Beruflich Dokumente
Kultur Dokumente
Acetylene Dissolved
Page: 1 of 3
Revision Date : 03 July 2006
1. Chemical Product and Company Identification LONG TERM EXPOSURE: no information on significant
adverse effects
Product Name : Acetylene, Dissolved EYE CONTACT:
Trade Name/Synonym: Acetylene; Ethyne; Welding Gas; SHORT TERM EXPOSURE: irritation
Acetylen; Ethine; Narcylen; Vinylene LONG TERM EXPOSURE: no information on significant
adverse effects
Formula : C2H2
Chemical Family: hydrocarbons, aliphatic SKIN CONTACT:
Company Identification : SHORT TERM EXPOSURE: rash
PT. Samator
LONG TERM EXPOSURE: no information is available
Emergency Phone Number : EYE CONTACT:
+62 31 750 7050, 750 7550 SHORT TERM EXPOSURE: no information on
+62 24 8662097 significant adverse effects
+62 21 8900933, 8900934 LONG TERM EXPOSURE: no information is available
+62 542 413063, 411539 INGESTION:
+62 511 4705738, 4705835 SHORT TERM EXPOSURE: ingestion of a gas is
unlikely
2. Composition / Information on Ingredients LONG TERM EXPOSURE: ingestion of a gas is unlikely
EMERGENCY OVERVIEW:
COLOR: colorless 5. Fire Fighting Measure
PHYSICAL FORM: gas
ODOR: sweet odor FIRE AND EXPLOSION HAZARDS: Severe explosion
MAJOR HEALTH HAZARDS: central nervous system hazard. Vapor/air mixtures are explosive.
depression, difficulty breathing. Electrostatic discharges may be generated by flow or
PHYSICAL HAZARDS: May explode when heated. agitation resulting in ignition or explosion.
Flammable gas. May cause flash fire. Electrostatic charges
may be generated by flow, agitation, etc. May polymerize. EXTINGUISHING MEDIA: carbon dioxide, regular dry
Container may rupture or explode. chemical Large fires: Use regular foam or flood with fine
water spray.
POTENTIAL HEALTH EFFECTS: FIRE FIGHTING: Move container from fire area if it can
INHALATION: be done without risk. For fires in cargo or storage area: Cool
SHORT TERM EXPOSURE: nausea, vomiting, chest containers with water from unmanned hose holder or
pain, wheezing, headache, drowsiness, monitor nozzles until well after fire is out. If this is
dizziness, loss of coordination, bluish skin color, impossible then take the following precautions: Keep
suffocation, lung congestion, coma unnecessary people away, isolate hazard area and deny
entry. Let the fire burn. Withdraw immediately in case of
LONG TERM EXPOSURE: no information on rising sound from venting safety device or any discoloration
significant adverse effects of tanks due to fire. For tank, rail car or tank truck: Stop
SKIN CONTACT: leak if possible without personal risk. Let burn unless leak
SHORT TERM EXPOSURE: no information on can be stopped immediately. For smaller tanks or cylinders,
significant adverse effects extinguish and isolate from other flammables. Evacuation
PT. SAMATOR
Head Office: Graha Pangeran Building 8th fl, Jl. A. Yani No. 286 Surabaya 60234. Telp. (031) 829 2727 (Hunting), Fax. (031) 829 2708-9. Email: samator@samator.com
Factory : Bekasi (West Java); Gresik (East Java); Kendal (Central Java); Balikpapan (East Kalimantan); Banjarmasin (South Kalimantan).
Material Safety Data Sheet
Acetylene Dissolved
Page: 2 of 3
Revision Date : 03 July 2006
radius: 800 meters (1/2 mile). Do not attempt to extinguish protection is ranked in order from minimum to maximum.
fire unless flow of material can be stopped first. Flood with Consider warning properties before use.
fine water spray. Cool containers with water spray until For Unknown Concentrations or Immediately
well after the fire is out. Apply water from a protected Dangerous to Life or Health -
location or from a safe distance. Avoid inhalation of Any supplied-air respirator with full facepiece and operated
material or combustion by-products. Stay upwind and keep in a pressure-demand or other positive-pressure mode in
out of low areas. Evacuate if fire gets out of control or combination with a separate escape supply. Any self-
containers are directly exposed to fire. Evacuation radius: contained breathing apparatus with a full facepiece.
500 meters (1/3 mile). Consider downwind evacuation if
material is leaking. Stop flow of gas. 9. Physical and Chemical Properties
PT. SAMATOR
Head Office: Graha Pangeran Building 8th fl, Jl. A. Yani No. 286 Surabaya 60234. Telp. (031) 829 2727 (Hunting), Fax. (031) 829 2708-9. Email: samator@samator.com
Factory : Bekasi (West Java); Gresik (East Java); Kendal (Central Java); Balikpapan (East Kalimantan); Banjarmasin (South Kalimantan).
Material Safety Data Sheet
Acetylene Dissolved
Page: 3 of 3
Revision Date : 03 July 2006
ADDITIONAL DATA : Stimulants such as
epinephrine may induce ventricular fibrilation
ACUTE: Yes
CHRONIC: No
FIRE: Yes
REACTIVE: Yes
SUDDEN RELEASE: Yes
PT. SAMATOR
Head Office: Graha Pangeran Building 8th fl, Jl. A. Yani No. 286 Surabaya 60234. Telp. (031) 829 2727 (Hunting), Fax. (031) 829 2708-9. Email: samator@samator.com
Factory : Bekasi (West Java); Gresik (East Java); Kendal (Central Java); Balikpapan (East Kalimantan); Banjarmasin (South Kalimantan).