LVDS Interconnection Market Board to Panel

AX080A043E- Harish Hegde


IPS Alpha 09448906211
1 GND
2 Test This graph shows How to connect LVDS cable V59,V56 market board to
3 AGW different PANELs.
4 NC
5 NC
6 NC
7 LVDSsel Market Board HV320WX2-261-
LC320EXJ-SEE1
8 NC connector BOE
LG
9 NC
1 VCC 1 12V VCC 1 NC
10 NC
2 VCC 2 12V VCC 2 SCL
11 GND
3 VCC 3 12V VCC 3 SDA
12 RxA0-
4 GND 4 12V VCC 4 GND
13 RxA0+
5 GND 5 GND 5 RX0-
14 RxA1-
6 NC 6 GND 6 RX0+
15 RxA1+
7 TXO0- 7 GND 7 GND
16 RxA2-
8 TXO0+ 8 GND 8 RX1-
17 RxA2+
9 TXO1- 9 LVDSsel. 9 RX1+
18 GND
10 TXO1+ 10 NC 10 GND
19 CLKA-
11 TXO2- 11 GND 11 RX2-
20 CLKA+
12 TXO2+ 12 RA- 12 RX2+
21 GND
13 GND 13 RA+ 13 GND
22 RxA3-
14 GND 14 GND 14 RXCLK-
23 RxA3+
15 TXOC- 15 RB- 15 RXCLK+
24 NC
16 TXOC+ 16 RB+ 16 GND
25 NC
17 TXO3- 17 GND 17 RX3-
26 GND
18 TXO3+ 18 RC- 18 RX3+
27 GND
19 TXE0- 19 RC+ 19 GND
28 RxB0-
20 TXE0+ 20 GND 20 NC
29 RxB0+
21 TXE1- 21 RCLK- 21 NC
30 RxB1-
22 TXE1+ 22 RCLK+ 22 WP
31 RxB1+
23 TXE2- 23 GND 23 GND
32 RxB2-
24 TXE2+ 24 RD- 24 GND
33 RxB2+
25 GND 25 RD+ 25 GND
34 GND
26 GND 26 GND 26 12V VCC
35 CLKB-
27 TXEC- 27 NC 27 12V VCC
36 CLKB+
28 TXEC+ 28 NC 28 12V VCC
37 GND
29 TXE3- 29 NC 29 12V VCC
38 RxB3-
30 TXE3+ 30 GND 30 12V VCC
39 RxB3+
40 NC
41 NC
42 GND
43 GND
44 GND
45 GND 1. Connect all GND to GND
46 GND 2. All NC and other signals not required
47 NC 3. All wires should interchange panel side LVDS cable
48 12V VCC
49 12V VCC 4. Keep twisted wires twist condition only
50 12V VCC
51 12V VCC Drawn By Harish Hegde