Beruflich Dokumente
Kultur Dokumente
All rights reserved. Any duplication of this Technical Documentation in part or whole, regard-
less of which mode, is forbidden without prior written permission of Horiba ATS. It is subject
to modifications without notice.
HORIBA
Automotive Test Systems GmbH
Landwehrstraße 55
64293 Darmstadt
Germany
http://www.ats.horiba.com
E-mail: services.hade@eu.horiba.com
Table of contents
1 Introduction....................................................................................... 5
9.1 STARS.............................................................................................. 18
9.1.1 x-one................................................................................................. 18
13 Service-Information ........................................................................ 20
1 Introduction
x-cas is a software product containing advanced functionality used in calibration of automo-
tive test stand equipment. Currently, x-cas may interface with the test bed automation sys-
tems
• x-one
• STARS
x-cas consists of two applications, x-cat and x-cam, which can be both installed using the
same setup installer program.
• x-cat (Calibration Tool) is used to perform the actual calibration task, whereas
• x-cam (Calibration Management) supports users in preparing and evaluating
calibration sessions.
Since x-cas is designed to be used in a distributed test field environment, x-cam may be e.g.
installed on a workstation in the operator’s office, whereas on each test bed system in the
test field an instance of x-cat is installed.
The common data required to handle calibration in a uniform way in a test field are referred
to as “ServerData”. In case of a test field environment, the ServerData will be stored on a file
server that can be accessed by all PC systems on which x-cam or x-cat is running. In a
stand-alone environment, however, the ServerData will reside on the local system.
X-cas V5.0.1 has been released for MS Windows 2000 and MS Windows XP systems.
Normally, after uninstallation the LocalData and ServerData folders and files have not been
removed.
Please note that x-cat can work together with a STARS test bed
automation system only, if the STARS binary folder is selected as
the target folder!
NOTE
The selection of “Everyone” or “Just me” has no influence on the further installation activities.
In case of an update installation, make sure you select the data folders of the previous instal-
lation. Otherwise x-cas will not be able to reuse the data of the existing installation, and will
instead work on a completely new dataset.
If the target folder already exists, the x-cas installer will recognize this, and display an input
box. First of all, it is important to understand that existing data files will never be overwrit-
ten by the installer.
However, in case of an update installation you may already have a complete set of data files.
In this case, pressing the “No” option will restore the necessary registry information, but not
copy any data files.
In case of an incomplete set of data files, it may be necessary to re-install the data at the tar-
get location. In this case, pressing “Yes” adds any data files that are not yet at the target lo-
cation.
Select “Cancel”, if you were unaware that the selected folder already exists, and you want to
change your selection.
- 'Configuration\Precision Classes'
- 'Latest\Precision Classes'
In the following screenshot, the corresponding file names (with their correct names) are
marked. Please replace the wrong character by ’°’ in your data.
If x-cat had already been started before the correction took place, the
same correction has to be made additionally in the replication folder.
NOTE
8.2 Log In
By default, the login for x-cat and x-cam is
• Username “Admin”
• Password “Admin”
You may want to change the Admin password in order to prevent unauthorized access to the
calibration functionality.
After this procedure the Calibration Management and the Calibration Tool have to be config-
ured.
1. Start the CalibrationManagement.exe and create a result structure for the calibration
result of the Test stand.
2. Start the Stars system and select a test stand, which contains calibrate devices.
3. Start the CalibrationTool.exe and complete the settings. Set the Archive path to the
correct calibration result location, which you create before within the Calibration Man-
agement (default: under c:\xcas\serverdata\result…). Then select the setup mode and
create the calibration specification based on the calibration information of the Stars
automation system. Now you can configure the devices, and calibrate the channels.
9.1 STARS
Register the CalibrationServer.dll. Do the following within the DOS box (within the bin-
directory of Stars):
C:\winnt\Microsoft.NET\….\regasm.exe CalibrationServer.dll
Use the explorer Search tool to find the correct .NET-Environment path
for regasm.exe.
NOTE
CAUTION
9.1.1 x-one
We assume that xone is correctly installed, and that CalibrationServer.exe is under the
\XONE\EXE folder, and that the PATH environment variable shows on the \XONE\EXE
folder.
If not, register the driver for the Calibration Standard MCXII manually.
Within a DOS box call:
regsvr32 CalibNormalMCX2.dll