1
RUG 4 1 PC 2
Ampere Rating Design
3
Volts
4 = 400A
6 = 600A 1 = 120/240
P = Pad-mount
W = Wall-mount 4
8 = 800A 2 = 120/208 PC = Pad-mount (cam lock)
10 = 1000A
12 = 1200A
6 = 347/600 WC = Wall-mount (cam lock) 5
16 = 1600A
20 = 2000A 6
25 = 2500A
30 = 3000A
7
NNot
Please use catalogue number selection for purchasing. Catalogue number selection is for
standard CSA Type 3R enclosure. Consult Eaton for CSA Type 4X enclosures.
8
9
Product Selection
Approximate Dimensions in Inches (mm) 1
1
Wall-Mounted Roll-Up Generator Quick Connect Assembly Available as
Splitter Connection with or without Cam Locks 1
Ampere Rating Width Depth Height
600–1000 36.00 (914.4) 16.00 (406.4) 46.00 (1168.4) 1
1200–1600 46.00 (1168.4) 23.00 (584.2) 48.00 (1219.2)
2000–4000 60.00 (1524.0) 30.00 (762.0) 60.00 (1524.0) 1
Pad-Mounted Roll-Up Generator Quick Connect Assembly Available as 1
Splitter Connection without Cam Locks
Ampere Rating Width Depth Height 1
600–1000
1200–1600
36.00 (914.4)
46.00 (1168.4)
16.00 (406.4)
23.00 (584.2)
58.00 (1473.2)
60.00 (1524.0)
1
2000–4000 60.00 (1524.0) 30.00 (762.0) 72.00 (1828.8)
1
Pad-Mounted Roll-Up Generator Quick Connect Assembly Available as
Splitter Connection with Cam Locks 1
Ampere Rating Width Depth Height
1
600–1600 46.00 (1168.4) 23.00 (584.2) 72.00 (1828.8)
2000–4000 60.00 (1524.0) 30.00 (762.0) 72.00 (1828.8) 1
Technical Data and Specifications 1
Ratings 1
• 120/240 Vac
• 208Y/120V 1
• 600Y/347V
• Ampere ratings of 600, 800, 1000, 1200, 1600, 2000, 2500,
1
3000A (for ratings above 3000A, consult Eaton)
• Assembly short-circuit rating: 50,000A rms symmetrical
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 7-53
Low Voltage Switchboards and Switchgear
Generator Connection Assemblies

This page intentionally left blank.


1
2
3
4
5
6
7
8
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
7-54 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchgear

Contents
Pow-R-Line C Switchgear
1
Description Page
Standards and Certifications.................................... 8-58 2
Optional Breaker Accessories.................................. 8-58
Dimensions.............................................................. 8-60 3
4
5
6
7
8
9
1
Pow-R-Line C Switchgear 1
Product Description Features, Benefits • Standard 100 kA short- Structure Features 1
Eaton’s Pow-R-Line C™ and Functions circuit bus bracing Standard finish: Grey
switchgear is an assembly • Lower installation and • Optional 150 and 200 kA paint finish (ANSI 61) using 1
of metal enclosures, each maintenance costs short-circuit bus bracing a modern, completely
housing drawout or fixed • Higher interrupting ratings • Optional insulating barriers automated and continuously 1
mounted low voltage power and withstand ratings to isolate the cable monitored electrostatic
powder coating. This
circuit breakers. • Better coordination compartment from the
bus compartment continually monitored
1
The Canadian switchgear is capability system includes spray
particularly designed for the • Increased tripping
• Both indoor and outdoor
walk-in and non-walk-in de-grease and clean, spray 1
construction market such sensitivity rinse, iron phosphate spray
enclosures; standard
as data centres, hospitals,
retail, office buildings and
• Enhanced safety measures enclosure is CSA Type coating spray rinse, non- 1
• Higher quality, reliability 1; optional enclosures chemical seal, oven drying,
commercial applications. In
addition to power breakers,
and maintainability are CSA Type 2, 3R; electrostatic powder spray
paint coating and oven curing.
1
the switchgear includes • Communications and sprinklerproof optional
control and measuring power quality monitoring • Full range of safety Integral base: The ruggedly 1
devices such as relays, and measuring capabilities solutions dealing with formed base greatly increases
instruments, meters, Pow-R-Line C switchgear
arc flash hazards by using
Eaton Arcflash Reduction
the rigidity of the structure,
reduces the possibility of
1
instrument transformers and provides:
Maintenance System damage during the installation
control power transformers.
• 100% rated, fully features of the equipment, and is 1
selective protection suitable for rolling, jacking
Application Description
• Integral microprocessor-
Maximum ratings for and handling. A lifting angle 1
Switchgear is used to Pow-R-Line C switchgear are is bolted onto the top of the
based breaker tripping
protect, control and monitor
low voltage distribution systems
600 Vac, 12,000A continuous
cross bus and 200,000A
bus compartment structure 1
for increased strength.
systems. Primarily used as • Two-step stored-energy short-circuit capacity.
“standalone” distribution breaker closing Heavy-duty door hinges: 1
assemblies, they can Each breaker door is
also be incorporated into mounted with hinge pins. 1
secondary unit substations: Removal of the door is easily
UPS systems and generator
systems. Switchgear is ideally
accomplished by just lifting
the hinge pin. This allows
1
suited to applications such easy access to the breaker
as construction, commercial internal compartment for 1
and utility with distribution inspection and maintenance.
systems rated 600V or 1
below, 200 kAIC or below
bus bracing, and 12,000A 1
or below continuous loads
(cross bus). 1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 8-55
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchgear

Rear cover/doors: In Closing spring automatic Single-cylinder key interlock Ground: A ground bus is
1 Pow-R-Line C switchgear, discharge: Mechanical can be installed on the furnished the full length of
standard rear bolted covers interlocking automatically breaker. Accessible on the the switchgear assembly and
2 are provided. 48.00-inch-wide discharges the closing faceplate of the breaker, the is fitted with terminals for
(1219.2 mm) cells are split springs when the breaker device can be ordered to lock purchaser’s connections.
3 into two sections to facilitate
handling during removal and
is removed from its
compartment.
the breaker in the open or
closed position. Glass reinforced polyester
installation. Optional rear and bus bracing and
4 doors are also available. Optional safety shutters: support insulation system:
Positive acting safety Bus Features Glass reinforced polyester
5 Through-the-door design:
The following functions may
shutters that isolate the
breaker connections to the
Buses and connections: is a total system providing
exceptional mechanical
Vertical and cross bus
be performed without the main bus when the breaker and dielectric withstand
6 need to open the circuit is withdrawn from the cell
ratings in Pow-R-Line C
switchgear are based on a strength, as well as high
breaker door—lever the is an option offered for CSA® and ANSI standard resistance to heat, flame and
7 breaker between positions additional safety beyond our temperature rise of 65°C moisture. Substantial testing
(drawout), operate manual standard design. They reduce above a maximum ambient to demonstrate accelerated
8 charging system and view the potential of accidental air temperature of 40°C. effects of heating and cooling
the spring charge status flag, contact with live bus. on the mechanical and
Bus ampacities: Vertical
9 close and open breaker, view
and adjust trip unit and read
Optional insulating covers
(“boots”) are furnished and cross bus ratings in
dielectric properties of this
system prove it to provide
the breaker rating nameplate. on live main stationary Pow-R-Line C switchgear are superior performance for
1 disconnecting contacts in 2000, 3000, 4000, 5000 and decades of trouble-free
Cassette design: The breaker compartments equipped for 6000A. In addition, an 8000, operation.
1 cassette supports the
breaker in the cell, as well
future breakers. 10,000 and 12,000A cross
Optional bus insulation:
bus rating is available.
as on the movable extension Breaker inspection: Insulated bus systems with
1 rails when the breaker is When withdrawn on the Bus bracing: Vertical bus removable PVC boots for
placed into or removed rails, breaker is completely configuration provides an inspection and maintenance.
1 from the cell. The extension accessible for visual optional industry-leading
rails allow the breaker to be inspection; tilting is not short-circuit withstand rating Barriers: Optional vented
1 drawn out without having necessary. The rails are of 200,000A. Standard
bracing is 100,000A. It has
polypropylene barriers
isolate the main bus and
to de-energize the entire permanent parts of every
been verified through testing connections from the cable
1 switchgear lineup. breaker cassette.
to maximum withstand compartment providing
Accessibility: When the rear Interference interlocks: 200,000A short-circuit for added safety to the workers
1 door is open or removed, Supplied on breakers and a full 30 cycles. while reducing the potential
each breaker compartment in compartments where of objects falling into the bus
NNote: Short-circuit rating of
1 provides front access to
isolated, vertical wireways,
the compartments are of
the same physical size. switchgear assembly is limited to
compartment. In addition,
vertical barriers between
the interrupting capacity of the
primary disconnects and Interference interlocks ensure cable sections can be added
1 other breaker compartment an incorrect breaker cannot
lowest rated branch device.
to reduce potential hazards.
accessories for ease of field be inserted. Plating: Bolted, silver-plated Barriers are removable
1 wiring and troubleshooting
Optional key interlock copper main buses are to give access to the bus
field connections. standard. The plating is compartment for inspection
(cassette mounted): This
1 Four-position drawout: mechanism holds the breaker over the entire length of the and maintenance.
Breakers can be in connected, cell mechanically trip-free to bar, not just at the joints.
1 test, disconnected or prevent electrical or manual Optional tin-plated copper
removed position. The closing. Breaker can be buses are available.
1 breaker can be moved stored in compartment, and Full neutral: For four-wire
between the connected, test completely removed for applications, the neutral
1 and disconnected positions
while the compartment door
maintenance or for use as
a spare without disturbing
bus is rated 100% of main
bus rating as standard.
is closed. the interlock. Modification of
1 the breaker is not required.
Neutral cross bus ratings up
to a maximum of 12,000A
Single- or double-cylinder are available as an option.
1 cassette-mounted key Additionally, four-pole
interlock is available as breakers can be used in
1 an option. conjunction with four-wire
systems.
1
1
1
1
8-56 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchgear

Wiring Features Control wire: Standard wire Surge Protection Device (SPD) Integrated Transfer Switches
Cable compartment: is Type SIS insulated stranded Standard integrated surge Eaton automatic transfer
1
The cable compartment gives copper, extra flexible No. 14 protection device with switches (using power
ample room for terminating AWG minimum. integral disconnect is circuit breakers, including 2
the power cables. Removable Control wire marking: available if required. The SPD optional bypass-isolation
top roof sheets allow for Control wire marking is is mounted on the back pan, type) can be integrated 3
easy conduit hub installation. provided as a standard at and the removable display into a switchgear lineup.
The floor of the cable
compartment is open to allow
each end of the wire. As an is mounted on the door; the
SPD is protected by a small
Electrical and mechanical
coordination is ensured when
4
option, wire marking can be
cable entry from underground 30A fusible rotary switch. power circuit breaker transfer
duct banks. Optional bottom
added to the control wiring
by using heat shrink sleeve Please refer to Tab 9— switches are integrated into 5
plates are available. type marking. This marking is Components or contact the switchgear. Maximum
designed to be a permanent, Eaton for more information. selectivity is achieved due 6
In addition to cable, custom to the high withstand rating
busway and nonsegregated one-piece, heat-shrink sleeve
bus duct can be terminated designed to provide clear, PLC Transfer Schemes
of the power circuit breaker 7
durable identification of wires transfer switch.
in the compartment. Advanced PLC-based transfer
and cables.
and load shedding schemes
8
Lug pad: The lugs are Advanced Metering
Secondary terminal can be designed for various
located on the breaker run-
backs to accommodate lug compartment: There are applications such as data
and Communications 9
72 finger-safe secondary centres, health care facilities Eaton has an extensive line of
orientations at an optional
45-degree angle. This reduces connections for a standard and waste water treatment powerful metering products,
trip units, controllers and
1
the bending radius of the frame Pow-R-Line C breaker. plants. HMI is optional for
gateways that can be wired
cable needed for making the The customer’s secondary
terminal connections are
touch screen monitoring and
control of incoming, tie together in switchgears to 1
connections, thus reducing create an intelligent system
located at the front of the and feeder power circuit
installation and maintenance
time. Mechanical setscrew structure behind an optional breakers. Contact Eaton for and interface with Building 1
separate door, providing more information. Management and SCADA
type lugs are standard.
Optional NEMA two-hole access to these connections Systems. 1
compression lugs are without the need to open the Bus Duct Integration
available. breaker compartment door.
Custom bus duct can be
Special Dimensions 1
and Configurations
Short-circuiting terminal integrated into switchgear
Control raceway: A vertical
wireway is provided for blocks: Based on customer assemblies. Eaton can design Eaton has the ability to offer 1
specific requirement. Consult and manufacture custom bus custom dimensions to suit
routing of factory wiring in
each switchgear section. Eaton for more information. duct flanges to coordinate limited space requirements.
Special heights, special
1
Breaker secondary terminal with the bus duct risers of a
Shipping split connection: depths and widths, corner
blocks are mounted as As an option, at each
wide range of amperage.
sections, back-to-back 1
standard above each circuit shipping split, the control and front-access-only
breaker. The terminal blocks
are rated 30A, and will
connections are made with Transformer and configurations are available. 1
plug-in terminal blocks rated MCC Close-Coupling
accept bare wire, ring or
spade terminals for wire size
300V, 10A. The terminal
blocks mechanically interlock
Close-couple dry type,
Arc Flash Considerations 1
liquid-filled transformers or
maximum of No. 10. without removing the Arc flash is an ongoing
line or load connections.
motor control centres (MCC)
with standard switchgear concern in the electrical 1
Control circuits may be wired
in all cells without removing This method of making configurations can be industry. Eaton can offer
the circuit breaker. In the shipping split control supplied. Transformer unit- a variety of solutions to 1
addition, power circuits may connections increases the substations and MCC bus- reduce the risk of arc flash
be connected in the rear of speed of installation and coordination would create such as Arcflash Reduction 1
the switchgear at the same reduces the potential of a most compact lineup and Maintenance System in
time control circuits are being incorrect connections. minimization of installation power circuit breakers, safety
shutters in Magnum drawout
1
wired in the front of the time by eliminating cable
power circuit breakers, infra-
switchgear. installations.
red viewing windows and 1
For applications involving remote racking accessories.
excessive wiring, or 1
nonstandard terminal blocks,
terminal blocks are optionally
mounted on the rear frame
1
with the power cables where
they are readily accessible 1
for customer’s connections
and inspection. 1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 8-57
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchgear

Standards and Certifications Optional Breaker Lifting Device Options Padlockable Pushbutton Cover
1 • CSA® C22.2 No. 31 Accessories Eaton provides a variety of A padlockable cover is
ANSI C37.20.1 lifting options such as breaker available to limit access to the
2 •
• Built in an ISO®
Shunt Trip Device lifting yokes and portable lift ON and OFF pushbuttons.
certified facility The shunt trip opens trucks. Please refer to Eaton
3 the circuit breaker catalogue PG01301002E
Mechanical Operations Counter
instantaneously when its (Miscellaneous Accessories)
The operations counter is
4 coil is energized by a voltage for more information.
a mechanical device used
input. A total of two shunt
to provide a record of the
5 trips can be mounted on an
Eaton power circuit breaker.
Auxiliary Switch number of circuit operations.
Eaton’s Magnum DS Power An auxiliary switch provides It is mounted in the lower
6 Circuit Breakers comply with: remote electrical indication if right portion of the circuit
Electrical Motor Operator the circuit breaker is open or breaker and can be viewed
• ANSI C37.13
7 • ANSI C37.16
A motor operator is an closed. Up to three auxiliary
switches can be mounted
through the front cover.
electric motor assembly
ANSI C37.17 in the circuit breaker. Each
8 •
• ANSI C37.50
internally mounted in the
circuit breaker. It charges the switch has two normally open
Key Off Lock Provisions
closing springs electrically for (“a”) and two normally closed The key off lock secures
9 NNote: Consult Eaton for
remote or local operation. The (“b”) contacts for a total of the circuit breaker in the
Seismically Qualified designs
motor operator can be factory 12 available contacts. OFF position. It is mounted
and for ANSI certified designs.
1 or site installed. in the lower right portion of
the circuit breaker and can
Mechanical Trip Indicator Flag be viewed through the front
1 Spring Release Device A red, pop-out mechanical cover. The customer supplies
The spring release remotely trip flag is located just above the key lock. The provisions
1 closes the circuit breaker the trip unit in the circuit available are for Kirk.
when the coil is energized by breaker’s front cover. It
1 a voltage input. The closing operates by popping out
to indicate that the circuit
Latch Check Switch
spring must already be
breaker opened in response A latch check switch (LCS)
1 charged for the device
to work. to an overcurrent condition. indicates when the circuit
The flag is manually reset by breaker is “ready to close”.
1 pushing it back into position. The internal version of the
Bubble Cover The circuit breaker can be re- LCS is wired to the spring
1 Plexiglass breaker covers closed, even if the flag is not release. It will not permit
activation of the spring
for security and dust ingress reset. An optional overcurrent
release until the circuit
1 protection. trip switch, however, can be
used as an electrical lockout. breaker is fully charged and
the trip latch is reset.
1 Undervoltage Release
The undervoltage release Bell Alarm / Overcurrent
Trip Switch Cassettes
1 opens the circuit breaker
An overcurrent trip switch For information on breaker
when its supply voltage falls
(bell alarm) provides an cassettes, refer to Eaton
1 below 70%. If the release is
not energized to 85% of its electrical indication when catalogue RP01301001E.
supply voltage, the circuit a circuit breaker trips as
1 breaker cannot be reclosed a result of an overcurrent
electrically or manually. condition. Opening as a result
1 of a circuit breaker’s manual
open button, shunt trip or
1 undervoltage release does
not cause the overcurrent trip
switch to operate.
1
1
1
1
1
1
1
8-58 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchgear

Pow-R-Line C Switchgear—Typical Cell Configurations


1
Maximum 3000A Cross Bus a

2
3
Instrument Inst. Inst. Inst.
Compartment Comp.
or SPD
Comp.
or SPD
Comp.
or SPD 4
Main
800–12000–1600
Main
800–1200
Tie c
800–1200
Feeder
800–1200
5
2000–2500–3000 1600–2000 1600–2000 1600–2000
90.00 90.00 3000 90.00 3000 90.00 6
(2286.0) (2286.0) (2286.0) c (2286.0) Feeder
b b Blank or
Feeder
b Blank or
Tie or
b
800–1200
1600–2000
7
Utility Feeder
CT/PT
Compartment Feeder
8
Blank or Blank or
800–1200
Feeder Feeder
1600–2000 9
1
d d d
38.00 24.00 24.00 24.00
(965.2) (609.6) (609.6) (609.6)

72.00/78.00/84.00/90.00
(1828.8/1981.2/2133.6/2286.0)
72.00/78.00/84.00/90.00
(1828.8/1981.2/2133.6/2286.0)
72.00/78.00/84.00/90.00
(1828.8/1981.2/2133.6/2286.0)
72.00/78.00/84.00/90.00
(1828.8/1981.2/2133.6/2286.0)
1
1
1
3000A Maximum, 3200A, 4000A, 5000A, 6000A, 8000A Cross Bus a 4000A, 5000A, 6000A Cross Bus a
1
1
Feeder Inst. Inst. Instrument
800–1200
1600–2000
Comp.
or SPD
Comp.
or SPD
Compartment or SPD
1
Feeder Feeder
800–1200
Feeder Main 1
800–1200 800–1200 4000–5000–6000
1600–2000
90.00 Transition 90.00
1600–2000
90.00 2500 90.00
1600–2000
90.00 1
(2286.0) Cell (2286.0) (2286.0) (2286.0) Feeder f (2286.0)
Feeder
e e
800–1200
e Blank or
Feeder
c 800–1200
1600–2000
e
1
1600–2000 Utility
e 2500–3000

Feeder Feeder Feeder f


CT/PT
Compartment 1
800–1200 800–1200 800–1200
1600–2000 1600–2000
2500
1600–2000
2500–3000
1
24.00
(609.6)
d
24.00
(609.6)
d
24.00
(609.6)
d
24.00
(609.6)
d
48.00
(1219.2)
1
78.00/84.00/90.00 78.00/84.00/90.00 78.00/84.00/90.00 78.00/84.00/90.00 78.00/84.00/90.00 1
(1981.2/2133.6/2286.0) (1981.2/2133.6/2286.0) (1981.2/2133.6/2286.0) (1981.2/2133.6/2286.0) (1981.2/2133.6/2286.0)

1
NNote
a Higher bus ampacities available; please contact Eaton for more information.
1
b 90.00-inch (2286.0 mm) height does not include optional base channel. Standard height is 1.50 inches (38.1 mm), custom height of 2.00 inches (50.8 mm) or 4.00 inches (101.6 mm) available.
c Maximum one tie breaker per cell.
1
d 30.00-inch-wide (762.0 mm) cells are available for certain applications. Contact Eaton for more information.
e Feeder can be 800, 1200, 1600, 2000A; blank if there are two 2500A feeders in the same distribution section.
1
f Maximum one 3000A feeder per cell.

Consult Eaton for custom layouts.


1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 8-59
Low Voltage Switchboards and Switchgear
Pow-R-Line C Switchgear

4000A, 5000A, 6000A Cross Bus a


1
2
Instrument Instrument Instrument
3 Compartment or SPD Compartment or SPD Compartment or SPD
Instrument
Compartment or SPD

4 Main Main Main


4000–5000 4000–5000 4000
5 90.00 90.00 90.00 90.00
Feeder
4000–5000
(2286.0) (2286.0) (2286.0) (2286.0)
6 b b b b

7 Blank Blank
Tie
4000

8 Blank

9 48.00
(1219.2)
48.00
(1219.2)
48.00
(1219.2)
48.00
(1219.2)

1 78.00/84.00/90.00
(1981.2/2133.6/2286.0)
78.00/84.00/90.00
(1981.2/2133.6/2286.0)
78.00/84.00/90.00
(1981.2/2133.6/2286.0)
78.00/84.00/90.00
(1981.2/2133.6/2286.0)

1
1 NNote
a Higher bus ampacities available; please contact Eaton for more information.

1 b 90.00 inch (2286.0 mm) height does not include optional base channel. Standard height is 1.50 inches (38.1 mm), custom height of 2.00 inches (50.8 mm) or 4.00 inches (101.6 ) available.
Main breaker can be in cell B, C or D.
Consult Eaton for custom layouts.
1
1 Dimensions
Approximate Dimensions in Inches (mm)
1
1 Switchgear Dimensions
Pow-R-Line C Interrupting Short-Time
1 Cell Width Breaker Frame Rating Rating
24.00 (609.6) or 800A, 1600A, 2000A, Maximum 100 kA 85 kA for 60 cycles
1 30.00 (762.0) 3000A, 3200A
48.00 (1219.2) 4000A, 5000A, 6000A Maximum 100 kA 100 kA for 60 cycles
1
Breaker Frame Size
1 Ampere
Rating Height Depth Width
1 800–3200 16.40 (416.6) 15.40 (391.2) 16.30 (414.0)

1 4000–6000 16.40 (416.6) 15.40 (391.2) 34.20 (868.7)

1
1
1
1
1
1
1
8-60 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Contents
Switchboard Accessories and Modifications
1
Description Page
Moulded-Case Circuit Breakers 2
Magnum Power Circuit Breakers............................. 9-64
Trip Units.................................................................. 9-65 3
Fusible Switches...................................................... 9-71
Surge Protection Devices........................................ 9-75
4
Metering.................................................................. 9-76
5
6
7
8
Series C Moulded-Case Circuit Breaker Product Family
9
1
Moulded-Case Circuit Breakers 1
Quick Reference—Series C® Circuit Breakers a
1
Circuit Cont. Amp.
CSA® Listed Interrupting Ratings rms Symmetrical Amperes (kA) 1
Breaker Rating No. of Volts Trip Vac Ratings Vdc Ratings c
Type @ 40°C Poles AC DC Type b 120 120/240 240 277 347 480Y/277 480 600Y/347 600 125 250 125/250 1
F-Frame
ED 100–225 2, 3 240 125 N.I.T. — — 65 — — — — — — 10 — — 1
EDH 100–225 2, 3 240 125 N.I.T. — — 100 — — — — — — 10 — —
EDC 100–225 2, 3 240 125 N.I.T. — — 200 — — — — — — 10 — — 1
EHD 15–100 1 277 125 N.I.T. — — — 14 — — — — — 10 — —
EHD 15–100 2, 3 480 250 N.I.T. — — 18 — — — 14 — — — 10 — 1
FDB 15–150 1 347 125 N.I.T. — — — — 14 — — — — 10 — —
FDB 15–225 2, 3 600 250 N.I.T. — — 18 — — — 14 — 14 — 10 — 1
FDB 15–225 4 600 250 N.I.T. — — 18 — — — 14 — 14 — 10 —
FD 15–150 1 347 125 N.I.T. — — — 35 18 — — — — 10 — — 1
FD 15–225 2, 3 600 250 N.I.T. — — 65 — — — 35 — 18 — 10 —
FD 15–225 4 600 250 N.I.T. — — 65 — — — 35 — 18 — 10 — 1
FDE 15–225 3 600 — N.I.T. — — 65 — — — 35 — 18 — — —
HFD 15–30 1 347 125 N.I.T. — — — 65 25 — — — — 10 — — 1
HFD 15–225 2,3 600 250 N.I.T. — — 100 — — — 65 — 25 — 22 —
HFD 15–225 4 600 250 N.I.T. — — 100 — — — 65 — 25 — 22 —
1
HFDE 15–225 3 600 — N.I.T. — — 100 — — — 65 — 25 — — —
FDC d 15–30 1 347 125 N.I.T. — — — — 30 — — — — 10 — —
1
FDC d
FDC d
15–225
15–225
2, 3
4
600
600
250
250
N.I.T.
N.I.T.




200
200






100
100


35
35


22
22


1
FDCE d
FD-LFD
15–225
15–150
3
3
600
600


N.I.T.
N.I.T.




200
200





200
100



25
200






1
NNote
a Refer to catalogue no. PG01200001K for complete Series C Moulded-Case Circuit Breaker information.
1
b N.I.T. is non-interchangeable trip unit and I.T. is interchangeable trip unit.
c Two-pole circuit breaker, or two poles of three-pole circuit breaker at 250 Vdc.
1
d Current limiting.
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 9-61
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Quick Reference—Series C Circuit Breakers a, continued


1 CSA Listed Interrupting Ratings rms Symmetrical Amperes (kA)
Circuit Cont. Amp.
2 Breaker Rating No. of
Volts
Trip
Vac Ratings Vdc Ratings c

Type @ 40°C Poles AC DC Type b 120 120/240 240 277 480 600 125 250 125/250
3 J-Frame
JD 70–250 2, 3, 4 600 250 I.T. — — 65 — 35 18 — 10 —
4 HJD 70–250 2, 3, 4 600 250 I.T. — — 100 — 65 25 — 22 —
JDC d 70–250 2, 3, 4 600 250 I.T. — — 200 — 100 35 — 22 —
5 K-Frame
DK 250–400 2, 3 240 250 I.T. — — 65 — — — — 10 —
6 KD 100–400 2, 3, 4 600 250 I.T. — — 65 — 35 25 — 10 —
CKD 100–400 2, 3, 4 600 250 I.T. — — 65 — 35 25 — 10 —
7 HKD 100–400 2, 3, 4 600 250 I.T. — — 100 — 65 35 — 22 —

8 CHKD
KDC d
100–400
100–400
2, 3, 4
2, 3, 4
600
600
250
250
I.T.
I.T.




100
200


65
100
35
65


22
22

9 L-Frame
LD 300–600 2, 3, 4 600 250 I.T. — — 65 — 35 25 — 22 —

1 CLD
HLD
300–600
300–600
2, 3, 4
2, 3, 4
600
600
250
250
I.T.
I.T.




65
100


35
65
25
35


22
25

1 CHLD 300–600 2, 3, 4 600 250 I.T. — — 100 — 65 35 — 25 —


LDC d 300–600 2, 3, 4 600 250 I.T. — — 200 — 100 50 — 25 —

1 CLDC d 300–600 2, 3, 4 600 250 I.T. — — 200 — 100 50 — 25 —


MDL-Frame
1 MDL 300–800 2, 3 600 250 I.T. — — 65 — 50 25 — 22 —
CMDL 300–800 2, 3 600 250 I.T. — — 65 — 50 25 — 22 —
1 HMDL 300–800 2, 3 600 250 I.T. — — 100 — 65 35 — 25 —
CHMDL 300–800 2, 3 600 250 I.T. — — 100 — 65 35 — 25 —
1 N-Frame
ND 400–1200 3, 4 600 — N.I.T. — — 65 — 50 25 — — —
1 CND 400–1200 3, 4 600 — N.I.T. — — 65 — 50 25 — — —
HND 400–1200 3, 4 600 — N.I.T. — — 100 — 65 35 — — —
1 CHND 400–1200 3, 4 600 — N.I.T. — — 100 — 65 35 — — —
NDC 400–1200 3, 4 600 — N.I.T. — — 200 — 100 65 — — —
1 CNDC 400–1200 3, 4 600 — N.I.T. — — 200 — 100 65 — — —
R-Frame
1 RD 1600 800–1600 3, 4 600 — N.I.T. — — 125 — 65 50 — — —
CRD 1600 800–1600 3, 4 600 — N.I.T. — — 125 — 65 50 — — —
1 RD 2000 1000–2000 3, 4 600 — N.I.T. — — 125 — 65 50 — — —
CRD 2000 1000–2000 3, 4 600 — N.I.T. — — 125 — 65 50 — — —
1 RD 2500 1200–2500 3, 4 600 — N.I.T. — — 125 — 65 50 — — —

1 RDC 1600
CRDC 1600
800–1600
800–1600
3, 4
3, 4
600
600


N.I.T.
N.I.T.




200
200


100
100
65
65





1 RDC 2000
CRDC 2000
1200–2500
1000–2000
3, 4
3, 4
600
600


N.I.T.
N.I.T.




200
200


100
100
65
65





1 RDC 2500 1200–2500


HMCP Motor Circuit Protectors
3, 4 600 — N.I.T. — — 200 — 100 65 — — —

1 Current Limit-R® Current Limiting Circuit Breakers—Non-Fused Type


LCL 125–400 2, 3 600 — N.I.T. — — 200 — 200 100 — — —
1 TRI-PAC® Current Limiting Circuit Breakers—Fused Type
FB 15–100 2, 3 600 250 N.I.T. — — 200 — 200 200 — — —
1 LA 70–400 2, 3 600 250 I.T. — — 200 — 200 200 — — —
NB 300–800 2, 3 600 250 I.T. — — 200 — 200 200 — — —
1 NNote
a Refer to catalogue no. PG01200001K for complete Series C Moulded-Case Circuit Breaker information.
1 b N.I.T. is non-interchangeable trip unit and I.T. is interchangeable trip unit.
c Two-pole circuit breaker, or two poles of three-pole circuit breaker at 250 Vdc.
1 d Current limiting.

9-62 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca


Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Quick Reference—Series G® Circuit Breakers a

Breaker Capacity (kA rms) Vac 50–60 Hz


1
CSA
Vac Vdc
Trip Units c
FT-AM /AT-AM
2
Max.
Ratings Ratings Electronic (Digitrip™ RMS 310) Thermal-Magnetic Electronic RMS d
Circuit
Breaker
Rated
Current No. of Ampere Fixed Adjustable 3
Type (Amperes) Poles 240 480 600 125/250 b Range Interchangeable Built-In Thermal Thermal Magnetic LS LSI LSG LSIG
JG-Frame 4
E 250 2, 3, 4 65 25 18 10 20–250     Adjustable    
S 250 2, 3, 4 85 35 18 22 20–250     Adjustable     5
H 250 2, 3, 4 100 65 25 22 20–250     Adjustable    
C 250 3, 4 200 100 35 42 20–250     Adjustable     6
U 250 3, 4 200 150 50 50 20–250 Adjustable
7
       
LG-Frame
E
S
600
600
3, 4
3, 4
65
85
35
50
18
25
22
22
100–600
100–600








Adjustable
Adjustable
b
b
b
b
b
b
b
b
8
H
C
600
600
3, 4
3, 4
100
200
65
100
35
50
42
42
100–600
100–600








Adjustable
Adjustable
b
b
b
b
b
b
b
b
9
U 600 3, 4 200 150 65 50 100–600     Adjustable b b b b
1
Quick Reference—Series G Circuit Breakers, continued 1
Breaker Capacity (kA rms) Vac 50–60 Hz
Trip Units 1
Electronic
Circuit
Max.
Rated
CSA
Vac Ratings
Electronic
(Digitrip RMS 310+)
(Digitrip RMS 310+,
610 and 910) Electronic d
1
Breaker Current No. of Ampere
Type (Amperes) Poles 240 480 600 Range Built-In Built-In LI LS LSI LIG LSG LSIG ALSI ALSIG 1
NG-Frame
S 800, 1200 2, 3, 4 85 50 25 320–1200  — —   —     1
H 800, 1200 2, 3, 4 100 65 35 320–1200  — —   —    
C 800, 1200 2, 3, 4 200 100 65 320–1200  — —   —     1
RG-Frame
H 1600, 2000, 2500 3, 4 125 65 50 800–2500 —  e   e     1
C 1600, 2000, 2500 3, 4 200 100 65 800–2500 —  e   e    

NNote
1
a Refer to catalogue no. CA08100005E for complete Series G Moulded-Case Circuit Breaker information.
b Two poles in series.
1
c F = Fixed, A = Adjustable, T = Thermal, M = Magnetic.
d Not suitable for DC application. Four-pole ground fault not available.
1
e Available only on Digitrip 610 and 910 trip units.
1
1
1
1
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 9-63
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Magnum Power Circuit Breakers


1
Magnum DS® Low Voltage Power Circuit Breaker Family ANSI Rated for Switchgear Applications
2
3
4
5
6
7
8
9
Magnum DS Switchgear Low Voltage Power Circuit Breakers
1
rms Symmetrical Current Ratings kA 50/60 Hz a

1 Frame Breaker Type Frame Interrupting Interrupting Interrupting Short-Time


Fixed Internal
Instantaneous
Available Current Sensor and Rating
Plugs for Digitrip RMS Trip Unit
Amperes Catalogue Number Type at 254 Vac at 508 Vac at 635 Vac Withstand Trip (Establishes Breaker In Rating)
1 800 MDS-408 Standard 42 42 42 42 — 200, 250, 300, 400, 600, 800
MDS-608 Standard 65 65 65 65 —
1 MDS-808 Standard 85 85 85 85 —
MDS-C08 Standard 100 100 100 85 85
1 MDS-L08 b Standard 200 200 200 — —

1 1200 MDS-412
MDS-512
Standard
Standard
42
50
42
50
42
50
42
50


200, 250, 300, 400, 600, 800, 1000, 1200

1 MDS-612
MDS-812
Standard
Standard
65
85
65
85
65
85
65
85

1 1600
MDS-C12
MDS-616
Standard
Standard
100
65
100
65
100
65
85
65

— 200, 250, 300, 400, 600, 800, 1000,
1200, 1600
1 MDS-816
MDS-C16
Standard
Standard
85
100
85
100
85
100
85
85

85

1 2000
MDS-L16 b
MDS-620
Standard
Standard
200
65
200
65
200
65

65

— 200, 250, 300, 400, 600, 800, 1000, 1200,
1600, 2000
1 MDS-820 Standard 85 85 85 85 —
MDS-C20 Standard 100 100 100 85 85

1 MDS-L20 b Standard 200 200 200 — —


3200 MDS-632 Standard 65 65 65 65 — 200, 250, 300, 400, 600, 800, 1000, 1200,
1 MDS-832 Standard 85 85 85 85 — 1600, 2000, 2500, 3000, 3200

MDS-C32 Standard 100 100 100 85 85


1 4000 MDS-840 Double 85 85 85 85 — 2000, 2500, 3200, 4000
MDS-C40 Double 100 100 100 100 —
1 5000 MDS-850 Double 85 85 85 85 — 2500, 3200, 4000, 5000
MDS-C50 Double 100 100 100 100 —
1 NNote
a Interrupting ratings shown based on breaker equipped with integral Digitrip RMS trip unit. Interruption ratings for non-automatic breakers are equal to the published short-time withstand rating.
1 These interruption ratings are based on the standard duty cycle consisting of an open operation, a 15-second interval and a close-open operation, in succession, with delayed tripping in case
of short-delay devices. The standard duty cycle for short-time ratings consists of maintaining the rated current for two periods of 1/2 seconds each, with a 15-second interval of zero current
between the two periods.
1 b Magnum MDSL current limiting power circuit breaker with integral current limiters. Current limiter selected determines short-time and fixed instantaneous trip rating. Maximum voltage rating
is 600 Vac.
1
1
1
9-64 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Trip Units
1
Moulded-Case Digitrip Selection Guide 2
Trip Unit Digitrip Digitrip Digitrip Digitrip Digitrip Digitrip Digitrip Digitrip
Type RMS 310+ RMS 310 RMS 510 RMS 610 RMS 810 RMS 910 OPTIM 550 OPTIM 1050
3
rms sensing Yes Yes Yes Yes Yes Yes Yes Yes
Breaker Type 4
Frame FDE, JG, K, LG, NG, RG a K, L, M, N, R R R, RG R R, RG K, L, N K, L, N, R
Ampere range 15–2500 15–2500 800–5000 800–5000 800–5000 800–5000 70–1200 70–5000 5
Interrupting rating at 480V 35, 65, 100, 150 kA 35, 65, 100 kA 65, 100 kA 65, 100 kA 65, 100 kA 65, 100 kA 35, 65, 100 kA 35, 65, 100 kA
Protection 6
Ordering options LS, LSG LSI, LSIG LS, LSG LSI, LSIG LI, LS, LSI, LIG, LI, LS, LSI, LIG, LI, LS, LSI, LIG, LI, LS, LSI, LIG, LSI, LSI (A), LSI (A), LISG
LSG, LSIG LSG, LSIG LSG, LSIG LSG, LSIG LSIG 7
Arcflash Reduction No ALSI, ALSIG b No No No No No No No No
Maintenance System™ 8
Fixed rated plug (In) No Yes Yes Yes Yes Yes Yes Yes Yes Yes
Overtemperature trip Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 9
Long Delay Protection (L)
Adjustable rating plug (In) No Yes No No No No No No 1
Long delay pickup 40–100% frame 0.5–1.0 (In) c 0.5–1.0 x (In) 0.5–1.0 x (In) 0.5–1.0 x (In) 0.5–1.0 x (In) 0.4–1.0 x (In) 0.4–1.0 x (In)
Long delay time I2t 2–24 seconds 10 seconds 2–24 seconds 2–24 seconds 2–24 seconds 2–24 seconds 2–24 seconds 2–24 seconds 1
Long delay time I4t No No No No No No 1–5 seconds 1–5 seconds
Long delay thermal memory Yes Yes Yes Yes Yes Yes Yes Yes 1
High load alarm Yes No No 0.85 x Ir 0.85 x Ir 0.85 x Ir 0.5–1.0 x Ir 0.5–1.0 x Ir
Short Delay Protection (S) 1
Short delay pickup Varies by frame d 200–800% x (In) 200–600% 200–600% 200–600% 200–600% 150–800% 150–800%
S1 and S2 x (Ir) S1 and S2 x (Ir) S1 and S2 x (Ir) S1 and S2 x (Ir) x (Ir) x (Ir) 1
Short delay time I2t Yes No 100 ms No 100–500 ms 100–500 ms 100–500 ms 100–500 ms 100–500 ms 100–500 ms
Short delay time flat No Inst–300 ms No Inst–300 ms 100–500 ms 100–500 ms 100–500 ms 100–500 ms 100–500 ms 100–500 ms 1
Short delay time ZSI Yes No Yes Yes Yes Yes Optional Yes
Instantaneous Protection (I) 1
Instantaneous pickup No Varies by No 200–800% 200–600% 200–600% 200–600% 200–600% 200–800% x (In) 200–800% x (In)
frame d x (In) M1 and M2 x (In) M1 and M2 x (In) M1 and M2 x (In) M1 and M2 x (In) 1
Discriminator No No Yes e Yes e Yes e Yes e Yes Yes
Instantaneous override Yes Yes Yes Yes Yes Yes Yes Yes 1
Ground Fault Protection (G)
Ground fault alarm Yes Yes No No No No 20/25–100% f 20/25–100% gh 1
Ground fault pickup 20–100% frame f Var/frame f 25–100% x In f 25–100% x In f 25–100% x In f 25–100% x In f 20/25–100% f 20/25–100% gh
Ground fault delay I2t No No 100–500 ms 100–500 ms 100–500 ms 100–500 ms 100–500 ms 100–500 ms 1
Ground fault delay flat Inst–300 ms Inst–500 ms 100–500 ms 100–500 ms 100–500 ms 100–500 ms 100–500 ms 100–500 ms
Ground fault ZSI Yes No Yes Yes Yes Yes Optional Yes 1
Ground fault Yes Yes Yes Yes Yes Yes Yes Yes
thermal memory 1
System Diagnostics
Cause of trip LEDs No No Yes Yes Yes Yes Yes Yes 1
Magnitude of No No No Yes Yes Yes Yes Yes
trip information 1
Remote signal contacts No No No Yes Yes Yes No Yes
Legend NNote 1
BIM = Breaker Interface Module a No rating plugs necessary. e LS/LSG only.
Is
In
=
=
Sensor Rating
Rating Plug
b Only available on LG, NG and f Not to exceed 1200A. 1
RG breaker. g L- and N-Frames *20–100% x Is.
Ir = LDPU Setting x In
c Adjust by rating plug.
d FDE and JG 200–1200% x In
R-Frame *25–100% x In. 1
h By OPTIMizer/BIM.
LG 200–1200% x In
NG 200–900% x In 1
RG 200–800% x In
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 9-65
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Moulded-Case Digitrip Selection Guide, continued


1 Trip Unit Digitrip Digitrip Digitrip Digitrip Digitrip Digitrip Digitrip Digitrip
Type RMS 310+ RMS 310 RMS 510 RMS 610 RMS 810 RMS 910 OPTIM 550 OPTIM 1050
2 System Monitoring

3 Digital display
Current
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes a
Yes
Yes a
Yes

4 Voltage
Power and energy
No
No b
No
No c
No
No
No
No
No
Yes
Yes
Yes
No
No
No
Yes

5 Power quality harmonics


Power factor
No
No
No
No
No
No
No
No
No
Yes (over
Yes
Yes
No
No
Yes
Yes
PowerNet only)
6 Communications

7 PowerNet™
Testing
No No No No Yes Yes Optional Yes

8 Testing method Test kit Test set Integral Integral Integral Integral OPTIMizer, OPTIMizer, BIM,
BIM, PowerNet PowerNet
(optional)
9 Legend NNote
BIM = Breaker Interface Module a By OPTIMizer/BIM.
1 Is = Sensor Rating b Yes, with addition of Power Monitoring/
In = Rating Plug Metering Module (PM3).
1 Ir = LDPU Setting x In
c Yes, with addition of Energy Sentinel.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
9-66 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Digitrip Trip Units for Magnum DS Power Circuit Breakers


Digitrip 520 Digitrip 520M Digitrip 520MC Digitrip 1150+ a
1
2
3
Trip Unit Type 4
Ampere range 200–6000A 200–6000A 200–6000A 200–6000A
Interrupting rating at 480V 42–200 kA 42–200 kA 42–200 kA 42–200 kA 5
rms sensing Yes Yes Yes Yes
Protection and Coordination 6
Protection Ordering options LI, LSI, LSIG LSI, LSIG, LSIA LSI, LSIG, LSIA LSI, LSIG, LSIA
Fixed rating plug (In) Yes Yes Yes Yes
7
Long delay protection (L)
Overtemperature trip
Long delay pickup
Yes
0.4–1.0 x (In)
Yes
0.4–1.0 x (In)
Yes
0.4–1.0 x (In)
Yes
0.4–1.0 x (In)
8
Long delay time I t at 6 x Ir 2–24 seconds 2–24 seconds 2–24 seconds 2–24 seconds
9
2

Long delay time I4t No No No 1–5 seconds


IEEE curves
Long delay thermal memory
No
Yes
No
Yes
No
Yes
Yes
Yes
1
Short delay protection (S)
High load alarm
Short delay pickup
No
200–1000% x (Ir) and M1
No
200–1000% x (Ir) and M1
No
200–1000% x (Ir) and M1
0.5–1.0 x (Ir)
200–1000% x (Ir) and M1
1
Short delay time I2t at 8 x Ir
Short delay time flat
100–500 ms
100–500 ms
100–500 ms
100–500 ms
100–500 ms
100–500 ms
100–500 ms
100–500 ms
1
Short delay time ZSI Yes Yes Yes Yes
1
Instantaneous protection (I) Instantaneous pickup 200–1000% x (In) and M1 200–1000% x (In) and M1 200–1000% x (In) and M1 200–1000% x (In) and M1
Making current release Yes Yes Yes Yes 1
Off position LSI and LSIG Yes Yes Yes
Ground fault protection (G) b Ground fault alarm No Yes Yes Yes 1
Ground fault pickup 25–100% x (In) 25–100% x (In) 25–100% x (In) 24–100% x (In)
Ground fault delay I2t at 0.625 x In 100–500 ms 100–500 ms 100–500 ms 100–500 ms 1
Ground fault delay flat 100–500 ms 100–500 ms 100–500 ms 100–500 ms
Ground fault ZSI Yes Yes Yes Yes 1
Ground fault thermal memory Yes Yes Yes Yes
Disable ground fault protection No No No No 1
Neutral protection (N) Model LSI Model LSI Model LSI Model LSI
Legend NNote 1
In = Rating Plug and Sensor Rating a Over and undervoltage alarm or trip, b 1200A maximum ground fault setting
Ir = Long Delay Pickup Setting over and underfrequency alarm or trip,
voltage unbalance alarm or trip, reverse
per UL/NEC.® 1
power trip, and phase rotation alarm
are included. 1
1
1
1
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 9-67
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Digitrip Trip Units for Magnum DS Power Circuit Breakers, continued


1 Digitrip 520 Digitrip 520M Digitrip 520MC Digitrip 1150+ a

2
3
4 Trip Unit Type
System Diagnostics
5 Cause-of-trip LEDs Yes Yes Yes Yes
Magnitude of trip information No Yes Yes Yes
6 Remote signal contacts No Yes Yes Yes
Programmable contacts No No No Yes
7 System Monitoring

8 Digital display
Current (% ) full scale sensor
No
No
4-character LCD
Yes ±2%
4-character LCD
Yes ±2%
24-character LED
Yes ±1%

9 Voltage (%) L to L
Power and energy (%)
No
No
No
No
No
No
Yes ±1%
Yes ±2%

1 Apparent power kVA and demand


Reactive power kVAR
No
No
No
No
No
No
Yes
Yes

1 Power factor No No No Yes


Crest factor No No No Yes

1 Power quality—harmonics No No No Yes


% THD, waveform capture No No No Yes
1 System Communications
Type No No INCOM™ INCOM/TripLink
1 Power supply in breaker — Optional Standard Standard
Additional Features
1 Trip log (three events) No No No Yes
Electronic operations counter No No No Yes
1 Testing method b Test set Test set Test set Integral and test set
Waveform capture No No No Yes
1 Arcflash Reduction Maintenance System No No Yes Yes
Breaker health monitor No No No Yes
1 Protective relay functions No No No Yes a
Legend NNote
1 In = Rating Plug and Sensor Rating a Over and undervoltage alarm or trip, b Test set for secondary injection.
Ir = Long Delay Pickup Setting over and underfrequency alarm or trip,
1 voltage unbalance alarm or trip, reverse
power trip, and phase rotation alarm
are included.
1
1
1
1
1
1
1
1
1
1
9-68 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Digitrip Trip Units for Magnum DS Power Circuit Breakers, continued


Digitrip 520i Digitrip 520Mi Digitrip 520MCi Digitrip 1150i+ a
1
2
3
Trip Unit Type 4
Ampere range 200–6300A 200–6300A 200–6300A 200–6300A
Interrupting rating at 690V 40–100 kA 40–100 kA 40–100 kA 40–100 kA 5
rms sensing Yes Yes Yes Yes
Protection and Coordination 6
Protection Ordering options LI, LSI, LSIG LSI, LSIG, LSIA LSI, LSIG, LSIA LSI, LSIG, LSIA
Fixed rating plug (In) Yes Yes Yes Yes
7
Long delay protection (L)
Overtemperature trip
Long delay setting
Yes
0.4–1.0 x (In)
Yes
0.4–1.0 x (In)
Yes
0.4–1.0 x (In)
Yes
0.4–1.0 x (In)
8
Long delay time I t at 6 x Ir 2–24 sec 2–24 sec 2–24 sec 2–24 sec
9
2

Long delay time I4t No No No 1–5 sec


IEC Type A, B, C curves
Long delay thermal memory
No
Yes
No
Yes
No
Yes
Yes
Yes
1
Short delay protection (S)
High load alarm
Short delay pickup
No
200–1000% x (Ir) and M1
No
200–1000% x (Ir) and M1
No
200–1000% x (Ir) and M1
0.7–1.0 x Ir
150–1000% x (Ir) and M1
1
Short delay time I2t at 8 x Ir
Short delay time flat
100–500 ms
100–500 ms
100–500 ms
100–500 ms
100–500 ms
100–500 ms
100–500 ms
100–500 ms
1
Short delay time ZSI Yes Yes Yes Yes
1
Instantaneous protection (I) Instantaneous pickup 200–1000% x (In) and M1 200–1000% x (In) and M1 200–1000% x (In) and M1 200–1000% x (In) and M1
Making current release Yes Yes Yes Yes 1
Off position Yes Yes Yes Yes
Earth fault protection (G) Earth fault alarm No Yes Yes Yes 1
Earth fault pickup 25–100% x (In) 25–100% x (In) 25–100% x (In) 24–100% x (In)
Earth fault delay I2t at 0.625 x In 100–500 ms 100–500 ms 100–500 ms 100–500 ms 1
Earth fault delay flat 100–500 ms 100–500 ms 100–500 ms 100–500 ms
Earth fault ZSI Yes Yes Yes Yes 1
Earth fault memory Yes Yes Yes Yes
Disable ground fault protection No No No Yes 1
Neutral protection (N) Model LSI Model LSI Model LSI Model LSI
Legend NNot 1
In = Rating Plug and Sensor Rating a Over and undervoltage alarm or trip,
Ir =
i =
Long Delay Pickup Setting
Trip units are only used on
over and underfrequency alarm or trip,
voltage unbalance alarm or trip, reverse
1
IEC breakers with earth fault power trip, and phase rotation alarm
are included. 1
1
1
1
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 9-69
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Digitrip Trip Units for Magnum DS Power Circuit Breakers, continued


1 Digitrip 520i Digitrip 520Mi Digitrip 520MCi Digitrip 1150i+ a

2
3
4 Trip Unit Type
System Diagnostics
5 Cause of trip LEDs Yes Yes Yes Yes
Magnitude of trip information No No No Yes
6 Remote signal contacts No Yes Yes Yes
Programmable contacts No No No 2
7 System Monitoring

8 Digital display
Current (%) full scale sensor
No
No
4-Character LCD
Yes ± 2%
4-Character LCD
Yes ± 2%
24-Character LED
Yes ± 1%

9 Voltage (%) L to L
Power and energy (%)
No
No
No
No
No
No
Yes ± 1%
Yes ± 2%

1 Apparent power kVA and demand


Reactive power kVAR
No
No
No
No
No
No
Yes
Yes

1 Power factor No No No Yes


Crest factor No No No Yes

1 Power quality—harmonics No No No Yes


% THD No No No Yes
1 System Communications
Type — — INCOM/PowerNet/Modbus b/ INCOM/PowerNet/TripLink/
1 Power supply in breaker N/A Optional
PROFIBUS b
Standard
Modbus b/PROFIBUS b
Standard

1 Additional Features
Trip log (three events) No No No Yes
1 Electronic operations counter No No No Yes
Testing method c Test set Test set Test set Integral and test set
1 Waveform capture No No No Yes
ARMs (Arcflash Reduction Maintenance System Mode) No No Yes Yes d
1 Breaker health monitor No No No Yes
Programmable relay functions No No No Yes a
1 Legend NNot
In = Rating Plug and Sensor Rating a Over and undervoltage alarm or trip,
1 Ir =
i =
Long Delay Pickup Setting
Trip units are only used on
over and underfrequency alarm or trip,
voltage unbalance alarm or trip, reverse
IEC breakers with earth fault power trip, and phase rotation alarm
1 are included
b Requires externally mounted MMINT
1 or PMINT module.
c Test set for secondary injection.

1 d Contact Eaton for availability.

1
1
1
1
1
1
1
9-70 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Fusible Switches
1
Horizontally Mounted Fusible Switches Fusible Switch Ratings
Rating Horizontally
2
(Amperes/Voltage) Fuse Type Unit Size a Mounted
30 250 AC or DC R 4X Twin
3
30/60/100A
60
600 AC
250 AC or DC
R, J
R
4X
4X
Twin
Twin
4
30/60/100A

100
600 AC
250 AC or DC
R, J
R
4X
4X
Twin
Twin
5
200A

200
600 AC
250 AC or DC
R, J
R, T
5X
6X
Twin
Single or twin
6
400A

400
600 AC
250 AC or DC
R, J, T
R, T
6X
9X
Single or twin
Single
7
600/800A
600
600 AC
250 AC
R, J, T
R, T
9X
11X
Single
Single
8
600 AC R, J, T 11X Single
9
800 250 AC T 11X Single
1200A 600 AC L, T 11X Single 1
1200 250 AC T 15X Single
600 AC L 15X Single 1
NNot
a 1X = 1-3/8 inch.
1
1
1
Horizontally Mounted Fusible Switches—X Spacing a

1
30–60 30–60
4X
38.00
100A 100A
1
(965.2)
Wide 200A 6X
1
30–60 30–60 5X 1
100A 100A

200A 200A 6X 1
1
400A 9X
1
48.00
(1219.2)
Wide 600/800A 11X 1
Structure
1
1200A 15X
1
1
1
NNote: 200A, 600V with Class R fuses available as a single unit only.
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 9-71
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Fusible Switch Selection Guide


1 Dimensions in Inches (mm)

2 30/60/100A 400A
3 18.00 (457.2) Wide, 4X High, Twin Fusible Switch 22.00 (558.8) Wide, 9X High, Single Fusible Switch a

Ampere Rating Ampere Rating Fuse Type Catalogue Number


4 Unit 1 Unit 2 Fuse Type Catalogue Number 240 Vac or 250 Vac

5 240 Vac or 250 Vdc 400 R FDPW325R


30 30 R FDPWT3211R 400 (Main) R FDPW325MR
6 30 60 R FDPWT3212R 600 Vac
30 100 R FDPWT3213R 400 R FDPW365R
7 60 60 R FDPWT3222R 400 (Main) R FDPW365MR
60 100 R FDPWT3223R 400 J FDPW365J
8 100 100 R FDPWT3233R 400 (Main) J FDPW365MJ
600 Vac
9 30 30 R FDPWT3611R 18.00 (457.2) Wide, 16X High—Top Feed Main a

30 30 J FDPWT3611J Ampere Rating Fuse Type Catalogue Number


1 30 60 R FDPWT3612R
240 Vac or 250 Vac
30 60 J FDPWT3612J
400 R FDPW325TR
1 60 60 R FDPWT3622R
600 Vac
60 60 J FDPWT3622J
1 400
400
R
J
FDPW365TR
FDPW365TJ
22.00 (558.8) Wide, 5X High, Twin Fusible Switch
1 Ampere Rating 18.00 (457.2) Wide, 16X High—Bottom Feed Main a
Unit 1 Unit 2 Fuse Type Catalogue Number
1 600 Vac
Ampere Rating Fuse Type Catalogue Number
240 Vac or 250 Vac
30 100 R FDPWT3613R
1 60 100 R FDPWT3623R
400 R FDPW325BR
600 Vac
1 100 100 R FDPWT3633R
400 R FDPW365BR
400 J FDPW365BJ
1 200A NNot
a For cable-in/cable-out application of a branch switch, additional terminals are required.
1 22.00 (558.8) Wide, 6X High, Twin Fusible Switch Order the terminal kit TA750FDPW. The kit contains three terminals and hardware.
Ampere Rating
1 Unit 1 Unit 2 Fuse Type Catalogue Number

1 240 Vac or 250 Vdc


200 200 R FDPBT3244R

1 200
600 Vac
200 R FDPBT3244RDS

1 200 200 J FDPBT3644J


200 200 J FDPBT3644JDS
1 18.00 (457.2) Wide, 6X High, Single Fusible Switch
1 Ampere Rating Fuse Type Catalogue Number
240 Vac or 250 Vac
1 200 T FDPBS324F
200 R FDPBS324R
1 600 Vac
200 R FDPBS364R
1 200 J FDPBS364J
200 T FDPBS364F
1
1
1
9-72 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

600A 1200A
1
22.00 (558.8) Wide, 11X High, Single Fusible Switch a 22.00 (558.8) Wide, 15X High, Single Fusible Switch c

Ampere Rating Fuse Type Catalogue Number Ampere Rating Fuse Type Catalogue Number 2
240 Vac or 250 Vac
600 R FDPW326R
240 Vac
1200 T FDPW328F
3
600 (Main)
600 Vac
R FDPW326MR 1200 (Main)
600 Vac
T FDPW328MF
4
600 R FDPW366R 1200 L FDPW368 5
600 (Main) R FDPW366MR 1200 (Main) L FDPW368M
600 J FDPW366J
22.00 (558.8) Wide, 16X High—Top Feed Main c
6
600 (Main) J FDPW366MJ

18.00 (457.2) Wide, 16X High—Top Feed Main a


Ampere Rating Fuse Type Catalogue Number 7
240 Vac
Ampere Rating Fuse Type Catalogue Number 1200 T FDPW328TF 8
240 Vac or 250 Vac 600 Vac
600 R FDPW326TR 1200 L FDPW368T 9
600 Vac
600 R FDPW366TR 22.00 (558.8) Wide, 16X High—Bottom Feed Main c 1
600 J FDPW366TJ Ampere Rating
240 Vac
Fuse Type Catalogue Number
1
18.00 (457.2) Wide, 16X High—Bottom Feed Main a

Ampere Rating Fuse Type Catalogue Number


1200 T FDPW328BF 1
600 Vac
240 Vac or 250 Vac 1200 L FDPW368B 1
600 R FDPW326BR NNote
600 Vac a For cable-in/cable-out application of a branch switch, additional terminals are required. 1
600 R FDPW366BR Order two of the terminal kit TA750FDPW. Each kit contains three terminals and hardware.
600 J FDPW366BJ b For cable-in/cable-out application of a branch switch, additional terminals are required.
Order three of the terminal kit TA750FDPW. Each kit contains three terminals and hardware.
1
c For cable-in/cable-out application of a branch switch, additional terminals are required.
Order four of the terminal kit TA750FDPW. Each kit contains three terminals and hardware. 1
800A

22.00 (558.8) Wide, 11X High, Single Fusible Switch b


1
Ampere Rating Fuse Type Catalogue Number 1
240 Vac
800 T FDPW327F 1
800 (Main) T FDPW327MF
600 Vac 1
800 L FDPW367
800 (Main) L FDPW367M
1
18.00 (457.2) Wide, 16X High—Top Feed Main b 1
Ampere Rating Fuse Type Catalogue Number
1
240 Vac
800 T FDPW327TF 1
600 Vac
800 L FDPW367T 1
18.00 (457.2) Wide, 16X High—Bottom Feed Main b
1
Ampere Rating Fuse Type Catalogue Number
240 Vac 1
800 T FDPW327BF
600 Vac
1
800 L FDPW367B
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 9-73
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

FDPW Switch Ratings


1 Horsepower Rating
Short-Circuit Size and Type of Cu/Al

2 Ampere Rating Voltage Rating kAIC Standard Maximum Fuse Type Conductor per Phase
30A switch 240 Vac 200 3 7.5 R #14 to 1/0

3 480 Vac 200 5 15 R, J #14 to 1/0


600 Vac 200 7.5 20 R, J #14 to 1/0
4 250 Vdc 10 5 5 a #14 to 1/0
60A switch 240 Vac 200 7.5 15 R #14 to 1/0
5 480 Vac 200 15 30 R, J #14 to 1/0
600 Vac 200 15 50 R, J #14 to 1/0
6 250 Vdc 10 10 10 a #14 to 1/0
100A switch 240 Vac 200 15 30 R #14 to 1/0
7 480 Vac 200 25 60 R, J #14 to 1/0
600 Vac 200 30 75 R, J #14 to 1/0
8 250 Vdc 10 20 20 a #14 to 1/0
200A switch b 240 Vac 200 25 60 R, T #4 to 300 kcmil
9 480 Vac 200 50 125 R, J, T #4 to 300 kcmil
600 Vac 200 60 150 R, J, T #4 to 300 kcmil
1 250 Vdc 10 40 40 a #4 to 300 kcmil
400A switch 240 Vac 200 50 125 R, T 250 to 750 kcmil or (2) 3/0 to 250 kcmil c
1 480 Vac 200 100 250 R, J, T 250 to 750 kcmil or (2) 3/0 to 250 kcmil c
600 Vac 200 125 350 R, J, T 250 to 750 kcmil or (2) 3/0 to 250 kcmil c
1 250 Vdc 10 50 50 a 250 to 750 kcmil or (2) 3/0 to 250 kcmil c
600A switch 240 Vac 200 75 200 R, T (2) #4 to 600 kcmil or (4) 3/0 to 250 kcmil
1 480 Vac 200 150 400 R, J, T (2) #4 to 600 kcmil or (4) 3/0 to 250 kcmil
600 Vac 200 200 500 R, J, T (2) #4 to 600 kcmil or (4) 3/0 to 250 kcmil
1 800A switch 240 Vac 200 N/A N/A T (3) 250 to 750 kcmil or (6) 3/0 to 250 kcmil
480 Vac 200 N/A N/A L, T (3) 250 to 750 kcmil or (6) 3/0 to 250 kcmil
1 600 Vac 200 N/A N/A L, T (3) 250 to 750 kcmil or (6) 3/0 to 250 kcmil
1200A switch 240 Vac 200 N/A N/A T (4) 250 to 750 kcmil or (8) 3/0 to 250 kcmil
1 480 Vac 200 N/A N/A L (4) 250 to 750 kcmil or (8) 3/0 to 250 kcmil
600 Vac 200 N/A N/A L (4) 250 to 750 kcmil or (8) 3/0 to 250 kcmil
1 NNote

1 a Contact fuse manufacturer for UL listed DC fuses.


b Switch type FDPB (breaker based).

1 c Lug size conversion kit available for: 1 x 750 kcmil (600A FDP), 2 x 750 kcmil (600A FDPW), 3 x 350 kcmil (600A CFDOW SW).

N/A = Not Applicable

1
1
1
1
1
1
1
1
1
1
1
9-74 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Surge Protection Devices


1
SPD Series Specifications 2
Description Specification
Surge capacity ratings available 50, 80, 100, 120, 160, 200, 250, 300, 400 kA per phase 3
Nominal discharge current (In) 20 kA
Short-circuit current rating (SCCR) 200 kA 4
SPD type Basic feature package = Type 1 (can also be used in Type 2 applications)
Standard and Standard with Surge Counter feature packages = Type 2 5
Single split-phase voltages available 120/240
Three-phase wye system voltages available 120/208, 127/220, 230/400, 277/480, 347/600 6
Three-phase delta system voltages available 240, 480, 600
Input power frequency 50/60 Hz 7
Power consumption (basic units):
208Y, 220Y, 240S, 240D and 240H voltage codes 0.5W 8
400Y, 480Y and 480D voltage codes 1.1W
600Y and 600D voltage codes 1.3W 9
Power consumption (standard and standard with surge counter units):
208Y, 220Y, 240S, 240D and 240H voltage codes 0.6W 1
400Y, 480Y and 480D basic voltage codes 1.7W
600Y and 600D voltage codes 2.1W 1
Protection modes Single split phase....................................... L-N, L-G, N-G, L-L
Three-phase wye........................................ L-N, L-G, N-G, L-L 1
Three-phase delta....................................... L-G, L-L

Maximum continuous operating voltage (MCOV):


Three-phase high-leg delta......................... L-N, L-G, N-G, L-L
1
240S, 208Y, 220Y and 240H MCOV
400Y and 480Y MCOV
150 L-N, 150 L-G, 150 N-G, 300 L-L
320 L-N, 320 L-G, 320 N-G, 640 L-L
1
600Y MCOV
240D MCOV
420 L-N, 420 L-G, 420 N-G, 840 L-L
320 L-G, 320 L-L
1
480D MCOV
600D MCOV
640 L-G, 640 L-L
840 L-G, 840 L-L
1
Ports 1
1
Operating temperature –4°F through 122°F (–20°C through 50°C)
Operating humidity 5% through 95%, noncondensing 1
Operating altitude Up to 16,000 ft (5000m)
Seismic withstand capability Meets or exceeds the requirements specified in IBC 2006, CBC 2007 1
Weight 50–200 kA units approximately 3.5 lbs (1.6 kg)

Form C relay contact ratings


250–400 kA units approximately 7.0 lbs (3.2 kg)
150 Vdc or 125 Vac, 1A maximum
1
Form C relay contact logic Power ON, normal state—NO contact = open, NC contact = closed
Power OFF or fault state—NO contact = closed, NC contact = open 1
EMI/RFI filtering attenuation Up to 50 dB from 10 kHz to 100 MHz
Agency certifications and approvals UL 1449 3rd Edition recognized component for the U.S. and Canada
1
UL 1283 (Type 2 SPDs only)
Warranty 10 years 1
1
Feature Package Comparison
Standard with 1
Feature Basic Standard Surge Counter
Surge protection using thermally protected MOV technology    1
Dual-coloured protection status indicators for each phase   
Dual-coloured protection status indicators for the neutral-ground protection mode    1
Audible alarm with silence button  
Form C relay contact   1
EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz  
Surge counter with reset button  1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 9-75
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Metering
1
2 Metering Selection Chart
Power Xpert® Meter Power Xpert Meter 2000 Series Power Xpert Meter 1000 Series IQ 250/260 Series
3 4000/6000/8000 Series

4
5 Device Name

6 Electrical Parameters
Volts 0.1% of reading + 0.02% FS 0.1% of reading 0.2% of reading 0.1% of reading

7 Amperes
Current range (% of nominal)
0.05% of reading + 0.01% FS
0.005–20A (400%)
0.1% of reading
0.1–200%
0.2% of reading
5 mA-50000 A (120-200%)
0.1% of reading
0.1–200%

8 Watts 0.1% of reading + 0.0025% FS 0.2% of reading 0.2% of reading 0.2% of reading
VARs 0.1% of reading + 0.0025% FS 0.2% of reading 0.2% of reading 0.2% of reading

9 VA 0.1% of reading + 0.0025% FS 0.2% of reading 0.2% of reading 0.2% of reading


PF-apparent 0.1% 0.2% of reading 0.2% of reading 0.2% of reading
1 PF-displacement 0.1% — — —
Frequency ±0.01 Hz ±0.03 Hz 0.2% Hz ±0.03 Hz
1 THD-voltage 127th 40th bcde 31st, 63rd lmn 40th f
THD-current 127th 40th bcde 31st (PXM 1000), 63rd 40th f
1 Watthours ±0.2% per ANSI C12.20 0.2 Class a ±0.2% per ANSI C12.20 0.2 Class ±0.2% per ANSI C12.20 0.2 Class ±0.2% per ANSI C12.20 0.2 Class
VAR-hours ±0.2% per ANSI C12.20 0.2 Class a ±0.2% per ANSI C12.20 0.2 Class ±0.2% per ANSI C12.20 0.2 Class ±0.2% per ANSI C12.20 0.2 Class
1 VA-hours ±0.2% per ANSI C12.20 0.2 Class a ±0.2% per ANSI C12.20 0.2 Class ±0.2% per ANSI C12.20 0.2 Class ±0.2% per ANSI C12.20 0.2 Class
Ampere-demand 0.05% of reading + 0.01% FS ±0.1% per ANSI C12.20 0.2 Class ±0.1% per ANSI C12.20 0.2 Class ±0.1% per ANSI C12.20 0.2 Class
1 Watt-demand ±0.2% per ANSI C12.20 0.2 Class a ±0.2% per ANSI C12.20 0.2 Class ±0.2% per ANSI C12.20 0.2 Class ±0.2% per ANSI C12.20 0.2 Class
VAR-demand ±0.2% per ANSI C12.20 0.2 Class a ±0.2% per ANSI C12.20 0.2 Class ±0.2% per ANSI C12.20 0.2 Class ±0.2% per ANSI C12.20 0.2 Class
1 VA-demand ±0.2% per ANSI C12.20 0.2 Class a ±0.2% per ANSI C12.20 0.2 Class ±0.2% per ANSI C12.20 0.2 Class ±0.2% per ANSI C12.20 0.2 Class
Revenue accuracy ±0.2% per ANSI C12.20 0.2 Class a ANSI C12.20 (0.2%) ±0.2% per ANSI C12.20 0.2 Class ANSI C12.20 (0.2%)
1 Individual ampere harmonics 85th g 40th cde 31st (PXM 1000), 63rd —
Individual voltage harmonics 85th g 40th cde 31st (PXM 1000), 63rd —
1 Interharmonics Yes hi — — —
Minimum and/or Maximum Values
1 Volts L-L, L-N, N-G, VAUX L-L L-L, L-N L-L, L-N L-L, L-N
Current A, B, C, N, G A, B, C, N A, B, C A, B, C
1 Power Watt, VAR, VA Watt, VAR, VA Watt, VAR, VA Watt, VAR, VA
Power Factor Apparent/displacement Apparent Apparent Apparent
1 Frequency Hz Hz Hz Hz
THD Amperes/volts (L-L, L-N, AUX L-L) Amperes/volts bcde Amperes/volts Amperes/volts f
1 Demand values kW, kVAR, kVA, amperes kW, kVAR, kVA, amperes kW, kVAR, kVA, amperes kW, kVAR, kVA, amperes
Trend analysis 2 / 4 h / 8 i GB 256 / 512 b / 768 cde MB 8 l m / 16 n MB
1
j

Event logging 2 / 4 h / 8 i GB 100,000 alarms/events with timestamp 8 MB n 128 KB k

1 Disturbance recording
Legend
2 / 4 h / 8 i GB, 60 cycles per event 768 MB up to 64 cycles per event de —
NNote

1

PG = Programmable
FS = Full scale
a Under typical operating
conditions.
f IQ 260 only.
g Individual values reported
h PXM 6000 only.
i PXM 8000 only.
l PXM 1100 only
m PXM 1200 only
RV = Read value b PXM 2260 only.
1 Auxiliary Voltage
(Optional) = Provides three
c PXM 2270 only.
to 85th harmonic; anti-alias
filtering prevents higher
j At computer only.
k Optional.
n PXM 1300 only

frequencies from distorting


additional voltage d PXM 2280 only.
1 inputs to the meter: e PXM 2290 only.
readings (see IEC 61000-4-7).
Va2, Vb2, Vc2
1 Interharmonics = Power Xpert Meter
6000/8000
supported
1
1
1
9-76 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Metering Selection Chart, continued


Power Xpert® Meter Power Xpert Meter 2000 Series Power Xpert Meter 1000 Series IQ 250/260 Series
1
4000/6000/8000 Series
2
3
Device Name 4
Other Features
Storage 2 / 4 a / 8 b GB 256 / 512 c / 768 def MB Standard8 MB j k / 16 MB l 128 KB for logging, up to 8 parameters 5
every 15 minutes for 30 days g
PG output relays 5 maximum Optional (2) Form C, 5 A or (4) Form A, KYZ Pulse and I/O Option Cards
120 mA
Optional (2) Form C, 5 A or (4) Form A,
120 mA
6
PG analogue outputs — Optional (4) 4–20 mA or (4) 0–1 mA Via I/O Option Card Output range:
0-5 V / 1-5 V, 0-20 mA / 4-20 mA
Optional (4) 4–20 mA or (4) 0–1 mA
7
(optional)
Accuracy: 0.5%
Temperature drift: 50ppm / °C typical
8
Isolation voltage: 500 Vdc
Open circuit voltage: 15 V 9
Discrete contact inputs 8 Optional (2) or (4) Via I/O Option Card Optional (2) or (4)
Input voltage range: 20–160 Vac/Vdc
Input current (max.): 2 mA 1
Start voltage: 15 V
Stop voltage: 5 V
Pulse frequency (max.): 100 Hz, 50%
1
duty ratio (5 ms ON and 5 ms OFF)
SOE resolution: 2 ms 1
Analogue inputs — — Input range: 0-5 V / 1-5 V, 0-20 mA / —
4-20 mA (optional)
Accuracy: 0.2%
1
Temperature drift: 50 ppm / °C typical
Isolation voltage: 500 Vdc 1
Synch-input kW utility Via status input Via end of interval pulse with — Via end of interval pulse with

Auxiliary voltage Yes


optional digital inputs
— Yes
optional digital inputs

1
kWh pulse initiator Yes Yes — Yes
Waveform display Local/computer h At computer — 1
Waveform capture, samples/cycle Yes, 512 (4096 oversampling) Yes, up to 64 e, up to 512 f Yes, up to 32 l —
Frequency distribution display — — — — 1
Display type LCD Red LED Backlit LCD Red LED
Display lines/character Graphic (320 x 240 pixels) 3 lines, 4 characters Main Display Area: 4 lines, 3 lines, 4 characters 1
4 characters
Bottom Display Area: 1 line,
9 characters 1
Display character height 5.5 mm H x 4 mm W 0.56 (14.2) H 1 line 0.56 (14.2) H
Communications Serial: Modbus® RTU, Modbus ASCII Serial: Modbus RTU, Modbus ASCII, Modbus® RTU, Modbus TCP Option, Serial: Modbus RTU, Modbus ASCII, 1
Network: Modbus TCP, Ethernet TCP/IP, DNP 3.0 BACnet/IP Option, Web/HTTP Push DNP 3.0
HTTP, SNMP, SMTP, FTP Network: Modbus TCP, BACnet/IP,
Ethernet
Option, Ability to connect to
Eaton’s Power Xpert Gateway 900 Gateway
Network: Modbus TCP via Power Xpert
1
TCP/IP, HTTP, HTTPS, SNMP, SMTP,
Waveform FTP ef 1
Setup configuration Via Web browser/display Via Web browser/display Via configuration software/ Via configuration software/display

Dimensions in inches (mm) Meter: 8.82 (224.0) H x 8.22 (208.8) W x 4.85 (123.2) H x 4.85 (123.2) W x
display/ Web Page
3.78 (96.0) H × 3.78 (96.0) W 4.85 (123.2) H x 4.85 (123.2) W x
1
6.72 (170.7) D 4.97 (126.2) D × 1.99 (50.7) D 4.97 (126.2) D
Display: 9.02 (229.1) H x 7.80 (198.1) W x
2.49 (63.2) D
1
Operating temperature range –20° to 60°C display unit
–20° to 70°C meter base unit i
–20° to 70°C -25° to 70°C –20° to 70°C
1
Reference literature TD02601007E TD02601017E TD026079EN TD02601016E
Legend NNote
1
a PXM 6000 only.
PG = Programmable
1
d PXM 2270 only. g Optional. j PXM 1100 only
FS = Full scale b PXM 8000 only. e PXM 2280 only. h At computer only. k PXM 1200 only
RV = Read value
c PXM 2260 only.
Auxiliary Voltage
(Optional) = Provides three
f PXM 2290 only. i Using <10 VA meter sourced
24V power.
l PXM 1300 only
1
additional voltage
inputs to the meter:
Va2, Vb2, Vc2
1
Interharmonics = Power Xpert Meter
6000/8000 1
supported

Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 9-77


Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Metering Selection Chart, continued


1 IQ Analyzer 6000 Series IQ DP-4000 Series IQ 230 Series

2
3
4 Device Name
Electrical Parameters
5 Volts ±0.2% FS a ±0.3% FS ±0.5% FS
Amperes ±0.2% FS a ±0.3% FS ±0.5% FS
6 Current range (% of nominal) 3–800% 10–250% 1–200%
Watts 0.4% FS, 6 Reading b ±0.6% FS ±1.0% FS
7 VARs 0.4% FS, 6 Reading c ±0.6% FS ±1.0% FS
VA 0.4% FS, 6 Reading b ±0.6% FS ±1.0% FS
8 PF-apparent 0.8% FS a ±1.0% FS ±2.0% FS

9 PF-displacement
Frequency
0.8% FS a
0.04% a or 0.01 Hz
±1.0% FS
±0.17% FS
±2.0% FS
±0.1% Hz

1 THD-voltage
THD-current
50th
50th
31st
31st

1 Watthours
VAR-hours
0.5% reading b
1% reading c
±0.6% FS
±0.6% FS
±1.0% per ANSI C12
±1.0% per ANSI C12

1 VA-hours
Ampere-demand
0.5% reading b
±0.2% FS a
±0.6% FS
±0.3%
±1.0% per ANSI C12
±0.5% per ANSI C12

1 Watt-demand
VAR-demand
±0.4% FS a
±0.4% FS a
±0.6%
±0.6%
±1.0% per ANSI C12
±1.0% per ANSI C12

1 VA-demand ±0.4% FS a ±0.6% ±1.0% per ANSI C12


Revenue accuracy ANSI C12.20 (0.5%) — ANSI C12.1 (1%)

1 Individual ampere harmonics 50th — —


Individual voltage harmonics 50th — —
1 Interharmonics — — —
Minimum and/or Maximum Values
1 Volts L-L, L-N L-L, L-N L-L, L-N
Current A, B, C, N, G A, B, C A, B, C
1 Power Watt, VAR, VA Watt, VAR, VA Watt, VAR, VA
Power factor Apparent/displacement Apparent/displacement Apparent/displacement
1 Frequency Hz Hz Hz
THD Amperes/volts Amperes/volts —
1 Demand values All All All
Trend analysis Time/date 2 alarms d
1 Event logging 504 events w/timestamp d d

Disturbance recording 10 waveform events — —


1 Legend NNote
PG = Programmable a From 3 to 300% of FS.
1 FS = Full scale b At unity power factory and
RV = Read value 5–300% of FS.
1 Auxiliary Voltage
(Optional) = Provides three
c At a power factor <±0.5 and

additional voltage 5–300% of FS.


1 inputs to the meter:
Va2, Vb2, Vc2
d At computer only.

Interharmonics = Power Xpert Meter


1 6000/8000 supported

1
1
1
1
9-78 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Metering Selection Chart, continued


IQ Analyzer 6000 Series IQ DP-4000 Series IQ 230 Series
1
2
3
Device Name 4
Other Features
Storage 90 KB 15 parameters — 5
PG output relays (4) 10 A Form C a (3) 10 A Form C b (2) 100 mA Form A
PG analogue outputs (4) 0–10/4–20 mA — —
6
Discrete contact inputs (3) +30 Vdc differential (1) kW demand b (2) +30 Vdc differential
Analogue inputs (1) 0–20/4–20 mA — (1) 4–20 mA
7
Synch-input kW Utility
Auxiliary voltage c
At device or via communications

At device or via communications b

Via communications only

8
kWh pulse initiator
Waveform display
Yes
Local b/computer
Yes b

Yes

9
Waveform capture, samples/cycle
Frequency distribution display
Yes, 128
Local b/computer




1
Display type
Display lines/character
Graphic LCD with LED backlight
7 lines, 147 characters
7 Segment LED
1 line, 7 characters
Backlit LCD
4 lines, 20 characters
1
Display character height
Communications
Up to 7 lines
Serial: INCOM d
1 line
Serial: INCOM d
1.60 (40.6) H x.09 (2.3) W
Serial: INCOM, Modbus RTU e
1
Network: via Power Xpert Gateway d Network: via Power Xpert Gateway d Network: via Power Xpert Gateway
Setup configuration Via configuration software/display Via configuration software/display Via configuration software/display
1
Dimensions in inches (mm)
Operating temperature range
6.70 (170.2) W x 10.30 (261.6) H x 5.40 (137.2) D f
–20° to 70°C
6.70 (170.2) W x 10.30 (261.6) H x 5.40 (137.2) D f
–20° to 70°C
Refer to TD.17.06.T.E
0° to 50°C
1
Reference literature —
NNote
— —
1
Legend


PG = Programmable
FS = Full scale
a Relays programmable to operate on any
measured function.
d An IPONI is required.
e IQ 230M only.
1
RV = Read value b Optional.
Auxiliary Voltage
c The auxiliary voltage option adds three
f Dimensions in mm =
170.2 W x 261.6 H x 137.2 D.
1
(Optional) = Provides three
additional voltage additional voltage input channels to
inputs to the meter: Power Xpert Meters. 1
Va2, Vb2, Vc2
Interharmonics = Power Xpert Meter
6000/8000 supported
1
1
1
1
1
1
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 9-79
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Metering Selection Chart, continued


1
Power Monitoring /
2 IQ 130/140/150 Series Power Xpert Meter 350 Series IQ 150S/250S Series Metering Module (PM3)

3
4
Device Name
5 Electrical Parameters
Volts 0.25% of reading 0.5% of reading 0.1% of reading ±0.5% of reading
6 Amperes 0.25% of reading 0.5% of reading 0.1% of reading ±0.5% of reading

7 Current range (% of nominal)


Watts
0.1–200%
0.5% of reading a
10 mA-500000 A (200 %)
0.5% of reading
0.1–200%
0.2% of reading

±1.0% of reading

8 VARs
VA
0.5% of reading a
0.5% of reading a
0.5% of reading
0.5% of reading
0.2% of reading
0.2% of reading
±1.0% of reading
±1.0% of reading

9 PF-apparent
PF-displacement
0.5% of reading a

0.5% of reading

0.2% of reading

±2.0% of reading

1 Frequency
THD-voltage
±0.03 Hz a

0.2% of reading

±0.03 Hz

±0.1 Hz

1 THD-current
Watthours

±0.5% per ANSI C12.20 0.5 Class b

±0.5% per ANSI C12.20 0.5 Class

±0.2% per ANSI C12.20 0.2 Class

±1.0% per ANSI C12.1

1 VAR-hours ±0.5% per ANSI C12.20 0.5 Class b ±0.5% per ANSI C12.20 0.5 Class ±0.2% per ANSI C12.20 0.2 Class ±1.0% of reading
VA-hours ±0.5% per ANSI C12.20 0.5 Class b ±0.5% per ANSI C12.20 0.5 Class ±0.2% per ANSI C12.20 0.2 Class ±1.0% of reading

1 Ampere-demand ±0.25% per ANSI C12.20 0.5 Class a ±0.25% per ANSI C12.20 0.5 Class ±0.1% per ANSI C12.20 0.2 Class —
Watt-demand ±0.5% per ANSI C12.20 0.5 Class a ±0.5% per ANSI C12.20 0.5 Class ±0.2% per ANSI C12.20 0.2 Class —
1 VAR-demand ±0.5% per ANSI C12.20 0.5 Class a ±0.5% per ANSI C12.20 0.5 Class ±0.2% per ANSI C12.20 0.2 Class —
VA-demand ±0.5% per ANSI C12.20 0.5 Class a ±0.5% per ANSI C12.20 0.5 Class ±0.2% per ANSI C12.20 0.2 Class —
1 Revenue accuracy ANSI C12.20 (0.5%) ±0.5% per ANSI C12.20 0.5 Class ANSI C12.20 (0.2%) ±1.0% per ANSI C12.1
Individual ampere harmonics — — — —
1 Individual voltage harmonics — — — —
Interharmonics — — — —
1 Minimum and/or Maximum Values
Volts L-L, L-N L-L, L-N L-L, L-N —
1 Current A, B, C A, B, C, N, (on Bi-Directional Energy Models) A, B, C, —
Power Watt, VAR, VA a Watt, VAR, VA Watt, VAR, VA —
1 Power factor Apparent a Apparent Apparent —
Frequency Hz a Hz Hz —
1 THD — — — —
Demand values kW, kVAR, kVA, amperes a kW, kVAR, kVA, amperes kW, kVAR, kVA, amperes —
1 Trend analysis c — 2 MB e —
Event logging c c 2 MB e —
1 Disturbance recording — — — —
NNote
1 Legend
PG = Programmable a IQ 140/150.
FS = Full scale b IQ 150 only.
1 RV = Read value
c At computer only.
Auxiliary Voltage
(Optional) = Provides three d Optional.
1 additional voltage e IQ 250S only.
inputs to the meter:
1 Va2, Vb2, Vc2
Interharmonics = Power Xpert Meter
6000/8000 supported
1
1
1
1
9-80 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

Metering Selection Chart, continued


Power Monitoring / Metering
1
IQ 130/140/150 Series Power Xpert Meter 350 Series IQ 150S/250S Series Module (PM3)
2
3
4
Device Name
Other Features 5
Storage — — 2 MB b —
PG output relays — KYZ Pulse output, Relay Output — — 6
PG analogue outputs — — — —
Discrete contact inputs — — — Circuit breaker status 7
Analogue inputs — — — —
Synch-input kW utility — — — — 8
Auxiliary voltage c — — — —
kWh pulse initiator a — Yes — 9
Waveform display — — — —
Waveform capture — — — —
1
Frequency distribution display — — — —
Display type Red LED Backlit LCD Red LED —
1
Display lines/character
Display character height
3 lines, 4 characters
0.56 (14.2) H
1 line, 6 characters
1 line
3 lines, 4 characters
0.56 (14.2) H


1
Communications Serial: Modbus RTU, Modbus -RTU, BACnet MS/ TP, Serial: Modbus RTU, Modbus ASCII, Serial: INCOM, Modbus RTU d
1
®

Modbus ASCII a Ability to connect to Eaton’s Power DNP 3.0 Network: via Power Xpert Gateway
Network: Modbus TCP a 4 Xpert Gateway 900 Network: Modbus TCP,
wired or wireless 1
Setup configuration Via configuration software/display Via configuration software/display Via configuration software/display —
Dimensions in inches (mm) 4.85 (123.2) H x 4.85 (123.2) W
x 4.97 (126.2) D
2.92 (74.0) D × 3.54 (90.0) H
× 4.25 (108.0) W
7.90 (200.7) H x 7.50 (190.5) W
x 3.10 (78.7) D
Refer to IL01219085E
–25° to 70°C
1
Operating temperature range
Reference literature
–20° to 70°C
TD02601016E
-25° to 70°C
TD150024EN
–20° to 70°C
TD02601019E


1
Legend NNote
a Optional.
1
PG = Programmable


FS = Full scale
RV = Read value
b IQ 250S only.
c The auxiliary voltage option adds three
1
Auxiliary Voltage
(Optional) = Provides three
additional voltage
additional voltage input channels to
Power Xpert Meters. 1
inputs to the meter: d Contact Eaton for availability.
Va2, Vb2, Vc2 1
Interharmonics = Power Xpert Meter
6000/8000 supported
1
1
1
1
1
1
1
1
1
1
Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca 9-81
Low Voltage Switchboards and Switchgear
Switchboard Accessories and Modifications

This page intentionally left blank.


1
2
3
4
5
6
7
8
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
9-82 Low Voltage Switchboards and Switchgear    CA015002EN—August 2019    www.eatoncanada.ca

Das könnte Ihnen auch gefallen