Sie sind auf Seite 1von 63

2&20m Telecom Site Survey

Report
Doc respons/Approved Checked Date Rev. File
Mohammed Alam

1 - INTRODUCTION :
PROJECT NAME : RISE PROJECT CUSTOMER : MOBILY
PROJECT MANAGER : BASIl OTHMAN COUNTRY : SAUDI ARABIA
SITE ID : 6459 DATE OF AUDIT : 1\30\2020

1.1 - SITE DETAILS


Site Picture

Site Pic 1 Site Pic 2(Door Label)

a) GENERAL
Site ID : 6459
Address : MAKKAH
GPS Coordinates (WGS84 decimal degrees) 21.349427 °N 39.784367 °E

b) TOWER
Site Type : Macro
Shelter Type: NORMAL
Civil Model: 12m RoofTop Tower
Pole/Tower Height : 12m
Building Height : 10

c) Security
Security Guard at Site No

Special Permit Required For Access No

Access details in Day / Night time


open
(if Yes, brief description)

Crane requirement ( if Yes, brief


No
description)
2 - ANTENNA SYSTEM DETAILS

2.1 - Existing 2G System


900Mhz 1800Mhz

Sec A Sec B Sec C Sec D Sec A Sec B Sec C Sec D

Antenna Type

No of
Antennas

Antenna
Azimuth

Antenna
Height
Electrical Tilt /
Mechanical
Tilt
Indoor Jumper
Length &
Type
Feeder Type /
Fiber
Feeder
no's,Length or
FO length

TMA (Yes/No)

RET Cable
length

Diplexer/Triplex
er (Yes/No) with
Qty

RRUS Type
(if any)

Bracket Type
of RRUS
Source of
Power for
RBS / RRUS
CB rating in
Amperes
CB Type
(ABB,
Emerson etc)
RBS Type &
Qty
BB Type
(sharing if
any)
Site
Configuration

Ant. Sharing
900/1800/3G/LTE
2.2 - Existing 3G System

2100Mhz U900

Sec A Sec B Sec C Sec D Sec A Sec B Sec C Sec D

RV4-65D- RV4-65D- RV4-65D- TBXLHA- TBXLHA- TBXLHA-


Antenna Type
R5-V6 R5-V6 R5-V6 6565C-VTM 6565C-VTM 6565C-VTM

# of Antennas 1 1 1 1 1 1

Antenna
Azimuth
60 180 280 60 180 280

Antenna
Height
22 22 22 22 22 22
Electrical Tilt /
Mechanical built in/0 built in/0 built in/0 RET/0 RET/0 RET/0
Tilt
Indoor Jumper
3m&1/2'' 3m&1/2'' 3m&1/2'' 3m&1/2'' 3m&1/2'' 3m&1/2''
Length &
OD OD OD OD OD OD
Type
Feeder Type /
Fiber
Fiber Fiber Fiber Fiber Fiber Fiber
Feeder
no's,Length or 2&50m 2&50m 2&50m 1&50m 1&50m 1&50m
FO length

TMA (Yes/No) no no no no no no

RET Cable
length
no no no 3m 3m 3m
Diplexer/Triplex
er (Yes/No) with yes 2 yes 2 yes 2 no no no
Qty

RRUS Type
(if any)
2x2219 B1 2x2219 B1 2x2219 B1 1*2219 B8 1*2219 B8 1*2219 B8

Bracket Type
of RRUS
RAIL RAIL RAIL RAIL RAIL RAIL
Source of
Power for Rectifier Rectifier
RBS / RRUS
CB rating in
Amperes
125A 125A
CB Type
(ABB, NADER NADER
Emerson etc)
RBS Type &
Qty
RBS 6150 &1 RBS 6150 &1
BB Type
(sharing if 1xBB6620 with U900 1xBB6620 with 3G
any)
Site
Configuration
2+2+2 1+1+1

Ant. Sharing
900/1800/3G/LTE with FDD\TDD\L800 SA
2.3 - Existing 4G System

LTE FDD LTE TDD

Sec A Sec B Sec C Sec D Sec A Sec B Sec C Sec D

RV4-65D- RV4-65D- RV4-65D- RV4-65D- RV4-65D- RV4-65D-


Antenna Type
R5-V6 R5-V6 R5-V6 R5-V6 R5-V6 R5-V6

# of Antennas 1 1 1 1 1 1

Antenna
Azimuth
60 180 280 60 180 280

Antenna
Height
22 22 22 22 22 22
Electrical Tilt /
Mechanical built in/0 built in/0 built in/0 built in/0 built in/0 built in/0
Tilt
Indoor Jumper
3m&1/2'' 3m&1/2'' 3m&1/2'' 3m&1/2'' 3m&1/2'' 3m&1/2''
Length &
OD OD OD OD OD OD
Type
Feeder Type /
Fiber
Fiber Fiber Fiber Fiber Fiber Fiber
Feeder
no's,Length or 3&50m 3&50m 3&50m 1&50m 1&50m 1&50m
FO length

TMA (Yes/No) no no no no no no

RET Cable
length
no no no 3m 3m 3m
Diplexer/Triplex
er (Yes/No) with yes 2 yes 2 yes 2 no no no
Qty

RRUS Type 2x2219 B1 + 2x2219 B1 + 2x2219 B1 +


(if any) 2×2219 B3 2×2219 B3 2×2219 B3
1*RRUS 72 1*RRUS 72 1*RRUS 72

Bracket Type
of RRUS
RAIL RAIL RAIL pole pole pole
Source of
Power for Rectifier Rectifier
RBS / RRUS
CB rating in
Amperes
125A 125A
CB Type
(ABB, NADER NADER
Emerson etc)
RBS Type &
Qty
RBS 6150 &1 RBS 6150 &1
BB Type
(sharing if BB6630 with TDD& L800 BB6630 with FDD&L800
any)
Site
Configuration
2+2+2 2+2+2

Ant. Sharing
900/1800/3G/LTE with 3G\L800\TDD with 3G\L800\FDD
2.4 - Existing 5G / L800 System

5G L800

Sec A Sec B Sec C Sec D Sec A Sec B Sec C Sec D

RV4-65D- RV4-65D- RV4-65D-


Antenna Type
R5-V6 R5-V6 R5-V6

# of Antennas 1 1 1

Antenna
Azimuth
60 180 280

Antenna
Height
22 22 22
Electrical Tilt /
Mechanical built in/0 built in/0 built in/0
Tilt
Indoor Jumper
3m&1/2'' 3m&1/2'' 3m&1/2''
Length &
OD OD OD
Type
Feeder Type /
Fiber
Fiber Fiber Fiber
Feeder
no's,Length or 1&50m 1&50m 1&50m
FO length

TMA (Yes/No) no no no

RET Cable
length
no no no
Diplexer/Triplex
er (Yes/No) with no no no
Qty

RRUS Type 1*2217 1*2217 1*2217


(if any) B20 B20 B20
Bracket Type
of RRUS
RAIL RAIL RAIL
Source of
Power for Rectifier
RBS / RRUS
CB rating in
Amperes
125A
CB Type
(ABB, NADER
Emerson etc)
RBS Type &
Qty
RBS 6150 &1
BB Type
(sharing if BB6630 with FDD&TDD
any)
Site
Configuration
1+1+1

Ant. Sharing
900/1800/3G/LTE with 3G\TDD\FDD
3 - EXISTING POWER SYSTEM
3.1 - DC POWER SYSTEM

DC Power (-48V)

Rectifier Available : yes Rectifier Operational : yes

Rectifier Type : EMERSON

Total rectifier modules 4

Available, not in use 0

Available no of PDU's & PDU slot in 3G Cabinet N\A

Current -48V DC Power Consumption : 118.0A\54.4V

Number of Free Rectifier's Position: 0

Fuse Holder/MCB Breaker Available :

CB Type / Fuse Type in the Holder ABB\NADER

GENERATOR DUAL : NO

GENERATOR SINGLE : NO

No GENERATOR : YES

SCECO POWER : YES

DC Power - 48V -DETAILS

Ampere Type Total Qty Spare

Fuse holder/MCB Breaker: 125 NADER 1 0

Fuse holder/MCB Breaker: 25 NADER 6 0

Fuse holder/MCB Breaker: 16 NADER 4 0

Fuse holder/MCB Breaker: 63 NADER 6 0

Fuse holder/MCB Breaker: 6 NADER 1 0

Fuse holder/MCB Breaker: 25 ABB 3 0

Fuse holder/MCB Breaker: 10 ABB 2 1

Power Cable (BTS -48V) :

Portable Power Supply needed:

Note
3.2 - AC POWER SYSTEM

Others
AC Power (220V)
Specify

MDB Available : MDB Operational :

MDB Type : MDB Input Power (V) :

MDB Size Existing Load (Amp) :

Power Source/Size (Power


Cable type)

SCECO POWER :

AC Power - MDB CIRCUIT BREAKER DETAILS

Technology Ampere Pole Type Type Spare

Fuse holder/Main
Circuit Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:

Power Cable (BTS AC) :

Portable Power Supply needed:

Note
4 - RF ENVIRONMENT DETAILS

4.1 - Location and Panoramic Analysis


Panoramic Pictures - Sector A

Panoramic Pictures - Sector B


Panoramic Pictures - Sector C

Panoramic Pictures - Sector D


4.2 - Outdoor Installation Details

Sector 1-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Full Tower view

Sector 1-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Zoomed view
Sector 2-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Full Tower view

Sector 2-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Zoomed view
Sector 3-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Full Tower view

Sector 3-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Zoomed view
Sector 4-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Full Tower view

Sector 4-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Zoomed view
5 - INDOOR AND OUTDOOR PICTURES

Tower Feeder System /Tray/Ladder Pictures


Tower Feeder System /Tray/Ladder Pictures
Shelter inside view 1 ( from door )

Shelter inside view 2 ( from door )


Existing Equipments - 2G

Existing Equipments - 3G
Existing Equipments - 4G

Existing Equipments - 5G / L800


External Alarms Avaialbe Type & Comments:

Current Float in Rectifier Additional Comments


Existing Equipments - Circuit Breaker panel Existing Equipments - Battery String

Existing Equipments - MDB (Door open ) Existing Equipments - TRM Rack


Existing equipments - Indoor Cable Ladder Existing equipments -IndoorCable Ladder

Earthing Indoor Earthing Outdoor


Roxtec Entry Indoor
Roxtec Entry Outdoor
Roxtec Info Roxtec 1 Roxtec 2 Roxtec 3
No of feeders
Dimension
No of IF cables 2

CB 1 2 3
No of CB 21
Used CB 20
Free CB 1

6 - TRANSMISSION DETAILS

6.1 - Existing Links

No. Far End Ant. Diameter (m) Height (m.a.g.l) Azimuth to FE(deg)

1
2
3
4
5
6
7
8

Definition of Terms

ACDB AC Distribution Box


ASC Antenna System Controller
BATB Building Alarm Termination Box
BSC Base Station Controller
DC Direct Current
DCDP DC Distribution Point
GSM Global System for Mobile Telecommunication
IF Intermediate Frequency
RBS Radio Base Station
RDU Rapid Deployment Unit
RET Remote Electrical Tilt
RF Radio Frequency
RNC Radio Network Controller
SB Square Base
TMA Tower Mounted Amplifier
TRM Transmission Rack
WiMAX Worldwide Interoperability for Microwave Access
WM Wall Mount
Telecom Site Survey Report
Doc respons/Approved Checked Date Rev. File
Mohammed Alam

PROJECT NAME : RISE PROJECT CUSTOMER : MOBILY


PROJECT MANAGER : BASIL OTHMAN COUNTRY : SAUDI ARABIA
SITE ID : 6459 DATE OF AUDIT : 1\30\2020

RISE MODEL & PHASE :

SCOPE (3xAIR6449 B41 + 2xBB6630 + 3xDiplexers + Dismantle 3xRadios + Dismantle 3xAntennas)+New R6672

Item Description Required (Yes/No ) Remarks

New RBS / Hybrid RBS No Existing RBS6150 to be used

Digital Unit / Baseband


Yes 2x new BB6630 to be installed inside Existing RBS6150
(DU/BB )
Exp
RBS6201/New
Pole for Enclosure(if any) No
RBS6601/Enclosur
e/Main Unit
19’’RACK / RBS6302 / Router Yes new R6672 to be installed

Circuit Breaker Yes 2x16A CB ABB for R6672 in Rectifier

ERS & its Location No

Pole (1m / 1.5m for ERS) No

Bracket Type No

ERS System

Circuit Breaker Yes Need 3x50A ABB CB for AIR6449 B41 in Rectifier

Cable Tray 100/300mm (for ERS) No

Cable Tray 100/300mm (for FO &


No
Power cables)

2G 900 / W900 / L800 Antenna No Existing Comscope PENTA Ant to be used for U900 with new 3* Diplexer (B8\B20)

LTE 800 Antenna No Existing Comscope PENTA Ant to be used for L800 with new 3* Diplexer (B8\B20)

LTE FDD 2100 / 3G 2100 No Existing Comscope PENTA Ant to be used with existing 6xDiplexer (B1\B3)

Antenna System

LTE FDD 1800 / 2G 1800 No Existing Comscope PENTA Ant to be used with existing 6xDiplexer (B1\B3)

LTE TDD Antenna Yes new AIR6449 B41 Ant to be installed

5G Antenna Yes new AIR6449 B41 to be installed

Mounts for Antenna / ERS ( If any ) No

Minor Civil Work


Cable Tray / Roxtec No
required

DCDP No

Additional
Information
MAIN UNIT : PROPOSAL

Existing RBS6150 to be used


Proposed/Existing RBS Location

Proposed DU/BB/RBS6601 Location 2x new BB6630 to be installed insided Existing RBS6150 after Dismantling free DCDB
Doc respons/Approved Checked Date Rev. File
Mohammed Alam

PROJECT NAME : RISE PROJECT CUSTOMER : MOBILY


PROJECT MANAGER : BASIL OTHMAN COUNTRY : SAUDI ARABIA
SITE ID : 0 DATE OF AUDIT : 00-01-00

RISE MODEL & PHASE :

SCOPE

Item Description Required (Yes/No ) Remarks

New RBS / Hybrid RBS

Digital Unit / Baseband


(DU/BB )
Exp
RBS6201/New
Pole for Enclosure(if any)
RBS6601/Enclosur
e/Main Unit

19’’RACK / RBS6302 / Router

Circuit Breaker

ERS & its Location

Pole (1m / 1.5m for ERS)

Bracket Type
ERS System

Circuit Breaker

Cable Tray 100/300mm (for ERS)

Cable Tray 100/300mm (for FO &


Power cables)

2G 900 / W900 / L800 Antenna

LTE 800 Antenna

LTE FDD 2100 / 3G 2100

Antenna System

LTE FDD 1800 / 2G 1800

LTE TDD Antenna

5G Antenna

Mounts for Antenna / ERS ( If any )

Minor Civil Work


Cable Tray / Roxtec
required

DCDP

Additional
Information
MAIN UNIT : PROPOSAL

Proposed/Existing RBS Location

Proposed DU/BB/RBS6601 Location


Rise Model & Phase

ANTENNA- RRU : PROPOSALS - 1

PROPOSED TECHNOLOGY (5G Introduction)

Sector A : Antenna Type & Location new AIR6449 B41 to be installed in location TBXLHA-6565C-VTM & shift TDD to new AIR6449 B41

PROPOSED TECHNOLOGY
Req RET cable
Sector A : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY (5G Introduction)

Sector B : Antenna Type & Location new AIR6449 B41 to be installed in location TBXLHA-6565C-VTM & shift TDD to new AIR6449 B41

PROPOSED TECHNOLOGY
Req RET cable
Sector B : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY (5G Introduction)

Sector C : Antenna Type & Location new AIR6449 B41 to be installed in location TBXLHA-6565C-VTM & shift TDD to new AIR6449 B41

PROPOSED TECHNOLOGY
Req RET cable
Sector C : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY

Sector D : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector D : Proposed Radio Type and Location
Rise Model & Phase

ANTENNA- RRU : PROPOSALS - 2

PROPOSED TECHNOLOGY

Sector A : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector A : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY

Sector B : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector B : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY

Sector C : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector C : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY

Sector D : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector D : Proposed Radio Type and Location
Rise Model & Phase

ANTENNA- RRU : PROPOSALS - 3

PROPOSED TECHNOLOGY

Sector A : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector A : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY

Sector B : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector B : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY

Sector C : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector C : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY

Sector D : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector D : Proposed Radio Type and Location
POWER : PROPOSAL

MDB Type & Location Need 3x50A ABB CB for AIR6449 B41 in Rectifier

New MDB / Circuit Breaker Proposed Location Need 3x50A ABB CB for AIR6449 B41 in Rectifier
Battery : PROPOSAL

Existing Battery Location Battery on Rectifier

Battery Proposed Location


Rectifier : PROPOSAL

Existing Rectifier EMERSON

Rectifier Proposed Location


CABLE TRAY/ ROXTEC : PROPOSAL

Cable Tray Location & Space Availability for Fiber and Power Existing to be used
Clamps

Roxtec Location and Space availability Existing to be used


CABLE TRAY/ ROXTEC : PROPOSAL

Indoor Routing of Fibers / Power

New Cable Tray Proposed Location


CABLE TRAY/ ROXTEC : PROPOSAL

New Cable Tray Proposed Location

Proposed Roxtec Location


ROXTEC / CABLE TRAY : PROPOSAL

Proposed Indoor Routing of Fiber / Power

Proposed Indoor Routing of Fiber / Power


Doc respons/Approved Checked Date Rev. File
Mohammed Alam

PROJECT NAME : RISE PROJECT CUSTOMER : MOBILY


PROJECT MANAGER : BASIL OTHMAN COUNTRY : SAUDI ARABIA

SITE ID : 6459 DATE OF AUDIT : 1\30\2020

RISE MODEL &


0
PHASE

SCOPE (3xAIR6449 B41 + 2xBB6630 + 3xDiplexers + Dismantle 3xRadios + Dismantle 3xAntennas)+New R6672

Site ID 6459 ANTENNA DIAGRAM - 1

ITEMS TO BE DISMANTLED

Item Description Type Qty Serial No Tag No Comments

1 TBXLHA-6565C-VTM ANT 3
2 RRU72 RADIO 3
3
4
5
6
7
8
9
#
#
#
#
ITEMS TO BE DISMANTLED
ITEMS TO BE DISMANTLED
ITEMS TO BE DISMANTLED
Doc respons/Approved Rev. File
Checked Date
Mohammed Alam

PROJECT NAME : RISE PROJECT CUSTOMER : MOBILY

PROJECT MANAGER : BASIL OTHMAN COUNTRY : SAUDI ARABIA


SITE ID : 0 DATE OF AUDIT : 00-01-00

RISE MODEL &


0
PHASE

SCOPE 0

Site ID 0 ANTENNA DIAGRAM - 2

ITEMS TO BE DISMANTLED

Item Description Type Qty Serial No Tag No Comments

1
2
3
4
5
6
7
8
9
#
#
#
#
ITEMS TO BE DISMANTLED
ITEMS TO BE DISMANTLED
ITEMS TO BE DISMANTLED
SITE ID : 6459

RF ENVIRONMENT DETAILS
Location and Panoramic Analysis
Panoramic Pictures - 0 Degree

Panoramic Pictures - 30 Degree


Panoramic Pictures - 60 Degree

Panoramic Pictures - 90 Degree


Panoramic Pictures - 120 Degree

Panoramic Pictures - 150 Degree


Panoramic Pictures - 180 Degree

Panoramic Pictures - 210 Degree


Panoramic Pictures - 240 Degree

Panoramic Pictures - 270 Degree


Panoramic Pictures - 300 Degree

Panoramic Pictures - 330 Degree


Site Access / Damages / Missing items / other issues at site pictures