10 counts.
TD sensor (Vt high) error 2: M
TD sensor harness disconnected,
The Vt value of the black, magenta, cyan,
loose, defective. A drawer
365 or yellow TD sensor is below the specified
connector disconnected, loose,
value with SP3020-004 (default: 0.5V) for
defective. TD sensor defectiver.
10 counts.
TD sensor (Vt high) error 2: C
TD sensor harness disconnected,
The Vt value of the black, magenta, cyan,
loose, defective. A drawer
366 or yellow TD sensor is below the specified
connector disconnected, loose,
value with SP3020-004 (default: 0.5V) for
defective. TD sensor defectiver.
10 counts.
TD sensor (Vt high) error 2: Y
TD sensor harness disconnected,
The Vt value of the black, magenta, cyan,
loose, defective. A drawer
367 or yellow TD sensor is below the specified
connector disconnected, loose,
value with SP3020-004 (default: 0.5V) for
defective. TD sensor defectiver.
10 counts.
TD sensor adjustment error: K Heat seal not removed from a new
During TD sensor initialization, the output developer pack. TD harness
value of the black, magenta, cyan, or yellow sensor disconnected, loose or
372
TD sensor is not within the range of the defective. TD sensor defective.
specified value with SP3238-001 to -004 Harness between TD sensor and
(default: 2.7V) +- 0.2V drawer disconnected, defective.
TD sensor adjustment error: M Heat seal not removed from a new
During TD sensor initialization, the output developer pack. TD harness
value of the black, magenta, cyan, or yellow sensor disconnected, loose or
373
TD sensor is not within the range of the defective. TD sensor defective.
specified value with SP3238-001 to -004 Harness between TD sensor and
(default: 2.7V) +- 0.2V drawer disconnected, defective.
(hardware error)
BCU • Defective heating roller
During stand-by mode or a print job, the
thermistor (end) • Defective
detected heating roller temperature reaches
fusing control system
250 °C.
Heating roller fusing lamp consecutive full
power 1 • Broken heating roller
545 When the fusing unit is not running in the thermostat • Broken heating
ready condition, the heating roller fusing lamp roller fusing lamp
keeps on full power for 8 seconds.
Zero cross error
• The zero cross signal is detected for 0.05
seconds three times even though the heater
relay is off when turning on the main power. •
The zero cross signal is not detected for 3 • Defective fusing lamp relay •
547 seconds even though the heater relay is on Defective fusing lamp relay
after turning on the main power or closing the circuit • Unstable power supply
front door. • The detection error occurs twice
or more in the 11 zero cross signal detections.
This error is defined when the detected zero
cross signal is less than 45.
Heating roller thermistor (end) error 2 • Loose connection of heating
• The temperature measured by the heating roller thermistor (end) •
551
roller thermistor (end) does not reach 0°C for 6 Defective heating roller
seconds. thermistor (end)
• Dirty or defective thermistor
Heating roller warm-up error 2
(end) • Heating roller fusing
The heating roller temperature does not reach
552 lamp broken • Defected
the ready temperature while 70 seconds after
thermostat • Defective heating
the heating lamp on.
roller fusing lampamp on.
Heating roller fusing lamp overheat 2
(software error) • Defective PSU • Defective
553
The detected pressure roller temperature BCU
stays at 230°C or more for 1 second.
Heating roller fusing lamp overheat 2 • Defective heating roller
(hardware error) thermistor (end) • Defective
554
The heating roller thermistor (end) detects PSU • Defective BCU •
250°C or more. Defective fusing control system
Heating roller lamp consecutive full power 2
When the fusing unit is not running in the • Broken heating roller
555 ready condition, the pressure roller-fusing thermostat • Broken heating
lamp keeps ON full power for 8 seconds or roller fusing lamp
more.
557 Zero cross frequency error • Noise (High frequency)
12
914
External Controller Error 6
• Power outage at the EFI
While EAC (External Application Converter), the
controller • EFI controller
conversion module, was operating normally, the
919 was rebooted •
receipt of a power line interrupt signal from the
Connection to EFI
FLUTE serial driver was detected, or BREAK
controller loose
signal from the other station was detected.