Sie sind auf Seite 1von 18

SECTION 6.

1 into an ammeter of 0-15 A range, the resistance


of shunt should be:
The use of a multimeter with digital circuits
allows the measurement of: Correct Answer :

Correct Answer : 0.004 Ω

voltage or resistance A moving coil instrument has a resistance of 0.5


Ω and a full scale deflection of 0.1 A. To convert
it into an ammeter of 0-10 A the shunt
The instrument used to check insulation of resistance should be:
household wiring is: Correct Answer :
Correct Answer : 0.005 Ω
Megger

Assertion (A):A hot wire ammeter has a


An ammeter is: cramped scale.

Correct Answer : Reason (R): The heat is proportional to square


of current.
secondary instrument
Correct Answer :

Both A and R are true and R is correct


The accuracy of a multimeter is about: explanation of A

Correct Answer :

± 3% In a thermocouple temperature transducer, the


output voltage is usually measured by:

Correct Answer :
An ammeter of 0-25 A range has a guaranteed
accuracy of 1% of full scale reading. The current high resistance milli-voltmeter
measured is 5 A. The limiting error is:

Correct Answer :
Assertion (A):Shunt of an ammeter has a low
5% resistance.

Reason (R): Shunt may be connected in series or


in parallel with ammeter.
A moving coil instrument has a resistance of 0.6
Ω and full scale deflection at 0.1 A. To convert it Correct Answer :
A is true R is false

The loading effect of a voltmeter can be ignored


if ____.
The D'Arsonval- movement can be converted
into audio frequency ac ammeter by adding a: Correct Answer :

Correct Answer : the meter's resistance is at least 10 times


greater than the resistance across which it is
rectifier connected

A 0-200 V voltmeter has an accuracy of 0.75% Which of the following voltmeters would you
of full scale reading. If voltage measured is 100 use for measuring voltage across 20 kΩ
V, the error is: resistance?
Correct Answer : 1.5% Correct Answer :
A meter coil has a resistance of 100 Ω and a full Voltmeter having sensitivity of 10 kW/V
scale deflection current of 10 mA. To convert it
into a voltmeter of 0-200 V range, the series
resistance should be:
A digital voltmeter has a read out range from 0
Correct Answer : to 999 counts. If the full scale reading is 9.999
V, the resolution is:
19.9 kΩ
Correct Answer :

1 mV
In figure, the position of voltmeter and
ammeter are exchanged. It may result in
damage to:
A meter with a resistance of 100 ohm and a full
Correct Answer : scale deflection of current of 1 mA is to be
converted into voltmeter of 0-5 V range. The
ammeter multiplier resistance should be:

Correct Answer: 4900 ohms


When a Wheatstone bridge is in a balanced
condition, the center voltmeter in the bridge
will read: A full wave rectifier type meter is used to
measure the wave shape shown in figure. The
Correct Answer : voltmeter is calibrated to read rms value of sine
zero volts wave. The reading of voltmeter will be:

Correct Answer: 111 V


Potentiometer method of dc voltage The dynamometer principle can be used for:
measurement is more accurate than direct
Correct Answer :
measurement using a voltmeter because:

Correct Answer : ammeter, voltmeter and wattmeter

it does not load the circuit at all


Assertion (A):In hot wire instrument the
material of hot wire in generally platinum
A voltmeter using thermocouples measures: iridium.

Correct Answer : Reason (R): A hot wire ammeter is suitable for


ac only.
rms value
Correct Answer :

A is true R is false
A moving iron voltmeter reads 250 V when
connected to 250 V dc. If connected to 250 V 50
Hz, the voltmeter reading is likely to be:
The scale of hot wire ammeter is:
Correct Answer :
Correct Answer :
248 V
non-linear

Two voltmeters 0-250 V each having resistances


of 5 kΩ and 10 kΩ respectively and are The effect of lead resistance is important in
measurement of:
connected in series. To ensure that neither of
them goes beyond scale the total voltage which Correct Answer :
can be applied should be less than:
both resistance of shunt and resistance of
Correct Answer : ammeter
375 V

Two ammeters A and B are connected in


parallel in a circuit carrying 100 A. Their
Which of the following is not correct?
resistances are 0.8 mΩ. Their readings will be:
Correct Answer :
Correct Answer :
An electronic voltmeter draws appreciable
current from source 55.56 and 44.44 A respectively
Questions The power factor of a single phase voltmeters should be connected: Correct
load can be calculated if instruments available Answer : across the resistance
are: Correct Answer : one voltmeter, one
An ammeter has a resistance of 50 ohms and a
ammeter and one wattmeter Check Details
Here shunt of 0.01 Ω. The deflection is θ. If the
shunt resistance is increased to 0.02 Ω, the
A resistance is measured by voltmeter- deflection will be: Correct Answer : 2θ
ammeter method. The voltmeter is 0-250V, ±
A moving coil meter has a resistance of 50
1% accuracy and ammeter is 0-5 A, ± 1 %
accuracy. The readings of voltmeter and ohms and a full scale deflection current of 20
mA. To convert it into a voltmeter of 0-100 V
ammeter are 100 V and 2 A respectively. The
error in the measured resistance can be: range, the series resistance should be: Correct
Answer : 4950 Ω
Correct Answer : ± 5%

A meter has a resistance of 1 Ω and full scale Questions Assertion (A):If the resistance of
shunt of an ammeter is increased, the range of
deflection current of 1 mA. To convert into an
ammeter of 1 A range, the shunt resistance ammeter is reduced. Reason (R): If the series
resistance of a voltmeter is increased, the
should be: Correct Answer : 0.001 Ω Check
Details Here range of voltmeter is increased. Correct
Answer : Both A and R are true but R is not
A moving coil meter has 10 Ω resistance and correct explanation of A Check Details
requires 40 mA for full scale deflection. The
Assertion (A):The scale a PMMC ammeter is
shunt resistance required to convert it into 0-2
A ammeter is: Correct Answer : 0.2041 Ω linear. Reason (R): The deflecting torque of
PMMC is proportional to current in the coil.
A 1 mA meter is to be converted to 1 A Correct Answer : Both A and R are true and R is
ammeter. The meter resistance is 100 Ω. The correct explanation of A
value of shunt resistance is: Correct Answer :
0.1001 Ω Heating effect of current is used in: Correct
Answer : both ammeters and voltmeters Check
The function of shunt in an ammeter is to: Details Here
Correct Answer : by pass the current
Magnetic effect of current is used in: Correct
Two ammeters having resistances of 0.5 Ω and Answer : ammeters, voltmeters, wattmeters
0.25 Ω and having full scale reading of 25 A and energy meters
each are connected in parallel. To ensure that
neither of them goes beyond scale, the total Assertion (A):Electrodynamic instrument is not
used as ammeter or voltmeter. Reason (R):
current should not be more than: Correct
Answer : 37.5 A Electrodynamic instrument is more costly than
PMMC and moving iron instrument. Correct
In measuring a resistance by voltmeter- Answer : Both A and R are true and R is correct
ammeter method, the voltmeter can be explanation of A
connected either across supply or across the
resistance. If the resistance is low, the
A peak responding ac voltmeter using a half Assertion (A):In hot wire instrument the
wave rectifier has been calibrated to read 1 V material of hot wire in generally platinum
for 1 V rms sine wave input. If input is 1 V dc iridium. Reason (R): A hot wire ammeter is
the reading will be: Correct Answer : 0.707 or 0 suitable for ac only. Correct Answer : A is true
V R is false

The circuit of figure is used to measure the The scale of hot wire ammeter is: Correct
value Rx. Ammeter resistance Ra= 0.1 Ω Answer : non-linear Check Details Here
voltmeter resistance Rv = 5000 Ω. It Rx1 and
Rx2, are the measured values of Rx with switch A moving coil meter has a shunt of 0.02 Ω
resistance. If coil resistance is 1000 Ω and a
in position 1 and 2, the mean of Rx1, and Rx2,
is: Correct Answer : 10.04 Ω potential difference of 500 mV is required
across it to cause full scale deflection, the
DC voltage of the order of a few mV can be current through shunt is: Correct Answer : 25 A
accurately of measured by: Correct Answer :
Consider the following features of an
null balancing potentiometer Check Details
Here instrument. suitable for both ac and dc free
from hysteresis and eddy current errors No
The method of frequency compensation in waveform and frequency errors it is essentially
moving iron voltmeter is: Correct Answer : to a voltmeter This instrument is: Correct
connect a capacitor in parallel with series Answer : electrostatic
resistance
The effect of lead resistance is important in
It is required to measure the true open circuit measurement of: Correct Answer : both
emf of a battery. The best device is: Correct resistance of shunt and resistance of ammeter
Answer : dc potentiometer Check Details Here

Questions A sinusoidal ac voltage of amplitude A high resistance was measured by loss of


100 V is applied to a rectifying device which charge method. The voltmeter resistance was
offers 10 Ω resistance in forward direction and 1010 ohms. The calculation gave the value of
infinite resistance in reverse direction. The unknown resistance as 0.8 x 109ohms. The
reading on hot wire ammeter will be: Correct true value of resistance is: Correct Answer :
Answer : 5 A more than 0.8 x 109 Ω

The current in a circuit is measured using a 150 Two ammeters A and B are connected in
: 1 CT If the ammeter reads 0.6 A, the circuit parallel in a circuit carrying 100 A. Their
current is: Correct Answer : 90 A Check Details resistances are 0.8 mΩ. Their readings will be:
Here Correct Answer : 55.56 and 44.44 A
respectively Check Details Here
Two ammeters A and B both 0-10 A have
internal resistance of 1 Ω and 0.5 Ω
respectively. They are connected in parallel. If
Questions
total current is 15 A, then: Correct Answer : IA
= 5 A, IB = 10 A
An LVDT is used to measure displacement. The Two meters X and Y require 40 mA and 50 mA
LVDT feeds a Voltmeter of 0-5 V range through for full scale deflection. Then:
a 250 gain amplifier. For a displacement 0.5 mm
the output of LVDT is 2 mV. The sensitivity of
instrument is: Correct Answer :

it is not possible to determine from given data


Correct Answer :

1 V/mm In a Ballistic galvanometer:


Check Details Here

In a moving iron voltmeter the coil has a Correct Answer :


resistance of 20 Ω and an inductance of 0.3 H.
The swamping resistance in 2000 Ω. To ensure inertia is large and damping is small
correct reading with dc as well as 50 Hz ac, the
Check Details Here
value of capacitor to be connected in parallel
with swamping resistance should be: When deflecting torque and braking torque in
an energy meter are zero.

Correct Answer :
Correct Answer :
0.0311 μF
the disc rotates at steady speed

Heating effect of current is used in:


In an Anderson bridge the unknown inductance
is measured in terms of:
Correct Answer :

both ammeters and voltmeters


Correct Answer :
Check Details Here
known capacitance and resistance
For measuring mutual inductance we can use:

An LVDT is used to measure displacement. The


Correct Answer : LVDT feeds a Voltmeter of 0-5 V range through
a 250 gain amplifier. For a displacement 0.5 mm
Heaviside bridge the output of LVDT is 2 mV. The sensitivity of
instrument is:
248 V

Correct Answer : Check Details Here

1 V/mm The use of a multimeter with digital circuits


allows the measurement of:

A moving coil instrument has a resistance of 0.6


Ω and full scale deflection at 0.1 A. To convert it Correct Answer :
into an ammeter of 0-15 A range, the resistance
voltage or resistance
of shunt should be:

Assertion (A):The scale a PMMC ammeter is


Correct Answer :
linear.
0.004 Ω
Reason (R): The deflecting torque of PMMC is
Check Details Here proportional to current in the coil.

Questions Correct Answer :

Which of the following voltmeters would you Both A and R are true and R is correct
use for measuring voltage across 20 kΩ explanation of A
resistance?

An ammeter is:
Correct Answer :

Voltmeter having sensitivity of 10 kW/V


Correct Answer :

secondary instrument
The coil of a moving iron instrument has a
resistance of 500 Ω and an inductance of 1 H. It
reads 250 V when a 250 V dc is applied. If series An ammeter of 0-25 A range has a guaranteed
resistance is 2000 Ω, its reading when fed by accuracy of 1% of full scale reading. The current
250 V, 50 Hz ac will be: measured is 5 A. The limiting error is:

Correct Answer : Correct Answer :


5% Correct Answer :

rms value

A moving coil instrument has a resistance of 0.5


Ω and a full scale deflection of 0.1 A. To convert
it into an ammeter of 0-10 A the shunt
resistance should be: Questions

Assertion (A): Shunt of an ammeter has a low


resistance.
Correct Answer :

0.005 Ω Reason (R): Shunt may be connected in series or


in parallel with ammeter.

Potentiometer method of dc voltage


measurement is more accurate than direct
measurement using a voltmeter because: Correct Answer :

A is true R is false
Correct Answer :

it does not load the circuit at all The D'Arsonval- movement can be converted
Check Details Here into audio frequency ac ammeter by adding a:

Assertion (A):A hot wire ammeter has a


cramped scale. Correct Answer :
Reason (R): The heat is proportional to square rectifier
of current.

A moving iron voltmeter reads 250 V when


connected to 250 V dc. If connected to 250 V 50
Hz, the voltmeter reading is likely to be:
Correct Answer :

Both A and R are true and R is correct


explanation of A Correct Answer :
Check Details Here 248 V
A voltmeter using thermocouples measures: Check Details Here
A 0-200 V voltmeter has an accuracy of 0.75% 3.185 A
of full scale reading. If voltage measured is 100
V, the error is:
A digital voltmeter has a 4 1/2 digit display. The
1 V range can measure voltage up to:
Correct Answer :

1.5%
Correct Answer :

0.199 V
A meter coil has a resistance of 100 Ω and a full
scale deflection current of 10 mA. To convert it
into a voltmeter of 0-200 V range, the series In a thermocouple temperature transducer, the
resistance should be: output voltage is usually measured by:

Correct Answer : Correct Answer :


19.9 kΩ high resistance milli-voltmeter

In figure, the position of voltmeter and Which of these has poor overload capacity?
ammeter are exchanged. It may result in
damage to:

Correct Answer :

Correct Answer : Hot wire instrument

ammeter

Check Details Here

A sinusoidal ac voltage of amplitude 100 V is Questions


applied to a rectifying device which offers 10 Ω
A rectifier voltmeter using bridge rectifier and
resistance in forward direction and infinite
PMMC meter is calibrated to read rms value of
resistance in backward direction. A moving coil
sine wave. A triangular wave is applied to it and
ammeter is also connected in the circuit. The
it reads 6.82 V. The rms value of triangular wave
reading of ammeter will be:
is:

Correct Answer :
Correct Answer :
about 7.1 V 100 V, 0.1 mA

Check Details Here

Two voltmeters are each 0-300 V range. Their The deflection of a DArsonval galvanometer is
internal resistances are 10 kΩ and 20 kΩ They measured through a mirror and scale. The
are connected is series and a voltage of 400 V is mirror is 1 m away from the light source. The
applied. Their readings respectively will be: mirror is mounted on, the moving system. If
mirror rotates through 0.2 rad the displacement
on the scale is:
Correct Answer :

133.3 and 266.6 V Correct Answer :

0.4 m
A 300 V voltmeter has an accuracy of ± 2% of
full scale deflection. When the reading is 222 V,
the actual voltage: Two ammeters having resistances of 0.5 Ω and
0.25 Ω and having full scale reading of 25 A
each are connected in parallel. To ensure that
Correct Answer : neither of them goes beyond scale, the total
current should not be more than:
lies between 216 and 228 V

Correct Answer :
What would be the reading of voltmeter as
shown in below figure. The voltmeter has a 0-1 37.5 A
V scale and is a 20000 Ω/V meter:

A moving coil meter has a resistance of 50 ohms


Correct Answer : and a full scale deflection current of 20 mA. To
convert it into a voltmeter of 0-100 V range, the
0.082 V series resistance should be:

Four voltmeters have following specifications. If Correct Answer :


accuracy is main consideration which is the
best? 4950 Ω

Check Details Here

Correct Answer : In measuring a resistance by voltmeter-


ammeter method, the voltmeter can be
connected either across supply or across the Figure shows a Wheatstone bridge
resistance. If the resistance is low, the with RTD to one arm. If resistance of
voltmeters should be connected: RTD = 1020 Ω, the voltage V0 is: 49
mV

The ac bridge in figure is balanced.


Correct Answer : Z1 = 100∠30°, Z2 = 150∠0°, Z3 = 250∠
- 40° Then Z4 = 375∠ - 70° Ω
across the resistance
In bridge circuit of figure, equivalent
Check Details Here resistance between A and B is: 1 Ω

Test 1 Assertion (A): Double Kelvin's bridge is


used to measure low resistances.
In figure the bridge is balanced when
Z4 is balanced when Z4 is: 187.5 < Reason (R): In low resistance, the
-70 deg. contact and lead resistances are very
important. Both A and R are true
and R is correct explanation of A
In the wheatstone bridge in figure,
each resistance is increased by 0.05%. Test 2
The value of v0 will be: zero
Assertion (A): Hay's bridge in
particularly suitable for measuring
Consider the following operation in
inductance having a comparatively
respect of Wheatstone bridge (Kb,
low resistance.
denotes battery key, Kg denotes
Reason (R): In Hay's bridge the value
galvanometer key) : 3, 2, 4, 1
of frequency supply must be known.
Both A and R are true but R is not
In the balanced bridge shown in
figure. X should be : a self correct explanation of A
inductance having resistance
De Sauty bridge is very widely used
Assertion (A): Maxwell bridge is for due to simplicity
measuring inductance of medium
magnitude. To measure dielectric loss you would
Reason (R): In Maxwell's bridge the use: Schering bridge
unknown inductance is measured by
comparing it with a capacitance. : A is For measurement of high voltage
true R is false capacitors the suitable bridge is:
Schering bridge
Assertion (A): A universal RLC bridge
has a battery and also a high To avoid the effect of stray magnetic
frequency ac source. fields in ac bridge we can use:
Reason (R): RLC bridge uses a magnetic screening
Wienbridge arrangement for
measuring capacitance. A is true R is In ac bridge measurements, 'Wagner
false ground' means: a special RC
connection to eliminate stray
capacitance effects
A logic probe is placed on the output of a gate
Assertion (A): Wien bridge can be and the display indicator is dim. A logic pulser is
used for measuring frequency. used on each of the input terminals, but the
Reason (R): A frequency meter for 50
output indication does not change. What is
Hz system has a frequency range of
40 to 60 Hz. wrong?
A is true R is false

Assertion (A): Schering bridge is a


low voltage bridge. Correct Answer :
Reason (R): Schering bridge is very
commonly used for measurement of The output of the gate appears to be open.
capacitance.
A is false R is true

When a Wheatstone bridge is in a A +5 V PCB power source that has been "pulled
balanced condition, the center down" to a +3.4 V level may be due to:
voltmeter in the bridge will read: zero
volts
Correct Answer :

a circuit short

Check Details Here


Questions
Measurement of pulse width should be taken at
A series of gradually decreasing sine wave
a 50% mean of the:
oscillations is called:

Correct Answer :
Correct Answer :
rise and fall
Ringing

Which test equipment best allows a comparison


The determination of a digital signal's frequency
between input and output signals?
and waveshape is best accomplished with which
test equipment?

Correct Answer :
Correct Answer : a multitrace oscilloscope
an oscilloscope
The use of triggered sweep when using an In a CRO, the frequency of output of time base
oscilloscope provides more accuracy in which generator:
area?

Correct Answer :
Correct Answer :
is adjustable
timing
Check Details Here

A sinusoidal signal is measured by CRO. The


In measurements using CRO, Lissajous patterns scale is set at 4 mV/cm. If vertical distance
are used to: between positive and negative peaks is 6 cm,
the peak value of ac signal is:

Correct Answer :
Correct Answer :
measure frequency
12 mV
Check Details Here

The input impedance of CRO is about:


Two sinusoidal signals of equal amplitude and
frequency are applied to X and Y plate of CRO
Correct Answer : respectively. The observed Lissajous pattern is a
straight line. The phase shift between signals is:
one mega ohm

Check Details Here


Correct Answer :
It is required to study transients during
switching process. Which CRO should be either zero or 180°
preferred?

A dual trace CRO has:


Correct Answer :

Storage oscilloscope Correct Answer :

one electron gun with one two pole switch

Questions
The Y plates of a CRO are excited by a voltage 2
sin 100 tand the X plates are not connected.
The display would be: The time base generator in a CRO gives an
output which is:

Correct Answer :
Correct Answer :
a vertical line
high frequency sawtooth

Check Details Here


Assertion (A): When frequencies of signals fed
to X and Y plates of CRO are multiples of each Both X and Y plates of a CRO are excited by ac
signals. The display is an ellipse which makes
other, Lissajous pattern is displayed on screen.
one rotation in 5 seconds. This means that:
Reason (R): In a CRO, the vertical deflection is
proportional to voltage applied to Y plates.
Correct Answer :

the difference between the frequencies of the


two signals is one fifth of hertz
Correct Answer :

Both A and R are true but R is not correct


explanation of A
Questions

The increase in intensity of trace in a CRO In a CRO, the time base signal is applied to:
causes a change in:

Correct Answer :
Correct Answer : X plates
beam current Check Details Here
Check Details Here Assertion (A):CRT is the most important
The accuracy of measurement using CRO is component of a CRO.
about: Reason (R): When an electron beam strikes the
screen of CRT, a spot of light is produced.

Correct Answer :

± 3%
Correct Answer :

Both A and R are true but R is not correct Correct Answer :


explanation of A
ringing

Check Details Here


Assertion (A):CRO can be used to study
The determination of a digital signal's frequency
waveshape accurately.
and waveshape is best accomplished with which
Reason (R): Input impedance of a CRO is very test equipment?
high.

Correct Answer :

an oscilloscope
Correct Answer :

Both A and R are true and R is correct


explanation of A Which test equipment best allows a comparison
between input and output signals?
Check Details Here

The numbers of accelerating anodes in a CRO is:


Correct Answer :

a multitrace oscilloscope
Correct Answer :

2
The use of triggered sweep when using an
Check Details Here oscilloscope provides more accuracy in which
area?
The time base of a high frequency CRO whose
screen diameter is 10 cm is set at 10 μ sec/cm.
The lowest frequency which can be fully
displayed on the screen is: Correct Answer :

timing

Correct Answer :
The time needed for a pulse to increase from
equal to 10 kHz
10% to 90% of its amplitude defines:

A series of gradually decreasing sine wave


oscillations is called: Correct Answer :
rise time 2 sin ωt

Check Details Here

When measuring phase angle between two


waves using a CRO, the time base generator is
Questions connected to:
In a CRO which of the following is not a part of
electron gun.
Correct Answer :

neither X nor Y plates


Correct Answer :

X - Y plates
The input impedance of CRO is about:

The Y plates of a CRO are excited by a voltage 2


sin 100 t and the X plates are not connected. Correct Answer :
The display would be:
one mega ohm

Correct Answer :
It is required to study transients during
a vertical line switching process. Which CRO should be
preferred?

A dual trace CRO has:


Correct Answer :

Storage oscilloscope
Correct Answer :

one electron gun with one two pole switch


In a CRO, the frequency of output of time base
generator:
The Lissajous pattern observed on screen of
CRO is a straight line inclined at 45° to x axis. If
X-plate input is 2 sin ωt, the Y-plate input is: Correct Answer :

is adjustable

Correct Answer :
A sinusoidal signal is measured by CRO. The Magnetic effect of current is used in ammeters,
scale is set at 4 mV/cm. If vertical distance voltmeters, wattmeters and energy meters
between positive and negative peaks is 6 cm,
Which instrument is based on induction
the peak value of ac signal is:
principle? Both (b) and (c)

Power monitor and reflectometer use the


Correct Answer : principle of directional coupler

12 mV If a shunt of 200 Ω resistance is used with a


galvanometer of 1000 Ω resistance, the
multiplying power is 6
Two sinusoidal signals of equal amplitude and Induction wattmeter can be used in ac circuit
frequency are applied to X and Y plate of CRO only
respectively. The observed Lissajous pattern is a
straight line. The phase shift between signals is: Consider the following statements as regards
induction and dynamometer wattmeters 2 and
3 only
Correct Answer : How is power dissipated in a resistor? By Heat
either zero or 180° In 3 phase power measurement by two
wattmeter method, the reading of one
wattmeter is zero. The power factor of load is
Which instrument needs creep compensation? 0.5
Dynamometer wattmeter
A dynamometer wattmeter is connected in ac
Assertion (A): When a wattmeter is used for low circuit. The measured power is average power
impedance loads, the pressure coil is connected
across the load. Reason (R): A wattmeter Which of these instruments is dynamometers
measures apparent power. A is true R is false type? Both (a) and (b)

Which formula shows a direct proportionality Which of the following are needed both for
between power and voltage? P = VI protection and metering? Instrument
transformers
Power is defined as: the rate at which energy is
used An induction wattmeter can be used for: 50 Hz
ac only
A polyphase wattmeter basically consists of two
wattmeters. The moving system of two In two wattmeter method of 3 phase power
wattmeters are common measurement, when does one wattmeter read
negative when power factor is less than 0.5
A dynamometer wattmeter is connected in ac
circuit. The reading will be average power
The power factor of a single phase load can be
calculated if instruments available are one
voltmeter, one ammeter and one wattmeter

The scale of a dynamometer is linear when used


as wattmeter

The resistance in the circuit of the moving coil


of a dynamometer wattmeter should be high

In 3 phase power measurement by two


wattmeter method, both wattmeters had equal
reading. The power factor of load is 1

For P = V2/R, a decrease in resistance should


produce: an increase in power

Which of the following methods can be used to


measure power in a single phase circuit without
using wattmeter? 3 and 4 only

Assertion (A): A low power factor wattmeter has


special constructional features to ensure
accurate measurement. Reason (R): Extension
of wattmeter range in dc circuit can be easily
done by using current and potential
transformer. A is true R is false

The torque in induction wattmeters due to:


eddy currents

The dynamometer principle can be used for


ammeter, voltmeter and wattmeter

Which one of the following effects is used in


measuring power? Induction

Which of the following statement is correct for


two wattmeters method of power
measurement in 3 phase circuit? When the two
wattmeter read equal and opposite, p.f. is
zero.