Sie sind auf Seite 1von 1

IS458:2003

TABLE 6 DESIGN AND STRENGTH TEST REQUIREMENTS OF CONCRETE PIPES OF CLASS NP4-
REINFORCED CONCRETE,HEAVY DUTY, NON PRESSURE PIPES

STRENGTH TEST REQUIREMENTS FOR


REINFORCEMENT
BARREL TREE EDGE BEARING TEST
INTERNAL
WALL
DIAMETER SPIRALS, LOAD TO
THICKNE LONGITUDNAL MILD
OF PIPES HARD PRODUCE
SS STEEL OR HARD ULTIMATE LOAD
DRAWN 0.25mm
DRAWN STEEL
STEEL CRACK
MINIMUM kg/linear kg/linear
mm mm kN/linear metre kN/linear metre
NUMBER metre metre
1 2 3 4 5 6 7
80 25 6 0.59 0.24 22.1 33.15
100 25 6 0.59 0.36 22.1 33.15
150 25 6 0.59 0.74 23.3 34.95
200 30 6 0.59 1.3 24.6 36.9
225 30 6 0.59 1.64 25.2 37.8
250 30 6 0.59 1.98 25.5 38.25
300 40 8 0.78 2.71 26.4 39.6
350 75 8 0.78 3.14 29.8 44.7
400 75 8 0.78 3.52 33.9 50.9
450 75 8 0.78 3.88 36.9 55.3
500 75 8 0.78 5.96 40 61.2
600 85 8 or 6+6 2.34 9.63 46.3 69.4
700 85 8 or 6+6 3.44 14.33 52.2 78.3
800 95 8 or 6+6 3.44 21.2 59.3 89.1
900 100 6+6 3.44 27.13 66.3 99.4
1000 115 8+8 6.04 35.48 72.6 108.9
1100 115 8+8 6.04 43.76 80.4 120.6
1200 120 8+8 6.04 53.07 88.3 132.4
1400 135 8+8 9.36 77.62 104.2 156.4
1600 140 12+12 9.36 108.97 119.6 179.5
1800 150 12+12 14.88 150.22 135.3 203
2000 170 12+12 14.88 151.79 135.3 203
2200 185 12+12 14.88 160.9 142.2 213.3
2400 200 12+12 14.88 216.96 155 232.5
2600 215 12+12 14.88 258.93 166.7 250

NOTES
1. IF MILD STEEL IS USED FOR SPIRAL REINFORCEMENT, THE WEIGHT SPECIFIED UNDER COL 5
SHALL BE INCREASED TO 140/125

2. THE LONGITUDINAL REINFORCEMENT GIVEN IN THIS TABLE IS VALID FOR PIPES UP TO 2.5m
EFFECTIVE LENGTH FOR INTERNAL DIA OF PIPE UPTO 250mm AND 3m EFFECTIVE LENGTH FOR
HIGHER DIA PIPES

3.TOTAL MASS OF LONGITUDINAL REIGNFORCEMENT SHALL BE CALCULATED BY MULTIPLYING THE


VALUES GIVEN IN COLUMN 4 BY LENGTH OF PIPE AND THEN DEDUCTING FOR THE COVER LENGTH
PROVIDED AT THE 2 ENDS

4. CONCRETE FOR PIPES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 35 N/mm2 AT 28


DAYS.