Name of Organization :  TELESONIC NETWORKS LTD.

HUB:- South Circle:- AP

Site GIS Code:- City:- HYD

Network Element Type:- LA/SA/TPT/SITEDEV Type Of Work:-

Area/ Segment:- Fibre

Name of the Customer:- Garden Housing

Full Address :-
Suchitra, Hyderabad

Topic: Site Survey for Airtel FTTH-ODN,Hyd


Site Name: Garden Housing

Site Address: Suchitra, Hyderabad

BUILDING DETAILS:
Completetion Completetion
S.No. BLOCK SHAFT
Status Timeline
1 ROSE A 3 Yes NIL
2 ROSE B 3 Yes NIL
3 JASMINE A 2 Yes NIL
4 JASMINE B 2 Yes NIL
5 JASMINE C 2 Yes NIL
6 LILLY A 2 Yes NIL
7 LILLY B 2 Yes NIL
8 LILLY C 2 Yes NIL
9 TULIP A 1 Yes NIL
10 TULIP B 1 Yes NIL
11 TULIP C 1 Yes NIL
12 TULIP D 1 Yes NIL
13 TULIP E 1 Yes NIL
14 TULIP F 1 Yes NIL
15 ORCHID 1 Yes NIL
16 MARI GOLD 1 Yes NIL
17 R BLOCK 1 Yes NIL

Airtel Participant/s: Teja Builder Side:


Remarks:

"
Capex Approval Qt

NFA Number:- AOP 2019-20

W.O.NO.:- AP/HYD/CAPEX/FTTX/FTTH/B2C/HR/IBW/061119/0229

WO Issued Date:- 6-Nov-19 Tags 912

WO Start Date:- 7-Nov-19 End Date:- 21-Nov-19

Approx Route Kms 3.67 Site Code

Survey Date:
Survey Ref: Airtel FTTH-

Case Ref: Mail request dated-

Flat Shaft
Floor-Nos. Flats/Floor Total Flats BHK-No.
Area Position
8 18 144 NA
8 18 144
8 8 64
8 8 64
8 8 64
8 8 64
8 8 64
8 8 64
7 4 28
7 4 28
7 4 28
7 4 28
7 4 28
7 4 28
7 4 28
5 5 8
5 5 8
884
Participant/s::
der Side:
Inputs:
Permission:
1. Airtel to confirm keeping of materials at site &
start of work.
2. Airtel to confirm permission to use cable tray from
builder.
912

Nov-19

REMARK
ing of materials at site &

mission to use cable tray from


Site Name
Site Address
S. No.
2
6

11

12

15

27

31
32
34
S. No
4
10
11
14
17

23

25
32
35
36
40
Garden Housing
Suchitra,Hyderabad
Item Description: MATERIALS
Splitters for ODF / Rack compatible with connectors - PLC Type - 1.5 Mtr Length. - SC-APC 2:8
Splitters for FAT Boxes Cassette (Insert / Blade) Splitters with connectors - SC-APC 1:8
FAT Box should have splice tray , provision for cable entry, cable terminations, cable mgmt, patch cord mgmt and cassette
splitters. - IP55 Compliant with Wall Mountable & Pole Mountable accessories - 16F
FAT Box should have splice tray , provision for cable entry, cable terminations, cable mgmt, patch cord mgmt and cassette
splitters. - IP55 Compliant with Wall Mountable & Pole Mountable accessories - 32F
ODF (144F) with Cabinet ( Outdoor/Indoor) with SC-APC adapters and pigtails, with Vert/Horz Patch cord Mgmt, Patching
& splicing Tray, provision of cable entry and terminations, splitter provision
Single Mode 12 F - (G.652D) LSZH Sheath Micromodule Riser Lite Optical Fiber Cable ( Fiber Make : Sterlite, Corning ,
Furukawa, Sumitomo )
OFC : Unarm : 24 Fibre Wet dry
OFC : Arm : 48 Fibre Wet Dry
HDPE Duct 40MM- Grey
Description: SERVICES
ODF-144F INST PACH/SPLIC MGMT & S&I CONCRET PLINTH
FAT-16F BOXES INST. WITH SPLITTER & SPLICING.
Installation of FAT Boxes - Spliced Version with Splitters and splicing as per site requirement 32F BOX
FMS-24F INS.WTH SC-PC/SCAPC PACHING,SPLCING,CABLE
TRENCHING & DIGGING BT/RCC CUTTING UPTO 0.6M DEPTH
OFC Laying /pulling inside the HDPE duct / PVC Conduit - upto 96 F (Includes Feeder and Raiser and Drop Fiber Cable)

FIBER PULLING & SPLICING IN OLD/ EXISTING DUCTS


TESTING & DOCUMENTATION OF HOME PASS > 150 HP
40MM PVC ARM FLEXIBLE CONDUIT INCL. LAYING
IF PVC CONDUT NOT USD,INST.OF DUCT WITH OUT JUNCTON BOX
Flixble Pipe 40 mm
Home Pass 884
Type Highrise,Flat
U/M Item Code Unit Price Quantity Final Price
Nos TNL003671 480 8 3840
Nos TNL003675 400 58 23200

Nos TNL003680 1250 56 70000

Nos TNL003681 1450 29 42050

Set TNL003667 10800 2 21600

Kms TNL002051 28800 0.57 16416

kms OFC000021 25683 2.1 53934.3


kms OFC000022 43729 1 43729
kms DUC000058 32100 2.5 80250
UOM Item Code Unit Price Quantity Final Price
Nos TNL004398 8000 2 16000
Nos TNL004400 900 56 50400
Nos TNL004401 1300 2 2600
Nos TNL004404 2300 27 62100
Mtr TNL004413 270 20 5400

Mtrs TNL004409 11 3170 34870

No TNL000203 18 500 9000


Nos TNL004422 6500 1 6500
Mtrs TNL004418 120 450 54000
Mtrs TNL003664 35 2500 87500
Mtrs TNL002614 80 200 16000
Supply 355019.3
Service 344370
Total 699389
Cost Per HP 791
GARDEN HOUSIN
P.S S.S
Sl No Tower Shaf Floors Flats/ Floor Total H.P
2:8 1:8

1 ROSE A 3 8 18 144 9
2 ROSE B 3 8 18 144 9
3 JASMINE A 2 8 8 64 4
4 JASMINE B 2 8 8 64 4
5 JASMINE C 2 8 8 64 4
6 LILLY A 2 8 8 64 4
7 LILLY B 2 8 8 64 4
8 LILLY C 2 8 8 64 4
9 TULIP A 1 7 4 28 8 2
10 TULIP B 1 7 4 28 2
11 TULIP C 1 7 4 28 2
12 TULIP D 1 7 4 28 2
13 TULIP E 1 7 4 28 2
14 TULIP F 1 7 4 28 2
15 ORCHID 1 7 4 28 2
16 MARI GOLD 1 5 5 8 1
17 R BLOCK 1 5 5 8 1
Total 27 122 884 8 58
EN HOUSING(884 HP)
Primary Primary Secondar
Placement of Splitters ODF FMS Duct cable cable y Riser
Primary Secondary Splitter 144F 24F 40mm 24F 48F 12F
Splitter
ODF2 Fat 3
ODF2 3
ODF2 2
ODF1 2
ODF1 2
ODF1 2
ODF1 2
ODF1 2
ODF2 2 1 2500 2100 1000 570
ODF2 1
ODF2 1
ODF1 1
ODF1 1
ODF1 1
ODF2 1
ODF1 1
ODF2 1
2 27 2500 2100 1200 570
PVC Conduits

40 mm

450

450