15EE54T Electrical Estimation & Costing Student Activity (PART_C-03) 2018-2019

Government CPC Polytechnic Mysuru


Department of Electrical & Electronics

Group-5) A Drawing Hall of a College is to be provided with electrical connection for lights,
fans, and sockets etc. in conduit system of wiring. You are required to

 Design and plan suitable electric installation of the drawing hall and show the same
on the plan.
 Decide the number of circuits.
 Calculate the size and quantity of the wires and its accessories required.
 Calculate the materials required giving specification of each item.

Prepare the list of materials required with specification and estimate the cost. Assume any
missing data with suitable justifications.
STAFF
ROOM
3mX4m
DIAS

DRAWING HALL
40 m

15 m

Register Number: Name: Signature:


15EE54T Electrical Estimation & Costing Student Activity (PART_C-04) 2018-2019

Government CPC Polytechnic Mysuru


Department of Electrical & Electronics

Group-5) A machines laboratory of an engineering department has the following

installation layout. A 3phase, 415 V, 50Hz power supply is to be given to it.


Prepare a wiring diagram showing the location, distance of all control
equipments, motors and cables. Determine the ratings of all protective devices
and type of starter required. Suitably assume any missing data with
justifications.
Load details:
Motor
A1,B1,M1,N1 A5,B5,M5,N5 A2, B2,A4,B4 A3,B3
Name
Supply 3Ф 3Ф 3Ф 1Ф
Hp Ratings 5 10 1 0.5

3m

3m
A1 B1 M1 N1

4m
A2 B2

2m

A3 B3
20 m

A4 B4

3m
A5 B5 M5 N5

19 m

Register Number: Name: Signature:


15EE57P Estimation Simulation Lab Student Activity 2018-2019

Government CPC Polytechnic Mysuru


Department of Electrical & Electronics

Group-5) A large industry is fed by a 11KV supply.It has two blocks. The load details of the
blocks are as follows:

 Block-1: ten 100 hp motors with 0.75pf,five 15hp motors with 0.7pf, 200 light points
 Block-2: fifteen heating points each of 25KW 0.75pf, 50 light points

You are required to:

 Describe the power distribution in the form of single line diagram


 Segregate the load
 Decide the number of circuits
 Decide the rating of transformer
 Prepare the single line schematic wiring diagram in the simulation software.
 Calculate the size and quantity of the wires and rating of the protective devices.
 Design the capacitor bank rating to maintain a power factor of 0.9
 Prepare the material estimate with complete specifications.

Assume any missing data with suitable justifications.