Protection Application Example

380 kV OHL

17.6. Direction ...................................................................................................... 66


18. Teleprotection for Earth fault overcurrent – Setting Group A .......................... 68
19. Automatic Reclosure – Setting Group A.......................................................... 69
19.1. General........................................................................................................ 69
19.2. 1st Auto Reclose Cycle ................................................................................ 70
19.3. 3pTRIP / Dead Line Charge / Reduced Dead Time .................................... 71
19.4. Start Autoreclose with.................................................................................. 72
20. Synchronism and Voltage Check – Setting Group A....................................... 73
20.1. General........................................................................................................ 73
20.2. Settings for operation with Auto-reclosure................................................... 75
20.3. Settings for operation with Manual Close and Control ................................ 76
21. Fault Locator – Setting Group A...................................................................... 78
22. Oscillographic Fault Records .......................................................................... 78
23. General Device settings .................................................................................. 79
24. Time Synchronisation & Time Format settings................................................ 79
25. Interface Settings ............................................................................................ 80
25.1. Serial port on PC settings............................................................................ 80
25.2. VD Address settings .................................................................................... 80
25.3. Operator interface settings .......................................................................... 81
26. Password settings ........................................................................................... 81
27. Language settings ........................................................................................... 82

Index of Figures and Screen Shots


Figure 1: Single line diagram of protected feeder ............................................................. 4
Figure 2: Selected scope of functions ............................................................................... 7
Figure 3: Configuration of CT and VT circuits ................................................................. 10
Figure 4: Relay connections............................................................................................ 11
Figure 5: VT connections ................................................................................................ 12
Figure 6: Power System Data Settings ........................................................................... 13
Figure 7: Breaker parameters ......................................................................................... 14
Figure 8: Trip command seal in....................................................................................... 15
Figure 9: Setting blocks available in Setting Group A for this application ....................... 16
Figure 10: Power System settings in Power System Data 2........................................... 16
Figure 11: Polygon and Line angle ................................................................................. 18
Figure 12: Positive and zero sequence line impedance profile....................................... 19
Figure 13: Line Status settings in Power System Data 2 ................................................ 21
Figure 14: Trip 1-/3-pole settings in Power System Data 2............................................. 25
Figure 15: General settings for distance protection ........................................................ 25
Figure 16: Load encroachment characteristic ................................................................. 29
Figure 17: Earth fault settings for distance protection..................................................... 30
Figure 18: Earth fault detection logic............................................................................... 31
Figure 19: Stabilised zero sequence pickup threshold.................................................... 31
Figure 20: Impedance distribution for Ph-Ph-E fault with fault resistance....................... 32
Figure 21: Time delay setting for the distance zones...................................................... 33
Figure 22: Influence of fault resistance and remote infeed on measured impedance..... 33
Figure 23: Timing diagram for fault in Figure 22 ............................................................. 34
Figure 24: Time chart to determine time step for graded protection ............................... 35
Figure 25: Distance zone settings (Zone 1) .................................................................... 36
Figure 26: Quadrilateral Zone diagram ........................................................................... 36

7SA522/7SA6 Application Example Page 2 of 82


Version 1.0