Sie sind auf Seite 1von 1

1 2 3 4 5 6 7 8 9 10

A A

Column Column - 1 Column C-2

FFL FFL FFL

6"

6"

6"
PB PB
9"
A
4-T12+ 4-T12
NGL NGL
B 1
RINGS
6
OR UPTO HARD STRATA

OR UPTO HARD STRATA

15"
2
T8 @ 200c/c
MIN. DEPTH 4'-6"

MIN. DEPTH 4'-6"


TOP
Reinforcement Bothways
TOP
Reinforcement Bothways
2 SETS
B B

BOTTOM BOTTOM
Reinforcement Bothways Reinforcement Bothways

Ld 1'-6" Ld 1'-6"
D

D
3" 3"
9"
A
6"

6"
PCC PCC
SECTION SECTION 4-T16+ 2-T12
B
Reinforcement
B
Reinforcement
B 1
2
Bothways Bothways

15"
2
RINGS
T8 @ 200c/c
C
2 SETS C
L

L
A
9"

1
PLAN PLAN 2 8-T16+ 2-T12

18"
RINGS
TYPICAL COLUMN FOOTING DETAILS
TYPICAL COMBINED FOOTING DETAILS
B
T8 @ 200c/c
6
D 2 SETS D

FOOTING DETAILS A
9"

COMBINED FOOTING DETAILS 1


REINFORCEMENT REINFORCEMENT 2 4-T20+ 6-T16
FOOTING L B D FOOTING L B D
BOTHWAYS

18"
X Direction Y Direction RINGS
F1 4'0" 4'0" 24" T12 @ 5" c/c CF 9' 4' 30" T12 @ 4" c/c T12 @ 4" c/c
B
T8 @ 200c/c
3
2 SETS
E
F2 5'0" 4'0" 30" T12 @ 5" c/c E

F3 5'0" 5'0" 30" T12 @ 5" c/c


F4 6'0" 6'0" T12 @ 4" c/c A
9"

30"
1 8-T20+ 2-T16
2

18"
RINGS
B
T8 @ 200c/c
1
F
2 SETS F

FOOTING REINFORCEMENT COLUMN REINFORCEMENT


GENERAL NOTES : IMPORTANT NOTES : SCHEDULE OF REVISION SCALE : NTS NAME OF THE PROJECT : PROPOSED RESIDENTIAL BUILDING @ JUDGE COURT
G G

1) ALL DIMENSIONS ARE IN FEETS AND INCHES. 1) THIS DRAWING IS UNDER THE COPY-RIGHT OF STRUCTURAL ENGINEER. DWG NO. : 02
2) ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. REVISION DATE REMARKS
:
TITLE OF THE DRAWING : FOOTING & COLUMN REINFORCEMENT DETAIL
3) CLEAR COVER TO MAIN STEEL- 2) THIS DESIGN IS VALID ONLY WHEN PROPER CONSTRUCTION PRACTICES
SHEET NO. 03
a. For all footings = 60mm AND QUALITY CONTROL ARE IMPLEMENTED.
b. Columns = 40mm
c. Beams = 30mm
3) ALL DRAWINGS ARE SUBJECT TO SANCTION FROM CONCERNED
DRAWN BY : VINAY CLIENT : Mr. SURESH
d. Slabs = 20mm
AUTHORITIES.
e. Walls = 25mm
CHECKED BY : M.SANDEEP
4) LAP LENGTH SHALL BE A MINIMUM OF "50 TIMES THE DIA OF THE RESPECTIVE BAR". 4) ANY DISCREPANCIES WITH THE DRAWING SHALL IMMEDIATELY BE
BROUGHT TO THE NOTICE OF THE STRUCTURAL ENGINEER.
APPROVED BY : M.SANDEEP ORIENTATION
5) MORE THAN "50%" OF BARS SHALL NOT BE CURTAILED AT SAME PLACE.
5) ALL THE WORK SHALL BE CARRIED OUT STRICTLY AS PER DRAWINGS.
6) LAP LENGTH SHALL BE EQUAL TO DEVELOPMENT LENGTH(Ld) WHEREVER LAPS ARE
H NEEDED.
# GF 101, Aishwarya Grand, H
6) STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY
7) DISCREPANCY IF ANY SHALL IMMEDIATELY BE BROUGHT TO THE NOTICE OF THE FAULTY,INCORRECT OR DEFECTIVE WORK PRACTICE. DATE OF ISSUE : 14-02-2020 Krishna College Road, VSP-22.
ENGINEER-IN-CHARGE. Email: idesigns@outlook.com
7) THE PROVISIONS MADE IN IS:456-2000,SP34 AND OTHER RELEVANT CODES
8) GRADE OF CONCRETE = M20. SHALL BE STRICTLY ADHERED DURING EXECUTION.
9) GRADE OF STEEL = FE500. ALL DIMENSIONS ARE IN FEET UNLESS SPECIFIED. ARCHITECT STRUCTURAL ENGINEER