in Figure 2.
To reduce network costs,
Coupler Decoupler
the Select OADM can be RBF
installed initially as a
terminal and upgraded
to a full OADM as traffic Figure 2. Non-blocking architecture for
high-capacity add/drop sites
W A S D P Data Sheet
Technical Information
System Level
Capacity ........................................................................................Full add/drop capability
Cascading ....................................................................................Multiple OADM
Add/Drop Capability....................................................................Remotely in-service configurable with single channel add/drop granularity at
50 GHz spacing Channel Spacing 25 GHz compatible
System Configuration ..................................................................Ultra long-haul and ultra high density
Link Parameters
System BER ..................................................................................< 10E-15
Network Management
EMS ..............................................................................................Supported by Ciena ON-Center Network and Service Management Suite
Simultaneous network management from a single ON-Center terminal
Craft Interface ..............................................................................VT100 style text interfaces via RS-232 async or ethernet and remote
login via telnet
Protocol/Interfaces ......................................................................ITU TMN (q.3 information model) TL-1, SNMP
Channel Performance Monitoring ............................................B1 monitoring in SONET/SDH overhead
Remote Interfaces ........................................................................RS-422/X.25 (TL-1 interface)
IP/802.3 via 10BaseT or 10Base2, OSI/LLC1/802.3 via 10BaseT or 10Base2
Optical Service Channel ............................................................2.048 Mb/s at 1625 nm
External Alarm Management ......................................................32 alarm inputs
16 control outputs (FORM-C)
Voice Orderwire ............................................................................Digital and analog capability, 2 x 64 Kb/s channels, 2 wire or 4 wire interface
Power Requirements
Power Input (shelf)........................................................................-40V to -58V DC
Power Consumption ....................................................................450 W (typical)
Agency Approvals
EMI/EMC ......................................................................................Compliant with Telcordia® GR 1089, FCC Part 15, Class A,
ETSI EN50082-1, EN61000-4
Environmental Characteristics
Operating Temperature, Relative Humidity ..............................Compliant with Telcordia NEBS (GR63), ETSI ETS 300-019-1
Vibration, Shock, and Flammability
Physical Characteristics
Shelf Dimensions (channel) ........................................................21" (H) x 23.5" (W) x 12" (D)
533 mm (H) x 597 mm (W) x 305 mm (D)
Rack Dimensions ..........................................................................84" (H) x 24" (W) x 12" (D) U.S. telco rack
89" (H) x 24" (W) x 24" (D) ETSI telco rack
2261 mm (H) x 610 mm (W) x 610 mm (D) ETSI
Ciena may from time to time make changes to the products or specifications contained herein without notice. Telcordia is a registered trademark of Telcordia Technologies, Inc.
© 2008 Ciena Corporation. All rights reserved. DS027 4.2008