01
Pressure Transmitters
For General Applications
Standard Series • Model 891.X3.5X0
Flush Diaphragm Series • Model 891.X3.520
TRONIC LINE Flush Diaphragm Series with Cooling Element • Model 891.X3.522
- Standard • Model 892.X3.5X0
-Series Flush Diaphragm • Model 892.X3.520
General features
This series of pressure transmitters has been carefully designed
such as to cover the majority of industrial applications with instru-
ments readily available from stock.
Compact design and robust construction make these instruments
universally suitable for all applications in machine construction,
process control, laboratory or quality and materials testing equipment.
Structure
Wetted parts are made of stainless steel and are completely welded
to exclude possible conflict of soft sealing material with the pressure
medium. The compact case is also made of stainless steel and
normally provides IP 65 weather protection (special versions up to
IP 68).
Power supply may be by means of non-stabilized DC 10 (14)…30 V
The pressure transmitters does provide the most commonly used
signals.
All pressure transmitters can be supplied with a hermetically sealed
high grade stainless steel case with IP 68 weather protection. This
version ensures unrestricted functionability even when immersed in Model 891.X3.522 Model 892.X3.5X0
water.
For the pressure ranges from 0 … 0.25 bar up to 0 ... 1600 bar the
pressure transmitters can be provided for oxygen applications Supplementary data sheet:
(technical safety check of the BAM ).
Pressure transmitters for
The Series 892.X3.5X0/520 pressure transmitters have been • Low pressure from 0 ... 25 to 0 ... 60 mbar Model 89X.13.501
developed for hazadous area applications requiring certified intrinsic • Hygienic industry Model 891.13.52X
safety of class EEx ia IIC T4 - T6 to CENELEC/DIN/ BASEEFA (see data sheet PE 81.03)
standards or EEx ia I for underground use. Power supply may be
made by either certified zener barriers or certified stand-alone power • Submersible pressure transmitter Model 891.13.535
supply units, as the application demands. Apart from the standard (see data sheet PE 81.09)
version with L-plug there are special versions available with special • Field casing transmitters Model 89X.X3.9X0
plug or with flying cable lead. (see data sheet PE 81.11)
• Digital transmitters Model 891.X3.4XX
(see data sheet PE 81.15)
• Versions with GL-approval Model 891.X3.3XX
(see data sheet PE 81.17)
Specifications Model 89X.13.5XX Model 89X.23.5XX
Sensing principle piezoresistive thin-film strain gauge
Pressure ranges bar 0.1 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250 400 600 1000 1600 2500 4000
Overpressure safety bar 1 1.5 2 2 4 5 10 10 17 35 35 80 50 80 120 200 320 500 800 1200 1500 2000 3000 4400
Burstpressure of sensor bar 2 2 2 2 4 5 10 10 17 35 35 80 250 400 550 800 1000 1200 1700 2400 3000 4000 5000 7000
element
relative pressure relative pressure
Pressure reference {absolute pressure: 0 ... 0.25 bar abs to 0 ... 16 bar abs}
{special pressure range 800 ... 1200 mbar abs}
Pressure connection
Model 89X.X3.500/510 G ½ A per DIN 16 288 (G ¼ A, ½ NPT, ¼ NPT) {other connections on request}
(M 16 x 1.5 female for pressure range 0 … 2500 bar or higher)
Model 89X.X3.520/522 G 1 A flush diaphragm with o-ring (pressure ranges: 0 … 0.1 to 0 … 1.6 bar)
G ½ A flush diaphragm with o-ring (pressure ranges: 0 … 2.5 to 0 …600 bar)
{weld-on socket for flush diaphragm units with connection G ½ A, G 1 A}
Material
wetted parts stainless steel 1.4571 (other materials see WIKA chemical seal)
models 89X.23.510 stainless steel 1.4571 and 1.4542
models 89X.X3.520/522 stainless steel 1.4571 and o-ring: NBR {Viton or EPDM}; {hastelloy C4}
case stainless steel 1.4301
internal transmitting fluid silicon oil (only for pressure ranges up to 0 ... 16 bar or flush diaphragm units)
{halocarbonoil for oxygen service, vegetable oil for food industry}
Power supply UB for -transmitters, models 892.X3.5X0: see below in section - protection !
for none -transmitters DC V 10 < UB £ 30 (14 ... 30 V with signal output 0 ... 10 V)
Signal output and 4 … 20 mA, 2-wire system RA £ [Ohm] (UB [V]-10 [V]) / 0.02 [A]
maximum load R A 0 … 20 mA, 3-wire system RA £ [Ohm] (UB [V]-10 [V]) / 0.02 [A]
{0 … 5 V, 3-wire system} RA > 5 kOhm
{0 … 10 V, 3-wire system} R A >10 kOhm
Adjustability zero/span % ± 10 {other signal outputs on request}
Response time (10 … 90%) ms £ 1
Accuracy % of span £ 0.5 {0.251)} (limit point calibration) calibrated in vertical mounting position
% of span £ 0.25 {0.151)} (BFSL) (
with pressure connection bottom )
Hysteresis % of span £ 0.1
Repeatability % of span £ 0.05
1-year stability % of span £ 0.2 (at reference conditions)
Permissible temperature of
medium °C (°F) -30 … +100 (-22 ... +212) model 891.X3.522: -10 ... +150 (+14 ... +302)
°C (°F) {-40 ... +125} {(-40 ... +257)}
ambient °C (°F) -20 … +80 ( -4 ... +176) model 891.X3.522: -10 ... +80 (+14 ... +176)
storage °C (°F) -40 … +100 (-40 ... +212) model 891.X3.522: -10 ... +100 (+14 ... +212)
Compensated temp. range °C (°F) 0 … +80 (+32 ... +176)
Temperature coefficient in
compensated temp. range:
mean TC of zero % of span/10 K £ 0.2 (< 0.4 with pressure ranges 0 … 0.1 and 0 … 0.16 bar)
mean TC of range % of span/10 K £ 0.2
-protection model 892.13.500/520 and model 892.23.510/520
Signal output 4 … 20 mA, 2-wire system
-certification EEx ia IIC T4 EEx ia IIC T5 EEx ia IIC T6
(BVS 92.C.2028) (BVS 92.C.2028) (BVS 92.C.2028)
Conformity specifications:
power supply DC V 10 … 28 10 … 28 10 … 28
short circuit rating mA 660 660 660
power limitation W 1.75 1.75 1.75
medium temperature °C (°F) -20 … +100 (-4 ... +212) -20 … +75 (-4 ... +167) -20 … +60 (-4 ... +140)
ambient temperature °C (°F) -20 … +80 (-4 ... +176) -20 … +75 (-4 ... +167) -20 … +60 (-4 ... +140)
storage temperature °C (°F) -20 … +80 (-4 ... +176) -20 … +80 (-4 ... +176) -20 … +80 (-4 ... +176)
see certification of conformity BVS 92.C.2028 for additional data
-conformity Interference emission per EN 50 081-1 (march 93) and EN 50 081-2 (march 94),
Interference immunity per EN 50 082-2 (march 95); declaration of conformity on request
Electrical connection 4-pin L-plug per DIN 43 650
optionally for non- -transmitters:
{cable:1.5 m, vented, flying lead; 5-pin plug; 6-pin MIL-plug}
optionally for -transmitters: {1.5 m of vented cable}
Wiring protection protected against polarity crossing, overvoltage, and short circuiting;
-transmitters only protected against reverse polarity
Degree of protection
per EN 60 529 / IEC 529 IP 65 {IP 67 with cable or special plug; IP 68 with cable and special case}
Weight kg approx. 0.2; -transmitters approx. 0.35
Dimensions see drawings
Items in curved brackets { } are optional extras for additional price.
1) with pressure ranges ³ 0.25 bar only
2
PE 81.01
Dimensions in mm
IP 67
1605216
1605186 1605208
G½A G1A
1605224 1605234
weld-on adaptors resp. socketsfor pressure connection for flush diaphragm with o-ring (model 891.X3.52X)
G½ G1
finless 1524305
finless 1524283
3
Wiring details
2-wire system
DIN 43 650 plug MIL-plug PT 02 E-10-6P 5-pin plug flying lead
3-wire system
DIN 43 650 plug MIL-plug PT 02 E-10-6P 5-pin plug flying lead
S+ S+
white S+ (3)
S+
Printed in Germany
Ordering information
Model / Pressure range / Signal output / Pressure connection / Optional extras
Ordering examples:
891.13.500 / 0 … 2.5 bar / 4 … 20 mA / G ½ A / Temperature of pressure medium -40 … +125 °C
W 963 GB 30 10.97 CM 9029702
Specifications and dimensions given in this leafet represent the state of engineering at the time of printing. Modifications
may take place and materials specified may be replaced by others without prior notice.