ACS800 multidrive 6- and 12- pulse operation

V1 W1
U1

+ UC Unet
_

UD1
Unet 1. 2. 3. 4. 5. 6.
U1 V1 W1

UD
UD2
60o
360 o

1. 2. 3. 4. 5. 6.
+ UC U1 V1 W1
_
U D1
60o

U1 = U 0 o

Unet UD1 1. 2. 3. 4. 5.
W2
6.
U2 V2
U D2
U2 = U 30o
UD2
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12
30o
U1 U2 V1 V2 W1 W2
UC

360o

ACS800 - 1, rev. 1 Copyright © ABB Oy


ACS800 multidrive Diode supply system board

Diode supply system board


The (parallel) DSU modules (1-5 pcs) are controlled
Actual value display
by the common DSSB (Diode supply system board).
The amount of DSU modules (S1) and the limit of the
earth fault current (S2) are defined with the dip-
switches of the DSSB board . Displayed actual value
Supply power, currents or voltages can be indicated
with seven segment actual value display of the
board.
The value is indicated with the yellow LEDs on the
board.
The displayed variable can be changed by display
selection buttons. Supply status leds
Supply unit faults are indicated with red LEDs.

Supply dip- switches


S2 S1

ACS800 - 2, rev. 1 Copyright © ABB Oy


ACS800 multidrive Dip switch settings

Dip settings (earth fault current)


Switch S1
PIN 1(1A) PIN 2 (2A) PIN 3 (4A) PIN 4 (8A) PIN 5 (16A) PIN 6
Switched off OFF OFF OFF OFF OFF
1A ON OFF OFF OFF OFF
2A OFF ON OFF OFF OFF
3A ON ON OFF OFF OFF
4A OFF OFF ON OFF OFF
5A ON OFF ON OFF OFF
(Default) 6A OFF ON ON OFF OFF
7A ON ON ON OFF OFF
8A OFF OFF OFF ON OFF
….
31A ON ON ON ON ON
Dip settings (amount of modules)
Switch S2
PIN 1 PIN 2 PIN 3 PIN 4
1 module OFF OFF OFF OFF
2 modules ON OFF OFF OFF
3 modules OFF ON OFF OFF
4 modules OFF OFF ON OFF
5 modules OFF OFF OFF ON

ACS800 - 3, rev. 1 Copyright © ABB Oy