Beruflich Dokumente
Kultur Dokumente
Literature
www.hiwinmikro.com.tw
High speed High precision Multifunctional integration Ecology first Humanistic technology
TAIWAN EXCELLENCE
GOLD AWARD 2008
TAIWAN EXCELLENCE Positioning
SILVER AWARD 2007, 2002
Measurement System
Linear Guideway
HG/EG/RG/MG Type
• Self-Lubricating (E2)
• Low Noise (Q1)
• Air Jet (A1)
TAIWAN EXCELLENCE
SILVER AWARD 2006
TMS Direct-Drive Linear Motor X-Y Robot
Positioning System
TAIWAN EXCELLENCE
2004
Positioning Guideway Linear Motor Gantry
Index
1. Sizing of a HIWIN Linear Actuator ............................................................................................................................................................... 2
2. Installation of a HIWIN Linear Actuator ...................................................................................................................................................... 2
3. Regulations to Safely Operate HIWIN Linear Actuators ............................................................................................................................ 2
4. Features & Applications .............................................................................................................................................................................. 3
5. HIWIN LAM Series (1) ................................................................................................................................................................................... 4
6. HIWIN LAM Series (2) .................................................................................................................................................................................. 6
7. HIWIN LAM Series (3) ................................................................................................................................................................................... 8
8. HIWIN LAI Series (1) ................................................................................................................................................................................... 10
9. HIWIN LAI Series (2) .................................................................................................................................................................................... 12
10. HIWIN LAS Series (1) ................................................................................................................................................................................ 14
11. HIWIN LAS Series (2) ............................................................................................................................................................................... 16
12. HIWIN LAS Series (3)................................................................................................................................................................................ 18
13. HIWIN LAS Series (4)................................................................................................................................................................................ 20
14. HIWIN LAS Series (5)................................................................................................................................................................................ 22
15. HIWIN LAN Series (1) ............................................................................................................................................................................... 24
16. HIWIN LAN Series (2) ............................................................................................................................................................................... 26
17. HIWIN LAN Series (3) ............................................................................................................................................................................... 28
18. HIWIN LAN Series (4) ............................................................................................................................................................................... 30
19. HIWIN LAN Series (5) ............................................................................................................................................................................... 32
20. HIWIN LAC Series (1) ............................................................................................................................................................................... 34
21. HIWIN LAC Series (2) ............................................................................................................................................................................... 36
22. HIWIN 1-Axis Controller .......................................................................................................................................................................... 38
23. HIWIN 2-Axis Controller (1) ..................................................................................................................................................................... 40
24. HIWIN 2-Axis Controller (2) ..................................................................................................................................................................... 42
25. HIWIN 2-Axis Controller (3) ..................................................................................................................................................................... 44
26. HIWIN 2-Axis Controller .......................................................................................................................................................................... 46
27. HIWIN 3-Axis Controller .......................................................................................................................................................................... 49
28. HIWIN 4-Axis Controller .......................................................................................................................................................................... 51
29. HIWIN 6-Axis Controller .......................................................................................................................................................................... 53
30. HIWIN Battery .......................................................................................................................................................................................... 56
31. HIWIN Over Current Protection Box ........................................................................................................................................................ 57
32. HIWIN Keypad Series ............................................................................................................................................................................... 59
33. Standard Cable length of the actuator .................................................................................................................................................... 67
34. HIWIN LAP4G Mask Options .................................................................................................................................................................... 69
35. HIWIN Options for each Actuator Type .................................................................................................................................................... 71
36. HIWIN Option for each Controller Type ................................................................................................................................................... 72
37. HIWIN Customer Requirements (LA) ...................................................................................................................................................... 73
1
Linear Actuator
Introduction
2
4. Features & Applications
4-2 Applications
Automation equipment
Automatic cupboards
Entertainment facilities
Household appliances
Patient lifters
Massage chairs
Traffic facilities
Office automation
Automatic PC desks
Nursing homes
3
Linear Actuator
LAM Series
Ø12.2±0.1 Ø12.2±0.1
29
27
(150)
MOTOR CABLE RL
19 (123) 27
MOTOR CABLE LENGTH=1000mm
Ø63.5
78
14 21 (19.3) 13
Ø33
Ø50
• LAM1-1/-2 • LAM1-1A
RL = S+153 RL = S+162
Stroke ≤ 400 Stroke ≤ 400
RL = S+203 RL = S+212
Stroke > 400 Stroke > 400
RL: Retracted length
S: Stroke length
4
Table 5.2 LAM1 Specifications
Model Screw
Thrust Pulling Holding Speed Standard stroke Duty Current max.
type
max. max. max. (mm / s) (mm) : S cycle (A)
(N) (N) (N) Load = Max . / Load = 0 % 12VDC 24VDC
LAM1-1 Ballscrew 4000 3000 4000 8 / 11 100 150 200 250 300 350 400 10 12 6
LAM1-2 Ballscrew 2000 2000 1200 16 / 21 100 150 200 250 300 350 400 10 12 6
LAM1-1A ACME 3000 3000 3000 8 / 11 100 150 200 250 300 350 400 10 12 6
*Min. input power = Voltage x Current max.
LAM1-1/ -2 / -1A
24(12)VDC Motor
25
20
LAM1-1
Speed (mm/s)
15 LAM1-2
10 LAM1-1A
5
0
0 500 1000 1500 2000 2500 3000 3500 4000
Load (N)
LAM1-1/ -2 / -1A
24 VDC Motor
6
5
4 LAM1-1
Current (Amp)
3 LAM1-2
LAM1-1A
2
1
0
0 500 1000 1500 2000 2500 3000 3500 4000
Load (N)
**Note: The test results are obtained by using the 24VDC power supply.
LAM1-1/ -2 / -1A
12 VDC Motor
12
10
8 LAM1-1
Current (Amp)
6 LAM1-2
LAM1-1A
4
2
0
0 500 1000 1500 2000 2500 3000 3500 4000
Load (N)
**Note: The test results are obtained by using the 12VDC power supply.
Ordering Information
LAM1 - 1 - 0 - 200 - 24 E
Model number 0 : Basic model (without magnet) Stroke length Voltage Special models according to the customer’s requirement
(Ballscrew: 1,2) 1 : Complete with external limit switches (Ignore this part of the serial number if not available)
(ACME: 1A)
5
Linear Actuator
LAM Series
RL
110
Ø25.9
6.2
38
.1
Ø8
71
(11.5)
.1
Ø10
MOTOR CABLE
25 46 MOTOR CABLE LENGTH=1000mm
Ø25.9
Ø19
6.2
25
45
34
136
111
42
• RL = S+157
Stroke ≤ 300
RL = S+207
Stroke > 300
RL: Retracted length
S: Stroke length
6
Table 6.2 LAM2 Specifications
Model Thrust Pulling Holding Speed Standard stroke Duty Current max. MR Sensor
max. max. max. (mm / s) (mm) : S cycle (A) Resolution
(N) (N) (N) Load = Max. / Load = 0 % 12VDC 24VDC (mm / pulse)
LAM2-1 3500 3500 3000 2 / 3.5 100 150 200 250 300 10 8 4 0.1
LAM2-2 2500 2500 2000 3/6 100 150 200 250 300 10 8 4 0.16
LAM2-3 1500 1500 1500 6.5 / 12 100 150 200 250 300 10 6 3 0.32
LAM2-4 1200 1200 800 8 / 14 100 150 200 250 300 10 6 3 0.4
*Min. input power = Voltage x Current max.
24(12)VDC Motor
LAM2-1/ -2 / -3 / -4
14
12
10 LAM2-1
Speed (mm/s)
8 LAM2-2
6 LAM2-3
4 LAM2-4
2
0
0 500 1000 1500 2000 2500 3000 3500 4000
Load (N)
LAM2-1/ -2 / -3 / -4
24 VDC Motor
4.0
3.5
3.0
LAM2-1
Current (Amp)
2.5
LAM2-2
2.0
LAM2-3
1.5 LAM2-4
1.0
0.5
0
0 500 1000 1500 2000 2500 3000 3500 4000
Load (N)
**Note: The test results are obtained by using the 24VDC power supply.
LAM2-1/ -2 / -1A
12 VDC Motor
8
7
6
LAM2-1
Current (Amp)
5
LAM2-2
4
LAM2-3
3
LAM2-4
2
1
0
0 500 1000 1500 2000 2500 3000 3500 4000
Load (N)
**Note: The test results are obtained by using the 12VDC power supply.
Ordering Information
LAM2 - 1 - 1 - 200 - 24 G E
Model number 0 : Without internal limit switches Stroke length Voltage Color Special models according to the customer’s requirement
1 : Basic model complete with internal limit B : Black (Ignore this part of the serial number if not available)
switches G : Gray
7
Linear Actuator
LAM Series
Ø10 +0.2
-0
Ø25
6.2
Ø25.4
RL
154
52 141.5
39.7 83
11
15
13 (20.5)
14
32.7
66.5
28
81
98
21.5
83
Ø10+0.2
-0
Ø25.9
MOTOR CABLE
MOTOR CABLE LENGTH=1000mm
• RL = S+171
Stroke ≤ 300
RL = S+221
Stroke > 300
RL: Retracted length
S: Stroke length
8
Table 7.2 LAM3 Specifications
Model Thrust Pulling Holding Speed Standard stroke Duty Current max.
max. max. max. (mm / s) (mm) : S cycle (A)
(N) (N) (N) Load = Max. / Load = 0 % 12VDC 24VDC
LAM3-1 6000 5000 5000 4 / 5.5 100 150 200 250 300 350 400 10 12 6
LAM3-2 4000 4000 4000 5.5 / 7.5 100 150 200 250 300 350 400 10 10 5
LAM3-3 3000 3000 3000 7/9 100 150 200 250 300 350 400 10 8 4
LAM3-4 2000 2000 1500 11.5 / 14.5 100 150 200 250 300 350 400 10 8 4
*Min. input power = Voltage x Current max.
LAM3-1/ -2 / -3 / -4
24(12) VDC Motor
20
15 LAM3-1
Speed (mm/s)
LAM3-2
10
LAM3-3
5 LAM3-4
0
0 1000 2000 3000 4000 5000 6000
Load (N)
LAM3-1/ -2 / -3 / -4
24 VDC Motor
6
5
Current (Amp)
4 LAM3-1
LAM3-2
3
LAM3-3
2 LAM3-4
1
0
0 1000 2000 3000 4000 5000 6000
Load (N)
**Note: The test results are obtained by using the 24VDC power supply.
LAM3-1/ -2 / -3 / -4
12 VDC Motor
12
10
LAM3-1
Current (Amp)
8
LAM3-2
6 LAM3-3
4 LAM3-4
2
0
0 1000 2000 3000 4000 5000 6000
Load (N)
**Note: The test results are obtained by using the 12VDC power supply.
Ordering Information
LAM3 - 1 - 1 - 300 - 24 G E
Model number 0 : Without internal limit switches Stroke length Voltage Color Special models according to the customer’s requirement
1 : Basic model complete with internal limit B : Black (Ignore this part of the serial number if not available)
switches G : Gray
9
Linear Actuator
LAI Series
31
Ø21.9
11 (22) 19 15
215 92.75
• LAI1-1A
Ø59.5
RL = S+190
Stroke ≤ 300 1
R11
127.75
RL = S+240
Ø21.9
Ø28
RL: Retracted length
Ø39
S: Stroke length
Ø46
RL
• LAI1-1
MOTOR CABLE
MOTOR CABLE LENGTH=1000mm
Ø14.2±0.1 Ø14.2±0.1
31
31
15 22.3 19 15 92.75
215
• LAI1-1
RL = S+170
Ø59.5
Stroke ≤ 300
RL = S+220 1
R11
127.75
S: Stroke length
Ø39
Ø46
RL
10
Table 8.2 LAI1 Specifications
Model Screw
Thrust Pulling Holding Speed Standard stroke Duty Current max.
type
max. max. max. (mm / s) (mm) : S cycle (A)
(N) (N) (N) Load = Max. / Load = 0 % 12VDC 24VDC
LAI1-1 Ballscrew 4000 4000 1200 6/9 100 150 200 250 300 10 8 4
LAI1-1A ACME 4000 4000 3000 6/9 100 150 200 250 300 10 10 5
*Min. input power = Voltage x Current max.
LAI1-1/ -1A
24(12) VDC Motor
10
Speed (mm/s)
8
LAI1-1
LAI1-1A
6
4
0 1000 2000 3000 4000
Load (N)
LAI1-1/ -1A
24 VDC Motor
5
4
Current (Amp)
3 LAI1-1
2 LAI1-1A
1
0
0 1000 2000 3000 4000
Load (N)
**Note: The test results are obtained by using the 24VDC power supply.
LAI1-1/ -1A
12 VDC Motor
10
8
Current (Amp)
6 LAI1-1
4 LAI1-1A
2
0
0 1000 2000 3000 4000
Load (N)
**Note: The test results are obtained by using the 12VDC power supply.
Ordering Information
LAI1 - 1 - 0 - 200 - 24 E
Model number 0: Basic model (without magnet) Stroke length Voltage Special models according to the customer’s requirement
(Ballscrew: 1) 1: Complete with external limit switches (Ignore this part of the serial number if not available)
(ACME: 1A)
11
Linear Actuator
LAI Series
RL
76 142
• RL = S+276 76.5
Ø12 +0.1
76
Ø56
-0.05
Stroke ≤ 300 Ø12+0.1
-0.05
RL = S+326
38
Ø28
Ø27
Stroke ≤ 700 14 22
145.5
24 13
145
• RL = S+322 RL
76 188 76.5
Stroke ≤ 300 Ø12 +0.1
76
Ø56
-0.05
RL = S+372 Ø12 +0.1
-0.05
38
Stroke ≤ 700
Ø27
Ø28
RL = S+422 14 22
145.5
24 13
145
12
Table 9.2 LAI2 Specifications
Model Screw Thrust Pulling Holding Speed Standard stroke Duty Current Hall Sensor
type max. max. max. (mm / s) (mm) : S cycle max. Resolution
(N) (N) (N) Load = Max. / Load % (A) (mm/pulse)
=0 24VDC
LAI2-1 Ballscrew 12000 10000 12000 2 / 2.5 100 150 200 250 300 10 3 1.26
LAI2-2 Ballscrew 8000 8000 8000 4/5 100 150 200 250 300 10 4 2.54
*The max. stroke lengths: 1000mm
*Min. input power = Voltage x Current max.
LAI2-1/ -2
24 VDC Motor
5
4
Speed (mm/s)
3 LAI2-1
2 LAI2-2
1
0
0 2000 4000 6000 8000 10000 12000
Load (N)
**Note: The test results are obtained by using the 24VDC power supply.
LAI2-1/ -2
24 VDC Motor
5
4
Current (Amp)
3 LAI2-1
2 LAI2-2
1
0
0 2000 4000 6000 8000 10000 12000
Load (N)
Ordering Information
LAI2 - 1 - 0 - 200 - 24 E
Model number 0: Basic model (without magnet) Stroke length Voltage Special models according to the customer’s requirement
1: Complete with external limit switches (Ignore this part of the serial number if not available)
13
Linear Actuator
LAS Series
40
(100) 5
Ø38
2-Ø8.1±0.1
Ø19
73.5
83
Ø18.8
Ø18
19.5
9.5
• RL = S+119
Stroke ≤ 250
RL = S+169
Stroke > 250
RL : Retracted length
S : Stroke length
14
Table 10.2 LAS1 Specifications
Model Thrust Pulling Holding Speed Standard stroke Duty Current max.
max. max. max. (mm / s) (mm) : S cycle (A)
(N) (N) (N) Load = Max. / Load = 0 % 12VDC 24VDC
LAS1-1 1200 1200 800 8 / 12 50 100 150 200 250 10 6 2.5
LAS1-2 600 600 300 16 / 25 50 100 150 200 250 10 6 3
*Min. input power = Voltage x Current max.
LAS1-1/ -2
24(12) VDC Motor
30
25
20
Speed (mm/s)
15 LAS1-1
LAS1-2
10
5
0
0 200 400 600 800 1000 1200
Load (N)
LAS1-1/ -2
24 VDC Motor
3.0
2.5
2.0
Current (Amp)
LAS1-1
1.5
LAS1-2
1.0
0.5
0
0 200 400 600 800 1000 1200
Load (N)
**Note: The test results are obtained by using the 24VDC power supply.
LAS1-1/ -2
12 VDC Motor
6
5
4
Current (Amp)
3 LAS1-1
LAS1-2
2
1
0
0 200 400 600 800 1000 1200
Load (N)
**Note: The test results are obtained by using the 12VDC power supply.
Ordering Information
LAS1 - 1 - 1 - 200 - 24 G E
Model number 0 : Without internal limit switches Stroke length Voltage Color Special models according to the customer’s
1 : Basic model complete with internal limit B : Black requirement (Ignore this part of the serial
switches G : Gray number if not available)
15
Linear Actuator
LAS Series
MOTOR CABLE
MOTOR CABLE LENGTH=1000mm 4.5 (128) 48
22
Ø42 2-Ø8.1±0.1
Ø19
80.5
82.5
37
Ø18.8
Ø18
21.5
8 12 63 (RL-102) (27) 27
RL 9.4 31
• RL = S+146
Stroke ≤ 250
RL = S+196
Stroke > 250
RL: Retracted length
S: Stroke length
Table 11.1 Specifications Table 11.2 Position feedback specifications (Optical Sensor)
Screw type ACME Supply voltage 24VDC 12VDC 5VDC
Weight* 1.3kg High level 24VDC High level 12VDC TTL
Protection IP54 Output Low level 0.2V/40mA PNP* Low level 0.2V/40mA PNP*
Compatible with all controllers PS. Open collector PS. Open collector
Compatible controller
(*Notice the type of connector: Audio/DIN 4pin) * Low noise
Working temp. +5oC~40oC
* Stroke length 200mm
Ø8.1 +0.2
-1
Option:
(1) IP65 (3) 36VDC motor
(2) Position feedback (4) Back fixture turned 90o
1: Potentiometer 10k ohm (RL = S+154 , S ≤ 250 / RL = S+204 , S > 250) (5) Rod end with flat connector (RL = S+133 , S ≤ 250 / RL = S+183 , S > 250)
2: Optical sensor: PNP (standard), NPN. TTL (6) Plug: DIN 4PIN plug / Stereo plug / Mono plug Flat connector
16
Table 11.3 LAS2 Specifications
Model Thrust Pulling Holding Speed Standard stroke Duty Current max. Optical Sensor Potentiometer
max. max. max. (mm / s) (mm) : S cycle (A) Resolution Resolution
(N) (N) (N) Load = Max. / Load = 0 % 12VDC 24VDC (mm/pulse) (Ohm/mm)
LAS2-1 1800 1200 1800 4.5 / 7 50 100 150 200 250 10 6 3 0.3175 21
LAS2-2 1200 1200 1000 8 / 15 50 100 150 200 250 10 6 3 0.635 10.5
*Min. input power = Voltage x Current max.
LAS2-1/ -2
24(12) VDC Motor
16
14
12
10
Speed (mm/s)
8 LAS2-1
6 LAS2-2
4
2
0
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Load (N)
LAS2-1/ -2
24 VDC Motor
6
5
Current (Amp)
4
LAS2-1
3
LAS2-2
2
1
0
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Load (N)
**Note: The test results are obtained by using the 24VDC power supply.
LAS2-1/ -2
12 VDC Motor
6
5
Current (Amp)
4
3 LAS2-1
LAS2-2
2
1
0
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Load (N)
**Note: The test results are obtained by using the 12VDC power supply.
Ordering Information
LAS2 - 1 - 1 - 200 - 24 G E
Model number 0 : Without internal limit switches Stroke length Voltage Color Special models according to the customer’s
1 : Basic model complete with internal limit switches B : Black requirement (Ignore this part of the serial
G : Gray number if not available)
17
Linear Actuator
LAS Series
MOTOR CABLE
4.5 (119)
MOTOR CABLE LENGTH=1000mm
48
24
Ø38 2-Ø8.1±0.1
Ø19
80.5
82.5
Ø18.8
Ø18
21.5
27
8 12 61 (RL-102) (29)
RL 9.4 31
• RL = S+146
Stroke ≤ 250
RL = S+196
Stroke > 250
RL: Retracted length
S: Stroke length
Table 12.1 Specifications Table 12.2 Position feedback specifications (Optical Sensor)
Screw type ACME Supply voltage 24VDC 12VDC 5VDC
Weight* 1.27kg High level 24VDC High level 12VDC TTL
Protection IP54 Output Low level 0.2V/40mA PNP* Low level 0.2V/40mA PNP*
Compatible with all controllers PS. Open collector PS. Open collector
Compatible controller
(*Notice the type of connector: Audio/DIN 4pin)
Working temp. +5oC~40oC
* Stroke length 200mm
Ø8.1 +0.2
-1
Option:
(1) IP65 (3) 36VDC motor
(2) Position feedback (4) Back fixture turned 90o
1: Potentiometer 10k ohm (RL = S+154 , S ≤ 250 / RL = S+204 , S > 250) (5) Rod end with flat connector (RL = S+133 , S ≤ 250 / RL = S+183 , S > 250)
2: Optical sensor: PNP (standard), NPN. TTL (6) Plug : DIN 4PIN plug / Stereo plug / Mono plug Flat connector
18
Table 12.3 LAS3 Specifications
Model Thrust Pulling Holding Speed Standard stroke Duty Current max. Optical Sensor Potentiometer
max. max. max. (mm / s) (mm) : S cycle (A) Resolution Resolution
(N) (N) (N) Load = Max. / Load = 0 % 12VDC 24VDC (mm/pulse) (Ohm/mm)
LAS3-1 1200 1200 800 8 / 12 50 100 150 200 250 10 6 2.5 0.3175 21
LAS3-2 600 600 300 16 / 25 50 100 150 200 250 10 6 3 0.635 10.5
*Min. input power = Voltage x Current max.
LAS3-1/ -2
24(12) VDC Motor
30
25
Speed (mm/s)
20
LAS3-1
15 LAS3-2
10
5
0
0 200 400 600 800 1000 1200
Load (N)
LAS3-1/ -2
24 VDC Motor
3.0
2.5
Current (Amp)
2.0
1.5 LAS3-1
1.0 LAS3-2
0.5
0
0 200 400 600 800 1000 1200
Load (N)
**Note: The test results are obtained by using the 24VDC power supply.
LAS3-1/ -2
12 VDC Motor
6
5
Current (Amp)
4
3 LAS3-1
LAS3-2
2
1
0
0 200 400 600 800 1000 1200
Load (N)
**Note: The test results are obtained by using the 12VDC power supply.
Ordering Information
LAS3 - 1 - 1 - 200 - 24 G E
Model number 0 : Without internal limit switches Stroke length Voltage Color Special models according to the customer’s
1 : Basic model complete with internal limit B : Black requirement (Ignore this part of the serial
switches G : Gray number if not available)
19
Linear Actuator
LAS Series
5
MOTOR CABLE
MOTOR CABLE LENGTH=1000mm
Ø6.2±0.1 .8
Ø6.1+0.1 Ø18
29.5
-0
45
15.5
4 8.5 (27.5) 5
15 7 RL 9.4
45
• RL = S+222.5
Stroke ≤ 300
RL = S+272.5
Stroke > 300
RL: Retracted length
S: Stroke length
Table 13.1 Specifications Table 13.2 Position feedback specifications (Optical Sensor)
Screw type ACME Supply voltage 24VDC 12VDC 5VDC
Weight* 1.36kg High level 24VDC High level 12VDC TTL
Output
Protection IP54 Low level 0.2V / 10mA sink (NPN) Low level 0.2V / 10mA sink (NPN)
Compatible with all controllers
Compatible controller
(*Notice the type of connector: Audio/DIN 4pin) Option:
Working temp. +5oC~40oC
* Stroke length 200mm (1) IP65
(2) Hall sensor (RL = S+226 , S ≤ 300 / RL = S+276 , S > 300)
(3) Plug: DIN 4PIN plug/Stereo plug/Mono plug
20
Table 13.3 LAS4 Specifications
Model Thrust Pulling Holding Speed Standard stroke Duty Current max. Hall Sensor
max. max. max. (mm / s) (mm) : S cycle (A) Resolution
(N) (N) (N) Load = Max. / Load = 0 % 12VDC 24VDC (mm/pulse)
LAS4-1 800 800 600 10 / 15 100 150 200 250 300 10 5 2.3 0.0085
LAS4-2 300 300 200 30 / 46 100 150 200 250 300 10 6 3.6 0.02
*Min. input power = Voltage x Current max.
LAS4-1/ -2
24(12) VDC Motor
50
40
Speed (mm/s)
30 LAS4-1
20 LAS4-2
10
0
0 200 400 600 800
Load (N)
LAS4-1/ -2
24 VDC Motor
4
3.5
3
Current (Amp)
2.5 LAS4-1
2
1.5 LAS4-2
1
0.5
0
0 100 200 300 400 500 600 700 800
Load (N)
**Note: The test results are obtained by using the 24VDC power supply.
LAS4-1/ -2
12 VDC Motor
6
5
4
Current (Amp)
3 LAS4-1
LAS4-2
2
1
0
0 100 200 300 400 500 600 700 800
Load (N)
**Note: The test results are obtained by using the 12VDC power supply.
Ordering Information
LAS4 - 1 - 1 - 200 - 12 G E
Model number 0 : Without internal limit switches Stroke length Voltage Color Special models according to the customer’s
1 : Basic model complete with internal limit switches B : Black requirement (Ignore this part of the serial
G : Gray number if not available)
21
Linear Actuator
LAS Series
LAS5
36
6.2+0.2
R2
-0
28
• LAS5 Ø10
Ø12
RL = S+205
Ø21.9
Ø30
Ø35
Stroke ≤ 300
RL = S+255
Ø22.2
24 18.5 121 11
Stroke > 300
RL: Retracted length RL
S: Stroke length
LAS5A
36
R2
6.2+0.2
-0
28
• LAS5A
RL = S+240
Ø10
Ø12
Stroke ≤ 300
RL = S+290
Ø21.9
Ø30
Ø43
22
Table 14.2 LAS5 Specifications
Model Thrust Pulling Holding Speed Standard stroke Duty Current max.
max. max. max. (mm / s) (mm) : S cycle (A)
(N) (N) (N) Load = Max. / Load = 0 % 24VDC
LAS5-1 800 800 600 3.5 / 4.2 100 150 200 250 300 10 1
LAS5-2 300 300 200 8.5 / 10 100 150 200 250 300 10 1
*Min. input power = Voltage x Current max.
LAS5-1/-2 LAS5-1/-2
24 VDC Motor 24 VDC Motor
10 2.5
Current (Amp)
Speed (mm/s)
8 2
6 LAS5-1 1.5 LAS5-1
4 LAS5-2 1 LAS5-2
2 0.5
0 0
0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600 700 800
Load(N) Load(N)
**Note: The test results are obtained by using the 24VDC power supply.
LAS5A-1/-2 LAS5A-1/-2
24 VDC Motor 24 VDC Motor
10 2.5
Current (Amp)
2
Speed (mm/s)
8
6 LAS5-1 1.5 LAS5-1
4 LAS5-2 1 LAS5-2
2 0.5
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 0 200 400 600 800 1000 1200 1400 1600 1800 2000
Load (N) Load(N)
**Note: The test results are obtained by using the 12VDC power supply.
Ordering Information
LAS5A - 1 - 0 - 200 - 24 G E
Model number 0 : Basic model Stroke length Voltage Color Special models according to the customer’s
1 : Complete with External limit switches B : Black requirement (Ignore this part of the serial number if
G : Gray not available)
23
Linear Actuator
LAN Series
RL
82.6 173.5
24.6 166
Ø10+0.2
-0 7.5 (25) 11
R2
6.2
33
6.2
Ø21.9
24.9
Ø26
11 Ø10+0.2
-0
28
50.8
54.8
158
170
57.8
(C) (B)
(A)
71 33.5 78 • RL = S+173
MOTOR CABLE Stroke ≤ 300
MOTOR CABLE LENGTH=1000mm RL = S+223
Stroke > 300
RL: Retracted length
S: Stroke length
Table 15.1 Specifications Table 15.2 Position feedback specifications (Optical Sensor)
Screw type ACME Supply voltage 24VDC 12VDC 5VDC
Weight* 2.6kg High level 24VDC High level 12VDC TTL
Output
Protection IP54 Low level 0.2V / 10mA sink (NPN) Low level 0.2V / 10mA sink (NPN)
Compatible with all controllers
Compatible controller (*Notice the type of connector: Audio/DIN
4pin)
Working temp. +5oC~40oC
* Stroke length 200mm
Option:
(1) IP66 (6) Mechanical quick release (RL=S+230), Only for LAN1-4
(2) Position feedback (7) Motor cable outlet: (A)Standard (B)Front (C)Back.
(3) Safety Nut (RL = S+185 , S ≤ 300 / RL = S+235 , S > 300) (8) 36VDC motor
(4) Mechanical Spline (push only) (RL = S+223 , S ≤ 300 / RL = S+273 , S > 300) (9) UL version
(5) Back fixture turned 90o (10) Plug: DIN 4PIN plug / Stereo plug / Mono plug
24
Table 15.3 Standard Motor
Model Thrust Pulling Holding Speed Standard stroke Duty Current max. Hall Sensor
max. max. max. (mm / s) (mm) : S cycle (A) Resolution
(N) (N) (N) Load = Max. / Load = 0 % 24VDC (mm/pulse)
LAN1-1 6000 5000 5000 2.7 / 5 100 150 200 250 300 10 4 0.3
LAN1-2 4000 4000 4000 5/7 100 150 200 250 300 10 4 0.5
**Note: The test results are obtained by using the 24VDC power supply and holding by motor short-circuited.
*Min. input power = Voltage x Current max.
24 VDC Motor
LAN1-1/ -2 24 VDC Motor
LAN1-1/ -2
16 4.0
Current (Amp)
Speed (mm/s)
12 3.0
8 LAN1-1 2.0 LAN1-1
4 LAN1-2 1.0 LAN1-2
0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Load (N) Load (N)
12 4
LAN1-2 3 LAN1-2
8 LAN1-3 LAN1-3
2
4 LAN1-4 1 LAN1-4
0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Load (N) Load (N)
8 9.0
6 LAN1-1 LAN1-1
4 LAN1-2 6.0 LAN1-2
2 LAN1-3 3.0 LAN1-3
0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Load (N) Load (N)
Ordering Information
LAN1 - 1 1 - 1 - 200 - 24 G E
Model Force direction 0 : Without internal limit switches Stroke length Voltage Color Special models according to the
number 1: Standard 1 : Basic model complete with 24: Standard motor B : Black customer’s requirement (Ignore
2: Suspending install, pull internal limit switches 24Q: Fast motor G : Gray this part of the serial number if not
12: 12VDC Standard available)
25
Linear Actuator
LAN Series
27
128.2
14
70.15
Ø25
Ø25.4
35.4
39.4
28
RL
Ø12+0.1 20 13
54.8
-0.05
27
29
106
28
8.1+0.3
Ø10 +0.2
0
-0
MOTOR CABLE
50.8
MOTOR CABLE LENGTH=1000mm
104
78
• RL = S+210
Stroke < 200
RL = S+260
Stroke: 200~500mm
RL: Retracted length
S: Stroke length
26
Table 16.2 LAN3 Specifications
Model Thrust Pulling Holding Speed Standard stroke Duty Current max. Potentiometer MR Sensor
max. max. max. (mm / s) (mm) : S cycle (A) Resolution Resolution
(N) (N) (N) Load = Max. / Load = 0 % 24VDC (Ohm/mm) (mm/pulse)
LAN3-1 10000 6000 10000 4.5 / 8 100 150 200 250 300 350 400 - - 10 8.3 37.5 0.16
LAN3-2 7000 6000 7000 6.5 / 9 100 150 200 250 300 350 400 450 500 10 8 28 0.22
LAN3-3 5000 5000 5000 9 / 12.5 100 150 200 250 300 350 400 450 500 10 7 22.5 0.27
* Stroke over 200mm (included), RL=S+260
* Min. input power = Voltage x Current max.
LAN3-1/ -2 / -3 LAN3-1/ -2 / -3
24 VDC Motor 24 VDC Motor
15 9
Current (Amp)
Speed (mm/s)
10 LAN3-1 6 LAN3-1
LAN3-2 LAN3-2
5 LAN3-3 3 LAN3-3
0 0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
Load (N) Load (N)
**Note: The test results are obtained by using the 24VDC power supply and holding by motor short-circuited.
LAN3-1/ -2 / -3 LAN3-1/ -2 / -3
24 VDC Motor 24 VDC Motor
20 12
10
15
Current (Amp)
Speed (mm/s)
LAN3-1 8 LAN3-1
10 LAN3-2 6 LAN3-2
5 LAN3-3 4 LAN3-3
2
0 0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
Load (N) Load (N)
**Note: The test results are obtained by using the 24VDC power supply and holding by motor short-circuited.
Ordering Information
LAN3 - 1 1 - 0 - 200 - 24 G E
Model Force direction 1: Basic model complete with Stroke Voltage Color Special models according to the customer’s
number 1: Standard internal limit switches length 24: Standard motor B : Black requirement (Ignore this part of the serial
2: Suspending install, pull 24Q: Fast motor G : Gray number if not available)
27
Linear Actuator
LAN Series
RL
116.5
0-+00.2
28
35.4
2-Ø1
15 20 28
26
29
27
8.1+0.3
25.4
-0
50.8
209.3
• RL = S+210
Stroke < 200 76
RL = S+260
Stroke: 200~500mm
RL: Retracted length
S: Stroke length
28
Table 17.2 LAN3A Specifications
Model Thrust Pulling Holding Speed Standard stroke Duty Current max. Potentiometer MR Sensor
max. max. max. (mm / s) (mm) : S cycle (A) Resolution Resolution
(N) (N) (N) Load = Max. / Load = 0 % 24VDC (Ohm/mm) (mm/pulse)
LAN3A-1 12000 6000 12000 3 / 5 100 150 200 250 300 10 8.3 56.3 0.1
LAN3A-2 10000 6000 10000 4.5 / 8 100 150 200 250 300 10 8.3 37.5 0.16
LAN3A-3 7000 6000 7000 7/9 100 150 200 250 300 10 8 28 0.22
LAN3A-4 5000 5000 5000 9.5 / 12.5 100 150 200 250 300 10 7 22.5 0.27
* Min. input power = Voltage x Current max.
LAN3A-1/-2/-3/-4 LAN3A-1/-2/-3/-4
24 VDC Motor 24 VDC Motor
14
12 9
10 LAN3A-1 LAN3A-1
Current (Amp)
Speed (mm/s)
8 LAN3A-2 6 LAN3A-2
6 LAN3A-3 LAN3A-3
4 LAN3A-4 3 LAN3A-4
2
0 0
0 2000 4000 6000 8000 10000 12000 0 2000 4000 6000 8000 10000 12000
Load (N) Load (N)
**Note: The test results are obtained by using the 24VDC power supply and holding by motor short-circuited.
LAN3A-1/-2/-3/-4 LAN3A-1/-2/-3/-4
24 VDC Motor 24 VDC Motor
18 14
15 12
Speed (mm/s)
10
Current (Amp)
12 LAN3A-1 LAN3A-1
9 LAN3A-2 8 LAN3A-2
LAN3A-3 6 LAN3A-3
6 4
LAN3A-4 LAN3A-4
3 2
0 0
0 2000 4000 6000 8000 10000 12000 0 2000 4000 6000 8000 10000 12000
Load (N) Load (N)
**Note: The test results are obtained by using the 24VDC power supply and holding by motor short-circuited.
Ordering Information
LAN3A - 1 1 - 0 - 200 - 24 G E
Model Force direction 1: Basic model complete with Stroke Voltage Color Special models according to the customer’s
number 1: Standard internal limit switches length 24: Standard motor B : Black requirement (Ignore this part of the serial
2: Suspending install, pull 24Q: Fast motor G : Gray number if not available)
29
Linear Actuator
LAN Series
RL
185
Ø10+0.2
-0
(22) 11
Ø30
R2
94
6.2
Ø21.9
24.9
18.6
22
Ø10+0.2
-0
6.1+0.2
-0
28
Ø25.9 +0-0.2 11
87 24
MOTOR CABLE
LENGTH=1000mm
• RL = S+160
Stroke ≤ 200
RL = S+210
Stroke > 400
RL: Retracted length
S: Stroke length
30
Table 18.2 LAN4 Specifications
Model Thrust Pulling Holding Speed Standard stroke Duty Current max.
max. max. max. (mm / s) (mm) : S cycle (A)
(N) (N) (N) Load = Max. / Load = 0 % 24VDC 12VDC
LAN4-1 3500 3500 3500 3.5 / 7 100 150 200 250 300 350 400 10 6 12
LAN4-2 3000 3000 3000 4.2 / 9 100 150 200 250 300 350 400 10 6 12
LAN4-3 2000 2000 2000 6 / 13 100 150 200 250 300 350 400 10 5 12
LAN4-4 1500 1500 1500 8.5 / 20 100 150 200 250 300 350 400 10 5 12
* Min. input power = Voltage x Current max.
LAN4-1/ -2 / -3 / -4
24(12) VDC Motor
25
20 LAN4-1
Speed (mm/s)
15 LAN4-2
10 LAN4-3
LAN4-4
5
0
0 500 1000 1500 2000 2500 3000 3500
Load (N)
LAN4-1/ -2 / -3 / -4
24 VDC Motor
6
5
Current(Amp)
4 LAN4-1
LAN4-2
3 LAN4-3
2 LAN4-4
1
0
0 500 1000 1500 2000 2500 3000 3500
Load (N)
**Note: The test results are obtained by using the 24VDC power supply.
LAN4-1/ -2 / -3 / -4
12 VDC Motor
12
10
Current(Amp)
8 LAN4-1
LAN4-2
6
LAN4-3
4 LAN4-4
2
0
0 500 1000 1500 2000 2500 3000 3500
Load (N)
**Note: The test results are obtained by using the 12VDC power supply.
Ordering Information
LAN4 - 1 - 0 - 300 - 24 G E
Model number 0: Basic model Stroke length Voltage Color Special models according to the customer’s requirement
*1: Over-Current protection B : Black (Ignore this part of the serial number if not available)
G : Gray
* Remark: The over-current protection is for over load protection, do not use for limit stop.
Suggestion:To add exterual limit switch as limit positions stop.
31
Linear Actuator
LAN Series
(RL)
50.8
118.6
97.8 33 116.1 58.1
36 Ø10.1+0.2
-0 22.1
Ø10.1+0.2
-0 18 45
(28)
35.4
43 31.5
Ø30
30
35±0.1
8.2 +0.2
• RL = S+163
-0
(25.6)
165.5
8.2+0.2
Stroke ≤ 300
-0
RL = S+213
Stroke > 300 MOTOR CABLE
RL: Retracted length 72.6 LEGTH=1000mm Ø78
S: Stroke length
QUICK RELEASE (RL)
50.8
35.4
-0
165.5
(25.6)
8.2+0.2
Table 191 Specifications Table 19.2 Position feedback specifications (Hall Sensor)
Screw type ACME Supply voltage 24VDC 12VDC 5VDC
Weight* 1.96kg High level 24VDC High level 12VDC TTL
Output
Protection IP54 Low level 0.2V / 10mA sink (NPN) Low level 0.2V / 10mA sink (NPN)
Compatible with all kinds of controller
Compatible controller
(*Notice the type of connector: Audio/DIN 4PIN)
Working temp. +5oC~40oC
* Stroke length 200mm
Option:
(1) Hall Sensor (4) Back fixture turned 0°, 45°, 90°, 135° (7) Quick release (For LAN5-3, LAN5-4 only)
(2) Safety nut (5) IP65; IP66 (8) UL version
(3) Mechanical Spline (push only) (6) Back fixture and rodeye hole Ø12.1mm (9) Plug: DIN 4PIN plug / Stereo plug / Mono plug
32
Table 19.3 LAN5 Specifications
Model Thrust Pulling Holding Speed Standard stroke Duty Current max. Hall Sensor
max. max. max. (mm / s) (mm) : S cycle (A) Resolution
(N) (N) (N) Load = Max. / Load = 0 % 24VDC (mm/pulse)
LAN5-1 8000 4000 6000 2 / 3.5 100 150 200 250 300 10 5 0.08
LAN5-2 6000 4000 5000 3 / 4.5 100 150 200 250 300 10 4.5 0.10
LAN5-3 4000 3000 4000 4 / 5.5 100 150 200 250 300 10 4 0.14
LAN5-4 3000 2000 1500 6/9 100 150 200 250 300 10 4 0.22
* When the stroke of LAN5-1 is between 250mm and 300mm, refer to the diagram on the right for max. load. * LAN5-3 24V Quick release Holding max. 3000N
* LAN5-4 24V Quick release Holding max. 1000N * Min. input power = Voltage x Current max.
LAN5-1/ -2 / -3 / -4 LAN5-1/ -2 / -3 / -4
5.0 10
4.0 LAN5-1 8 LAN5-1
Current (Amp)
Speed (mm/s)
3.0 LAN5-2 6 LAN5-2
2.0 LAN5-3 4 LAN5-3
1.0 LAN5-4 2 LAN5-4
0 0
0 1000 2000 3000 4000 5000 6000 7000 8000 0 1000 2000 3000 4000 5000 6000 7000 8000
Load (N) Load (N)
LAN5-1 (24)
8000
Load (N) 7000
6000 LAN5-1-250
5000 LAN5-1-300
4000
**Note: The test results are obtained by using the 24VDC power supply. 0
0 100 150 200 250 300 350 400 450
S (mm)
LAN5-1/ -2 / -3 / -4 LAN5-1/ -2 / -3 / -4
8.5 20
7.5
Current (Amp)
5.5 12
4.5 LAN5-2 LAN5-2
3.5 LAN5-3 8 LAN5-3
2.5
1.5 LAN5-4 4 LAN5-4
0.5
0 0
0 1000 2000 3000 4000 5000 6000 7000 8000 0 1000 2000 3000 4000 5000 6000 7000 8000
Load (N) Load (N)
LAN5-1(24Q)
8000
7000
Load (N)
6000 LAN5-1-250
5000 LAN5-1-300
4000
0
0 100 150 200 250 300 350 400 450
S (mm)
Ordering Information
LAN5 - 1 1 - 1 - 200 - 24 G E
Model Thrust 1: Basic model complete with Stroke length Voltage Color Special models according to the customer’s
number 1: Standard internal limit switches 24: Standard motor B : Black requirement (Ignore this part of the serial
2: Suspending install, pull 24Q: Fast motor G : Gray number if not available) 33
Linear Actuator
LAC Series
4 - M8x1.25Px14DP
Ø110
113
90
35
35
RL
75.3
MOTOR CABLE
0° 6 - M6x1Px12DP
6-6 MOTOR CABLE LENGTH=1000mm
• RL = 150+S/2
Ø80
34
Table 20.2 LAC1 Specifications
Model Thrust Pulling Holding Speed Standard stroke Duty Current max. Potentiometer Hall Sensor
max. max. max. (mm / s) (mm) : S cycle (A) Resolution Resolution
(N) (N) (N) Load = Max. / Load = 0 % 24VDC (ohm/mm) (mm/pulse)
LAC1-1 2000 500 2000 8 / 12 300 400 500 10 5 6.67 1.0
* Min. input power = Voltage x Current max.
LAC1 LAC1
14 5
12
10 4
Speed (mm/s)
Current (Amp)
8 3
6 2
4
2 1
0 0
0 500 1000 1500 2000 0 500 1000 1500 2000
Load (N) Load (N)
**Note: The test results are obtained by using the 24VDC power supply.
10 Left Right
8
6
4 Load
2
0
0 500 1000 1500 2000
Load (N) Bending moment Bending moment
Dynamic:max. 350Nm Dynamic:max. 350Nm
Static:max. 500Nm Static:max. 500Nm
LAC1
24Q VDC Motor
8
7
6
Current (Amp)
5
4
3
2
1
0
0 500 1000 1500 2000
Load (N)
Ordering Information
LAC1 - 1 - 1 - 400 - 24 G E
Model number 1: Basic model complete with Stroke length Voltage Color Special models according to the customer’s requirement
internal limit switches G : Gray (Ignore this part of the serial number if not available)
35
Linear Actuator
LAC Series
Ø49.5
138.4
35
35 4-M8x1.25Px14DP
RL
MOTOR CABLE
MOTOR CABLE LENGTH=1000mm
77
°
6-60 6-M6x1Px12DP
• RL = 171+S/2
RL: Retracted length
0
Ø8
36
Table 21.2 LAC3 Specifications
Model Thrust Pulling Holding Speed Standard stroke Duty Current max. Potentiometer Hall Sensor
max. max. max. (mm / s) (mm) : S cycle (A) Resolution Resolution
(N) (N) (N) Load = Max. / Load = 0 % 24VDC (ohm/mm) (mm/pulse)
LAC3-1 2000 500 2000 8 / 12 300 400 500 10 5 6.67 1.0
* Min. input power = Voltage x Current max.
LAC3
24 VDC Motor
14
12
10
Speed (mm/s)
8
6
4
2
0
0 500 1000 1500 2000
Load (N)
LAC3
24 VDC Motor
5
4
Current (Amp)
3
2
1
0
0 500 1000 1500 2000
Load (N)
**Note: The test results are obtained by using the 24VDC power supply.
Ordering Information
LAC3 - 1 - 1 - 400 - 24 G E
Model number 1: Basic model complete with Stroke length Voltage Color Special models according to the customer’s requirement
internal limit switches G : Gray (Ignore this part of the serial number if not available)
37
Linear Actuator
1-Axis Controller
180
167
68
92
4-Ø5.5
159.5
173
AC In Keypad Motor
67.5
1 2
8
• RL = 171+S/2
RL: Retracted length
S: Stroke length
38
For Series LAM completed with external limit switches
Power
LAP2-1
Ordering Information
LAK2LR - G - 110 - B E
Actuator No. 1 Input Voltage Color Special models according to Client’s requirement
G: Over current setting value 100: AC100V; 110: AC110V B: Black None
220: AC220V; 230: AC230V G: Gray E = Special requirement
* Check attached table for over current setting...see page 55.
* The keypad of the LAK2LR is not the same as LAK2L.
39
Linear Actuator
2-Axis Controller
68
92
4-Ø5.5
159.5
173
AC In Keypad Motor
67.5
1 2
Power
HIWIN
LAP2-2
40
Ordering Information (AC Power)
LAK2 - B0 - 110 - B E
Actuator No. 1~2 Input Voltage Color Special models according to Client’s requirement
A~G: Over current setting value 100: AC100V; 110: AC110V B: Black None
220: AC220V; 230: AC230V G: Gray E = Special requirement
* Check attached table for over current setting...see page 55.
Actuator No. 1~2 Input Voltage Color Special models according to Client’s requirement
A~L: Over current setting value 12: 12VDC B: Black None
24: 24VDC G: Gray E = Special requirement
* Standard cable: 1M in length with 3 flying lead termination.
* Check attached table for over current setting...see page 55.
41
Linear Actuator
2-Axis Controller
0 No Battery box 245
24. HIWIN 2-Axis Controller (2) 230
LAK2BN
107
91
4-Ø4.5
66
100
AC in
6.5
DC in KP 1 2
107
91
123
91
107
4-Ø4.5
173 Ø4.5
173
220 220
66 10
66
37
100
10
137
6.5
46
100
AC In DC in KP 1 2
6.5
46
AC In DC in KP 1 2
Table 24.1 Specifications Option: Current vs. Durable Period under Load (1.3Ah)
Input voltage AC 100 / 110 / 220 / 230V
(1) IP66 75 70
Output power 144VA (24VDC) max (2) Custom program 70
65 60
Duty cycle 10% (3) Two axes move simultaneously 60
55 48
Protection IP54 (4) Two axes move synchronously 50
Time (min)
42
Ordering Information
LAK2BN - 1 - D0 - 110 - B E
Battery Actuator No. 1~2 Input Voltage Color Special models according to Client’s requirement
0: None Battery box 0: None 100: AC100V; 110: AC110V B: Black None
1: 1.3Ah A~H: Over current setting value 220: AC220V; 230: AC230V G: Gray E = Special requirement
2: 2.9Ah
* Check attached table for over current setting...see page 55.
43
Linear Actuator
2-Axis Controller
R2
R2
2
27.8
8
76
AC In
1
Ø4.
2
KP
15
10
3.3
7.3 117.8 16.3 5.08
4.7
44
LAK2D can be mounted with LAM3 or LAN5
Power
HIWIN
LAP1-2
Ordering Information
LAK2D - 1 - D0 - 110 - G E
Battery Actuator No. 1~2 Input Voltage Color Special models according to Client’s requirement
0: None 0: None 100: AC100V; 110: AC110V B: Black None
1: 9-volt alkaine battery A~F: Over current setting value 220: AC220V; 230: AC230V G: Gray E = Special requirement
* Check attached table for over current setting...see page 55.
* LAK2D over current must be set to the same value.
45
Linear Actuator
2-Axis Controller
68
24
426.9
402
408.5
BATTERY
2
STOP
OC
1
EMERGENCY
KP 1 2
125
112.5
88
46
Features of the LAK2J Battery Characteristics
Battery Capacity and voltage VS. Number of cycles
- Portable design (operated by battery)
- Control 1 to 2 Linear Actuators 100% 27
95%
- Emergency stop button 90%
26.5
Note: 1.The test results are obtained under duty cycle 10%
(2 minutes of continuous operation followed by 18 minutes of non-operation).
2.The Test results are for reference only, actual value will be different due to the
battery performance.
Power
LAP3-1
BATTERY
LAK2J-11
*Charger: DC-Input
EMERGENCY
L HOU TA
AL-301
HT
N
E
KP 1 2
DC24V
LAKCH-A
Power
LAP3-1
BATTERY
STOP
EMERGENCY
KP 1 2
LAK2J-12
*Charger: AC-Input
Ordering Information
LAK2J - 1 1 - HH - 01 - 24 - W - E
Battery Charger Actuator No.1~2 Software function Output power Color Special models according to
1: 4.5Ah 1: DC in charger by LAKCH-A 0: None 01: Standard DC: 24V W: White Client’s equirement
2: AC in charger A~H: Over current setting value G: Gray None
(100~230VAC, 50~60HZ) E = Special requirement
47
Charger/Battery
LENGTH=1.4M
(401.6)
115.2
BATTERY
CHARGER
Input Voltage:
AC 100 - 230V
(50/60HZ)
Output Voltage:
DC 27V - 1A
Charge
37.8 LENGTH=1.7M
KP 1
36
Cable length=4M
Color: Black
62.3
AC IN
(90.5)
(125)
Ordering Information
LAKCH - A - 24 - B
LAKCH - B - 24 - W E
Wall charger Output power Color Special models according to Client’s requirement
DC: 24V W: White None
G: Gray E=Special requirement
48
Linear Actuator
3-Axis Controller
145
3-R
8
152
200
66.5
15.5
11.5
3-Ø5
AC In Keypad Motor1 2 3 4
35
89
10
161
49
LAK4 can be mounted with LAN1
Power
HIWIN
LAP 414
Ordering Information
LAK4 - D000 - 110 - B E
Actuator No.1~3 Input Voltage Color Special models according to Client’s requirement
0: None 100: AC100V; 110: AC110V B: Black None
A~F: Only indicate the actuator maximum current, 220: AC220V; 230: AC230V G: Gray E = Special requirement
not indicate over current setting value.
50
Linear Actuator
4-Axis Controller
29
16.1
189.9
35.2 46.9 25.3
22.2 2.7
Axis 4
Axis 3
155.5
140.9
Axis 2
Axis 1
Keypad
Features of LAK4D
- Control 1 to 4 Linear Actuator - LED power display.
- Standard cable length: 4M - Can be mounted directly on the LAN5.
- Detachable cable retainer (protection against accidental unplugging) (LAN5 min. RL must be greater than 300mm)
- Removable AC power cable. * Notes: LAK4D without over current protection.
51
LAK4D can be mounted with LAN5
Power
LAP4G-4
Ordering Information
LAK4D - D000 - 110 - G E
Actuator No.1~4 Input Voltage Color Special models according to Client’s requirement
0: None 100: AC100V; 110: AC110V B: Black None
A~H: Only indicate the actuator maximum current, 220: AC220V; 230: AC230V G: Gray E = Special requirement
not indicate over current setting value. 120: AC 120V
52
Linear Actuator
6-Axis Controller
327.3
306
5.5
7.3
8
Ø9
85
113.8
130.9
327.3
92.5
92
53
Features of LAK6B
- Control 1 to 6 Linear Actuators - Rechargeable battery - Main fuse replaceable by external plug
- Over load protection - Low battery indicator (alarm) - Spare fuse inside the fuse plug
- Soft-start - Automatic energy saving - External ground connection
- Standard cable length: 4M - Battery capacity 1.3Ah (12VDCx2) - LED power indication
* Note: Simultaneous movement is not available for LAN3-1/-2/-3(24Q)
* Note: Please charge battery for at least 8 hours before initial use.
75 70
Power
70
LAP5-5
65 60
60
55 48
50
Time (min)
45 39
40
35 28
30
AC IN FUSE 6 5 4 3 2 1 A B
25 17
20 12
15
10 8
5
0
1.5 2 2.5 3 3.5 4 5 6
Current (A)
Note: 1.The test results are obtained under duty cycle 10%
(2 minutes of continuous operation followed by 18 minutes of non-
operation).
2.The Test results are for reference only, actual value will be different
due to the battery performance.
Ordering Information
LAK6B - 1 - D 00000 - 00 - 110 - G - E
Battery Actuator No.1~6 Type Input Voltage Color Special models according to Client’s requirement
0: No 0: None 00: Standard 100: AC100V; 110: AC110V W: White None
1: 1.3Ah A~J: Over current setting value 01: Custom software 220: AC220V; 230: AC230V G: Gray E = Special requirement
* Check attached table for over current setting...see page 55.
54
Over Current Setting Table
Code No. Current setting Actuator Model Controller Model
A 2.5A LAS4-1; LAS5-1/-2 LAK2; LAK2D; LAK2LR; LAK2BN; LAK2J; LAK4; LAK4D; LAK6B
B 3.0A LAS1-1; LAS3-1; LAI2-1; LAS5A-1/-2 LAK2; LAK2D; LAK2LR; LAK2BN; LAK2J; LAK4; LAK4D; LAK6B
C 4.0A LAS1-2; LAS3-2; LAS4-2; LAI1-1(24V); LAM2-3/-4; LAS2-1/-2; LAI2-1 LAK2; LAK2LR; LAK2D; LAK2BN; LAK4; LAK6B
D 5.0A LAM3-3/-4; LAN1-1/-2; LAN5-2/-3/-4; LAM2-1/-2; LAI2-2 LAK2; LAK2D; LAK2LR; LAK2BN; LAK2J; LAK4; LAK4D; LAK6B
E(24V) 6.0A LAM3-2; LAN4; LAC3-1; LAN4-3/-4; LAN5-1; LAI1-1A(24V); LAC1 LAK2D; LAK2BN; LAK2J; LAK4; LAK4D; LAK6B
E(12V) 6.0A LAS1-1(12V); LAS3-1(12V); LAS4-1(12V); LAM2-3/-4; LAS2-1/-2 LAK2(DC)
F(24V) 7.0A LAN1-1/-2/-3/-4(24Q); LAM3-1; LAN4-1/-2; LAN5-3/-4(24Q) LAK2; LAK2D; LAK2LR; LAK2BN; LAK2J; LAK4; LAK4D; LAK6B
F(12V) 7.0A LAS1-2(12V); LAS3-2(12V); LAS4-2(12V); LAM2-3/-4 LAK2(DC)
G(24V) 8.0A LAM1-1/-2/-1A; LAN5-1/-2(24Q) LAK2; LAK2LR; LAK6B
G(12V) 8.0A LAI1-1(12V); LAM-1/-2 LAK2(DC)
H(24V) 9.0A LAN3-1/-2/-3(24V); LAN3A-1/-2/-3/-4(24V) LAK6B
H(12V) 9.0A LAI1-1A(12V); LAM2-1/-2 LAK2(DC)
I 10A For reservation
J 12A LAN3-1/-2/-3(24Q); LAN3A-1/-2/-3/-4(24Q) LAK6B
K 14A For reservation
L 15A LAN1-1/-2/-3(12V); LAM1-1/-2/-1A(12V), -2A(12V); LAM3(12V); LAN4(12V) LAK2(DC)
Z **A Special current value (special requirement)
55
Linear Actuator
Battery
Cable
Length=120mm
(265)
60.6
Battery: LAKB-2
BATTERY
156.5
155 (125)
123
(87)
(150)
Cable
Length=120mm
97.6
Ordering Information
LAKB - 1 - G E
LAKB - 3 - G E
56
Linear Actuator
Over Current Protection Box
89.8
Black(+) Male 5 50
White(-)
8
9
R4
Black
36.5
81.1 56.3
35.3
8.7
57
For Series
* When purchasing an actuator to be connected with the LAKC, please inform the Hiwin sales representative.
Ordering Information
LAKC1 - 1 - 12 - 6 G E
Model number Input (Output) Voltage Over Current Setting Color Special models according to Client’s requirement
12: 12VDC 12V: 24V: B : Black None
24: 24VDC 2: 2A 2: 2A G: Gray E=Ignore this part of the serial number if not available
3: 3A 2.5: 2.5A
4: 4A 3: 3A
5: 5A 4: 4A
6: 6A 5: 5A
8: 8A 6: 6A
10: 10A 7: 7A
12: 12A 8: 8A
18: 18A 9: 9A
10: 10A
58
Linear Actuator
Keypad Series
Power
HIWIN
LAP1-2
134
54.1
167
Ø15
33
23
LAP2
52.2
39.7 20
Power
44.1
HIWIN
LAP212
R7.5
25.3
164.9
76.6
25
Ø15
59
53
LAP3
20 55
Power
134
54.1
167
Ø15
23
LAP3N
53
20 55
Power
134
54.1
167
Ø15
23
60
LAP4 53
50 20 50
179
212
Ø15
26
LAP4G 58.2
65 21.8
170
179.5
212.5
LAP4G-4
Ø15
33
61
LAP4N 53
50 20 50
179
212
Ø15
26
53
LAP4R 50
20 50
179
212
Ø15
26
62
LAP4M 50
20
53
50
179
HIWIN
212
LAP4M
Ø15
26
LAP5
53
50 50
20
Power
HIWIN
179
212
LAP5-5
Ø15
26
Ordering Information
LAP1 - 2 - B E
63
LAPM
(L) 120±0.2
10
4-R
70±0.2
0.6±0.1
Right Side
Ordering Information
LAPM1 - 1 - R E
64
LACP2
65.5 185
(33.5) 29.4
(29.5)
125
143
S CPR
(172.2)
- +
STOP
LACP2
23.5
2-Copper Nut
M5x12mm
Ordering Information
LACP2 - 2 - B E
Model number Number of axis controlled Color Special models according to Client’s requirement
B : Black None
G : Gray E = lgnore this part of the serial number if not available
65
LAFS1
25
125
157 37
Ordering Information
LAFS1 - 1 - G E
Model number Number of axis controlled Color Special models according to Client’s requirement
LAFS1 G: Gray None
E = lgnore this part of the serial number if not available
66
Linear Actuator
Options for each type
1 LAM
2 LAM2
3 LAM3 200mm (L)
4 LAI
5 LAI2
(Bare Wire)
6 LAS
7 LAS2
8 LAS3 (L)
9 LAS4
1M 1.5M 2M 2.5M 3M
10 LAS5
(DIN 4 PIN Connector)
11 LAN1 300mm
12 LAH1 300mm
13 LAN3
(L)
14 LAN3A
15 LAN4
16 LAN5 410mm
(Audio Connector)
17 LAC1
18 LAC3
19 LAN5 Coil
DIN 4PIN - Coil Species 1 2 3 4 5
Length A 100 300 300 100 1350
Length B 100 300 400 600 400
Length C 130 130 330 130 110
A B C 130 +50
5
A B C 130 +50
5
DIN 4PIN - Coil Species 1 2
(90° Connector) Length A 100 300
Length B 100 300 A B C 26
Length C 100 100
A B C 26
67
Y-CABLE
600
250
17.5
250
Plug
Plug Socket
500
7
6
5
1
Socket
1
2
8 2
4 3 7
8 6
4 5
800
Plug
7 Plug
6
1
5
2
8
4 3
Socket
500
Socket
1
2
7
8 6
4 5
Ordering Information
LAPY - 1 - G E
Model of Y extension cable Cable Color Special models according to Client’s requirement
1: Coil cable B: Black None
2: Straight cable G: Gray E = lgnore this part of the serial number if not available
68
34. HIWIN LAP4G Mask Options
69
LAP4G Mask (3)
Power Power Power Power Power Power
M1 M2
M3 CPR
LAP4G-3 LAP4G-4 LAP4G-5
70
35. HIWIN Options for each Actuator Type
Function IP54 IP65 IP66 Back Gear Rod end Safety Spline Quick Internal External Hall Sensor Potentiometer Optical Sensor MR
fixture box with flat nut (push release limit limit Sensor
turn 90° material connector only) switches switches NPN TTL NPN PNP TTL NPN
Series S45C
LAM1 LAM1-1
LAM1-2
LAM1-1A
LAM1-2A
LAM2 LAM2-1
LAM2-2
LAM2-3
LAM2-4
LAM3 LAM3-1
LAM3-2
LAM3-3
LAM3-4
LAS1 LAS1-1
LAS1-2
LAS2 LAS2-1
LAS2-2
LAS3 LAS3-1
LAS3-2
LAS4 LAS4-1
LAS4-2
LAS5 LAS5-1
LAS5-2
LAN1 LAN1-1
LAN1-2
LAN1-3
LAN1-4
LAN3 LAN3-1
LAN3-2
LAN3-3
LAN3A LAN3A-1
LAN3A-2
LAN3A-3
LAN3A-4
LAN4 LAN4-1
LAN4-2
LAN4-3
LAN4-4
LAN5 LAN5-1
LAN5-2
LAN5-3
LAN5-4
LAC1 LAC1-1
LAC3 LAC3-1
” ” Standard
” ” Option is available.
” ” ” ” Only 1 option is available.
71
Linear Actuator
Introduction
Type
IP54
IP65
IP66
Input Voltage DC 12V
DC 24V
AC 100V
AC 110V
AC 120V
AC 220V
AC 230V
Output Power 72.5VA
(24V) 108VA
144VA
216VA
Max. control axis no. 1 2 2 2 2 3 4 6
Over load protection
Relay protection
Battery 9V alkaline
1.3Ah
(Lead Acid )
2.9Ah
(Lead Acid )
4.5Ah
(Lead Acid )
Charge function
Energy saving
Custom program
Control external
limit switch
Mounted with
actuator
Detachable cable
retainer
Removable AC
power cable
” ” Standard
” ” Option is available.
” ” ” ” Only 1 option is available.
72
Customer Requirements (LA)
Engineer: Manager:
FME014-02
73
HIWIN USA HIWIN GmbH HIWIN FRANCE
•CHICAGO Brücklesbünd 2, D-77654 24 ZI N 1 EST-BP 78
1400 Madeline Lane Offenburg, GERMANY F-61302 L’Aigle Cedex
Elgin, IL 60124, U.S.A. Tel : +49-781-93278-0 Tel: +33(0)233341115
Tel : +1-847-8272270 Fax: +49-781-93278-90 Fax: +33(0)233347379
Fax: +1-847-8272291 www.hiwin.de www.hiwin.fr
www.hiwin.com www.hiwin.eu info@hiwin.fr
info@hiwin.com info@hiwin.de
•SILICON VALLEY Mega-Fabs Motion Systems, Ltd.
Tel : +1-510-4380871 HIWIN SCHWEIZ 13 Hayetzira St. Industrial Park, P.O.Box
Fax: +1-510-4380873 Schachenstrasse 80 540, Yokneam 20692, Israel
HIWIN MIKROSYSTEM CORP. CH-8645 Jona, Tel: +972-4-9891050
No.6, Jingke Central Rd., Precision HIWIN JAPAN SWITZERLAND Fax: +972-4-9891080
Machinery Park, Taichung 40852, Taiwan •KOBE Tel : +41-55-2250025 www.mega-fabs.com
Tel : +886-4-23550110 3F. Sannomiya-Chuo Bldg. Fax: +41-55-2250020 info@mega-fabs.com
Fax: +886-4-23550123 4-2-20 Goko-Dori. Chuo-Ku www.hiwin.ch
www.hiwinmikro.com.tw KOBE 651-0087, JAPAN info@hiwin.ch Matrix Machine Tool
business@mail.hiwinmikro.com.tw Tel: +81-78-2625413 (COVENTRY) LIMITED
Fax: +81-78-2625686 HIWIN S.R.O. A2 Earlplace Business Park
www.hiwin.co.jp Kastanova 34 Fletchamstead Highway
info@hiwin.co.jp CZ 62000 Brno, Coventry CV4 9XL
CZECH REPUBLIC United Kingdom
Tel : +420-548-528238 Tel: +44(0)2476718886
Fax: +420-548-220233 Fax: +44(0)2476678899
www.hiwin.cz www.matrix-machine.com
info@hiwin.cz sales@matrix-machine.com