Sie sind auf Seite 1von 2

Gabunada, Almarian Gay M.

CE 2/L Software Application for CE


Engr. Charity Mae E. Farase

COMPUTATION OF LOADS
(Proposed 4-Storey Commercial Building)

LEVELS Height (m) Relative Height (m)

Footing to GF 1.5 1.5


GF to 2F 4.0 5.5
2F to 3F 3.8 9.3
3F to 4F 3.8 13.1
4F to RD 3.8 16.9

DEAD LOADS (In reference to NSCP 2015)

Dead Load 1 (DL1)


 Reference Load * Slab Thickness multiplied by the
 Selfweight (Concrete at 23.54 kN/m3) concrete density 23.54 kN/m3
 2.35 kN/m2 at 100 mm Slab Thickness (Floor Load) So, 0.1m x 23.54 kN/m3
= 2.35 kN/m2

Dead Load 2 (DL2)


 Reference Load
 3.35 kN/m2 (Floor Load - Floor Finish)
 7.08 kN/m (Member Load – Wall) 100mm thk. at GF to 2F
 6.75 kN/m (Member Load – Wall) 100mm thk. at 2F to 3F
 6.75 kN/m (Member Load – Wall) 100mm thk. at 3F to 4F
 6.75 kN/m (Member Load – Wall) 100mm thk. at 4F to RD

7.08 kN/m is calculated from 100mm wall with a unit weight of 16.5 kN/m3 multiplied by the wall
height 4.0m added by 0.48 using Tabele 204-2 of the NSCP 2015.
Therefore; 0.1 x 16.5 x 4.0 + 0.48 = 7.08 kN/m

6.75 kN/m is calculated from 100m wall with a unit weight of 16.5 kN/m3 multiplied by the wall height
3.8m added by 0.48 using Tabele 204-2 of the NSCP 2015.
Therefore; 0.1 x 16.5 x 3.8 + 0.48 = 6.75 kN/m

NSCP 2015 pg. 69


Table 204-2 Minimum Design Dead Loads (kPa)

LOADS CARRIED BY FLOOR FLOOR FLOAD IN kN/m2


Floor Finish 1.53
Ceiling 0.72
MEP (Mech, Elec, and Plumbing) 0.10
TOTAL 2.35
LIVE LOADS

OCCUPANCY DESIGN LOAD (kPa)


Rentable Spaces (Store) 4.8
Studio Type Rooms 1.9
Function Halls 4.8
Hallways 4.8
Roof Deck 1.9

SEISMIC PARAMETERS
Seismic Importance Factor, I Table 208 - 1 1.0
Seismic Zone Factor, Z Table 208 - 3 0.4
Rx Table 208 – 11A 8.5
Rz Table 208 – 11A 8.5
Soil Type Table 208 - 2 D
Na Table 208 - 5 1.0
Nv Table 208 - 6 1.2
Ct 0.0731

TABLES (In reference to NSCP 2010 – Chapter 2 Section 208)

Das könnte Ihnen auch gefallen