Close the bench flow control valve, switch on the service pump then
gradually open the bench flow control valve. When the water level in
Install one of the two orifices in the fitting at the right hand side of
the header tank reaches the top of the overflow tube, adjust the
the header tank using the two securing screws supplied. Ensure
bench flow control valve to give a water level of 2 to 3mm above the
that the 'O' ring seal is fitted between the orifice and the tank.
overflow level. This will ensure a constant head and produce a steady
flow through the orifice.
If necessary adjust the frame so that the row of The volume flowrate through the orifice can be
needles are parallel with the jet but located just determined by intercepting the jet using the
behind it by 1 or 2mm. This will avoid disturbing the measuring cylinder supplied in conjunction with a
jet but minimize errors due to parallax. stopwatch (not supplied).
The F1-17 Orifice and Free Jet Flow apparatus is ready for
use.