Beruflich Dokumente
Kultur Dokumente
Technical Information
REWOQUAT® CQ 100
Evonik Nutrition & Care GmbH | REWOQUAT® CQ 100 | July 2015 Page
1/4
Storage stability Multi Purpose Fat Solve
Packaging Preparation
200 kg drum Dissolve TKPP in water and blend REWOQUAT®
1 000 kg container CQ 100 while stirring.
Hazardous goods classification Application
Information concerning Ready-to-use dilution: 1-3%.
classification and labelling according to
regulations for transport and for dangerous
Canvas cleaner, antistatic
substances
protective measures for storage and handling Water 87.5%
measures in case of accidents and fires
Sodium gluconate 3.0%
toxicity and ecological effects
Potassium Tripolyphosphate, 50% 3.0%
is given in our material safety data sheets.
REWOQUAT® CQ 100 6.0%
Preparation
Rim cleaner
Dissolve metasilicate in water and blend IDS and
REWOQUAT® CQ 100 while stirring. Water 87.0%
Preparation
Application
Evonik Nutrition & Care GmbH | REWOQUAT® CQ 100 | July 2015 Page
2/4
Bug remover
High pH Low pH
EDTA 8.0%
Manufacturing
Dissolve all ingredients in water, then add surfactant.
Application
High pH Low pH
Manufacturing
Dissolve all ingredients in water, then add surfactant.
Application
Evonik Nutrition & Care GmbH | REWOQUAT® CQ 100 | July 2015 Page
3/4
Phosphate-Free Bug Remover (Highly dilutable*, Descaler, highly active
Premium Formula)
Water 75.0%
Water 90.0% Phosphoric acid, 85% 20.0%
EDTA or NTA 1.5% REWOQUAT® CQ 100 5.0%
Legal References
This information and all further technical advice is based on our present knowledge and experience. However, it implies no liability or
other legal responsibility on our part, including with regard to existing third party intellectual property rights, especially patent rights.
In particular, no warranty, whether express or implied, or guarantee of product properties in the legal sense is intended or implied. We
reserve the right to make any changes according to technological progress or further developments. The customer is not released from
the obligation to conduct careful inspection and testing of incoming goods. Performance of the product described herein should be
verified by testing, which should be carried out only by qualified experts in the sole responsibility of a customer. Reference to trade
names used by other companies is neither a recommendation, nor does it imply that similar products could not be used.
December 2011
Evonik Corporation
7801 Whitepine Road, Richmond VA 23237-2210, USA
Phone +1 804 4525608 Fax +1 804 5848689
info-household-care@evonik.com, www.evonik.com/household-care