TEST SCHEDULE
Antenna Height
from Ground
(Mtrs)
Part B:-
1. Maximum Trans power at antenna port 23dBm for 15 GHz and 26dBm for 18 GHz
Actual maximum Trans power at antenna port :
-To be tested in VT
Settable range of Tx power :
- The Test has been completed in VT. The result of VT Report is as under-
Setting verified at LCT
Minimum settable Power:15 GHz -5dBm, 18 GHz -6dBm
Maximum settable Power:15 GHz +25dBm, 18 GHz +24dBm
- This test may not be carried in field during AT.
2. Transmitter limits for spurious & harmonic emissions at Antennae port : <25 microwatt.
- The Test has been completed in VT. The result of VT Report is as under-
- As the test is equipment specific. This test may not be carried in field during AT.
3. Minimum distance between indoor & outdoor unit that the equipment should be able to
support: 120 m or more.
Actual distance : (between indoor & outdoor unit)
3 & -6
5. Threshold at Antenna Port for BER of (i) 1x10 - (ii) 1x10 :
TD/CFA/TS-MW/GSM Ph- VII/30 Page 2 of 6 Issue I
Dated 25/10/2013
INSPECTION CIRCLE GSM PHASE VII
JABALPUR MW LINK TS AMENDMENT-I
- The Test has been completed in VT. The result of VT Report is as under-
15 GHz---- -87.5dBm & -87.0dBm
18 GHz---- -87.2dBm & -86.7dBm
- As the test is equipment specific. This test may not be carried in field during AT.
6. System performance value (Minimum):
Procedure:- Change Trans Power from 0 dbm to 23 dbm and check from LCT : the Tx Power ,Rx
Power and BER for each step.
Received Power should be -75 dBm or better and BER should be 1x10-10 or better for data
transmission at 16x2Mbps.
7. BER Performance:
-10
Better than 1x10 level for 5 minutes of duration.
OK/Not OK
(i.e. Route failure, Equipment failure, Power supply o/p failure, Transmit power low, quality
deterioration, sync failure, No data input, status of protection switching, EI status, IDU/ODU
status)
Check local on-line monitoring through LCT/Laptop regarding health of the system
OK/Not OK
(i.e. transmit power, Receive RF level, System BER performance, Equipment power
supply, System alarm, E1 utilization status, RF channel working status, software version &
Change-over of TX/RX path etc)
Test Results
Web LCT
Transmitter Power dbm dbm
Receiver input level dbm dbm
Transmitter Frequency MHz MHz
RX Frequency MHz MHz
Redundancy Check/Alarm simulation for IDU & ODU (only for 1 + 1) Y/N
Omni/Selective OK
Not OK
THROUGH TEST
1. 4 Port:
E1-1 Ok/Not OK
E1-2 Ok/Not OK
E1-3 Ok/Not OK
E1-4 Ok/Not OK
2. 16 Port:
E1-1 Ok/Not OK
E1-2 Ok/Not OK
E1-3 Ok/Not OK
E1-4 Ok/Not OK
E1-5 Ok/Not OK
E1-- Ok/Not OK
E1-16 Ok/Not OK
9-Check for remote supervisory & telecommand facilities through LCT/NMS or any other
Suitable mechanism. OK/Not OK
Date of commissioning
Annexure-I