2 1. General Description
3 2. Technical Description
5 3. Technical Specifications
1. General Descrip on
applications. They are available in 2 versions (single fan/double fan) and a total of 11 models with
KDA nominal capacities ranging from 7.1 kW to 91.3 kw in cooling and 16.7kw - 182.5kw in heating
depending on the external static pressure and air volumes from 1.440m3/h to 11.600m3/h.
This series is ideal in combination with Klimallco air cooled water chillers or heat pumps for air
conditioning oices, shops or any other commercial application, where oor and wall space is needed
for fittings and furniture, allowing various air ow pattern flexibility through ducts according to the room
2
2. Technical Descrip on
These units are large ducted fan coil units, that can be freely configured (according to wished combination)
selecting between:
Huge flexibility
Winning idea: the wide range of sections and available accessories, allows to realize practically unlimited
combinations, always finding the right solution able to meet your needs, whatever they are!
Highly efficient coil (Turbulenced Fins with a high number of Reynolds) made of copper pipes and aluminium fins fixed by
mechanical expansion. Coil without air vent valves. Coils tested at 30 Bar pressure, suitable to work with water at max 15 Bar
pressure.
Standard connections on the right side; on request (no additional charge) connections on the left side, anyway can be easily
reversed even on working site.
Coils are suitable to work with hot water (boiler), low temperature water (condensing boilers, solar panels, heat pumps, etc…),
overheat water (industrial processes and/or overheat water thermal groups) chilled water (chillers and/or industrial processes),
glycol added water.
- coils are suitable for 2-pipe systems (3R, 6R) and 4-pipe systems (3R+2R) 3 rows for cooling, 2 rows for heating
- 6 rows coils usually used for cooling, with total external (or even partial) renewal air, in case it is required high
dehumidification, also suitable for district cooling applications, with high water ΔT.
Klimallco sa
Fan Coil Units
3
Technical Descrip on
single inclination drain pan for optimised condensate insulation (class M1). On request drain pan made of
according with the specifications (self- permanently switched on, IP 42, Class B, electric
Fan section including 1 or 2 centrifugal fans with Manufactured according with the international
(min. 7 poles: 1 Ground + 3 speed + 1 Common + 2 for Available, as accessories, an additional range of
Bridge) installed outside the unit (for horizontal units, terminal boards (terminal board with lead, terminal
on the same side of the water connections ; for board inside IP 55 electrical box, etc.).
WARNING: it is prohibited to make the unit operate if both the outlets of the unit are not ducted or protected by grills or safety net
(available as accessories on request: grills, panels, plenum, etc.).
Klimallco sa
Fan Coil Units
4
3. Technical Specifica ons
3Rows models
KDA KDA KDA KDA KDA KDA KDA KDA KDA KDA KDA
Type
130 230 330 430 530 630 1230 1330 1430 1540 1640
Total (1) kW 7,1 11,7 14,3 16,5 21,6 29,1 24 29,3 33 56,5 68,5
Cooling capacity
Sensible (1) kW 5,8 9,8 11,7 13,6 17,8 23,7 20,2 23,9 27,2 43,1 54
Heating capacity (2) kW 16,7 28,2 34 39,4 51,3 68,2 58,6 69,2 78,3 121,9 153,3
Nominal Air flow (3) m3/h 1.440 2.480 2.890 3.350 4.800 5.800 4.970 5.770 6.700 9.600 11.600
Cooling l/h 1.222 2.013 2.460 2.838 3.716 5.006 4.128 5.040 5.676 9.718 11.782
Water flow (4)
Heating l/h 1.437 2.426 2.924 3.389 4.412 5.866 5.040 5.952 6.734 10.484 13.184
Cooling kPa 26,2 27,3 28,5 25,9 26,6 31,3 25,7 26 27,3 30,6 33,4
Water pressure drops (5)
Heating kPa 28,3 30,9 31,4 28,8 29,2 33,5 29,9 28,3 30 27,8 32,6
Rows No. 3R 3R 3R 3R 3R 3R 3R 3R 3R 4R 4R
Heating/cooling coil
Connections DN (*) 3/4” M 1” M 1” M 1” M 1”-1/4 M 1”-1/2 M 1”-1/4 M 1”-1/2 M 1”-1/2 M 1”-1/2 M 1”-1/2 M
Drain pipe φ (mm) 30 30 30 30 30 30 30 30 30 30 30
Dimensions A1 mm 360 425 425 480 550 550 425 425 480 580 580
D B1 mm 560 660 760 760 1.160 1.360 1.160 1.360 1.360 1.660 1.660
Concealed versions
C1 mm 840 995 1.105 1.160 1.140 1.240 995 1.105 1.160 1.450 1.450
Dimensions A mm 380 440 440 480 570 570 440 440 480 600 600
F-H-K B * mm 520 620 720 720 1.120 1.320 1.120 1.320 1.320 1.620 1.620
Versions with Cabinet
C mm 870 1.020 1.120 1.160 1.150 1.250 1.020 1.120 1.160 1.470 1.470
versions D-F-H kg 35,8 46,6 55,7 60,6 93,7 107,8 78,5 94,8 103,5 179,1 181,1
Net weight
versions K kg 45,1 59,5 71,3 77,3 118,9 138,7 99,7 121,4 131,4 224,4 226,4
Fans/Motors Number No./No. 1/1 1/1 1/1 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2
1x 1x 1x 1x 1x 1x 2x 2x 2x 2x 2x
Ref. fan section
Ref. D1(0707) D2(0907) D3(0909) D5(1010) D6(1209) D7(1212) D2(0907) D3(0909) D5(1010) D6(1209) D7(1212)
6 P (6 poles) Motor 230Vac-1Ph-50Hz ; 6 Poles (nominal RPM in max speed = 900 g/min); 3 speed
Current input MAX(6) A 1x 1,2A 1x 2,6A 1x 2,5A 1x 2,7A 1x 6,6A 1x 6,8A 2x 2,6A 2x 2,5A 2x 2,7A 2x 6,6A 2x 6,8A
Sound levels Min-Med-Max (7) dB(A) 35-42-44 43-46-49 41-45-47 37-42-46 49-52-54 45-48-50 46-49-52 44-48-50 40-45-49 52-55-57 48-51-53
4P (4 poles) Motor 230Vac-1Ph-50Hz ; 4 Poles (nominal RPM in max speed = 1400 g/min); 3 speed
Current input MAX(6) A 1x 2,2A 1x 4,4A 1x 3,8A 1x 6,3A \ \ 2x 4,4A 2x 3,8A 2x 6,3A \ \
Sound levels Min-Med-Max (7) dB(A) 38-44-48 36-43-52 35-42-50 40-45-50 \ \ 39-46-55 38-45-53 43-48-53 \ \
Air flow 1,2 1,1 1,1 1 1 0,9 0,9 0,8 0,8 0,7 0,7 0,6 0,6 0,5 0,5 0,4 0,4 0,3 0,3 0,2 0,2
Total 1,1 1,1 1 1 1 0,9 0,9 0,9 0,8 0,8 0,8 0,7 0,7 0,7 0,6 0,6 0,5 0,5 0,4 0,4 0,3
Cooling capacity
Sensible 1,1 1,1 1 1 1 0,9 0,9 0,9 0,8 0,8 0,7 0,7 0,7 0,6 0,6 0,5 0,5 0,4 0,4 0,3 0,3
Heating capacity 1,1 1,1 1 1 1 0,9 0,9 0,9 0,8 0,8 0,7 0,7 0,7 0,6 0,6 0,5 0,5 0,4 0,4 0,3 0,3
Klimallco sa
Fan Coil Units
5
Technical Specifica ons
6Rows models
KDA KDA KDA KDA KDA KDA KDA KDA KDA KDA KDA
Type
160 260 360 460 560 660 1260 1360 1460 1560 1660
Total (1) kW 10,9 18,5 22,8 26,9 35,1 45,9 39,1 46,3 53,3 72,6 91,3
Cooling capacity
Sensible (1) kW 7,8 13,6 16,3 19,3 25,2 32,9 28,6 33,3 38,3 51,5 66
Heating capacity (2) kW 21,6 38,1 45 53,3 69,7 90,8 80 92 106 141,2 182,5
3
Nominal Air flow (3) m /h 1.320 2.420 2.840 3.350 4.800 5.800 4.830 5.680 6.700 9.600 11.600
Cooling l/h 1.875 3.182 3.922 4.627 6.038 7.895 6.726 7.964 9.168 12.488 15.704
Water flow (4)
Heating l/h 1.858 3.277 3.870 4.584 5.995 7.809 6.880 7.912 9.116 12.144 15.695
Cooling kPa 29,7 31,1 31,8 29,8 31,6 31 29,4 29 31,6 32,3 33
Water pressure drops (5)
Heating kPa 22,7 25,7 24,2 22,8 24,3 23,7 24 22,3 24,4 23,8 25,7
Rows No. 6R 6R 6R 6R 6R 6R 6R 6R 6R 6R 6R
Heating/cooling coil
Connections DN (*) 3/4” M 1” M 1” M 1” M 1”-1/4 M 1”-1/2 M 1”-1/4 M 1”-1/2 M 1”-1/2 M 1”-1/2 M 1”-1/2 M
Drain pipe φ (mm) 30 30 30 30 30 30 30 30 30 30 30
Dimensions A1 mm 360 425 425 480 550 550 425 425 480 580 580
D B1 mm 560 660 760 760 1.160 1.360 1.160 1.360 1.360 1.660 1.660
Concealed versions
C1 mm 840 995 1.105 1.160 1.140 1.240 995 1.105 1.160 1.450 1.450
Dimensions A mm 380 440 440 480 570 570 440 440 480 600 600
F-H-K B * mm 520 620 720 720 1.120 1.320 1.120 1.320 1.320 1.620 1.620
Versions with Cabinet
C mm 870 1.020 1.120 1.160 1.150 1.250 1.020 1.120 1.160 1.470 1.470
versions D-F-H kg 41,8 54,1 64,7 69,6 108,7 125,8 93,5 112,8 121,5 201,6 203,6
Net weight
versions K kg 51,1 67 80,3 86,3 133,9 156,7 114,7 139,4 149,4 246,9 248,9
Fans/Motors Number No./No. 1/1 1/1 1/1 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2
1x 1x 1x 1x 1x 1x 2x 2x 2x 2x 2x
Ref. fan section
Ref. D1(0707) D2(0907) D3(0909) D5(1010) D6(1209) D7(1212) D2(0907) D3(0909) D5(1010) D6(1209) D7(1212)
6 P (6 poles)
Current input MAX(6) A 1x 1,2A 1x 2,6A 1x 2,5A 1x 2,7A 1x 6,6A 1x 6,8A 2x 2,6A 2x 2,5A 2x 2,7A 2x 6,6A 2x 6,8A
Sound levels Min-Med-Max (7) dB(A) 35-42-44 43-46-49 41-45-47 37-42-46 49-52-54 45-48-50 46-49-52 44-48-50 40-45-49 52-55-57 48-51-53
4P (4 poles)
Current input MAX(6) A 1x 2,2A 1x 4,4A 1x 3,8A 1x 6,3A \ \ 2x 4,4A 2x 3,8A 2x 6,3A \ \
Sound levels Min-Med-Max (7) dB(A) 38-44-48 36-43-52 35-42-50 40-45-50 \ \ 39-46-55 38-45-53 43-48-53 \ \
Air flow 1,15 1,1 1,05 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 0,45 0,4 0,35 0,3 0,25 0,2 0,15
Total 1,11 1,07 1,04 1 0,96 0,92 0,89 0,85 0,81 0,77 0,72 0,68 0,64 0,59 0,55 0,5 0,46 0,41 0,35 0,3 0,24
Cooling capacity
Sensible 1,13 1,08 1,04 1 0,96 0,91 0,87 0,83 0,78 0,74 0,69 0,65 0,6 0,55 0,51 0,46 0,41 0,36 0,31 0,25 0,2
Heating capacity 1,13 1,08 1,04 1 0,96 0,91 0,87 0,83 0,78 0,74 0,69 0,65 0,6 0,55 0,51 0,46 0,41 0,36 0,31 0,25 0,2
Klimallco sa
Fan Coil Units
6
Technical Specifica ons
ESP (Pa)
Qa
50
External static pressure (Pa)
Air flow 1,2 1,1 1,1 1 1 0,9 0,9 0,8 0,8 0,7 0,7 0,6 0,6 0,5 0,5 0,4 0,4 0,3 0,3 0,2 0,2
Total 1,1 1,1 1 1 1 0,9 0,9 0,9 0,8 0,8 0,8 0,7 0,7 0,7 0,6 0,6 0,5 0,5 0,4 0,4 0,3
Cooling capacity
Sensible 1,1 1,1 1 1 1 0,9 0,9 0,9 0,8 0,8 0,7 0,7 0,7 0,6 0,6 0,5 0,5 0,4 0,4 0,3 0,3
Heating capacity 1,1 1,1 1 1 1 0,9 0,9 0,9 0,8 0,8 0,8 0,7 0,7 0,7 0,6 0,6 0,5 0,5 0,4 0,4 0,3
Klimallco sa
Fan Coil Units
7
climate experience