Sie sind auf Seite 1von 4

9/22/2018

AE-321: Water Supply and Sanitation


System for Buildings

Lecturer
Anam Fatima
Plumbing Design Drainage system
PhD Scholar (PhD. Architectural Engineering)
BSc. (Architectural Engineering),MS (Construction Engineering & Management)
Department of Architectural Engineering and Design
University of Engineering and Technology
Lahore

AE 321 WSSSB (CI-Engr. Anam Fatima) 4 AE 321 WSSSB (CI-Engr. Anam Fatima) 5 AE 321 WSSSB (CI-Engr. Anam Fatima) 6

1
9/22/2018

AE 321 WSSSB (CI-Engr. Anam Fatima) 7 AE 321 WSSSB (CI-Engr. Anam Fatima) 8 AE 321 WSSSB (CI-Engr. Anam Fatima) 9

Waste is produced at fixtures such as toilets,


sinks and showers, and exits the fixtures
through a trap, a dipped section of pipe that
always contains water. All fixtures must contain
traps to prevent sewer gases from leaking into
the house.

AE 321 WSSSB (CI-Engr. Anam Fatima) 10 AE 321 WSSSB (CI-Engr. Anam Fatima) 11 AE 321 WSSSB (CI-Engr. Anam Fatima) 12

2
9/22/2018

Bottle Trap: Provided under sinks in bathroom Trap


and kitchens. Floor Trap / Floor Drain
Designers and plumbers use bottle traps when
plumbing space is limited in kitchens and A floor drain is a plumbing fixture that is
bathrooms. installed in the floor of a structure, mainly
designed to remove any standing water near it.

They are usually round, but can also be square


or rectangular. They usually range from 2 to 12
inches (5.1 to 30.5 cm); most are 4 inches (10
cm) in diameter.

AE 321 WSSSB (CI-Engr. Anam Fatima) 13 AE 321 WSSSB (CI-Engr. Anam Fatima) 14 AE 321 WSSSB (CI-Engr. Anam Fatima) 15

AE 321 WSSSB (CI-Engr. Anam Fatima) 16 AE 321 WSSSB (CI-Engr. Anam Fatima) 17 AE 321 WSSSB (CI-Engr. Anam Fatima) 18

3
9/22/2018

AE 321 WSSSB (CI-Engr. Anam Fatima) 19 AE 321 WSSSB (CI-Engr. Anam Fatima) 20 AE 321 WSSSB (CI-Engr. Anam Fatima) 21

AE 321 WSSSB (CI-Engr. Anam Fatima) 22 AE 321 WSSSB (CI-Engr. Anam Fatima) 23

Das könnte Ihnen auch gefallen