Beruflich Dokumente
Kultur Dokumente
de has
executed?
B
C
2 Which DAQ board will allow for the detection of a 2.1 mV change in a signal if a 0-10 volt range was selected?
12-bit board
A
16-bit board
B
Both A. and B.
C
None of the above.
D
3 What is the result in subarray after the following code has executed?
a 1-D Array of {4, 6, 8}
A
a 1-D Array of {6, 8, 10}
B
a 1-D Array of {2, 4, 6}
C
a 1-D Array of {8, 16, 32}
D
B
4 What is the result in Output Array after the following code has executed?
5 Clicking on the _____ button allows you to bypass a node in the Block Diagram without single-stepping through
the node.
Step Over
A
Step Out
B
Step Through
C
Step Into
D
A
6 Which of the following is a required terminal connection for the Append Table to Report VI shown below?
row headers
A
report in
B
column width (1)
C
D column headers
7 What is the result in Array after the following code has executed?
C
D
Front Panel
A
Block Diagram
B
Both A. and B.
C
None of the above
D
B
11 Which of the following display options are available for strings on the Front Panel?
‘\’ Codes
A
Password
B
Hex
C
All of the above
D
D
12 The following figure is an example of which common type of VI architecture?
Parallel Loop VI
A
Multiple Case Structure VI
B
State Machine VI
C
General VI
D
C
14 To place an Express VI on the Block Diagram you would select it from the:
Tools Palette
A
Functions Palette
B
Icon Palette
C
Controls Palette
D
B
15 If N is 6, what is the value of T when this code is executed?
24
A
6
B
16
C
20
D
C
16 DAQmx channels and virtual channels are a collection of property settings that include all of the following,
EXCEPT:
type of measurement.
A
physical channel.
B
base I/O address.
C
scaling information.
D
C
29 Which of the following terminals supplies the current iteration number of a For or While Loop?
17 The _____ determines the total number of times a For Loop will execute and the _____ returns the number of
times the loop has executed minus one.
18 What is the result in Array after the following code has executed?
19 If an Error Cluster displays a non-zero error code coupled with a status of FALSE, it signals:
a warning.
A
a fatal error.
B
a non-fatal error.
C
no error.
D
A
B
C
21 If Number equals -49, then what is the result in Square Root Value after the following code has executed?
22 Which chart update mode shows running data continuously scrolling from left to right across the chart?
Step Chart
A
Scope Chart
B
Sweep Chart
C
Strip Chart
D
D
23 What is the result in Array after the following code has executed?
24 Which of the following methods will create an XY Graph with two plots?
Bundle the X and Y array pairs together into two clusters and then create an array of these two
A clusters.
Create a single array of each of the X arrays and Y arrays in an X, Y, X, Y pattern.
B
Create a single cluster from two arrays of X values and two arrays of Y values in an X, Y, X, Y pattern.
C
Bundle the X and Y array pairs together into two clusters and create a cluster of these two clusters.
D
A
Arrays
A
Clusters
B
Both A. and B.
C
None of the above
D
D
26 Which of the following is a recommended terminal connection for the Append Text Table to Report VI shown
below?
If two events occur at the same time, only the first event will be handled and the second will be lost.
A
The diagram becomes significantly larger when changing from a General VI to a State Machine VI.
B
A State Machine VI can only traverse states in order.
C
State Machines cannot acquire data or use DAQ functions.
D
A
33 Right clicking on the Block Diagram will cause which palette to display?
Tools Palette
A
Controls Palette
B
Printing Palette
C
Functions Palette
D
D
34 Which of the following statements is not true regarding the figure below?
It is not necessary to wire the count (N) terminal because auto-indexing is enabled.
A
Elements of Input Array enter the loop one at a time.
B
Output Array is the same size as Input Array.
C
If you disable auto-indexing on the right side of the For Loop, the output is still a 1-D Array.
D
All of the above statements are true
E
D
35 When creating a SubVI icon, the number of input terminals must match the number of:
output terminals.
A
Controls.
B
Indicators.
C
None of the above.
D
B
pass the error to the next node without executing the code in which the error occurred.
A
freeze the program and wait for user interaction.
B
immediately display a pop-up window describing the error.
C
execute normally.
D
A
39 Which of the following will continuously display multiple plots on the same Waveform Chart until the stop button
is pressed?
C
D
40 To access a graphical representation of all of the SubVI's and nodes that are called in the current VI, then: