Sie sind auf Seite 1von 27

DESIGN &

I N S TA L L AT I O N
GUIDE

Soil &
Waste

marleypd.co.uk
Innovation & Expertise PVCu Soil and Waste Systems

Marley Plumbing & Drainage offer a comprehensive


range of soil and waste systems. Available with
a variety of jointing methods and manufactured
to UK and European standards and are designed
for use on commercial and residential projects.

Product specification information


Key
This guide contains design and
installation information for Marley ABS = Acrylonitrile butadiene styrene
PVCu soil & waste drainage systems.
PVC-c = Chlorinated Polyvinyl Chloride
All documentation can be
downloaded from marleypd.co.uk PVCu = Poly vinyl chloride un-plasticised
PP = Polypropylene

BS EN ISO 9001:2008
BS EN ISO 14001:2004

Contents

4 Marley soil & waste systems 27 WC connectors


6 Solvent waste – PVCu 29 WC manifold system
8 Solvent waste – ABS 32 Design
10 Push-fit waste – PP 40 Installation data
12 Condense and Overflow system 47 Site work
14 Push-fit soil – PVCu 48 British & European Standards
19 Solvent soil – PVCu 50 Technical services
25 Accessories 51 Marley system solutions

2 | MARLEY PVC Soil & Waste MARLEY PVC Soil & Waste | 3
Life4 Marley Soil & Waste Systems
PVCu soil and waste systems HDPE soil

The HDPE soil range is certified to BS EN 1519: 2000


The PVCu soil system is available in 82, 110 (licence number KM 545820) An extension of the
and 160mm push-fit and solvent weld options Marley soil & waste portfolio, the HDPE range offers
incorporating socketed and plain ended pipe. an alternative solution to cast iron.
110 and 160mm pipe support components have It is particularly suited for commercial applications
been designed specifically to support horizontal or where a product with high impact or abrasion
or vertical suspended PVCu pipework. resistance is required, such as hospitals, hotels,
Pipes and fittings are also suitable for use schools, as well as residential buildings.
as internal and external rainwater pipes to
drain flat roofs and metal gutter systems
on commercial and industrial buildings.

Waste ranges *

Compression
Solvent waste Push-fit waste Overflow Traps
waste
PVCu ABS Polypropylene PVCu Polypropylene Polypropylene

S uitable for Lightweight and F or internal use,  complete


A  ulti-fit
M  range of traps,
A
internal and cost effective ideally suited to range of compression which enable
external for internal fast installation. pipework socket, for quick & easy
applications. installation. Cost effective and fittings internal use. installation to any
Easy to cut solution where for overflow Easy installation new or existing Key fitting: Aerator
joint and install. systems are being and boiler to similar sized plastic or copper
installed condensate new or existing pipework. The need for secondary venting in high-rise buildings can be eliminated with the aerator. An aerator fitting breaks
or modified. applications. plastic and the discharge fall on each floor and as a consequence the secondary vent pipe is not required as the pressure
copper pipework. difference stays well within the limit of 3 mbar.
Available in Available in Available in Available in Available in Available in
32, 40 and 50 mm 32, 40 and 50 mm 32, 40 mm 21.5 mm 32, 40 mm 32, 40 and 50 mm The unique shape of the fitting increases the capacity of the stack allowing the soil and waste flow from the
higher floors to smoothly converge with the flow on the lower floor.
White & Black White, Black White, Black White White & Chrome White & Chrome
& Grey & Grey

* For information on Multikwik compression waste and traps visit marleypd.co.uk.


ABS and polypropylene waste pipes and fittings are designed for internal use and should not be fitted externally
as they will be subject to ultraviolet light degradation. If fitted externally it is recommended that they are protected
by the application of a suitable paint or are boxed in. dBlue Acoustic soil
Features and benefits Key product information: An acoustic soil and waste range with a layered
• Push-fit or solvent weld jointing • 82mm, 110mm and 160mm Soil sizes pipe providing quick, hygienic removal of sanitary
• Light weight • 32mm, 40mm and 50mm Waste sizes waste water. The noise generated by the flow of
water is dramatically reduced – making it perfect
• Easy to handle on site
Typical applications: for multi-occupancy apartment blocks and high
• Quick and easy to install, saving time and money specification developments.
• Apartments
• Provides quick and hygienic removal of sanitary
waste water • Hotels
• All collar bosses are individually pressure tested • Libraries
to ensure joint integrity • Hospitals
• Hole saw locator on all bosses for ease of • Public buildings
installation • Restaurants EN14366
16dB
Noise measurement

• Residential properties

4 | MARLEY PVC Soil & Waste MARLEY PVC Soil & Waste | 5
B
C
A
A

A
A
A

Solvent waste – PVC-c B

C
B
A
C
B
C
B
B
A
A B
D
A

A
B
C B A C

PIPE BENDS
B B
Size mm Code Length Colour Qty Size mm Code Angle A B C D Colour Qty
B A
C
32 KP104 4m WB 10 40 KBK25 90° 48 48 23 23 WB 20
C
A 40 KP204 4m WB 10 50 KBK35 90° 59 50 20 28 W 10
A A
50 KP304 4m WB 5 
D Knuckle bend/boss adaptor, which can solvent weld over a boss upstand
B

A B
Double spigot
A
C B B
Size mm Code Angle A B Colour Qty
B
32 KBS1 87½° 92 18 W 20
STRAIGHT COUPLINGS
40 KBS2 87½° 92 23 W 20
Size mm Code A B Colour Qty C
A 50 KBS3 87½° 92 30 WBG 10
B
32 KSC1 46 20 WB 60 A
A
A B Solvent socket/spigot
40 KSC2 53 24 WB 30 B
50 KSC3 66 28 WB 30 TEES B
B Size mm Code Angle A B Colour Qty
A
A 32 KT1 88½° 92 57 WB 30
B 40 KT2 88½° 106 62 WB 20
B B A 50 KT3 88½° 135 78 A WB 10
C B Size mm Code A B C Colour Qty B
A
32 KEC1 86 61 20 W 10 B
C
D

A 40 KEC2 90 64 23 W 10
B
50 KEC3 82 50 30 W 10 Size mm Code Angle A B Colour Qty
A A

A Expansion/adaptor
A D 40 KT21 45° 117 78 W 20
C B
A
A B 50 KT31 45° 149 100 W 10
B
PIPE CLIPS C
A
Size mm Code A B Colour Qty A
B CROSS TEE
C B 32 KF1 57 30 WBG 100 Size mm Code Angle A B Colour Qty
B B
40 KF2 62 30 WBG 100 B
A
40 KXT21 88½° 106 62 W 10
50 KF3 77 41 WBG 80 C
A A
50 KXT31 88½° 140 87 W 10
A B
Open clip B
B
A Size mm Code A B Colour Qty C
E A
B A
32 WC3 76 30 WB 100 A

C B A ACCESS PLUG 76
D
40 WC4 82 30 WB 100 D C
C B Size mm Code A B C Colour Qty
50 WC5 100 38 W 80
AC 32 KAP1 22 53 8 WB 10
B Closed clip A A 40 KAP2 25 57 8 WB 10
B
B B
BENDS 50 KAP3 33 71 8 WB 10
A
SOCKET REDUCER
Size mm Code Angle A B Colour Qty B
B Size mm Code A B Colour Qty
A B
32 KB1 88½° 57 18 WB 50 C A 32-21.5 KR175 22 20 W 100
40 KB2 88½° 62 21 WB 30 A
40-32 KR210 28 22 WB 80
A 50 KB3 88½° 78 28 WB 10
B 50-32 KR310 32 28 W 40
C A BB 50-40 KR320 32 28 WB 40
A
B Solvent spigot/socket
IRON ADAPTORS
A
B
Size mm Code Angle A B Colour Qty Female
AA
B C B Size mm Code A B C Colour Qty
32 KB12 45° 29 18 WB 10 B
A 40 KB22 45° 33 21 WB 20 32 KFA1 50 25 20 W 10
50 KB32 45° 42 28 WB 20 40 KFA2 53 25 24 W 10
C B
A A 50 KFA3 60 25 28 W 10
A
Solvent socket/BSP thread
B A
B
Male
Size mm Code Angle A w Colour Qty A
B CC B Size mm Code A B C Colour Qty
A
32 KBA12 45° 24 23 W 40
B 32 KMA1 44 20 20 W 50
40 KBA22 45° 35 26 W 20
40 KMA2 47 20 24 W 40
A 50 KBA32 45° 39 30 WBG 20
A A 50 KMA3 53 20 28 W 40
Spigot B C
B C B Solvent socket/BSP thread

PVCc Solvent weld pipe is manufactured to BS EN 1566 PVCc Solvent weld pipe is manufactured to BS EN 1566 CAD drawing available to download from marleypd.co.uk
6 | MARLEY PVC Soil & Waste B C MARLEY PVC Soil & Waste | 7
PVCu Solvent weld fittings are manufactured to BS 5255 PVCu Solvent weld fittings are manufactured to BS 5255 A
A A A
B
C

Solvent waste – ABS B


A
B
B

B
A
A
A

A
B
B

A
PIPE A
ACCESS PLUG
Size mm Code Length Colour Qty Size mm Code A B C Colour Qty
C B
B
32 WAP33 3m WBG 10 32 WAA3 22 53 8 WBG 10
B
40 WAP43 3m WBG 10 40 WAA4 25 57 8 WBG 10
C B
C B 50 WAP53 3m WBG 5 50 WAA5 33 71 8 WBG 10
B A
AA
B
C
A
TEES A
STRAIGHT COUPLINGS A A
B Size mm Code Angle A B Colour Qty
Size mm Code A B Colour Qty
B
B 32 WAT3 88½° 90 55 WBG 30
C B 32 WAC3 40 20 WBG 40
A 40 WAT4 88½° 107 64 WBG 20
40 WAC4 46 23 WBG 30
B 50 WAT5 88½° 140 86 WBG 10
50 WAC5 63 30 WBG 30
A B
A

A
BB A
B
C B Size mm Code A B C Colour Qty

A 32 WAC31 86 61 20 W 10 A Size mm Code Angle A B Colour Qty


B 40 WAC41 90 64 23 W 10 B 32 WAT31 45° 102 65 W 20
A
50 KEC3* 82 50 30 W 10 C A 40 WAT41 45° 117 79 W 20
A
A A 50 WAT51 45° 150 100 W 10
Expansion/copper adaptor A
B
B
PIPE CLIPS C
Size mm Code A B Colour Qty A
C B C B
B
32 KF1 57 30 WBG 100 CROSS TEE B
40 KF2 62 30 WBG 100 CA
C B Size mm Code Angle A B Colour Qty
A
50 KF3 77 41 WBG 80 B
A 40 WAT42 88½° 106 65 W 10
A B
A Open clip B 50 WAT52 88½° 140 88 W 10
C A
BB A
Size mm Code A B Colour Qty A

A
B 32 WC3 76 30 WBG 100 B
A
40 WC4 82 30 WBG 100 A
A 50 WC5 100 38 W 80 SOCKET REDUCER
B B C
Closed clip Size mm Code A B Colour Qty
B
A
40-32 WAR43 26 20 WBG 80
BENDS B C
50-32 WAR53 31 20 WBG 40
B Size mm Code Angle A B Colour Qty
B A 50-40 WAR54 31 23 WBG 40
32 WAB3 88½° 55 20 WBG 50 A
CA B
BA B
40 WAB4 88½° 64 23 WBG 30 IRON ADAPTORS
B A
B
50 WAB5 88½° 86 30 WBG 20 C
A Female
A C B
B Size mm Code A B C Colour Qty
A A
A
Size mm Code Angle A B Colour Qty
32 WAF3 50 25 25 W 10
A A 40 WAF4 53 25 24 W 10
B B 32 WAB31 45° 32 20 WBG 40 C B
A 50 WAF5 60 25 28 W 10
40 WAB41 45° 36 23 WBG 20 B
B 50 WAB51 45° 47 30 WBG 20
A
Male
A B
B C
Size mm Code A B C Colour Qty
AB

Size mm Code Angle A B Colour Qty A 32 WAM3 44 20 20 W 50


B A A
32 WAB32 45° 45 20 W 30 40 WAM4 47 20 24 W 40
B B C
40 WAB42 45° 48 23 W 20 50 WAM5 53 20 28 W 40
B AA
Spigot
A
B C
A
A CAP AND LINING A
B
Size mm Code A Colour Qty
B Size mm Code Angle A B Colour Qty
B 32 WAM31 58 W 10
32 WAB33 90° 44 20 WBG 30 A
C B
40 WAB43 90° 53 23 WBG 20 A
B A
A A
Knuckle bend B

A
A
A A
8 | MARLEY PVC Soil & Waste ABS Solvent weld system is manufactured to BS EN 1455-1 *PVCu ABS Solvent weld system is manufactured to BS EN 1455-1 CAD drawing
B
available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 9
B
A
B

Push-fit waste – PP
B
A

A A

C B
A
B

PIPE TEE
Size mm Code Length Colour Qty Size mm Code Angle A B Colour Qty
A
A 32 WPP33 3m WBG 10 32 WPT31 88½° 105 63 WBG 10
C B B
40 WPP43 3m WBG 10 40 WPT41 88½° 115 68 WBG 30

STRAIGHT COUPLING
Size mm Code A B Colour Qty A
B
32 WPC3 66 38 WBG 10 ACCESS PLUG
B
40 WPC4 69 38 WBG 20
B Size mm Code A Colour Qty
A
A 32 WPA31 20 WBG 100
A 40 WPA41 20 WBG 100
PIPE CLIPS
A
Size mm Code A B Colour Qty
A
BB B
32 KF1 57 30 WBG 100
40 KF2 62 30 WBG 100
A
Open clip SOCKET REDUCER
A A
Size mm Code A B Colour Qty
B
40-32 WPR43 45 36 WBG 10
B Size mm Code A B Colour Qty
B
A
C B
32 WC3 76 30 WBG 100
40 WC4 82 30 WBG 100 A
B
B
A A Closed clip

BENDS
A
A A
B

B B MULTI-FIT COMPONENTS
Size mm Code Angle A B Colour Qty
B Size mm Code A B C Required Colour Qty
hole size
32 WPB31 45° 42 42 WBG 20
AB C 32 WUM33 86 56 24 42 G 10
40 WPB41 45° 43 43 WBG 20
A A 40 WUM43 86 58 24 50 G 20
B Push-fit sockets
Fit BS EN 1451, BS EN 1455 or BS EN 1566 pipe. Straight tank connector
B A

Size mm Code Angle A B Colour Qty


B
A
32 WPB32 45° 36 31 WBG 10
A 40 WPB42 45° 36 32 WBG 20
B B
A

B B A
Size mm Code Angle A B Colour Qty

32 WPB33 90° 60 60 WBG 10


B
A A 40 WPB43 90° 65 65 WBG 20
Knuckle bend

B A
B
Size mm Code Angle A B Colour Qty

A 32 WPB34 88½° 75 37 WBG 10


A 40 WPB44 88½° 75 37 WBG 30
A
B

marleypd.co.uk

Push-fit PP system is manufactured to BS EN 1451. PP cannot be solvent welded.


10 | MARLEY PVC Soil & Waste Push-fit PP system is manufactured to BS EN 1451. PP cannot be solvent welded CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 11
A
B
B

Condense and Overflow system – PVCu A


B AC

A
B
B

B C
A
A

A
B

B A
B
A B C
PIPE
Size mm B Code
C Length Colour Qty
A
A A
21.5 OP213 3m W 30

Marley co-ex soil


B
B 21.5 OP21
A 4m W 30
B
A
A
A
A
STRAIGHT COUPLING
B
Size mm

21.5
Code
A
B
OSC21
A

28 13
B Colour

W
Qty

10
110mm soil pipe
with at least 30%
B
B A
B
A
A
A A
PIPE CLIP A

B
Size mm Code
A
A
A B Colour Qty
recycled content*
B C 21.5 OC21
A
44 14 W 10
A
A
A Marley 110mm soil
BENDS
A
B
Size mm Code
A
Angle A Colour Qty
pipe now combines the
AA
B

A
BA C
A
21.5
C OB90
A
B
90° 25 W 10
environmental benefits
B
A
AB

Size mm AA
Code Angle A Colour Qty
of using recycled
B C
A
A A
21.5
C
OB45
B
45° 13 W 10
material with the
A

TEE
Size mm Code Angle A B C Colour Qty
quality and aesthetic
A
B B

advantages of
A
B
21.5 OT90
AA
90° 50 25 21.5 W 10
A
AB C C
A

co-extrusion technology.
A B
A
C
B B
B A
A A
ADAPTORS B A
A
A
A
B AC
C
Female iron B • BS EN 1329 certified
SizeC mm Code A B C Colour Qty

A
A
21.5 OFA21 47 23 19 W 70
• Higher gloss levels
B
B A
B Straight, to 22mm
A
A B A
B
• Improved weathering performance
Size mm Code A B Colour Qty
A C
A 21.5 OCA21B 39 13 W 150
A A C
C • Available in grey and black
B A

A Cap and lining


A
B A B B
Size mm Code A Colour Qty
• Same list price as standard white pipe
21.5 OCL21 46 W 100
A
A
A
C
• Colour matched to all standard 110mm
TANK CONNECTORS
Marley soil fittings
B A B
Straight
A Size mm Code A Colour Qty
A B
A A C 21.5 OTC21 50 W 10
A A C
A Bent
A
Size mm Code Angle A B C Colour Qty
B A
B
A 21.5 OBC90 90° 48 25 13 W 10
C

A Including polyethylene washers and quick fix Acme threads

12 | MARLEY PVC Soil & Waste


A
PVCu overflow is manufactured to BS EN 806-4 * Please note the substrate may vary in colour due to recycled content MARLEY PVC Soil & Waste | 13
AA
A

Push-fit soil – PVCu

A
B
B
C

B
C

D
PIPE ADJUSTABLE BENDS
Size mm Code Length A B Colour Qty Size mm Code Angle A B C Colour Qty

A
A

82 SP303 3m 100 76 BG 156 82 SB37 11-87½° 195 187 49 BG 10


B 82 SP304 4m 100 76 G 156 Push-fit socket/spigot

110MM CO-EX SOIL


C B Size mm Code Angle A B C Colour Qty

B
C
A 110 SP4025 2.5m 128 70 BG 100 D
110 SB46 5-14° 125 135 82 G 4
110 SP403 3m 128 70 WBG 2
110 SP404 4m 128 70 G 100 Push-fit socket/spigot

D
160 SP603 3m 182 107 G 46
Size mm Code Angle A B C D Colour Qty
160 SP604 4m 182 107 G 46
A

Push-fit socket 110 SB47 21-90° 189 187 90 127 BG 4


B
B Push-fit socket/spigot
STRAIGHT COUPLINGS C

C
B C
C Loose pipe socket A

C B
Size mm Code A B C Colour Qty
D Size mm Code Angle A B C D Colour Qty
A 82 SE300 103 50 48 BG 30 A

110 SE400 109 61 48 WBG 8 160 SB67 31-90° 285 275 96 184 G 2
B
160 SE600 190 107 77 G 4 Push-fit socket/spigot
A
B
Double ring seal slip coupling
OFFSET BENDS
Size mm Code A B Colour Qty A
C
Size mm Code Angle A B C Colour Qty
82 SE305 104 49 BG 30 C
C A 110 SNE405 67½° 94 91 60 WBG 4
110 SE405 128 64 BG 8 A

160 SE605 170 83 G 4 D C


B Push-fit solvent socket
A A
B B

B
Triple socket B
Size mm Code A B Colour Qty

B C
110 SE402 311 82 G 4 B Size mm Code Angle A B C Colour Qty

A
A C C
82 SNE300 67½° 98 86 57 BG 30
A
A
160 SNE600 67½° 178 182 88 G 140
SHORT RADIUS BENDS
B Push-fit solvent socket
Size mm Code Angle A B C Colour Qty

82 SB31 87½° 138 115 49 BG 20 C


A
A 110 SB41 87½° 158 157 70 WBG 4 B

160 SFB61 87½° 242 232 88 G 1


Push-fit socket/spigot EQUAL BRANCHES
A B
A
C
Size mm Code Angle A B C D Colour Qty
Size mm Code Angle A B C Colour Qty
A B 110 SY401 87½° 299 150 60 175 W B G 4
82 SB35 45° 76 73 49 BG 20 160 SY601 87½° 438 245 96 260 G 2
B
110 SB45 45° 84 89 62 WBG 4
Push-fit sockets/spigot
B
160 SFB65 45° 120 118 85 G 2
B B A
C
C
Push-fit socket/spigot
D
C
Size mm Code Angle A B C Colour Qty

110 SB410 10° 98 75 60 WBG 4


110 SB420 20° 104 81 60 WBG 4
Size mm Code Angle A B C Colour Qty
110 SB430 30° 76 90 60 WBG 4
A
Push-fit socket/spigot 82 SY36 45° 229 130 55 G 10
A A
A C 110 SY460 45° 285 198 62 BG 4
A
C 160 SY63 45° 400 200 90 G 2
B B
Push-fit sockets/spigot
B
Size mm Code Angle A B C Colour Qty
B
B 110 SB411 88½° 135 145 60 BG 4
C
C 76 A
Double push-fit socket
D
C

14 | MARLEY PVC Soil & Waste To BS 4514 and / or BS EN 1329 'B' as appropriate CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 15
A
A
C
C
B

A A A

Push-fit soil – PVCu


C
A
A B
C
B

B B

EQUAL BRANCHES CORNER BRANCH


C C
Size mm Code Angle A B C Colour Qty C B Size mm Code Angle A B C D Colour Qty

A 110 SY466 45° 282 198 62 BG 4 110 SY411£ 87½° 287 143 60 175 G 4
C
A
A D Push-fit sockets/solvent socket A Push-fit sockets/spigot
C D
A
A B
C

B
B
BOSS PIPES C
Size mm Code Angle A B C Colour Qty
FIVE BOSS BRANCHES
B F
B
110 SW41 87½° 204 86 82 WBG 4
Size mm Code Angle A B C D Colour Qty C
B E A Push-fit socket/spigot. 1x40mm boss connection
B

D
110 SY405 87½° 287 143 60 175 WBG 4 A
C

C
C
Push-fit sockets/spigot A A
E B A
C A
B
76 A C Size mm Code Angle A B C Colour Qty
B
C
D
C
110 SW415 87½° 204 86 82 BG 4
A
D
Push-fit socket/spigot. 1x32mm boss connection
B

B
A
Size mm Code Angle A B C D Colour Qty
A

SYS415 110 SYS415 87½° 280 143 60 168 BG 4 BOSS PIPES C


B

Size mm Code Angle A B C Colour Qty


A Push-fit sockets/spigot
76 A
82 SW30 90° 202 101 49 BG 15
D
C B C
Push-fit socket/spigot. 3 boss upstands, 1 drilled
C

THREE BOSS BRANCH


Size mm Code Angle A B C D Colour Qty A
B C

82 SY33F 87½° 212 122 52 121 B G 10 B Size mm Code Angle A B C Colour Qty
A
B
Push-fit sockets/spigot B
110 SW40 90° 244 123 70 WBG 4
B
A
A Push-fit socket/spigot. 4 boss upstands
SYS405 65
D
B
C A
A
UNEQUAL BRANCHES 76
C
D
Size mm Code Angle A B C Colour Qty
ACCESS PIPES C

C
B A Size mm Code A B C Colour Qty
160x110 SY64 87½° 337 175 175 G 2
CC B
82 SF31 205 101 52 BG 15
Push-fit sockets/spigot. 2 boss/access upstands A

A Push-fit socket/spigot
A
A B

B B
C
B

C D
UNEQUAL BRANCHES Size mm Code A B C D Colour Qty
C
Size mm Code Angle A B Colour Qty
A B 110 SF41 244 123 70 152 B G 4
B 160x110 SY66 45° 335 306 G 2
A Push-fit socket/spigot. 3 boss upstands
Push-fit sockets/spigot B
C
A

A
REAR ACCESS BENDS
D
Size mm Code Angle A B C Colour Qty

DOUBLE BRANCH C A
110 SB42 87½° 138 146 55 BG 4
Size mm Code Angle A B C D Colour Qty A B Push-fit socket/spigot
B
110 SY404 87½° 288 141 54 76 G 4
C
Push-fit sockets/spigot. 4 boss branch
B
C B Size mm Code A B C Colour Qty
A
D
C
82 SB38 124 127 57 BG 1

A
Push-fit socket/spigot
D

16 | MARLEY PVC Soil & Waste To BS 4514 and / or BS EN 1329 'B' as appropriate CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 17

B
B A
A

Push-fit soil – PVCu Solvent soil – PVCu


C

B
A

REAR ACCESS BRANCHES PIPE


B A
Size mm Code Angle A B C D Colour Qty 110MM CO-EX SOIL
110 SY402 87½° 287 143 60 175 B G 4 Size mm Code Length Colour Qty
Push-fit socket/spigot 110 SL403 3m WBG 100
C 4 boss upstands
110 SL404 4m G 100
76 A
160 SL603 3m G 46
D 160 SL604 4m G 46
C
Double spigot

STRAIGHT COUPLINGS
REAR ACCESS BRANCHES
B C
Size mm Code Angle A B C D Colour Qty
B C Loose pipe socket
B
Size mm Code A B C Colour Qty
82 SY34F 87½° 212 121 52 101 B G 6
B 82 SE300 103 50 48 BG 30
Push-fit socket/spigot A
C
110 SE400 109 61 48 WBG 8
76 A
160 SE600 190 107 77 G 4
A
A A A
D
C
B
B
Double solvent socket
C
BOSS CONNECTOR B
A Size mm Code A B C Colour Qty
C
B
B Size mm Code Angle A B Colour Qty 82 SES301 93 44 82 G 50
B
32 SA411 87½° 43 21 WBG 50 C 110 SES401 102 50 124 BG 8
A
40 SA421 87½° 43 21 WBG 40 160 SES601 174 64 128 G 4
A B
50 SA420 87½° 66 45 BG 40 EXPANSION COUPLING
C B
A
Solvent weld with push-fit seal
B
A
LEVEL INVERT REDUCERS C Solvent socket ring seal adaptor
A

Size mm Code A B C Colour Qty Size mm Code A B C Colour Qty


B A
B
110x82 SRM304 192 78 82 BG 20 110 SE409 105 20 52 BG 8
B A
Spigot/socket B To accommodate thermal movement in both vertical and horizontal solvent pipework

B
A A
C A
A

A
B

B
Size mm Code A B C Colour Qty
A SHORT RADIUS BENDS B
160x110 SRM604 219 90 82 G 4 C
Size mm Code Angle A B C Colour Qty
A C
Push-fit spigot/socket
B

A 110 SBS41 87½° 162 168 50 G 4


C
A
C

CONCENTRIC REDUCER Solvent socket/spigot


Size mm Code A B Colour Qty A

B
110-50 SE41 105 135 BG 18 Size mm Code Angle A B C D Colour Qty
B
A Spigot to boss upstand C B 110 SBS42 87½° 149 149 47 119 B G 4
A D
C
160 SBS62 87½° 186 186 66 G 2
B
ECCENTRIC REDUCER D Double solvent socket

Size mm Code A B C Colour Qty B C

C
160-110 SRS604 168 68 20 G 6
A A
B
C A Spigot/socket
C A
B A Size mm Code Angle A B C Colour Qty

110 SBS45 45° 76 76 52 BG 4


B
C
A 160 SBS65 45° 98 98 66 G 2
B B
ADAPTOR C Double solvent socket
C
B A Size mm Code A B C Colour Qty
C C
B A 110 SA42 130 65 130 B 40
B Soil to drain adaptor A
A A A

Size mm Code Angle A B C Colour Qty

B
C
B 110 SBS415 45° 76 89 52 BG 4
Size mm Code A B C Colour Qty C B
160 SBS615 67½° 168 175 76 G 2
C B B
110 SA110 58 25 34 B 10 Solvent socket/spigot
B B
B C
A A Waste to drain adaptor D
A B
A C D
A
C
A
18 | MARLEY PVC Soil & Waste To BS 4514 and / or BS EN 1329 'B' as appropriate CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 19
110mm 500mm
110mm 500mm
Solvent soil – PVCu

A
C

B
LONG RADIUS BEND EQUAL BRANCHES

A
Size mm Code Angle A B C D Colour Qty

B
Size mm Code Angle A B C D Colour Qty

A
B
B
B

110 SBS40 87½° 114 240 48 110 W B G 4 160 SYS601 87½° 270 180 66 205 G 2
Solvent socket/spigot Triple solvent socket

B
D

B
A
A
D
C C

C
A

C
D
C

C
OFFSET BENDS B

Size mm Code Angle A B C Colour Qty Size mm Code Angle A B C D Colour Qty
B

110 SNE405 67½° 76 61 60 WBG 4 A 110 SY415 87½° 279 135 55 175 B G 4
C
A Push-fit / solvent socket SYS415 D
Double solvent socket/spigot. 5 Boss upstands
C A
76

D
C
B

UNEQUAL BRANCHES
Size mm Code Angle A B C Colour Qty Size mm Code Angle A B C Colour Qty
82 SNE300 67½° 88 48 49 BG 30 160 SYS644 45° 286 169 55 G 4
C
A
160 SNE600 67½° 178 182 96 G 140
Triple solvent socket
Push-fit / solvent socket
A
C

B
B
B

EQUAL BRANCHES
Size mm Code Angle A B C Colour Qty B Size mm Code Angle A B C D Colour Qty

E A 110 SYS460 45° 277 135 55 BG 4 160 SYS664 87½° 234 132 52 118 G 4
D Solvent sockets/spigot Solvent sockets
C
A
A
C D

C
B

B DOUBLE BRANCH
Size mm Code Angle A B C Colour Qty Size mm Code Angle A B C D Colour Qty
SYS415 110 SYS466 45° 274 135 55 BG 4 B 110 SYS404 87½° 274 133 45 76 G 4
160 SYS666 45° 362 194 66 G 4
76
A C Solvent sockets, 4 boss upstands
A Triple solvent socket
D
C
C
A
D

CORNER BRANCH
Size mm Code Angle A B C D Colour Qty
B Size mm Code Angle A B C Colour Qty
110 SYS405 87½° 272 135 55 168 B G 4 110 SYS411£ 87½° 272 135 55 G 1
SYS405 B
Triple solvent socket. 5 Boss upstands Solvent sockets. 1 boss upstand
C

A
76
D
A
C

20 | MARLEY PVC Soil & Waste To BS 4514 and / or BS EN 1329 'B' as appropriate CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 21
C
A
BA
B

Solvent soil – PVCu A


C

C
C F

A C

BOSS PIPES A B 8-WAY COLLAR BOSS


B Size mm Code Angle A B C Colour Qty Size mm Code A B C D E F G H Colour Qty
C F

110 SWS4135 45° 186 93 145 G 4 E


C
A 110 SCBL41 184 146 140 164 61 204 532 70 G 1
B

Solvent sockets. 3 x 50mm boss upstands H


Solvent socket/spigot with 350mm spigot tail
A
B E A
B
Size mm Code Angle A B C Colour Qty
G

C 110x32 SWS415 87½° 170 85 52 WBG 4


F
A Solvent sockets. 1 x 32mm push-fit boss connection
C
C B FG
G

C C
Size mm Code Angle A B C Colour Qty
D

A 110x40 SWS41 87½° 170 85 52 WBG 4 BOSS PIPES E A


B
BA Solvent sockets. 1 x 40mm boss connection Size mm Code Angle A B C Colour Qty
B B A D
C 110 SWS40 90° 179 92 55 BG 4
E A
B 160 SWS60 90° 200 100 66 G 4
A
Size mm Code Angle A B C Colour Qty D
B Double solvent socket. 4 boss upstands, 1 drilled
110x50 SWS42 87½° 170 85 52 BG 4
Solvent sockets. 1 x 50mm drilled boss connection
D
C Size mm Code Angle A B C D Colour Qty
STRAP-ON-BOSS 110 SWS405 90° 179 92 54 BG 4
A
Required A
Size mm Code Angle A B Colour Qty Solvent socket/spigot. 4 boss upstands, 1 drilled
hole size
B
B A 32x110 SWS4150 90° 70 55 50 BG 40 B C
F
B A 40x110 SWS410 90° 70 62 50 BG 40 C
50x110 SWS420 90° 86 75 63 BG 30
A A
D Size mm Code Angle A B C D Colour Qty
Push-fit boss connection
110 SWS406 90° 184 55 87 60 G 4
B
A C
B Push-fit/Solvent socket. 4 boss upstands
E A
CONDENSATE STRAP-ON-BOSS C
B
B

Size mm Code Angle A B Required hole size Colour Qty A


Size mm Code Angle A B C Colour Qty
B A 21.5x110 SWS4C 90° 70 21.5 57 G 50
160 SW60 90° 335 110 96 G 4
B C
D
Solvent socket/spigot
A B 4 boss upstands (1 pre-drilled)
PATCH BOSS
Size mm Code A B Colour Qty

A
32x82 SWS332 95 18 G 20 A

A 40x82 SWS340 95 23 G 20 CONDENSATION TRAP A


50x82 SWS350 95 27 G 20 A Size mm Code A B C Colour Qty
B
B 110 SCT4 115 82 22 G 6
B
B B C
With 21.5/22mm overflow connection
8-WAY COLLAR BOSS For ventilation pipework only

F
Size mm Code A B C D E F G Colour Qty
C
110 SCB41 195 157 140 195 61 204 70 G 1 ACCESS CAPS D
Size mm Code A B Colour Qty
G Solvent socket/spigot
C A 82 SE30 114 35 BG 30
E A
B 110 SE40 150 37 BG 30
A
A
B 160 SE62 195 40 G 15
D B
With pressure plug
B
F
C ACCESS PIPES
Size mm Code A B C D E F G Colour Qty
D Size mm Code A B C D Colour Qty
G 110 SCBS41 184 146 140 164 61 204 70 G 1
D 110 SFS41 150 75 56 154 W B G 4
E A
Solvent socket C A
B Double solvent sockets. 3 boss upstands
B
C
A
D

B
A
22 | MARLEY PVC Soil & Waste To BS 4514 and / or BS EN 1329 'B' as appropriate CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 23
B
A

Solvent soil – PVCu Accessories

B
B A
A

ACCESS PIPES CLIPS


D Size mm Code A B C D Colour Qty B Socket clip
C A
160 SF611 287 144 138 223 G 2 B B
A Size mm Code A B Colour Qty
A
Double solvent sockets 110 SC41 152 101 BG 50
A
160 SC61 240 121 G 50
B PVC coated mild steel, includes 6x20mm nut and bolt

Barrel clip collar


REAR ACCESS BEND
Size mm Code Colour Qty
Size mm Code Angle A B C Colour Qty
A
1000 SC621 G 25
110 SBS420 87½° 131 128 54 BG 4
Converts socket clip to pipe clip (3x110mm or 2x160mm)
Double solvent socket
B Pipe clip
C
B
A
Size mm Code A B Colour Qty
B
B A 82 SC35 125 93 BG 20
BOSS CONNECTORS C
B
A 110 SC45 150 101 WBG 50
A
Size mm Code A B Colour Qty Closed pipe clip
B B
32 SA415 35 20 G 50 A
A A
B Pipe clip
A
40 SA425 30 25 BG 50
Size mm Code A B Colour Qty
B 50 SA435 58 28 G 50 B
AB
82 SC35S 117 70 BG 20
Solvent weld with solvent weld joint
For use with drive-in spike or backplate

A
A Size mm Code Angle A B C D Colour Qty B Extension backplate
C
A B
40 KBK25 90° 48 48 23 23 WB 20 Code A B Colour Qty
A
50 KBK35 90° 59 A 50 20 28 W 10 C A RT200 104 45 W B G BR 50
B
D
 Knuckle bend/boss adaptor, which can solvent weld over a boss upstand A PVCu
B
B For use with RC251/2, RCE2 and RC32 pipe clips
B
Size mm Code A B Colour Qty
B B
Drive-in spike
32 SA411 43 21 WBG 50 Code A B C Colour Qty
A

A 40 SA421 43 21 WBG 40 C
B
A C RSS1£ 115 58 154 G 50
50 SA420 66 45 BG 40
A A Galvanised mild steel
A Solvent weld with push-fit seal AC
B C
A A Backplate
CONCENTRIC REDUCERS B
Code A B Colour Qty
B B
B
Size mm Code A B C Colour Qty B RCB300 48 31 W B G BR 100
B B A
B A A
A 110-50 SE41 105 135 BG 18 C For use with SC35S
C
A
Spigot to boss upstand B
B

B Extension Bracket
A A Code A B Colour Qty
A C
A B
110 RT250 243 114 BG 20
ECCENTRIC REDUCERS
B
C A
B A Size mm Code A B Colour Qty A=111 (HOLE-SAW SIZE)

C B=35

BD A B
A Cover plate
A
C 82-50 SRM30 66 35 BG 90 A
B Code A B Colour Qty
B A Spigot/Socket
A 110 RT2501 111 35 BG 1
A B
For use with RT250
Size mm Code A B C Colour Qty B

B A
C A=137
Pipe clip
C B A 110-50 SRM402 48 25 19 BG 10 B=111

A A
B Solvent socket to boss upstand Code A B Colour Qty
B
A
110 RPC1 137 111 BG 20
C BB For use with RT250
Size mm Code A B C Colour Qty
B A
110-82 SRS304 82 110 52 G 6 A=141
B=119 Socket clip
76 A
A
C B 160-110 SRS604 168 68 20 G 6 A
Code A B Colour Qty
D
B
C
Spigot/Socket
110 RSC1 141 119 BG 1
B
A B D B For use with RT250
A B A D
C C A
B A C To BS 4514 and/or BS EN 1329 'B' as appropriate To BS 4514 and/or BS EN 1329 'B' as appropriate. Accessories are suitable for both push-fit and solvent soil systems
24 | MARLEY PVC Soil & Waste CAD drawing available to download from marleypd.co.uk CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 25

110mm 500mm
B A
A
A
A

A
A

Product range
Accessories WC connectors
B
B

C B A
A
A B
B
C

A B
B
A
A
A

C B
B A

DURGO AIR ADMITTANCE VALVES


C
C B
A
STRAIGHT CONNECTORS C
B
B A
Size mm Code A B C Colour Qty B Size mm Code Angle A B C Colour Qty
B A B
50 SVD2* 98 82 28 W 32 A 110 SG40 14° 63 50 134 W 4
B 82 SVD3* 108 118 40 G 18 Spigot
C
C
C
110 SVD4 124 138 50 G 18
A B A
A AC
B
A Durgo valve including polystyrene insulating hood. B
D
C *Can be fitted below flood level. It is recommended this isA fitted in a push-fit socket. A

B A C BBA certified for use up to 10 storeys.


B
B B C
Size mm Code Angle A B C D Colour Qty
A DB
B
B B
110mm 500mm C 110 SGS41W* 14° 139 134 53 80 W 20
B C
A B D C
A A
A
D 
B Solvent socket. Pan socket to be trimmed to suit WC spigot length
C C C
A C

VENT TERMINALS C B
A
C B A B AA A
110mm
110mm 500mm
500mm A C
Roof cowl/vent terminalC 1
A
C 2 BENT CONNECTORS
B Size mm Code A 3B C Colour Qty A
A
B
C
C B
B
750mm Size mm Code Angle A B C Colour Qty
110 SVC111 200 98 70 WBG 10 B A

A A
A
2
2
3
A 110 ST40 90° 106 125 51 W 4
A 750mm
3
750mm B
C
B Solvent socket
C Vent terminal B
B
B Size mm Code A B C Colour Qty C
C
C B A B C
A A D
B
B 82 SV321 90 30 75 A BG 30 CC
A C
A C
A
110 SV42 117 34 95 WBG 60 B
B D
A
A
A A
A C B
C C 110mm
A
Vent terminalA
A B
500mm B A
B
B C
B Size mm Code Angle A B C Colour Qty
Size mm Code A B C Colour Qty C D B
C
160 SV62 £
160 71 25 G 20 A
110 ST41W 90° 106 240 210 W 4
A C B Long spigot
B B A
B
1 B
C
Vent terminal 2 B D
A A
A Size mm Code A 3B Colour Qty
750mm
B
50 RV225 55 18 WBG 30 B
C
B
C
B C
B C
C A
B
A B D Size mm Code Angle A B C D Colour Qty
A C
A C
STS41W*
WEATHERING COLLAR
C
D
D 110 85° 104 156 53 80 W 4
C
Size mm Code A B C Colour Qty 
A B D Solvent socket. Pan socket to be trimmed to suit WC spigot length
B C
110mm 500mm 82 SV31* 51 94 25 B 100 B
A B
C 110 SV43A 57B 130 25 WBG 35 D
C
B A
PVCu for solvent joint to pipe *Available in black rubber only. A
C B A A
B
A C
1
2 A B
A
3 D B
750mm B
Size mm Code Angle A B C D Colour Qty
B A
C
WEATHERING SLATES 110 SBS40W 90° 114 240 48 110 W 4
Size mm Code A B Colour Qty B
Long spigot/ solvent socket
C B
C
B A
400 SAS40 400 400 G 5 A
C
A A C
Flat. Manufactured from aluminium and rubber A
C
D
Size mm Code A B Colour Qty D

A 450 SAS45 450 450 G 5 WC SEAL AND CAP D D


C A B
B 610 SAS61 610 610 G 5 83 – 114mm outlet
B
B Size mm Code A B Colour Qty
Inclined. Manufactured from aluminium and rubber
B
A
SA323W 141 24 70
A
A
For use with SGS41 and STS41
A

C B
To BS 4514 and/or BS EN 1329 'B' as appropriate. Accessories are suitable for both push-fit and solvent soil systems
26 | MARLEY PVC Soil & Waste CAD drawing available to download from marleypd.co.uk *When fitted to short WC pan spigots, pan Dsocket should be trimmed to suit before SA323W (not supplied) is fitted. MARLEY PVC Soil & Waste | 27
Universal push-fit WC connectors WC manifold system

A
STRAIGHT CONNECTORS BRANCH A
Size mm Code Angle A B C D Colour Qty Size mm Code A B C Colour Qty
B AA A
D
B
100 SWC11 132 110 81 46 W 25 C 110x90 SM41W 214 50 116 W 10
D C Solvent sockets
B C
CB
A D C
B
B
A C
B
B
B

A C C

D ADJUSTABLE WC BEND
B A
D A Size mm Code Angle A B C D Colour Qty
B
Size mm Code Angle A B C D Colour Qty
AA 90 SM42W* 50-90° 108 134 75 60 W 15
A D AA
B 100 SWCB14 14° 132 61 81 46 W 20 A 50mm vent boss upstand
A C B
Pan socket to be trimmed to suit WC spigot length
C BB C
A BB
C
C
C C
C D
B D
D D
D D
C
D

A
18
D ADJUSTABLE SPIGOT BEND
C
A AA A Size mm Code Angle A B Colour Qty
18 A
C A
A
A 90 SM43W 50-90° 119 75 W 15
18 B Size mm Code Angle A B C D Colour Qty
C 50mm vent boss upstand
B 100 SWC22 22° 132 115 81 46 W 25 Pan socket to be trimmed to suit WC spigot length
B
B B
B
B
B
B

WC CONNECTOR C
A
A
LONG BENT CONNECTOR A A Size mm Code A B C D Colour Qty

Size mm Code Angle A B C Colour Qty B


A 90 SM44W* 117 134 46 80 W 30
B
D 100 SWCB90D B 90° 132 235 81 W 10 B C
Pan socket to be trimmed to suit WC spigot length
B D
C

B
D
B D* C C
D*
B D* C
A D C C
E C A D*
C
A C
B

E D*
C
A
A
D

E B
A C EXTENSION PIPE B
B
B
Size mm Code A B Colour Qty
E

B
A

B
B A
A B 90 SM45W 96 46 W 50
B
A 300mm
A For use with SM43 only
EXTENSION PIECE
A
A

Size mm Code A B C D Colour Qty A


C
A

B 100 SWCE33 81 300 116 226 W 12


D
B
D
A

WC SEAL AND CAP


B

C
C A
B

83-114mm outlet
B Size mm Code A B Colour Qty
B

90 SA323W 141 24 W 70
A
C

A For use with SM42 and SM44


C
C
C
C
C

28 | MARLEY PVC Soil & Waste Push-fit WC connectors are manufactured to BS 5627. CAD drawing available to download from marleypd.co.uk *When fitted to short WC pan spigots, pan socket should be trimmed to suit before SA323W (not supplied) is fitted. MARLEY PVC Soil & Waste | 29
B
D
B
D
Product range

PVCu floor outlets Ancillary items


TRAPPED FLOOR GULLIES SOLVENT CEMENT
Size mm Code A B C D Colour Qty Tub
50 SFG42AS 117 164 145 116 G 8 Size Code Qty
A
Solvent outlet. 90mm adjustable water seal 250ml KS10 Tub 20
110

500ml KS20 Tin 20


B Size mm Code A B C D Colour Qty
To BS EN 14680
D
82 SFG43AS 117 164 175 100 G 8
Solvent outlet. 75mm adjustable water seal SILICONE LUBRICANT
C
Tube with sponge applicator
Size Code Qty

50g SZ50 10
STAINLESS STEEL TILE GRATE AND COVER
Code A B C Colour Qty

C 150x150 SGG4 150 150 7 NU 40


Bottle
Grade 304 stainless steel
Size Code Qty
A B
100g SZ100 50

Aerosol

Pipe support systems Size

400ml
Code

SZ400
Qty

12
TWO PIECE PIPE BRACKET
Size mm Code Colour Qty
Tub
110 JB42* NU 50
Size Code Qty
160 JB62* NU 50
500g SZ500 24
Water Research Centre Approved

Soil &BASE
ventPLATE
JB32 SPARE RING SEALS
Size mm Code Colour Qty
‘T’ ring
110 JBP42* Double support NU 1 Size mm Code Qty
160 JBP62* Double support NU 50
82 SR82T 5
JDP1* Single support NU 50
Double Single 110 SR110T 5
160 SR160T 5
CHANNEL STRIP
Pipe
Pipe support- D/supp support-
base plate single plate Size mm Code Colour Qty
To BS EN 681/1

2000 JCS2 *
Strip NU 50
JCA1* Angle NU 10

BARREL CLIP COLLAR


Pipe support- channel strip Channel angle
Pipe support- Code Colour Qty

SC621* NU 25
1m PVC strip when cut to length. Converts pipe bracket to pipe size
(3x110mm or 2x160mm)

NUTS AND BOLTS


Size mm Code Colour Qty

20x6 RNB11* NU 1

CAD drawing available to download from marleypd.co.uk


Pipe support-
30 | MARLEY Nut/bolt
PVC Soil & Waste *For internal use only – Mild steel, zinc plated MARLEY PVC Soil & Waste | 31
Design

Bends at the base of stacks


Sanitary pipework design Bends at the base of vertical stacks should be of long radius and have a
All sanitary pipework systems should be designed to satisfy the following regulations and standards where applicable. minimum centre line radius of 200mm on a 110mm nominal size stack.
Two 45° radius bends may also be used as an alternative to provide the
●● The Building Regulations 2010: Approved Document H, Section 1.
change of direction and connection to the building drain. The same
●● The Building Standards Technical Handbook (Scotland) 2010: Part M. design principle should also be adopted where offsets occur in stacks min 200mm
radius
of one or more storey height.
●● The Building Regulations (Northern Ireland) 2000, Technical Handbook N.
Where pipework is suspended in a ceiling void or car park, it is
●● BS EN 12056: 2000, Parts 1 to 5. recommended that two 45° solvent weld bends are used with a short
Regular consultation is essential between Architects and Plumbing Engineers throughout the building design stage as the careful arrangement of piece of pipe between to ensure the radius exceeds that required.
kitchen and bathroom appliances will simplify the final sanitary pipework layout. This will help to ensure that an efficient sanitary pipework system
is installed at minimum cost. long radius bend
UBL488
The design information provided in this catalogue is endorsed in the above publications and while every effort has been made to ensure accuracy,
no responsibility can be accepted for errors or omissions. For detailed guidance please consult the relevant documents referred to above.

Methods of jointing
SWS415/41
82, 110 and 160mm PVCu pipes and fittings are available in both solvent and push-fit jointing boss pipe
methods. Solvent soil is widely used on smaller diameter waste and overflow pipework, although Branches at the base of stacks
expansion and copper adaptor couplings include a push-fit joint to allow for thermal movement. solvent
weld joint
For single dwellings up to three storeys high, the distance between the
As polypropylene cannot be solvent welded, the push-fit method of jointing is used throughout centre line of the lowest branch connection and the invert of the drain
the system. should be at least 450mm. For multi-storey systems up to five storeys
high, the minimum distance should be 740mm and for systems higher
push-fit than five floors no connections are permissible at ground floor level.
joint Where this occurs a separate stub stack should be provided to serve UBL488 or
Thermal movement the ground floor or individual appliances should have their own L
2 – UB455 bends
separate connection to the building drain.
The coefficient of linear expansion for PVCu is 0.06mm/m/°C. As a result a 3m length of
pipe will increase in length by approximately 3.6mm when subjected to a 20°C temperature
variation. Therefore, it is important to ensure that any movement is controlled and push-fit
joints are installed to accommodate any expansion that may occur due to increases in ambient
temperature or hot water discharges.
L = 450mm up to three storeys high
L = 740mm up to five storeys high
L = one storey height, over five storeys

Sizing of soil stacks Material and manufacture Pipe dimensions and weights
It is recommended that the guidance given within BS EN 12056, part 2 be adopted when sizing soil Marley Plumbing & Drainage pipes and fittings for sanitary pipework Mean Outside
Pipe BS Nominal Wall
stacks. Marley Technical Services Department offer design and installation advice, including the sizing systems are manufactured from different plastics materials including Diameter (mm) Weight
Material Size Thickness
of soil stacks, for customers who use or specify Marley Plumbing & Drainage products. PVCu, PVC-c, ABS and PP. kg/metre
Standard (mm/inch) Min Max (mm) Min
The table right details the important dimensions and weights of each
Soil stack capacity Soil PVCu
of the systems together with the relevant British and European Standards
The capacity of a soil stack can be increased by the installation of a secondary ventilated stack. The Pipe: BS 4514 82 82.4 82.0 3.0 1.30
we manufacture to. All pipes are manufactured using a continuous
following information is taken from tables 11 & 12 of BS EN 12056-2: 2000 which illustrates this increase. 110 110.0 110.3 3.20 1.70
extrusion process and fittings are produced by high-pressure injection Pipe: BS EN 1329
160 160.0 160.4 3.20 2.50
moulding.
Waste PVC-c
36/1¼ 36.15 36.5 1.80 0.33
Primary ventilated stack Secondary ventilated stack Chemical and temperature resistance Fittings: BS 5255
40/1½ 42.75 43.1 1.90 0.41
Stack size Maximum capacity (l/s) Stack size Secondary vent Maximum capacity (l/s) Most plastics used for sanitary pipework are highly resistant to those Pipe: BS EN 1566
50/2 55.75 56.1 2.00 0.57
chemicals normally found in domestic waste water and sewerage systems.
(mm) Swept entries (mm) (mm) Swept entries For applications where chemical discharges are likely to occur, HDPE soil Waste ABS

82 2.6 82 50 3.4 range may be more suitable. 32/1¼ 36.15 36.5 1.80 0.20
Pipe and fittings:
110 5.2 110 50 7.3 43/1½ 42.75 43.1 1.90 0.26
Generally the maximum working temperature of Marley PVCu and PVC-c BS EN 1455
50/2 55.75 56.1 2.00 0.35
160 12.4 160 80 18.3 when subjected to continuous flow is 70°C and 75°C respectively. Higher
intermittent discharges of up to 95°C may be accommodated by PVCu Waste Polypropylene
provided the period of discharge does not exceed one minute duration. 32/1¼ 34.45 34.8 1.80 0.21
Pipe: BS EN 1451
40/1½ 40.85 41.2 1.90 0.26
Alternatively, reference can be made to ISO publications TR10358
& TR7620 which provide comprehensive information on chemical Overflow PVCu
Secondary ventilated stack and temperature resistance of plastics and rubber materials. 21.5/¾ 21.55 21.70 1.10 0.11

32 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 33
Design

Offsets in stacks Stub stacks 8-way collar boss Branch pipe gradients
Offsets in the wet portion of a discharge stack An unventilated stub stack terminated with an The gradient of a branch pipe should be
should be avoided wherever possible but access fitting may be used to connect a group uniform and adequate to drain the pipe and
where they have to be fitted a large radius or of ground floor appliances to the building drain appliance efficiently. A minimum gradient of
SY401 Equal Branch
two 45° bends should be used to create each provided the vertical drop to the invert level 18mm/metre should be adopted for 32, 40 and
change of direction. Offsets in lightly loaded of the drain does not exceed 1.5m from a WC 50mm nominal size pipes but larger diameter
stacks up to three storeys high do not require and 2.5m from a waste appliance. Where one 82, 110 and 160mm branch runs may be laid
Top & side waste
offset venting but on multi-storey buildings this or more stub stacks are connected to the same connections flatter at 9mm/metre fall where the discharge
may be necessary depending on the loading drain, the head of the run should be ventilated for maximum flow rate exceeds 2.5 litres/second.
of the stack and the numbers of floors above to atmosphere or air admittance valves fitted flexibility, even
in tight spaces.
the offset. The principles previously described to each stub stack arrangement. Design prevents Branch pipe lengths
for bends and branches at the base of a stack any danger of
should also be applied. SE40 cross-flow. The following information is taken from Table 6
access cap of BS EN 12056: 2: 2000 and provides general
SWS415/41 Hole cutter locator
guidance on the recommended lengths
Stub waste boss pipe
Factory fitted, air of unventilated branch pipes for a variety
This technique is often used to connect isolated tested joint ensuring 61mm of sanitary appliances.
long term integrity.
ground floor waste appliances such as basins,
No need for pipe to be cut
baths, shower trays and sinks to eliminate exposed on site, saving installation
pipework or low level ducting. The 110mm time. Comes complete
unventilated PVCu drain is terminated at finished with pre-chamfered spigot
tail for easy jointing.
floor level with a reducer and boss adaptor to suit SY401
the size of waste from the appliance. Branch
SCBL41 – 350mm
Long spigot tail,
accommodating virtually Min.trap seal Max. length
Appliances Dia (mm) Pipe gradient (%) Max. bends (No.) Max. drop H (m)
all floor thicknesses. depth (mm) of pipe (m)
SA411/421/420
32mm/40mm
or 50mm Rigid fire collar Washbasin or bidet 32 75 1.7 2.2 0 0
2.5m
Boss connector max or fire pipe wrap. Washbasin or bidet 40 75 3.0 1.8 to 4.4 2 0
Bath or shower 40 50 No limit 1.8 to 9.0 No limit 1.5
SC41 clip fitted Bowl urinal 40 75 3.0 1.8 to 9.0 No limit 1.5
around socket. Trough urinal 50 75 3.0 1.8 to 9.0 No limit 1.5
1.5m
SRM402 Long radius
max
Eccentric reducer bend UBL488 Kitchen sink 40 75 No limit 1.8 to 9.0 No limit 1.5
Dishwasher or washing
40 75 3.0 1.8 to 4.4 No limit 1.5
machine
UB411
Bend WC 110 50 No limit 1.8 min No limit 1.5

The maximum lengths given above may be increased where the branch pipe is ventilated or an air admittance valve is used. For further details refer
to the above standard.

Prevention of cross-flow To prevent cross-flow from a large diameter The Marley Collar Boss was specifically designed to overcome installation problems imposed
branch to a smaller waste connection, the latter by the 200mm restricted zone and to allow multiple low level bath or shower waste pipes to be
Where small diameter branch waste pipes
should be made to the stack at or above the connected to the stack above floor level. Cross-flow is prevented as the circular annular chamber
connect to a discharge stack they must be
centre line of the larger protects the small diameter waste connections from the WC discharge allowing waste water to
arranged to eliminate the risk of cross-flow from
branch, at right angles or flow freely and merge below the critical zone.
one branch to the other. A branch creates a
at least 200mm below the
no entry zone for opposing waste connections, Different combinations of 110mm branches can be used with the collar boss to accommodate
restricted zone. Entry is
which varies depending on the stack diameter. various WC positions which may be up to 3 metres from the vertical stack. SY401
permissible on the boundary
No connections should be made within the Branch
SWS40 centre line directly opposite
restricted zone although entry is permissible
Boss pipe or at right angles.
on the centre line of the boundary directly
opposite or at right angles.

H
Stack size Height of zone 'H'
200mm
(mm) (mm)
SA421 SCB41
Boss adaptor SY405 Collar boss
82 90 branch
SA421
110 110 Boss connector
160 250

‘H’ = 200mm irrespective of stack diameter

34 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 35
Design

Combined branch waste Waste traps WC manifold system


A combined branch waste is often used to Generally appliances such as sinks, baths and The Multikwik anti-vac bottle trap, B032V Developed for use in sanitary pipework systems the minimum distance between the end of the To accommodate different dimensions
connect a bath and/or shower and basin to the showers do not suffer from self-syphonage / B040V, was specially developed to prevent in schools, hospitals, public and commercial WC spigot and the face of the wall is 150mm. between the WC spigot and horizontal float,
discharge stack as this allows waste pipework as the trap seal is replenished at the end self-syphonage from basins, which can occur buildings, the manifold system allows ranges To facilitate varying angles and gradients the the adjustable spigot bend SM43W may be
to be neatly concealed in a low level duct. of the discharge due to the flat bottom particularly where the waste pipe drops of toilets to be connected to a horizontal float 110 x 90mm manifold branch has a radial trimmed by up to 35mm or the extension pipe
design of the appliance. Tubular traps are vertically from the appliance before falling above floor level and eliminate the need for socket to match both options of adjustable SM45W can be used with the pan connector
Where this technique is adopted a 45° entry tee
recommended for such appliances as they at an even gradient to the discharge stack. specially fabricated fittings. WC bend. When the selected bend is cut to SM44W and SA323W cap & seal.
must be used to ensure the basin discharge is
ensure unrestricted discharge and reduce the the appropriate line and solvent welded into
swept in the direction of flow towards the stack. The trap also eliminates the need for a The components are suitable for installation in The WC socket on both the SM42W and
risk of blockage and prevent the accumulation the socket on the manifold branch a uniform
The minimum distance between the bath or secondary vent pipe where basins are located a duct, or for fitting on the surface of the wall SM44W must be trimmed to suit the length
of sediment. fall is obtained between each toilet on the
shower and basin connection should not be less further than the recommended 3m maximum directly behind the pan. Where the manifold of pan spigot before the SA323W is fitted.
horizontal float.
than 500mm and it is recommended that an ●● C
 ompression jointed polypropylene traps from the stack. Non-mechanical, the trap is fitted directly behind the range of toilets,
For installation details see page 45.
anti-syphon bottle trap is fitted to the basin or can be taken apart to remove a blockage operates as air is drawn in through a by-pass
a vent provided to protect the appliance from or gain access to the waste system tube to eliminate any syphonic action and
self-syphonage. ensure the trap seal is maintained.
●● R ange includes P-traps, S-traps, bottle
traps, bath & shower traps and different It is recommended its use is restricted
It is recommended that the distance of the SM42W
configurations for washing machines, to ground floor baths and showers that & SA323W
combined waste does not exceed 3 metres,
dishwashers, 1½ or 2 bowl sinks discharge directly to an external trapped
however, experience has shown that longer runs
gully. It should not be fitted to a bath or
using 40 or 50mm pipework has proved successful ●● White with multiple seal depths
shower where the waste pipe is connected
provided adequate fall can be obtained to ensure centre line of WC outlet SM41W
●● Sizes: 32, 40 and 50mm to a soil stack.
self-cleansing velocity is maintained from finished floor level
B032V
Anti-vac
bottle trap

190mm
Now available from

P6040 low
level trap 110mm float at
KT21W entry tee
SWS41 9mm/metre fall SY401/SY405
KBA22W branch
Bath/ boss pipe
45º bend
Shower

40mm SM42W
500mm min
adjustable bend

30
35
B
Manifold branch SM41W with SM42W 215mm minimum Manifold branch SM41W with SM43W
duct width

Cut line 50° 55° 60° 65° 70° 75° 80° 85° 90° Adjustable wall fixing Cut line SA323W 50° 55° 60° 65° 70° 75° 80° 85° 90°
cap & seal

A – projection (mm) 93 93 92 91 90 87 84 80 75 Flush plate


A – projection (mm) 180 180 179 178 177 174 171 167 162
SM41W
B – drop (mm) 69 77 85 93 101 109 116 123 130 B – drop (mm) 69 77 85 93 manifold
101 109 116 123branch
130
W.C. Cistern

Front panel

W.C. Frame
W.C. seal & cap
SA323W
A
A
Flush pipe SA323W cap & seal
A
SM42W
adjustable SM43W
SM43W
WC bend SM42W
SM42W adjustable spigot bend
adjustable
SM43W WC
adjustable
adjustablebend
WC bend WC bend
spigot bend
SM41W
Manifold branch

30
35
SM41W
30

JB42 two peice pipe


35

manifold branch B
bracket with SC621 B
barrel clip collar 110mm float
SA323W
SA323W SM41W
SA323W
SA323W capcap & seal
& seal SM44W
cap
cap&&seal
seal manifold
110 x 90mm branch SM41W Adjustable bend SM42W with socket SM41W pan connector branch
trimmed to suit 50mm pan spigot manifold SM44W
JB42 two peice pipe bracket Adjustable bend SM42W with socket SM41W
SM41W
branch pan connector
manifold branch with SC621 barrel clip collar trimmed to suit 50mm pan spigot manifold branch

36 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 37
Design

Durgo air admittance valve Fire protection


The Durgo valve is designed to reduce the When installed the valve will remain closed For up to and including four dwellings, 1, 2, or The Building Regulations 1991 (as amended) Tests carried out at FIRTO on a variety of typical Various other arrangements were also tested and
number of ventilating pipes and subsequent roof unless the system is subject to negative 3 storeys in height, additional drain venting is require that a building shall be sub-divided into sanitary pipework arrangements proved that achieved a minimum of 2 hours integrity.
penetrations in domestic, commercial and public pressure whereby the diaphragm will lift and not required. Where a drain serves more than compartments where necessary to inhibit the it was possible to achieve up to 1½ hour fire
The construction illustrated below achieved a
buildings. Suitable for use in sanitary pipework allow air to be drawn in to eliminate syphonic four such dwellings equipped with the valve, spread of fire. Plastics pipework is permitted rating through a compartment floor without
1½ hour fire resistance rating without the need
systems up to ten storeys high, the valve must action. Positive pressure ensures the valve the drain should be vented according to the to penetrate separating walls, compartment a fire collar or pipe wrap where the stack
for a fire resistance enclosure. The enclosure is
be fitted in a vertical position above the flood closes and prevents foul air escaping from the following rules: walls and floors provided the appropriate was terminated by an air admittance valve.
necessary to achieve a 2 hour rating.
level of the highest appliance connecting to system. Each valve is supplied boxed with a measures are taken to prevent the spread of
5 to 10 such dwelling – conventional ventilation
the stack. Valves should be installed within polystyrene insulation cover that should remain fire in accordance with Part B of the Approved
to be provided at the head of the system.
the building in a ventilated duct or roof space in position after installation, as this will protect Document (2010).
where there is no risk of freezing and must be the valve against freezing, particularly when 11 to 20 such dwellings – conventional
To comply with this, pipes must be enclosed
accessible for inspection and testing. installed in a roof space. ventilation to be provided at the mid-point SVD4 Durgo air
within a fire resistant enclosure which extends admittance valve
and at the head of the system.
The 50, 82 and 110mm size valves have been To ventilate the underground drainage system from floor to ceiling within each storey. The
assessed by the British Board of Agrément and and to minimise the effects of back pressure For multi-storey domestic dwellings (other than enclosure must have a class ‘O’ internal surface SE400 pipe
those referred to previously) and non-domestic socket
awarded Certificate No 06/4325 which permits should a blockage occur, the branch or main and have each side formed by a separating
their use in accordance with the Building drain serving a stack or stacks fitted with Durgo buildings, conventional drain venting should wall, external wall or by casing. Any casing must
Regulations. A copy of the full certificate valves may require conventional venting at be provided if more than one such building, have a minimum ½ hour fire resistance and
is available and provides comprehensive a point upstream of the stack connection. each equipped with the valves, is connected penetrations of the duct must be limited to
information on their use and installation. to a common drain which itself is not vented 160mm vertical and 110mm horizontal. SGS41/SA323W
by means of a ventilating stack or a discharge WC pan connector
Where longer periods of fire resistance are
stack not fitted with a valve. SW40
required, fire collars or pipe wraps can be fitted. boss pipe
Stacks should not be fitted with valves when
11 to 20 dwellings SVP at head and mid point
the connecting drain is subject to periodic
5 to 10 dwellings SVP at head surcharging or is fitted with an intercepting
Up to 4 dwellings no SVP required trap. An open vent must be provided and
this also applies to stacks that discharge to
SVP Durgo SVP Durgo Durgo Durgo a cesspool or septic tank. SY401
branch

20th 11th 10th 5th 4th 1st

Indicative row of 20 dwellings 3 storeys high (maximum) fitted with Durgo valves Floor and enclosure fire stopped at all openings using
materials meeting building regulation requirements

KAP2
KXT21 WHB

Technical
SVD4-110mm 2No KR210
BASIN FLOOD LEVEL B032R
B1 rated valve
fitted above
SE400 Coupling flood level
or pipe socket of basin WHB

advisory
B032R KT2
SC45 Pipe clip SVD4
KAP2
S421150 WC
B032V 110mm PVCu pipe 40
mm S411195

service
Anti syphon bottle trap SBS40
S201156
KR210 reducer SVD3-82mm MKS2
A1 rated valve S411195
fitted below GW059
flood level KBA22 m
0m
SWCB90 SRM304 110x82mm of basin KB22 11
90° connector Level invert reducer
Marley Plumbing & Drainage provide technical
40mm dia
support to all those involved with the specification
BATH/SHOWER SYS415 S241103
87.5° Branch and installation of their products. This enables a WC
4No S411195
SBS40
P1940 KBA22 specialist team to give detailed advice on the best mm
Low level 'p' trap 45º bend MKS2 110
40mm dia way of utilising the extensive range of products
and systems manufactured by the company for
UFC1
F.F.L. building services.
KT21
45º tee
2no 45° Bend SA421 SCBL41 Technical Hotline: 01622 852695 2No S121145
KBA22/KB22 Boss connector Collar boss 3No S411195

38 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 39
Installation data

Jointing techniques
The ring seal has been successfully employed as Solvent soil stack installation Push-fit soil stack installation
the principal method of jointing large diameter
The addition of the SE409 ring seal adaptor allows for thermal
PVCu pipes and fittings since their introduction
movement required in a solvent soil installation
over thirty years ago. This particular technique
has proved extremely reliable as the joint can
accommodate thermal movement that will
occur as a result of temperature variations. An SES401 SC41
expansion gap of between 5-10mm should be Double solvent coupling Socket/support clip
SC41 Anchor point
allowed within each ring seal socket as each full SES401
Socket/support clip SC41
length of pipe is installed and fixed using socket Double point
Anchor solvent coupling Socket/support clip
SC41 Anchor point
and barrel pipe clips. Socket/support clip
Anchor point
Solvent weld jointing is also widely used and
many components in the range are available Ring seal joint
with this facility to provide an effective
alternative. By selecting these fittings a solvent
Solvent weld joint
weld system can be installed, however, ring
seal joints must be incorporated to control
thermal movement.
While the most popular method of jointing

MAX 2000mm

MAX 2000mm
larger size PVCu pipes and fittings is by ring
seal, with small diameter waste pipework the

MAX 2000mm

MAX 2000mm
principal choice is usually solvent weld. Where
this technique is used expansion couplings
must be introduced where pipe lengths exceed
1.8 metres or between fixed points. The same
40mm waste pipe Expansion coupling KEC2
principle should also be adopted when the
polypropylene push-fit waste system is installed.
It should be noted that polypropylene cannot SFS41 SFS41
Access pipe Access pipe
be solvent welded and together with the ABS
waste system must not be fitted externally SFS41 SFS41
Access pipe Access pipe
unless painted to protect it from ultra-violet pipe clips
degradation.
For installation using solvent cement please see 5 to 10mm 5 to 10mm
Expansion gap Expansion gap
marleypd.co.uk SC45 SC45
Pipe/barrel clip 5 to 10mm Pipe/barrel clip
5 to 10mm
Guide bracket Expansion gap Guide bracket
Expansion gap SC45 SC45
SE409
Pipe/barrel clip Pipe/barrel clip
Ring
Guideseal adaptor
bracket Guide bracket

Pipe support Connection


SE409
SYS405
Connection
SY401
Ring sealbranch
110mm adaptor 110mm branch
Experience has proved that an efficient and from W.C from W.C

reliable PVCu sanitary pipework system depends SCB41


SYS405 SC41SY401
Connection Connection
Connection from Collar boss branch
110mm Connection from Collar boss branch
110mm
considerably on the attention that is placed from W.C
bath/shower
from W.C
bath/shower
on the correct provision of pipe support SCB41 SC41
Connection from Collar boss Connection from Collar boss
brackets. This is particularly important in multi- bath/shower bath/shower
storey buildings where care must be taken to
ensure clips are positioned to control thermal
movement at each floor level.
Plastic coated metal socket clips are designed
to fit ring seal sockets and act as anchor
brackets. These used in conjunction with PVCu
intermediate pipe clips, control expansion and Barrel pipe clip SC45 Socket pipe clip SC41
Pipe material BS Nominal pipe size Horizontal support (m) Vertical support (m)
contraction and maintain the vertical alignment
of the stack.
PVCu 21.5 0.50 1.20
Two piece socket clips SC41/61 may be adapted pp 32 0.50 1.20
to suit the appropriate pipe size by using a
40 0.50 1.20
section of barrel clip collar SC621 to provide
PVCc 32 0.50 1.20
the necessary spacer sleeve. The table opposite
indicates the maximum recommended support ABS 40 0.50 1.20
centres of different size plastic pipe systems. 50 0.60 1.20
PVCu 82 1.00 2.00
110 1.00 2.00
160 1.20 2.00

40 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 41
Installation data

Marley pipe support system Boss branches


The Marley pipe support range was developed to meet the specific requirements of PVCu The Marley range of boss branches are 32, 40 or SA411/421/420
suspended sanitary pipework and drainage systems. Manufactured in zinc electro plated mild designed to allow multiple waste pipe 50mm pipe boss connector
steel for internal use, the versatile range of components can be assembled to provide a robust, connections to be made to the discharge
lightweight system suitable for most applications. The system also provides suitable control of stack from different directions. Four different
expansion and contraction. side entry combinations are possible together
with a rear if required. Staggered waste
The arrangements of brackets and channel supports have been extensively tested and the assembly
pipe connections, directly opposite are not
techniques used have been successfully employed on many domestic and commercial installations.
permitted as cross-flow could occur.
Single support
Recommended for waste or larger diameter pipework fixed within 500mm of the floor soffit. see table
Compatibility
Double support Boss pipes, boss connectors and strap-on
angle brace
bosses fitted with multi-fit ‘T’ ring seals are
Developed for use with larger diameter pipework fixed within 1.0m of the floor soffit.
suitable for use with PVCc or ABS waste systems
Pipe brackets 500mm max. to BS EN 1566 or BS EN 1455-1, polypropylene
or 600mm with SY405 SA411/421/420 SY405 KBK25 or KBK35
to BS EN 1451-1 and metric size copper to branch boss connector branch knuckle bend
The 110mm two piece pipe brackets are designed to fit round the ring seal socket ofside
a pipe
bracingor
110mm pipe BS EN 16090.
fitting. Where intermediate support brackets are located, the SC621 PVC barrel clip collar is used
as a spacer sleeve between the pipe and bracket. anchor bracket Un-perforated boss upstands on boss pipes,
branches and reducers may be drilled to accept
Angle and side bracing 32, 40 and 50mm boss connectors SA411, SA411/421/420 SA411/421/420
intermediate bracket
Angle braces should be provided at 6m centres to prevent lineal and thermal movement. Side SA421 and SA420 using a 51mm diameter hole boss connector boss connector
bracing may also be necessary on long runs where there are no side connections to eliminate saw. Knuckle bends KBK25 and KBK35 may also
lateral movement. be used as 90° boss connectors for 40 and
50mm PVCc or ABS waste pipework.
Vertical pipes
The transition between vertical and horizontal pipework should be achieved using two 45° bends
or a single 87½° long radius bend with a support bracket positioned as close as possible.
Horizontal connections
The SWS4135 boss pipe is recommended for
Branch connections use in horizontal situations where connections
1.2m max.
All branch connections into horizontal pipework should be made at 45° to ensure the discharge to 110mm diameter pipe is made at 45°.
angle brace
is swept in the direction of flow. This fitting has a 50mm solvent weld socket
to accept PVCc or ABS waste pipes.
Structural fixings 750mm max.
It is recommended that 6mm rawlbolt or similar proprietary fixings are used to secure base or 1.0m with
plate
side bracing SY405 SY405 32, 40 or
and angle cleats to the structure. branch branch 50mm pipe
intermediate
bracket 110mm pipe

anchor bracket

1.0m

Single support Double support Boss pipe connections


Four different types of fitting are available to provide alternative methods of connecting small diameter waste pipes to 82, 110 and 160mm vertical
discharge stacks.
110mm 110mm
Single boss pipes. Strap-on-bosses.
see table
see table
Available with ring seal or solvent Primarily designed to permit 32, 40
weld sockets for push-fit or solvent and 50mm waste pipe connections
angle brace
weld jointing, single boss pipes to be made to existing 110mm PVCu
angle brace allow 32, 40 and 50mm waste pipe discharge stacks, strap-on-bosses
500mm max. connections to be made at 87½° SWS415/ can also be used on new systems to SWS4150
or 600mm with SWS41 /410/420
side bracing 1.0m max.
direct to the vertical stack. provide flexibility of installation during
110mm pipe or 1.2m with different stages of construction.
side bracing
110mm pipe
anchor bracket
anchor bracket SW30/40
82mm
Multiple entry boss pipes. boss branch Patch bosses.
intermediate bracket

intermediate bracket Supplied in ring seal or solvent weld SA411/421/420


Suitable for solvent weld jointing to
SWS332
options, all have 90° boss upstands boss connector new and existing 82mm diameter /340/350
moulded on each fitting with one PVCu discharge stacks to accept
inlet port open. Connection is made 32, 40 and 50mm size PVCc or ABS
using the appropriate size Marley waste pipework.
boss connector to suit 32, 40 or
50mm waste pipes. 32, 40 or 50mm pipe

1.2m max.

angle brace

42 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 43
750mm max.
or 1.0m with
110mm 110mm ST40W SWCB90 SWCB90
ST40W 110mm 110mm
push-fit WC push-fit WC
solvent solvent
connector connector
WC connector WC connector
Installation data 110mm ST40W 110mm
SWCB90
push-fit WC
solvent
connector
WC connector

WC connections WC manifold system


Two different types of connectors are available to allow connection to connectors are used, the WC socket must be trimmed to suit the length
vitreous china or stainless steel WC pans, slop hoppers and other similar of pan spigot before the SA323W is solvent welded in position. Up to six WCs can be connected to a soil stack using the WC manifold system and a single branch NUMBER ANGLE OF MANIFOLD BRANCH
sanitary equipment. Manufactured in PVC and eva (ethylene vinyl acetate) connection. By using a double branch connection, an additional six WCs can be connected. OF WCs
WC 1 WC 2 WC 3 WC 4 WC 5 WC 6
Ground floor toilets often have their own connection to the building The table, right, details the angles of the manifolds for this installation.
to accommodate a range of outlet sizes between 84 and 110mm sanitary 6 80° 75° 70° 65° 60° 55°
drain to eliminate pipework and ducting. Where this occurs both types
pipework or underground drainage.
of connector are suitable for push-fit or solvent weld jointing to the 5 75° 70° 65° 60° 55°
SGS41W SGS41W
The 90º ST40W, ST41W and SG40W connectors are supplied complete 110mm PVC drain.
110mm solvent
with flexible seal and110mm
solvent 110mm
retaining cap. Where the SGS41W or STS41W pan110mm
4 70° 65° 60° 55°

WC connector WC connector 3 65° 60° 55°


110mm SWCB90
ST40W 110mm 2 60° 55°
push-fit WC
solvent
SWCB90 SGS41W connector
110mm ST40W WC connector
110mm
push-fit WC solvent
110mm 110mm
solvent WC connector
450mm 900mm 900mm 900mm
connector
WC connector 70° 65° 60° 55°

*126mm
SWC11 SWC11
SA323W SA323W push-fit push-fit
WC seal and WC seal and WC connector WC connector
retaining cap retaining cap F.F.L

SWC11 Dimension (*) based on 190mm centre outlet WC pans and SM43W adjustable spigot bends cut to the angles shown.

SA323W push-fit
WC seal and WC connector
retaining cap

1. Select the adjustable bend angle required 2. File away any rough edges from the face 3. Apply a uniform coat of Marley solvent
SGS41W from the above diagram according to the of the fitting and wipe clean the bend and cement, to the short branch radial
110mm
SWCB90 solvent 110mm WC position. Cut the bend with a hacksaw, branch, with a dry cloth. Before jointing, socket and to the external surface
T40W 110mmSGS41W
push-fit WCWC connector
removing the unwanted portion. the bend and branch should be checked for of the bend body.
lvent 110mm solvent 110mm
position and alignment, both parts being
connector
C connector WC connector
marked to ensure accurate assembly.

SM41

SWC11
SA323W push-fit
WC seal and SWC11 WC connector
SA323W retaining cap push-fit
WC seal and WC connector SM42/SM43 SM42/SM43 SM42/SM43
retaining cap
4. Assemble the branch immediately, insuring 5. Trim the WC socket to suit the toilet pan To accommodate varying dimensions between
that the marked lines on the fitting coincide. spigot length and remove any swarf with the WC spigot and the centre line of the
ST40W ST40W SWCB90 SWCB90
Do not twist the two parts of the branch a file. Place the seal in the socket, apply a horizontal pipe run, the adjustable spigot bend
solvent WC connector
solvent WC connector push-fit WC connector
push-fit WC connector during this operation, but maintain steady uniform coat of solvent cement about 15mm SM43 or extension pipe SM45 can be used with
pressure until the spigot of the bend comes wide to the outside of the socket and inside WC connector SM44.
110mm
to rest against the internal surface of the the retaining cap. Push onto the socket and
ctor
branch socket. Quickly wipe off any surplus wipe off any surplus solvent cement.
ST40W SWCB90
solvent cement from the inside and outside
solvent WC connector push-fit WC connector of the completed joint and hold in position
for approximately 15 seconds.

SM41
SM41

SWC11
W push-fit SA323
al and 110mm 110mm
WC connector 110mm 110mm cap and seal

ng cap PVCu drain PVCu drain PVCu drain PVCu drain


SM42/SM43
SM42/SM43

110mm 110mm
PVCu drain PVCu drain

44 | MARLEY PVC Soil & Waste ST40W SWCB90


All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 45
solvent WC connector push-fit WC connector
Fabrications Service Site Work

Inspection and testing Handling Safety


Inspection and testing should be carried out PVCu pipes are strong, though lightweight The relevant regulations are outlined in the
in accordance with BS EN 12056: 2000 and and therefore very easily handled. However, Health and Safety At Work Act 1974 and
Building Regulations noting especially the reasonable care should be exercised while The Construction (Design and Management)
details given in respect of air testing and the handling, particularly in extremely cold conditions. Regulations 1994 and should be followed.
Quality Product Technical Services fact that smoke testing of plastics pipework Pipes should preferably be loaded and unloaded Hazard sheets, dealing with the correct
should be avoided as the materials can be by hand but if mechanical handling is used, storage, use, and any hazards of working
The Marley HDPE range Our team of experts will provide support adversely affected. protected slings are recommended. with solvent cement, silicone lubricant and
is the only system in the throughout the design process, creating fire protection products are available from
Air test Maintenance Marley Plumbing & Drainage.
UK certified to BS EN 1519. drawings for each stack element and liaising
The installation should be capable of Provided that the system is designed and installed
with our fabrications team to ensure that
withstanding an air test of positive pressure correctly, no maintenance will be required.
every detail is to specification. of at least 38mm water gauge for at least 3
If blockage does occur, use only flexible or roller
minutes. During this time every trap should
type rods. Pointed or bearing type metal fittings
maintain a water seal of at least 25mm.
are not recommended. Tests have been carried
out on PVCu pipes and fittings using equipment
from specialist drain cleaning contractors and
their standard equipment is suitable.
The Fabrications Team
Our dedicated team of skilled fabricators
will pre-build the HDPE soil stacks in a
controlled factory environment, to project
specifications and to the highest quality,
with pressure testing to BS EN 12056-2
on every stack as standard.

Storage
Pipes should be stacked on a reasonably flat, sockets at alternate ends protruding to ensure
On Site Support level surface on timber battens not less than pipes are evenly supported along their length.
75mm wide spaced at a maximum of 1m
Pipes should not be stacked more than 7 high
This is useful for particularly complex centres. Side support should also be provided
and when stored in the open for long periods,
installations, where our years of industry at intervals of not more than 1.5m.
or exposed to strong sunlight, they should be
experience may be beneficial. Different size pipes should be stacked separately. covered with an opaque sheet. Fittings supplied
However, where this is not possible, larger in cardboard boxes or polythene bags should
diameter pipes should be placed at the bottom. be stored under cover and kept packed until
required. Solvent cement should be stored in
Spigot and socket pipes should be stacked
a cool place out of direct sunlight and away
separately. However, where this is not possible,
from any heat source.
larger diameter pipes should be stacked with

Delivered when and


where you need it
Following drawing sign off, a delivery
schedule is agreed.
Deliveries will arrive to the agreed schedule,
saving precious space on site.

Why choose a fabricated system?

Saves time ££ Saves money Saves storage Saves waste

Delivery when
Expertise Simplification Quality, assured
you need it

46 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 47
Standards

British & European Standards


BS EN 1329-1: 2014 BS EN 1566-1: 2000 BS EN 14680: 2015
Plastics piping systems for soil and waste Specification for thermoplastics waste pipe Specification for adhesives for non-pressure
discharge (low and high temperature) and fittings. thermoplastics pipe systems.
within the building structure – PVCu.
BS 5255: 1989 BS EN 681-1: 1996
BS EN 1451-1: 2000 Specification for thermoplastics waste pipe Elastomeric seals. Material requirements for
Plastics piping systems for soil and waste and fittings. pipe joint seals used in water and drainage
discharge (low and high temperature) within applications. Part 1 vulcanised rubber.
the building structure – polypropylene. BS EN 1455-1: 2000
Plastics piping systems for soil and waste BS EN ISO 9001: 2015
BS EN 1519-1: 2000 (low and high temperature) within the Quality systems. Model for Quality
Plastics piping systems for soil and waste building structure – ABS. Assurance in Design, Development,
discharge (low and high temperature) within Production, Installation and Servicing.
the building structure – polyethylene. BS 5627: 1984
Specification for plastics connectors BS EN ISO 14001: 2015
BS 4514: 2001 for use with horizontal outlet vitreous Environmental management systems.
Specification for PVCu soil and ventilating china WC pans. Requirements with guidance for use.
pipes, fittings and accessories.

Accreditations
AT
ER INDUSTR Case study
TIFIE TO W

Leicester Student Accommodation


SP
ECIFICAT
D

Hundreds of en-suite shower pods were installed during the


ER

ON
I

BS EN 1329-1 : 2000 construction of a student accommodation building in the East


Certificate No. 06/4325
BS 4514 : 2001 BS EN ISO 9001: 2008 Midlands using the Marley PVCu soil and waste system, and in
BS EN 1566-1: 2000 BS EN ISO 14001: 2004
BS 5255: 1989 particular, the eight-way collar boss.
BS EN 1455-1: 2000
BS EN 1451-1: 2000 “We have come to rely on Marley for their technical advice. Particularly
BS EN 1519-1: 2000
in situations such as this one. We wanted Marley involved from an early
stage to be able to advise and steer the design process”
£
Products indicated by this symbol comprise of components not covered by Marley Plumbing and Dave Gourley, Project Manager
Drainage BS EN ISO 9001 Scope of Registration. However these products have been fully inspected H Malone and Sons Ltd
and tested in accordance with our own Quality Management System requirements.

48 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 49
Technical Services Marley system solutions

An acoustic soil and waste range with Marley Akatherm HDPE is a drainage The Multikwik brand is known and trusted
a layered pipe providing quick, hygienic system which offers an alternative solution by plumbers for its sanitary frames, cisterns,
removal of sanitary waste water. to cast iron. It is particularly suited for traps, compression waste systems and
The noise generated by the flow of water commercial applications or where a market leading range of pan connectors.
is dramatically reduced – making it perfect product with high impact or abrasion Complementing the Marley range it
for multi-occupancy apartment blocks resistance is required, such as hospitals, provides an excellent solution to modern
and high specification developments. hotels, schools, as well as residential bathroom design with a wide choice
buildings. HDPE will also cope with of product options.
temperature variations of -40°C to
100°C making it ideal for external
as well as internal installations.

Designing the most efficient drainage system for a project is a skill for which the Marley Technical Services team are
renowned. Marley Plumbing & Drainage provide technical support to all those involved with the specification and
installation of our products.

Our technical team can help you specify the system you need
Years of experience mean that we can support you throughout your tender process and assist with any technical
and installation requirements.

The Marley Plumbing & Drainage range Five gutter profiles and three downpipe Foundry Finish
DESIGN
SERVICES ££ VALUE
ENGINEERING
TECHNICAL
ADVICE
FABRICATIONS
SERVICE
of underground systems include the
solid wall range, predominately for
options provide a rainwater solution
for any application. Advanced Life4
Foundry Finish is a cast-iron
effect PVCu system, offering a
round the house drainage and Quantum technology on four of the key profiles, great combination of traditional
structured wall range for sewer and coupled with the benefits of the Easyclip good looks with modern
RAINWATER MATERIAL CAD BIM
CALCULATIONS TAKE-OFFS FILES OBJECTS highway drainage applications. and notching capability combine to make lightweight materials
the Marley rainwater range the most
IN-HOUSE comprehensive available.
FIELD AND SPECIAL
SPECIFICATION AND EXTERNAL
SITE SUPPORT FABRICATIONS
TRAINING

CPD
SEMINARS

50 | MARLEY PVC Soil & Waste MARLEY PVC Soil & Waste | 51
marleypd.co.uk
For general enquiries and details of your
nearest stockist please call the customer
services department:
Tel: 01622 852585
Email: customerservice@marleypd.co.uk

To place an order
For delivery to England & Wales
Email: orders.lenham@marleypd.co.uk
Fax: 01622 851111
For delivery to Scotland
Email: orders.uddingston@marleypd.co.uk
Fax: 01698 810307

For all estimate requests


Email: estimates@marleypd.co.uk

For Technical advice please call


01622 852695

Head Office
Lenham, Maidstone
Kent ME17 2DE
Tel: 01622 858888
Fax: 01622 858725
Email: marketing@marleypd.co.uk

Scotland
Birkenshaw Industrial Estate
Uddingston, Glasgow G71 5PA
Tel: 01698 815231
Fax: 01698 810307

Export Division
Lenham, Maidstone
Kent ME17 2DE England
Tel: +44 (0)1622 858888
Fax: +44 (0)1622 850778
Email: export@marleypd.co.uk