DG12-200 (12V200Ah)

DG (Deep Cycle GEL , 12 Volts ) series is pure GEL battery with 12 years
floating design life , it is ideal for standby or frequent cyclic discharge
applications under extreme environments. By using strong grids, high
purity lead and patented Gel electrolyte, the DG series offers excellent
recovery after deep discharge under frequent cyclic discharge use, and
can deliver 400 cycles at 100% DOD. Suitable for solar, CATV, marine , RV
Specification and deep discharge UPS, communication , and telecommunication , etc.
Cells Per Unit 6
Voltage Per Unit 12
o
Capacity 200Ah@20hr-rate to 1.75V per cell @25 C
Weight Approx. 60.0 Kg( Tolerance±1.5%)
Max. Discharge Current 2000 A (5 sec)
Internal Resistance Approx. 5.2 mΩ
o o
Operating Temperature Range Discharge: -40 C~60 C
o o
Charge:-20 C~50 C
o
Storage: -40 C~60oC

Normal Operating Temperature Range 25oC±5 oC


o
Float charging Voltage 13.6 to 13.8 VDC/unit Average at 25 C
Recommended Maximum Charging 40A
Current
o
Equalization and Cycle Service 14.2 to 14.4VDC/unit Average at 25 C
Self Discharge RITAR Valve Regulated Lead Acid (VRLA) batteries can be stored
o
for more than 6 months at 25 C. Self-discharge ratio less than 3%
o
per month at 25 C. Please charge batteries before using.
Terminal Terminal F10
Container Material A.B.S. UL94-HB, UL94-V0 Optional.

Dimensions
Unit: mm Dimension: 522(L)×240(W)×223(H)

Terminal F10

o
Constant Current Discharge Characteristics: A (25 C)(The capacity reaches the peak value after 5-20 cycles.)

F.V/Time 5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
9.60V 476.4 340.9 273.6 183.4 116.6 70.20 50.79 40.54 34.42 23.31 19.36 10.61
10.0V 462.6 324.4 268.0 181.8 116.1 69.67 50.59 40.35 34.22 23.12 19.17 10.42
10.2V 448.9 312.9 263.8 180.7 115.0 69.15 50.20 40.16 34.02 22.93 18.98 10.22
10.5V 407.8 292.2 254.1 177.9 113.9 68.62 50.01 39.79 33.61 22.75 18.80 10.00
10.8V 372.4 269.6 237.0 171.7 110.0 67.39 48.65 38.85 32.79 21.84 18.20 9.496
11.1V 321.6 243.7 215.0 162.4 104.5 64.40 46.50 36.97 31.38 20.91 17.66 8.937

Constant Power Discharge Characteristics: W (25 oC)(The capacity reaches the peak value after 5-20 cycles.)
F.V/Time 5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
9.60V 4927 3630 3010 2091 1347 827.4 605.9 483.2 410.6 278.4 231.3 127.2
10.0V 4830 3519 2962 2083 1344 823.1 604.6 482.6 409.6 277.0 229.8 125.0
10.2V 4775 3426 2928 2072 1334 818.1 601.9 481.6 408.2 275.2 227.8 122.7
10.5V 4398 3229 2826 2044 1322 812.2 599.6 477.1 403.3 272.9 225.6 120.4
10.8V 4052 3011 2643 1978 1284 801.8 583.3 466.2 393.4 262.1 218.5 113.9
11.1V 3600 2754 2406 1876 1229 772.0 558.1 443.7 376.5 251.0 211.9 107.2
All mentioned values are average values ( Tolerance ±2%) .
DG12-200 12V200Ah

Life characteristics of cyclic use Storage characteristic

100
120 Supplementary charge required
0℃ (Carry out supplementary charge
before use if 100% capacity is
100 80 requires)

Capacity (%)
10℃
Supplementary charge required
80 60
Capacity(%)

before use.
This supplementary charge will help
to recover the capacity and should
60 20℃ be made as early as possible.
100% 80% 50% 30% 15% 40 40℃ 30℃
D.O.D D.O.D D.O.D D.O.D D.O.D
Supplementary charge may often
40 fail to recover the capacity.
The battery should never be left
20 standing till this state is reached
20

0
Supplementary charge and storage
2 4 6 8 10 12 14 16 18 20 22 24 guidelines
0 400 800 1200 1600 2000 2400
Number of Cycle(Times) Storage Time (months)

Charge characteristic curve for cyclic use Discharge characteristic curve


15 120 0.24
Charge Volume 13

14 100 0.20
Charge Voltage
12
T erm inal V oltage (V )
C h a rg e V o lu m e (% )

C h a rg e C u rre n t (C A )

13 80 0.16
C h a rg e V o lta g e ( V )

① Discharge
100%(0.05CA×20h) 11
12 50%(0.05CA×10h) 60 0.12 0.05C
② Charge 0.16C 0.093C
Charge Voltage2.275V/C 0.35C
Charge Current0.1CA 10 0.62C
11 40 0.08
③ Temperature 25℃
3C 1C

10 20 0.04 9
Charge Current
0.6 1.2 3 6 12 30 1 2 5 10 20 24
9 0 0
4 min Hr
0 2 6 8 10 12 14 16 18 20 24 28
Charge Time(h) Discharge Time

Capacity Factors With Different Temperature


Battery Type -20℃ -10℃ 0℃ 5℃ 10℃ 20℃ 25℃ 30℃ 40℃ 45℃
GEL 6V&12V 50% 70% 83% 85% 90% 98% 100% 102% 104% 105%
Battery 2V 60% 75% 85% 88% 92% 99% 100% 103% 105% 106%
AGM 6V&12V 46% 66% 76% 83% 90% 98% 100% 103% 107% 109%
Battery 2V 55% 70% 80% 85% 92% 99% 100% 104% 108% 110%

Discharge Current VS. Discharge Voltage


Maintenance & Cautions
Final Discharge 1.75V 1.70V 1.60V
Vo ltage V /cell
Cycle service
Discharge (A) ≥1.0C
(A) ≤0.2C 0.2C< (A) <1.0C
Current (A)
※ Avoid battery over discharge, especially battery sereis connection use.
Charge the batteries at least once every six months,
o ※ Charged with recommend voltage, ensure battery can be full recharged.
if they are stored at 25 C.

Charging Method: In general, recharge capacity should be 1.1-1.15 times discharge capacity.

Constant Voltage -0.2Cx2h+14.4-14.7Vx24h,Max. Current 0.2C ※ Effect of temperature on cycle charge voltage: -4mV/℃/Cell.
Constant Current -0.2Cx2h+0.1Cx12h
※ There are a number of factors that will affect the length of cyclic service.
Fast -0.2Cx2h+0.2Cx6h

The most significant are depth of discharge, ambient temperature,


Bolt M5 M6 M8 discharge rate, and the manner in which the battery is recharged.
Terminal F3 F4 F13 F18 T25 T26 F8 F11 F12-1 F15 F5 F9 F10 F12 F14 F16
Generally specking, the most important factors is depth of discharge.
Torque 6~7N-m 8~10N-m 10~12N-m

SHEN ZHEN RITAR POWER CO.,LTD. Address: Rm405,Tower C, Huahan Building,Langshan Rd16, Nanshan District, ShenZhen, 518057, China
URL:www.ritarpower.com
Tel:+86-755-33981668 Fax:86-755-8347-5180 2015 - Version 0
SHENZHEN RITAR POWER CO.,LTD
No.9 Bldg.,Fuqiao 2 Industrial Area,Fuyong, Bao'an District,Shenzhen,518103,China
Tel: +86- 734-8539188 Fax: +86- 734-8595518 www.ritarpower.com

Warranty Letter

Shenzhen RITAR POWER CO., Ltd.(“Manufacturer”)warrants each Ritar-manufactured battery


sold by Manufacturer to be free of defects in material and workmanship for a the periods as
defined below from the date of purchase, as evidenced by the original receipt (the “Warranty
Period”). Within the Warranty period, subject to the exclusions listed below, Manufacturer will
replace the Battery free of charge if replacement is necessary due to defects in material or
workmanship. This Limited Warranty is limited to the original purchaser of the Battery, and is
not transferable to any other person or entity.

Product Warranty Time

RITAR Battery
RT series 1 years warranty
RA series 2 years warranty

MISUSE or DEVIATED TECHNICAL MANUAL USE NOT COVERED THIS WARRANTY,


Manufacturer has no obligation under this Limited Warranty with respect to any defects in or
damage to the Battery arising from any abuse or mishandling of the Battery any one of more of
the following:
* Neglect, such as improper fluid levels (under or over watering), damage from shipping, loose
wiring, or rusted or corroded hardware;
* Misapplied or improperly sized Battery for the application;
* Batteries exposed to excessive heat or cold temperatures;
* Batteries that have had the manufacturing date codes destroyed or tampered with;
*Breakage, freezing, explosion, fire, wreckage, overcharging, undercharging, over-discharging,
charging or installing in reverse polarity, improper maintenance, improper storage, or addition
of any chemical or solution other than approved water, or failure to improperly install the
Battery.

During the warranty period, Shenzhen Ritar Power Co. Ltd is responsible to repair the battery
or send new replacements with next new order shipment together for manufacturing claim
mention above only.

HOW TO MAKE A CLAIM:

To make a claim under this Limited Warranty, please submit a completed “Battery Test sheet”
SHENZHEN RITAR POWER CO.,LTD
No.9 Bldg.,Fuqiao 2 Industrial Area,Fuyong, Bao'an District,Shenzhen,518103,China
Tel: +86- 734-8539188 Fax: +86- 734-8595518 www.ritarpower.com

to Manufacturer. Batteries will be eligible for warranty only after verification of the Battery Test
Sheet by Manufacturer Tech Support determines that a manufacturing defect exists.
Manufacturer may request Batteries claimed for warranty be returned to Manufacturer for
inspection from time to time and, if it is determined that any such Batteries do not have a
Defect, the warranty claim for such Batteries will be denied.

WARRANTY DISCLAIMER:

This limited warranty is in lieu of, and manufacturer disclaims and excludes, all other
warranties, whether statutory, express or implied warranties, including, without limitation, any
warranty of merchantability or fitness for a particular purpose, to the warranty period.

Manufacturer’s exclusive liability for breach of any warranty on the battery shall be to replace
the battery within the warranty period in accordance with the terms of this limited warranty .In
no event shall manufacturer be liable for any loss or damages of any other kind. Whether
direct, incidental, consequential, exemplary, special or otherwise, including any lost profits or
removal, shipping, or installation expenses.

LEGAL RIGHTS:

This Limited Warranty gives you specific legal rights, and you may also have other rights which
may vary from country to country or state to state. Some countries and states do not allow any
limitation on implied warranties or the exclusion or limitation of incidental of incidental or
consequential damages, so the above limitations may not apply to you.

Sincerely, Acknowledgement:

Shenzhen RITAR POWER CO., Ltd.

Das könnte Ihnen auch gefallen