Sie sind auf Seite 1von 58

Split Type Air Conditioner

ENGINEERING DATA
MODELS:
AS122ALMBA+AU122ABMEA(HSU-12LF03)
(10102884600,10102884700)
AS122AMMCA+AU122AKMBA(HSU-12LL03)
(10102882400,10102882500)
AS122AMMCA+AU122AKMEA(HSU-12LM03)
(10102884800,10102884900)
AS122ALMAA+AU122AKMBA(HSU-12LP03)
(10102882600,10102882700)
AS122AKMAA+AU122AKMBA(HSU-12LR03)
(10102882800,10102882900)
AS122AKMBA+AU122AKMBA(HSU-12LY03)
(10102883000,10102883100)
AS122AMABA+AU122AKABA(HSU-12RN03)
(10102883200,10102883300)
AS122ALABA+AU122AKABA(HSU-12RP03)
(10102883400,10102883500)
AS122AKABAA+AU122AKABA(HSU-12RR03)
(10102883600,10102883700)
AS122AKABAA+AU122AKABA(HSU-12RY03)
(10102883800,10102883900)
AS122AKABAA+AU122AKABA(HSU-12RS03)
(10102893000,10102893100)

Content

2.specifications-------------------------------------------------------------------
3.Curves of performance -----------------------------------------------------
4.Description, dimension and function of main components
and accessories ----------------------------------------------------------------
5.knock-down drawings--------------------------------------------------------
6.remote controller functions conversion ----------------------------------
7.brief introduction to electrical control functions-----------------------
8.refrigerating cycle diagram-----------------------------------------------
9.Noise level test chart and air velocity distribution--------------------
10.installation and accessory parts------------------------------------------
Description of product model coding and series instroduction

1
Description of product model coding and series instroduct

Introductory Remarks
A. Description of coding rules of unit model
Coding rules and descriptions of new models are as follows:
Indoor unit model and outdoor unit model of exported air conditioners shall be separately worked out in 10 digits
combining English letters and Arabian numbers. The composition and representation are as follows:

1 2 3 4 5 6 7 8 9 10

Climate type:A,B
Develop. serial no.:A,B,C
Product category:A,B,D,M
Appearance feature:A,B,C,D,E
Product series:A,B,C,D
Applicable voltage:1,2,3,4
Product specification in two digits
Structural feature:S(wall-mounted),W(window type),P (cabinet type)
Product type All is A AIR CONDITIONER

E.g.: in , AS122AKMHA "A" represents air conditioner; "S" means wall mounted indoor unit; "12" indicates heating capacity
of 12000BTU/h; "2" means applicable voltage of 220-240V/50Hz; "A" represents single split system; "K" is for appearance
characteristics; "M" means heat pump type and refrigerant of R22; "H" is development serial number; "A" representsclimate type.
In , AU122ABMEA "A" represents air conditioner; "U" means wall mounted outdoor unit; "12" indicates heating capacity
of 12000BTU/h; "2" means applicable voltage of 220-240V/50Hz; "A" represents single split system; "B" is for appearance
characteristics; "M" means heat pump type and refrigerant of R22; "E" is development serial number; "A" representsclimate type.

B.Another model indentification

1 3 4 5 6 7 8 9 10 (B)

Variable
frequence type
The type of power supply
Developing sequence
C-cooling only
Function code H-heat pump
e-electric aided heating
Nominal cooling capacity (BTU/h)with the first two
numbers based on thousand unit
The structure code of indoor & outdoor unit
H-Abbreviation of Haier
Description of product model coding and series instroduct

Examples:
HSU-12LM03,It represents wall-mounted spilt type room air contioner(variable-frequency type) .
The cooling capacity is 12,000BTU/h,and the power supply is 220V/50Hz ."A" means the improvement.
1.Standard Situation/conditions

operating indoor air status outdoor air status


NO.
condition DB C WB C DB C WB C
1 Nominal cooling 27 19 35 24
2 Nominal heating 20 ---- 7 6
3 Nominal electrical
---- ---- ---- ----

C series brief introduction


1.comfortable: wide-angle airflow.
The vertical dual-flap and horizontal wide-angle louvers ensure the cool (warm)
air reaches every corner of the room.
2.Durable and rustproof plastic panel.
Outdoor unit equipped with plastic casing is rust and corrosion-proof as well as
weather-resistant.
3.Health air purifying
An air purifying filter with deodorizing and disinfecting functions keep the air
clean and users healthy.
4.Quiet operation
Fan With Random-pitched Blades.
Random-pitched blades help reduce operating noise while maintaining a high
airflow rate.
5.Energy efficient
The design of inner-grooved copper tube greatly increases the refrigerant contact
area and the efficiency of cooling/heating functions.
6. Convenience
Auto restart and washable panel:
The grille can be removed easily and washed when necessary. Even if the power
fails when the unit is operating, the unit will automatically return to the operating
settings in use before the power failure when power is restored.

3
Description of product model coding and series instroduct
Specifications
SPECIFICATIONS
Specification:
AS122ALMBA+AU122ABMEA
(HSU-12LF03)
AS122AMMCA+AU122AKMBA
(HSU-12LL03)
AS122AKMBA+AU122AKMEA
Model: (HSU-12LM03) Appearance color
AS122ALMAA+AU122AKMBA White/White
(indoor/outdoor):
(HSU-12LP03)
AS122AKMAA+AU122AKMBA
(HSU-12LR03)
AS122AMMBA+AU122AKMBA
(HSU-12LR03)
Cooling capacity: 3450W Heating capacity: /
Cooling coefficient: 2.78 Heating coefficient: /
cooling Power input: 1240W Heating power: /
Moisture removal 1.5X10-3m3/h Frequency range 50Hz
Operating voltage range 1PH, 220-230V~,50Hz Refrigerant type R22
Operating temp. range -7 C-43 C
O O
Air sending angle/distance 60 O

Cross flow fan(indoor unit)


Variation of temp. adjust +1 C O
Fan type/quantity
Axial fan(outdoor unit)
Climate type: T1 Class of electric shock I
Indoor unit noise outdoor unit noise
41/38/33dB(A) 49dB(A)
(cooling) (cooling)
Indoor unit noise outdoor unit noise
(heating) 42/39/34dB(A) (heating) 50dB(A)

net dimensions 848 x260x315mm net dimensions 876x363X625mm


Packaging dimensions Packaging dimensions
863x275x330mm 891X378X640mm
(indoor unit) (outdoor unit)
weight(indoor unit ) 7.6/10.6(net/gross)kg Piling layers for indoor/outdoor 8/4
unit
Max. mounting height 5m 36/41(net/gross) kg
Outdoor unit net/gross weights:
difference:
R22 1150g Current entering side
Refrigerant charge (indoor/outdoor) indoor

Frequency of filter cleaning Once/2 weeks Max. refrigerant charge 1230g


Compressor model QXR-23C(F) Compressor manufacturer HUARUN
Compressor oil charge 320cc Compressor protector type -------------
Maxi. length of connecting 10m model of 4-way valve:
pipe: -------------
Cap. tube type muffle
TP2Y copper tube Length/diameter of drain hose 2000mm/O15.6mm
model:
Fan speed: (r/min) 1350/1100/920(indoor) Type/size of evaporator and Internal treaded pipe
760(outdoor) condenser O7/O12.7mm
Max. operating pressure Max. operating pressure at cool
2.65MPa side: 2.65MPa
warm side:
Appearance features Indoor unit:plastic:Outdoor
cut-off valve: 1/4”,1/2” unit: iron
SPECIFICATIONS

Specification:
AS122AMABA+AU122AKABA
(HSU-12RN03)
AS122ALABA+AU122AKABA Appearance color
(HSU-12RP03) White/White
Model: AS122AKAAA+AU122AKABA (indoor/outdoor):
(HSU-12RR03)
AS122AMACA+AU122AKABA
(HSU-12RY03)
AS122ADABA+AU122AKABA
(HSU-12RS03)
Cooling capacity: 3450W Heating capacity: 3950W
Cooling coefficient: 2.56 Heating coefficient: 2.86
cooling Power input: 1350W Heating power: 1380W
Moisture removal 1.5X10-3m3/h Frequency range 50Hz
Operating voltage range 1PH, 220-230V~,50Hz Refrigerant type R22
Operating temp. range -7 C-43 C
O O
Air sending angle/distance 60 O

Cross flow fan(indoor unit)


Variation of temp. adjust +1 C O
Fan type/quantity
Axial fan(outdoor unit)
Climate type: T1 Class of electric shock I
Indoor unit noise outdoor unit noise
44/40/36dB(A) 53dB(A)
(cooling) (cooling)
Indoor unit noise outdoor unit noise
(heating) 45/41/37dB(A) (heating) 54dB(A)

net dimensions 848 x260x315mm net dimensions 876x363x625mm


Packaging dimensions Packaging dimensions
863x275x330mm 891x378x640mm
(indoor unit) (outdoor unit)
weight(indoor unit ) 7.6/10.6(net/gross)kg Piling layers for indoor/outdoor 8/4
unit
Max. mounting height 5m 37/42(net/gross) kg
Outdoor unit net/gross weights:
difference:
R22 1150g Current entering side
Refrigerant charge (indoor/outdoor) indoor

Frequency of filter cleaning Once/2 weeks Max. refrigerant charge 1230g


Compressor model QX-24A(F) Compressor manufacturer HUARUN
Compressor oil charge --------- Compressor protector type ----------
Maxi. length of connecting 10m model of 4-way valve:
pipe: ----------
Cap. tube type muffle
TP2Y copper tube Length/diameter of drain hose 2000mm/O15.6mm
model:
Fan speed: (r/min) 1350/1100/920(indoor) Type/size of evaporator and Internal treaded pipe
760(outdoor) condenser O7/O12.7mm
Max. operating pressure 2.65MPa Max. operating pressure at cool
warm side: side: 2.65MPa
Indoor unit:plastic:Outdoor
cut-off valve: 1/4”,1/2” Appearance features unit: iron
Curves of performance
Curves of performance

AS122ALMBA+AU122ABMEA(HSU-12LF03) AS122ALMAA+AU122AKMBA(HSU-12LP03)
AS122AMMCA+AU122AKMBA(HSU-12LL03) AS122AKMAA+AU122AKMBA(HSU-12LR03)
AS122AKMBA+AU122AKMEA(HSU-12LM03) AS122AMMBA+AU122AKMBA(HSU-12LR03)

Compressor: QXR-23C(F)
A B C D E
QXR-23C(F) Condensing temp OC 40.5 45 50 54.4 60
1PH,50Hz,220V
Rerurn gas temp OC 35 35 35 35 35
30uF/400VCA
32.2 36.7 41.7 46.1 51.7
R22
Ambient temp OC 35 35 35 35 35

7.0
60.0
6.5
54.4
6.0
50.0
5.5
curent (A)

45.0
40.5

4.5

Condensing temp OC
2000

1800
input (W)

1600
60.0
1400
54.4
1200 50.0
45.0
1000 40.5

5500

4500 40.5
capacity (W)

45.0
50.0
54.4
3500 60.0

2500

1500

-10 -5 0 5 10
evaporating temp C O
Curves of performance

AS122AMABA+AU122AKABA(HSU-12RN03)
AS122ALABA+AU122AKABA(HSU-12RP03)
AS122AKAAA+AU122AKABA(HSU-12RR03)
AS122AMACA+AU122AKABA(HSU-12RY03)
AS122ADACA+AU122AKABA(HSU-12RS03)
Compressor: QX-24A(F)

QX-24A(F) A B C D E
Condensing temp OC 40.5 45 50 54.4 60
1PH,50Hz,220V

35uF/400VCA Rerurn gas temp OC 35 35 35 35 35

R22 32.2 36.7 41.7 46.1 51.7


Ambient temp OC 35 35 35 35 35

7.5
60.0
7.0
curent (A)

54.4
6.5
50.0
6.0
45.0
5.5 40.5

5.0

Condensing temp OC
1500 60.0
54.4
input (W)

1300 50.0
45.0
1100 40.5

900

6000
capacity (W)

5000 40.5
45.0
50.0
4000 54.4
60.0

3000

2000

-10 -5 0 5 10
evaporating temp C
O
Curves of performance

B. curves of performance
Adjust temperature range:-7OC ~ 43OC
Indoor
Cooling DB/WB( OC)

130 31/22
29.2/15
C a p a c ity(% ) 120 29/17
25/17.5
110 23/16
21/14.5
100 19/12.5
90
80
70

130
120
In p u t(% )

Indoor
110 DB/WB( OC)
100
31/22
90 29.2/15
29/17
80 25/17.5
23/16
70 21/14.5
60 19/12.5
20 21 25 30 35 40 45 50

Outdoor DB(OC)

Heating
Indoor
DB(OC)
130

120
C a p a c ity (% )

110

100

90

80

70

130

120
In p u t(% )

110

100

90

80
70

60
-5/-6 0/-2 5/3 10/7.5 15/12 20 25 30 35
Outdoor DB/WB( C)
O
Description,dimension and function of main
components and accessories
I. NET DIMENSION FOR INDOOR UNIT
NET DIMENSION FOR INDOOR UNIT
NET DIMENSIONS FOR INDOOR UNIT
Indoor unit

MODELS:AS122AMMCA+AU122AKMBA(HSU-12LL03)
AS122AMABA+AU122AKABA(HSU-12RN03)

795 182
265

Indoor unit
MODELS:AS122ALMBA+AU122ABMEA(HSU-12LF03)
AS122ALMAA+AU122AKMBA(HSU-12LP03)
AS122ALABA+AU122AKABA(HSU-12RP03)

795 182
265
NET DIMENSION FOR INDOOR UNIT
NET DIMENSIONS FOR INDOOR UNIT
Indoor unit

MODELS:AS122AMMBA+AU122AKMBA(HSU-12LY03)
AS122AMACA+AU122AKMBA(HSU-12RY03)

795 182
265

Indoor unit
MODELS:AS122AKMBA+AU122ABMEA(HSU-12LM03)
AS122AKMAA+AU122AKMBA(HSU-12LR03)
AS122AKAAA+AU122AKABA(HSU-12RR03)

795 182
265

MODELS:AS122ADACA+AU122AKMBA(HSU-12RS03)

795 182
265
II. NET DIMENSION FOR OUTDOOR UNIT
NET DIMENSION FOR INDOOR UNIT
NET DIMENSIONS FOR OUTDOOR

MODELS:
AS122ALMBA+AU122ABMEA(HSU-12LF03)
AS122AKMBA+AU122AKMEA(HSU-12LM03)

540

68
140 500 123 55 67
15
780 62
256
845 286

MODELS:
AS122AMMCA+AU122AKMBA(HSU-12LL03) AS122AMABA+AU122AKABA(HSU-12RN03)
AS122ALMAA+AU122AKMBA(HSU-12LP03) AS122ALABA+AU122AKABA(HSU-12RP03)
AS122AKMAA+AU122AKMBA(HSU-12LR03) AS122AKAAA+AU122AKABA(HSU-12RR03)
AS122AMMBA+AU122AKMBA(HSU-12LR03) AS122AMACA+AU122AKABA(HSU-12RY03)
AS122ADABA+AU122AKABA(HSU-12RS03)
KNOCK-DOWN DRAWINGS FOR INDOOR UNIT

AS122AMMCA+AU122AKMBA(HSU-12LL03)
AS122ALMAA+AU122AKMBA(HSU-12LP03)
AS122AKMAA+AU122AKMBA(HSU-12LR03)
AS122AMMBA+AU122AKMBA(HSU-12LY03)
No. Name of part Part specialized code QTY. Easily remark
damaged
1 Controller assy. 0010801555 1
2 PCB(main controller) 0010401867 1 Y
3 PCB(receiver) 001A3900058 1 Y
4 Motor cover 001A1431372 1
5 Sensor 001A3900059 1 Y
6 Transformer 001A3800002 1 Y
7 Terminal block 001A4000091 1
8 Electricity power cord ------------- 1
9 Front panel assy. 001A1232074 1
10 Front grille (1) 1
11 Rear case assy. 001A0100206 1
12 Service cover 001A1431371 1
13 Motor 001A3000052 1 Y
14 Fan 001A2335028 1
15 Bearing 001A0300005 1
16 Drain pan 001A0900107 1
17 Swing motor 001A3000072 1 Y
18 Flap 001A1232077 1
19 Drain hose 001A0900011 1
20 evaporator 0010702158 1
001A2400060/001A24
21 Air filter 00061 1 /1
22 Mounting plate 001A1301216 1
23 Piping support 001A1431368 1
24 Piping clamp 001A1431038 1
25 Remote controller 001A3400078 1 Y
26 Drain hose 001A1434039 1
NO. Models Part specialized code
HSU-12LL03 001A1232075
HSU-12LP03 001A1232303
(1) HSU-12LR03 001A1232304
HSU-12LY03 0010200293
22

11

15

14

23

20 4
13 1

8
5
16 2
6
7
21
19

9 17 3
18

12

25

10 26 24
KNOCK-DOWN DRAWINGS FOR INDOOR UNIT
KNOCK-DOWN DRAWINGS FOR INDOOR UNIT

No. Name of part Part specialized code QTY. Easily damaged remark
components(Y/N)
1 Side panel assembly 0010800675 1
2 Front grille 0010200914 1
3 Screw 001A5002070 1
4 Rings 001A14361055 1
5 Screw 001A5002116 4
6 Nut 001A5102021 1
7 Axial fan 001A2300099 1
8 Screw 001A5002115 4
9 Motor 001A3000289 1 Y
10 Panel for ice 001A1301869 1
11 Screw 001A5002115 4
12 Motor support 001A1301868 1
13 Heat exchanger 001A0400217 1
14 Support for electric box 001A1301866 1
15 Support for stead 001A1301877 1
16 Panel 001A13011267 1
17 Clamp 001A5745046 2
18 Clamp for fix 001A1301880 1
19 Capacitor for motor 001A3600007A 1
20 Clamp for capacitor 001A5701014 1
21 Capacitor for compressor 001A3600032 1
22 Clamp for wires 001A5745045 1
23 Electric box bottom 001A1301872 1
24 Terminal block 001A4000092 1
25 Support for terminal block 001A1301879 1
26 Top panel 0010800674 1
27 Panel for electric box 001A1301873 1
28 Back grille 001A14361057 1
29 Separating plate 001A1301867 1 Y
30 Cushion 001A17561385 1
31 Cushion 001A17561384 1
32 Sound insulation cushion 001A1762575A 1
33 Pipe assembly ----------
34 Valve set 001A1301871 1
35 Screw 001A5002001 4
36 Valve 001A2500158 1
37 Valve 001A2500159 1
38 Sound insulation cushion 001A1762207 1
39 Compressor 001A2000207 1 Y
40 Terminal cover 001A1440763 1
41 Rubber cushion 001A1754935 1
42 Nut 001A5102050 3
43 Rubber stem 001A14511170 3
44 Nut 001A5002063 3
45 Bottom plate 001A1101212 1
46 Support 001A1301876 2
47 Wirs group 001A4400750 1
KNOCK-DOWN DRAWINGS FOR OUTDOOR UNIT

AS122AMMCA+AU122AKMBA(HSU-12LL03)
AS122ALMAA+AU122AKMBA(HSU-12LP03)
AS122AKMAA+AU122AKMBA(HSU-12LR03)
AS122AMMBA+AU122AKMBA(HSU-12LY03)
26

27

28

33

38
34

37
35
36
40

39
41
42
32

44
29

43
21 22 24

25

45
20
18 19

23

46
17

31
16

30
15

14

10
13

11
9
12

48
7

1
47
5
6
4

2
3
KNOCK-DOWN DRAWINGS FOR INDOOR UNIT

AS122ALMBA+AU122ABMEA(HSU-12LF03)
AS122AKMBA+AU122ABMEA(HSU-12LM03)

No. Name of part Part specialized code QTY. Easily damaged remark
components(Y/N)
1 Controller assy. 0010801555 1
2 PCB(main controller) 0010401867 1 Y
3 PCB(receiver) 001A3900058 1 Y
4 Motor cover 001A1431372 1
5 Sensor 001A3900059 1 Y
6 Transformer 001A3800002 1 Y
7 Terminal block 001A4000091 1
8 Electricity power cord ------------- 1
9 Front panel assy. 001A1232074 1
10 Front grille 1 1
11 Rear case assy. 001A0100206 1
12 Service cover 001A1431371 1
13 Motor 001A3000052 1 Y
14 Fan 001A2335028 1
15 Bearing 001A0300005 1
16 Drain pan 001A0900107 1
17 Swing motor 001A3000072 1 Y
18 Flap 001A1232077 1
19 Drain hose 001A0900011 1
20 evaporator 0010702158 1
21 Air filter 001A2400060/ 1 /1
001A2400061
22 Mounting plate 001A1301216 1
23 Piping support 001A1431368 1
24 Piping clamp 001A1431038 1
25 Remote controller 001A3400078 1 Y
26 Drain hose 001A1434039 1

NO. Models Part specialized code


HSU-12LF03 001A1232303
1 HSU-12LM03 001A1232304
22

11

15

14

23

20 4
13 1

8
5
16 2
6
7
21
19

9 17 3
18

12

25

10 26 24
KNOCK-DOWN DRAWINGS FOR INDOOR UNIT
KNOCK-DOWN DRAWINGS FOR OUTDOOR UNIT
AS122ALMBA+AU122ABMEA(HSU-12LF03)
AS122AKMBA+AU122ABMEA(HSU-12LM03)

Name of part Easily damaged


No. Part specialized code QTY. components(Y/N) remark

1 Front grille 1436043A 1


2 Front panel 001A1101077 1
3 Nut 001A5102021 1
4 Fan 001A2331030A 1
5 Motor support 0010100418 1
6 Heat exchanger 001A0400016 1
7 Back grille 001A1101013 1
8 Top panel 001A1101010 1
9 Discharge pipe 001B2111147 1
10 Capillary tube assy. 001B0702302 1
11 Screw 001A5002001 1
12 Stop valve 0012500013 1
13 Stop valve 0012500012 1
14 Nut 001A5102004 1
15 Terminal cover 001A1440763 1
16 Protector 001A3100009 1
17 Nut 001A5102050 3
18 Compressor 001A2000006 1 Y
19 Rubber cushion 001A1734936 1
20 Cushion 001A1762105 1
21 Suction pipe 001B2111146 1
22 Terminal cover 001A4000092 1
23 Capacitor for comp. 001A3600032 1 Y
24 Electric box 001A1301023 1
25 Wires 001A4400389 1
26 Cushion 001A1742109 1
27 Separating plate 001A1301022 1
28 Service cover 001A1436042 1
29 Bottom plate assy. 001A0100029 1
30 Motor 001A3000075 1 Y
KNOCK-DOWN DRAWINGS FOR OUTDOOR UNIT

AS122ALMBA+AU122ABMEA(HSU-12LF03)
AS122AKMBA+AU122ABMEA(HSU-12LM03)

10
9

19
20
18
15
16
17
14
23

24

25
21
22
7
6

29
8

30 27
26

28
5

4
3
2

1
KNOCK-DOWN DRAWINGS FOR INDOOR UNIT
AS122AMABA+AU122AKABA(HSU-12RN03)
AS122ALABA+AU122AKABA(HSU-12RP03)
AS122AKAAA+AU122AKABA(HSU-12RR03)
AS122AMACA+AU122AKABA(HSU-12RY03)
AS122ADABA+ AU122AKABA(HSU-12RS03)

Easily damaged
No. Name of part Part specialized code QTY. components(Y/N) remark
1 Controller assy. 0010801556 1 Y
2 PCB(main controller) 0010401868 1 Y
3 PCB(receiver) 001A3900058 1 Y
4 Motor cover 001A1431372 1
5 Sensor 001A3900059 1 Y
6 Transformer 001A3800002 1 Y
7 Terminal block 001A4000091 1
8 Electricity power cord ------------- 1
9 Front panel assy. 001A0100944 1
10 Front grille (1) 1
11 Rear case assy. 001A0100206 1
12 Service cover 001A1431371 1
13 Motor 001A3000052 1 Y
14 Fan 001A2335028 1
15 Bearing 001A3000052 1
16 Drain pan 001A0900107 1
17 Swing motor 001A3000072 1 Y
18 Flap 001A1232077 1
19 Drain hose 001A0900011 1
20 evaporator 0010702158 1
001A2400060/0
21 Air filter 01A2400061 1 /1
22 Mounting plate 001A1301216 1
23 Piping support 001A1431368 1
24 Piping clamp 001A1431038 1
25 Remote controller 001A3400078 1 Y
26 Drain hose 001A1434039 1

NO. Models Part specialized code


HSU-12RN03 001A1232075
HSU-12RP03 001A1232303
(1)
HSU-12RR03 001A1232304
HSU-12RY03 0010200293
HSU-12RS03 0010201363
KNOCK-DOWN DRAWINGS FOR INDOOR UNIT
AS122AMABA+AU122AKABA(HSU-12RN03)
AS122ALABA+AU122AKABA(HSU-12RP03)
AS122AKAAA+AU122AKABA(HSU-12RR03)
AS122AMACA+AU122AKABA(HSU-12RY03)
AS122ADABA+AU122AKABA(HSU-12RS03)

1
23
22

6
13

3
2

12
7

24
19
4

17

25
11

15

14

26
18
20

16

10
21
KNOCK-DOWN DRAWINGS FOR OUTDOOR UNIT
AS122AMABA+AU122AKABA(HSU-12RN03) AS122ADABA+AU122AKABA)HSU-12RS03)
AS122ALABA+AU122AKABA(HSU-12RP03)
AS122AKAAA+AU122AKABA(HSU-12RR03)
AS122AMACA+AU122AKABA(HSU-12RY03)
Easily damaged remark
No. Name of part Part specialized code QTY.
components(Y/N)
1 Side panel assembly 0010800675 1
2 Front grille 0010200914 1
3 Screw 001A5002070 1
4 Rings 001A14361055 1
5 Screw 001A5002116 4
6 Nut 001A5102021 1
7 Axial fan 001A2300099 1
8 Screw 001A5002115 4
9 Motor 001A3000289 1 Y
10 ----------- ------
11 Screw 001A5002115 4
12 Motor support 001A1301868 1
13 Heat exchanger 0010702316 1
14 Support for electric box 001A1301866 1
15 Support for stead 001A1301877 1
16 Panel 001A13011267 1
17 Clamp 001A5745046 2
18 Clamp for fix 001A1301880 1
19 Capacitor for motor 001A3600007A 1 Y
20 Clamp for capacitor 001A5701014 1
21 Capacitor for compressor 001A3600021 1 Y
22 Clamp for wires 001A5745045 1
23 Electric box bottom 001A1301872 1
24 Terminal block 001A4000092 1
25 Support for terminal block 001A1301879 1
26 Top panel 0010800674 1
27 Panel for electric box 001A1301873 1
28 Back grille 001A14361057 1
29 Separating plate 001A1301867 1
30 Cushion 001A17561385 1
31 Cushion 001A17561384 1
32 Sound insulation cushion 001A1762393A 1
33 Pipe assembly 0010702318 1
34 Valve set 001A1301871 1
35 Screw 001A5002001 4
36 Valve 0010702449 1
37 Valve 0010702450 1
38 ---------------- ---------------- 1
39 Compressor 001A2000206 1 Y
40 Terminal cover 001A1440763 1
41 Rubber cushion 001A1754935 1
42 Nut 001A5102050 3
43 Rubber stem 001A14511170 3
44 Nut 001A5002063 3
45 Bottom plate 001A1101212 1
46 Support 001A1301876 2
47 Wirs group 001A4400750 1
KNOCK-DOWN DRAWINGS FOR OUTDOOR UNIT
AS122AMABA+AU122AKABA(HSU-12RN03)
AS122ALABA+AU122AKABA(HSU-12RP03)
AS122AKAAA+AU122AKABA(HSU-12RR03)
AS122AMACA+AU122AKABA(HSU-12RY03)
AS122ADABA+AU122AKABA(HSU-12RS03)
26

27

28

33

38
34

37
35
36
40

39
41
42
32

44
29

43
21 22 24

25

45
20
18 19

23

46
17

31
16

30
15

14

10
13

11
9
12

48
7

1
47
5
6
4

2
3
1 3

2
1 3

2
1 3

2
Pi

Pi...Pi Pi
Brief introduction to electrical control functions
Brief introduction to electrical control functions

1. Introduction to electrical control function


Including brief introduction to air conditioners of series models and electric
control function.
Brief introduction to electric control function
(1) Automatic running (applicable to fan-coil model)
When the running mode is turned to automation after starting the system, the
system will first determine the running mode according to the current room
temperature and then will run according to the determined mode. Tr in the following
selection conditions means room temperature, Ts means setting temperature, Tp
means temperature of indoor coil pipe

a. Tr>23OC running refrigerating mode Ts=26 OC


b. Tr<23OC running heating mode Ts=26OC

After turning to the automation mode, the running mode can be switched
between refrigerating mode, fan mode and heating mode according to the change
of the indoor ambient temperature. But the automatic conversion between
refrigerating mode and heating mode must be conducted after 15 minutes.

(2) Indoor temperature control

Compressor OFF
Heating Compressor ON
-1 +1 Compressor OFF

Refrigerating
Setting temperature -1 +1

Setting temperature

(3) Dehumidification running


The compressor, outdoor fan and indoor fan will run as per the following
working pattern so as to realize the refrigerating running of
dehumidification:
a.Tr> Ts+2OC, compressor, outdoor fan run continuously, indoor fan runs as
per setting wind speed (State 1);
b.Ts+2OC>Tr>Ts, compressor, outdoor fan run intermittently with 10 minutes
ON, 6 minutes OFF. (Compressor and outdoor fan are synchronous)
indoor fan runs in fixed lower wind speed, and will cease at the stand-
by time of 3 minutes (State 2)
c.Tr <Ts, compressor, outdoor fan ceases, indoor fan runs in lower wind
speed. (State 3)
Brief introduction to electrical control functions

State1

State2
State3

Ts-1 Ts Ts+2 Ts+3

(4) Warm start (preventing cold wind when heating running begins,
applicable to fan-coil model))
When heating running begins, indoor fan will conduct the following fan
control:
a.If the temperature of indoor coil pipe is >23O C, start lower wind
speed;
b.If the temperature of indoor coil pipe is >38OC or the running time
of compressor> 4 minutes, turn to setting wind speed.

(5) Control of indoor fan under heating OFF state (applicable to fan-coil
model)
Under heating state, the compressor will cease; if the indoor coil pipe’s
temperature Tp>23 O C, indoor fan will run in lower wind speed.

(6) Defrosting control (applicable to fan-coil model)


(1).Defrosting beginning condition:
a.After the state of Tp-Tr<18OC is continued for 5 minutes, the
accumulated running time of the compressor exceeds 45
minutes, the continuous running time of the compressor exceeds
20 minutes;
b.The accumulated running time of the compressor exceeds 3
hours, the continuous running time of the compressor exceeds
20 minutes, indoor
unit’s Tp <42O C;
c.The continuous running time of the compressor exceeds 20
minutes, the temperature of indoor coil pipe decreases 1O C
every 6 minutes, which lasts for more than 3 times, indoor unit’s
Tp <42OC;
d.When the indoor unit is in the state of overload protection and
the outdoor unit ceases, when the rerunning time of outdoor
unit exceeds10 minutes, the accumulated running time of the
compressor exceeds 45 minutes, the continuous running time
of the compressor is over 20 minutes, andTp <42OC.
Defrosting will begin if one of the above conditions is met.

(2).Defrosting finishing condition:


a . If the defrosting time exceeds 9 minutes, the original heating
state will be resumed;
b. If the current of outdoor unit’s compressor exceeds 5.8 A (different
models have different currents); defrosting will be finished if either
a or b is met.
Brief introduction to electrical control functions

Note: Sequence of defrosting actions:


9 minutes
Compressor ON
OFF

Four-way value ON
OFF

Outdoor fan ON
OFF
55s 55s
1min 1min

(7) Freezing prevention function


Under refrigerating and dehumidifying state, the air conditioner will
control the outdoor fan as per the temperature Tp of the indoor coil
pipe according to the following conditions:
Zone of return deference
Compressor,outdoor fan OFF after 5 minutes Fan,compressor ON

-1 7 Tp(OC)
(8) 3 minutes stand-by time
When the compressor ceases due to the sensor OFF, unit On or OFF
or fault, it will maintain pause for 3 minutes.

(9) Overload protection during heating running


1.Temperature protection of indoor coil pipe: Under heating state, the
air conditioner will control the running of the fan as per the temperature
Tp of the indoor coil pipe and according to the following conditions:
a.65OC<Tp, outdoor fan ceases; Tp<60OC, outdoor fan resumes;
the time from ceasing to resuming is about 45 seconds;
b.72OC<Tp, outdoor fan of compressor ceases after 5 seconds;
Tp<64OC, compressor resumes after 3 minutes.
2.Current protection (different models have different protection currents):
a. When 5.8A <current of compressor, outdoor fan ceases; current
of compressor <5A, outdoor fan resumes;
b. When 10 A<current of compressor, compressor ceases.

(10) Compensatory function of power failure


If the unit is suddenly off during running due to power failure, or closed
for maintenance or troubleshooting, it will restart to run after the power
resumes with the original condition before the unit is off
Brief introduction to electrical control functions

Note: 1. Function setting: Pressing the SLEEP button on the remote control
unit for 10 times until hearing 4 sounds from the buzzer on the
panel.
2. Memory content: Running mode, setting wind speed, setting
temperature, sleep state, flap state.
3. Cancellation of function: Pressing the SLEEP button on the
remote control unit for 10 times until hearing 2 sounds from the
buzzer on the panel.

(11) Trial run function


When the air conditioner is in OFF state, press the emergency switch
for 5 seconds till hearing 2 sounds of click from the buzzer, then the
air conditioner will turn to the trial run state. The unit will run in the
refrigerating mode and the indoor fan will run in high wind speed mode.

(12) Emergency running mode


When the air conditioner is in stand-by state, press the emergency
switch till hearing a sound from the buzzer, then the air conditioner
will turn to the emergency run state. The rules of emergency run are
as follows:
a.Tr>23oC, running refrigerating mode, Ts = 26oC;
b.Tr<23 o C , running heating mode , Ts = 26 o C .

(13) Temperature compensation


There is the function of automatic temperature compensation when
heating, with heating temperature setting = Ts(remote setting) + 4oC

(14) Sleeping function


a.After setting the sleeping function, the refrigerating mode and
dehumidification mode will run as per the following rules:
6hours
T( OC)
1hour
Ts+2
Ts+1 1hour

Ts SLEEP OFF t(hour)


b.After setting the sleeping function, the heating mode will run as per the
following rules:
T( OC)
Ts 3hours 3hours

Ts-2

Ts-4
1hour
Brief introduction to electrical control functions

As shown in the above diagram,after running for 1 hour under refrigerating mode
and dehumidification mode,the setting temperature will increase 1 oC;after another
1 hour,it will increase 1 oC again,and after 6hours,it will cease;after running for
1 hour under heating mode, the setting temperature will decrease 2 oC, after another
1 hour,it will decrease the 2oC again,and after 3 hours,it will increase 1 oC,and after
other 3 hours,it will cease.

(15)Trouble displaying method


a.The temperature sensor of coil pipe of indoor unit is in short circuit or broken
circuit,the timing indicator of indoor unit is on,the power indicator is flickered
in 1Hz;
b.The rom temperature sensor of indoor unit is inshort circuit or broken circuit:
the timing indicator of indoor unit is off,the power indicator is flickered in 1Hz;

c.The motor of indoor unit has nor backfeed of signal, the power indicator of indoor
unit and running indicator are flickered twice,then the power indicator,running indi-
cator and timing indicator are all flickered for 1 second, then repeating the cycle.
(16) Manual defrosting function
Under heating(automatic heating)state,press continuously the SLEEP button on the
control unit for and times till heating 3 sounds from the buzzer, then the whole unit
will turn to the defrosting state.
Abnormity diagnose
Abnormity diagnose
Refrigerating cycle diagram
Refrigerating cycle diagram

AS122ALMBA+AU122ABMEA(HSU-12LF03)
AS122AMMCA+AU122AKMBA(HSU-12LL03)
AS122AKMBA+AU122AKMEA(HSU-12LM03)
AS122ALMAA+AU122AKMBA(HSU-12LP03)
AS122AKMAA+AU122AKMBA(HSU-12LR03)
AS122AMMBA+AU122AKMBA(HSU-12LR03)

indoor unit outdoor unit


heat exchanger heat exchanger
stop valve

comp.

stop valve
filter
capillary tube

AS122AMABA+AU122AKABA(HSU-12RN03)
AS122ALABA+AU122AKABA(HSU-12RP03)
AS122AKAAA+AU122AKABA(HSU-12RR03)
AS122AMACA+AU122AKABA(HSU-12RY03)
AS122ADABA+AU122AKABA(HSU-12RS03)
outdoor unit
indoor unit heat exchanger
heat exchanger stop valve

comp.

capillary tube
stop valve filter

cooling operation
heating operation
Ó
Ò
(HSU-12RS03)
(HSU-12RS03)
AS122ABABA
(HSU-12RS03)

Das könnte Ihnen auch gefallen