Sie sind auf Seite 1von 6

PLYCEM FLOOR/ CEILING ASSEMBLIES

• Fire and sound results •


SUMMARY

FIRE PERFORMANCE

REPORT SCOPE APPLICABLE STANDARD LABORATORY RESULTS

1 Hour Fire Rating Assembly resists


SWRI Standard Test Methods for Fire Tests Southwest Research
Design for Floor/ ASTM E - 119 one hour of
01-3689-001 Building Construction and Materials Institute
Ceiling Assemblies exposure to fire

1) Single Layer 3/4" SteelCem Panel


2) Floor Joist 8J18 @ 24"
3) Furring Channel @ 24"
4) 2 layers 5/8" type "G" Gypsum Board
5) 3-5/8" - SW-16 Web Stiffner

REPORT SCOPE APPLICABLE STANDARD LABORATORY RESULTS

2 Hour Fire Rating Assembly resists 2


SWRI Standard Test Methods for Fire Tests Southwest Research
Design for Floor/ ASTM E - 119 hours of exposure
01-3689-002 Building Construction and Materials Institute
Ceiling Assemblies to fire

1) Single Layer 3/4" SteelCem Panel


2) Floor Joist 8J18 @ 24"
3) 1" Mineral Wool
4) 2 layers 5/8" type "G" Gypsum Board
5) Two inch high 20 gauge galvanized steel "Z" sections
6) 3-5/8" - SW- 16 Web Stiffner

REPORT SCOPE APPLICABLE STANDARD LABORATORY RESULTS

1.5 Hour Fire Rating Assembly resists


Standard Test Methods for Fire Tests
V100 - 391 Design for Floor/ ASTM E - 119 Vtec Laboratories Inc. 1.5 hours of
Building Construction and Materials
Ceiling Assemblies exposure to fire

1) Plycem Board 3/4"


2) Floor Joist 8J18 @ 24"
3) 4" Mineral Wool
4) 5/8" (15.9 mm) Gypsum Firecode C
5) Furring Channel @ 24"
6) 3-5/8" - SW- 16 Web Stiffner

Búsquenos en: / Experto Plycem • www.plycem.com


PLYCEM FLOOR/ CEILING ASSEMBLIES
• Fire and sound results •
SUMMARY

REPORT SCOPE APPLICABLE STANDARD LABORATORY RESULTS

1 Hour Fire Rating Assembly resists 1


Standard Test Methods for Fire Tests
3115-11-07 Design for Floor/ ASTM E - 119 Ramtech Laboratories hour of exposure
Building Construction and Materials
Ceiling Assemblies to fire

1) Plycem Cemdeck Panel, 1" (25 mm)


2) Prescient Floor Joist
3) Single leg resilient Furring Channel, 1/2" x 25Ga.
4) Mineral Wool Insulation, 4" (density 4 pcf)
5) 5/8" Type X Gypsum Board

REPORT SCOPE APPLICABLE STANDARD LABORATORY RESULTS

2 Hours Fire Rating Assembly resists 2


Standard Test Methods for Fire Tests
3115-11-07 Design for Floor/ ASTM E - 119 Ramtech Laboratories hours of exposure
Building Construction and Materials
Ceiling Assemblies to fire

1) Plycem Cemdeck Panel, 1" (25 mm)


2) Prescient Floor Joist
3) Single leg resilient Furring Channel, 1/2" x 25Ga.
4) Mineral Wool Insulation, 4" (density 4 pcf)
5) Two layers of 5/8" Type X Gypsum Board

Búsquenos en: / Experto Plycem • www.plycem.com


PLYCEM FLOOR/ CEILING ASSEMBLIES
• Fire and sound results •
SUMMARY

ACOUSTICAL PERFORMANCE

REPORT SCOPE APPLICABLE STANDARD LABORATORY RESULTS

Impact Sound Standard Test Methods for Laboratory IIC (Impact


Measurement of Impact Sound
3115-11-07 Transmission in Floor/ ASTM E - 492 Ramtech Laboratories Insulation Class):
Transmission Through Floor - Ceiling
Ceiling Assemblies Assemblies Using The Tapping Machine 69

1) Carpet & Pad over 25 mm Plycem


2) Prescient Truss
3) Resilient Channel
4) Mineral Wool Insulation
5) One Layer 5/8" Gypsum

REPORT SCOPE APPLICABLE STANDARD LABORATORY RESULTS

Impact Sound Standard Test Methods for Laboratory IIC (Impact


Measurement of Impact Sound
3115-11-07 Transmission in Floor/ ASTM E - 492 Ramtech Laboratories Insulation Class): 51
Transmission Through Floor - Ceiling
Ceiling Assemblies Assemblies Using The Tapping Machine

1) Laminate Floor over 25 mm Plycem


2) Prescient Truss
3) Resilient Channel
4) Mineral Wool Insulation
5) One Layer 5/8" Gypsum

Búsquenos en: / Experto Plycem • www.plycem.com


PLYCEM FLOOR/ CEILING ASSEMBLIES
• Fire and sound results •
SUMMARY

REPORT SCOPE APPLICABLE STANDARD LABORATORY RESULTS

Impact Sound Standard Test Methods for Laboratory IIC (Impact


Measurement of Impact Sound
3115-11-07 Transmission in Floor/ ASTM E - 492 Ramtech Laboratories Insulation Class):
Transmission Through Floor - Ceiling
Ceiling Assemblies Assemblies Using The Tapping Machine 66

1) Carpet & Pad over 25 mm Plycem


2) Prescient Truss
3) Resilient Channel
4) Mineral Wool Insulation
5) Two Layer 5/8" Gypsum

REPORT SCOPE APPLICABLE STANDARD LABORATORY RESULTS

Impact Sound Standard Test Methods for Laboratory IIC (Impact


Measurement of Impact Sound
3115-11-07 Transmission in Floor/ ASTM E - 492 Ramtech Laboratories Insulation Class):
Transmission Through Floor - Ceiling
Ceiling Assemblies Assemblies Using The Tapping Machine 52

1) Laminate Floor over 25 mm Plycem


2) Prescient Truss
3) Resilient Channel
4) Mineral Wool Insulation
5) Two Layer 5/8" Gypsum

Búsquenos en: / Experto Plycem • www.plycem.com


PLYCEM FLOOR/ CEILING ASSEMBLIES
• Fire and sound results •
SUMMARY

REPORT SCOPE APPLICABLE STANDARD LABORATORY RESULTS

Sound Transmission Standard Test Methods for Laboratory STC (Sound


Measurement of Airborne Sound
3115-11-07 Class in Floor/ Ceiling ASTM E - 90 Ramtech Laboratories Transmission
Transmission Loss of Building Partitions
Assemblies and Elements Class): 55

1) Carpet & Pad over 25 mm Plycem


2) Prescient Truss
3) Resilient Channel
4) Mineral Wool Insulation
5) One Layer 5/8" Gypsum

REPORT SCOPE APPLICABLE STANDARD LABORATORY RESULTS

Sound Transmission Standard Test Methods for Laboratory STC (Sound


Measurement of Airborne Sound
3115-11-07 Class in Floor/ Ceiling ASTM E - 90 Ramtech Laboratories Transmission
Transmission Loss of Building Partitions
Assemblies and Elements Class): 56

1) Laminate Floor over 25 mm Plycem


2) Prescient Truss
3) Resilient Channel
4) Mineral Wool Insulation
5) One Layer 5/8" Gypsum

Búsquenos en: / Experto Plycem • www.plycem.com


PLYCEM FLOOR/ CEILING ASSEMBLIES
• Fire and sound results •
SUMMARY

REPORT SCOPE APPLICABLE STANDARD LABORATORY RESULTS

Sound Transmission Standard Test Methods for Laboratory STC (Sound


Measurement of Impact Sound
3115-11-07 Class in Floor/ Ceiling ASTM E - 90 Ramtech Laboratories Transmission
Transmission Through Floor - Ceiling
Assemblies Assemblies Using The Tapping Machine Class): 57

1) Carpet & Pad over 25 mm Plycem


2) Prescient Truss
3) Resilient Channel
4) Mineral Wool Insulation
5) Two Layer 5/8" Gypsum

REPORT SCOPE APPLICABLE STANDARD LABORATORY RESULTS

Sound Transmission Standard Test Methods for Laboratory STC (Sound


Measurement of Impact Sound
3115-11-07 Class in Floor/ Ceiling ASTM E - 90 Ramtech Laboratories Transmission
Transmission Through Floor - Ceiling
Assemblies Assemblies Using The Tapping Machine Class): 57

1) Laminate Floor over 25 mm Plycem


2) Prescient Truss
3) Resilient Channel
4) Mineral Wool Insulation
5) Two Layer 5/8" Gypsum

Búsquenos en: / Experto Plycem • www.plycem.com