EKFC EXPO CENTRAL KITCHEN PLOT No. TP-238 at DUBAI SOUTH, DUBAI
DOCUMENT No: REV. No: DATE:
Page 1 of 7
DJ-274-P-QC-ITP-0013 00 15-10-2019
INSPECTION AND TEST PLAN FOR CHAIN LINK FENCE SYSTEM & GATES
1. SCOPE
The Scope of this Inspection and Test Plan is to establish the quality requirements
for the receiving of materials Fabrication, Galvanizing, Packing and Delivery of
Handrails as per Drawing and Specifications.
2. REFERENCE CODES
BS EN ISO 1461:2009 – Hot Dip galvanized coatings on fabricated iron & steel
articles- Specification & test method.
EKFC EXPO CENTRAL KITCHEN PLOT No. TP-238 at DUBAI SOUTH, DUBAI
DOCUMENT No: REV. No: DATE:
Page 2 of 7
DJ-274-P-QC-ITP-0013 00 15-10-2019
INSPECTION AND TEST PLAN FOR CHAIN LINK FENCE SYSTEM AND GATES
Customer
Client/
PROCEDURE ACCEPTANCE QUALITY
SL NO
GKWI
ITL
QUALITY REFERENCE/CODE/ CRITERIA I VERIFICATION
WORK CHARACTERISTIC TO STANDARD VALUE RECORD PERFORMED
ACTIVITY BE VERIFIED BY
Approved documents
Supplier
Drawing - Approval of Documents Contract document from client as per
1 Document Q.C H - DR
Approval for construction Specifications contract specification
Register in
Suitable for the
operation in working
condition,
Equipment I Calibration
No visible damages.
Tools Capacity Condition Quality System report,
2 Q.C 1 - DR
I Instrument Calibration status procedures Certificates of
Calibrated & Valid
Status Equipment’s
calibration sticker on
instruments.
Procurement of
Raw material
Raw materials - Purchase order
Specification as per
SS Pipes, GI specification as per Q.C
Project specification QSP Procedures Project
pipes, SS rods, project Specification, P.O order
4 and approved Drawing. Specifications 1 - R
MS rods, MS P.O qty as per BOQ Stores Officer
Approved supplier I
Plates, MS Plates, quantity
trader
Fasteners
EKFC EXPO CENTRAL KITCHEN PLOT No. TP-238 at DUBAI SOUTH, DUBAI
DOCUMENT No: REV. No: DATE:
Page 3 of 7
DJ-274-P-QC-ITP-0013 00 15-10-2019
INSPECTION AND TEST PLAN FOR CHAIN LINK FENCE SYSTEM AND GATES
LEGEND
DR: Document Review, A11A21A3 = Actual inspection ( 1=100%,2 =10% 3 = As detailed) W= witness , H= hold, S= Submit, T= test , R
=Random
Customer
Client/
SL NO
GKWI
ITL
QUALITY PROCEDURE ACCEPTANCE QUALITY
WORK CHARACTERISTIC TO REFERENCE/CODE/ CRITERIA I VERIFICATION PERFORMED
ACTIVITY BE VERIFIED STANDARD VALUE RECORD BY
Heat number
5 Receiving of MS Dimensions, OD & Project Specifications Delivery note Mill Test Q.C 1 - DR
Pipes, MS rods, thickness Standard Codes- certificate EN
MS Plates, BS EN 10025 S 235 jr No physical damages 10204 3 .1 Stores Officer
angles, Fasteners Grade, Mechanical & Inspection
Chemical Properties MTC compliance to reports
Approved shop Standard codes I
Free from damages, Drawings specification
metal folding Qty, requirements
Identification
Identification as per
Delivery Note
EKFC EXPO CENTRAL KITCHEN PLOT No. TP-238 at DUBAI SOUTH, DUBAI
DOCUMENT No: REV. No: DATE:
Page 4 of 7
DJ-274-P-QC-ITP-0013 00 15-10-2019
INSPECTION AND TEST PLAN FOR CHAIN LINK FENCE SYSTEM AND GATES
Customer
Client/
SL NO
GKWI
QUALITY PROCEDURE QUALITY
ITL
ACCEPTANCE
CHARACTERISTIC TO REFERENCE/CODE/ VERIFICATIO PERFORMED
WORK ACTIVITY CRITERIA I
BE VERIFIED STANDARD N RECORD BY
VALUE
INSPECTION AND TEST PLAN FOR CHAIN LINK FENCE SYSTEM AND GATES
LEGEND
DR: Document Review, A 1I A2 I A3 =Actual Inspection ( 1=100%,2 =10% 3 =As detailed) W= witness, H= hold, S= Submit, T= test, R
=Random, Q.C =Quality Control
Customer
Client/
SL NO
GKWI
QUALITY PROCEDURE QUALITY
ITL
ACCEPTANCE
CHARACTERISTIC TO REFERENCE/ CODE/ VERIFICATIO PERFORM ED
WORK ACTIVITY CRITERIA I
BE VERIFIED STANDARD N RECORD BY
VALUE
Finishing and
Drilling holes on Hole size, Position
Inspection
6 Base Plate, Post, Distance, depth, Shop drawing Work As per drawing No sharp Q.C 1 - R
Report
handrail as per visuals instructions edges
drawing
EKFC EXPO CENTRAL KITCHEN PLOT No. TP-238 at DUBAI SOUTH, DUBAI
DOCUMENT No: REV. No: DATE:
Page 6 of 7
DJ-274-P-QC-ITP-0013 00 15-10-2019
INSPECTION AND TEST PLAN FOR CHAIN LINK FENCE SYSTEM AND GATES
LEGEND
DR: Document Review, A 1I A2 I A3 =Actual Inspection ( 1=100%,2 =10% 3 =As detailed) W= witness, H= hold, S= Submit, T= test, R
=Random, Q.C =Quality Control
Customer
Client/
SL NO
GKWI
QUALITY PROCEDURE QUALITY
ITL
ACCEPTANCE
CHARACTERISTIC TO REFERENCE/ CODE/ VERIFICATIO PERFORMED
WORK ACTIVITY CRITERIA I
BE VERIFIED STANDARD N RECORD BY
VALUE
OD as per drawing.
Diameter of rod Approved drawing
Cutting and No bends, buckling Inspection
7 Straightness of rods Q.C 1 - R
Finishing of MS rods SS rods with satin finish report
Finishing of Rods Work instructions
INSPECTION AND TEST PLAN FOR CHAIN LINK FENCE SYSTEM AND GATES
LEGEND
DR: Document Review, A 1I A2 I A3 =Actual Inspection ( 1=100%,2 =10% 3 =As detailed) W= witness, H= hold, S= Submit, T= test, R
=Random, Q.C =Quality Control
Customer
Client/
SL NO
GKWI
QUALITY PROCEDURE QUALITY
ITL
ACCEPTANCE
CHARACTERISTIC TO REFERENCE/ CODE/ VERIFICATIO PERFORM ED
WORK ACTIVITY CRITERIA I
BE VERIFIED STANDARD N RECORD BY
VALUE
Surface preparations
Free from defects Coating/
No visual defects after
Powder/ PVC Even coating, No holes, Painting
10 galvanizing. No Work instructions Q.C 3 - w
Coating/ Painting bubbles. Shade as per Inspection
Projections. Visuals
approved drg or sample. report
Dimensions as per
approved Drawing Mill test
Certificates
Pre dispatch No physical damages Q.C
Inspection, before Packing, Purchase order All Inspection report
Inspection
11 Identification, specifications Work Proper Packing H - DR
and Dispatch In-
Packing Post, instructions Ends to be protected
Test reports charge
Handrails, and Protection with Packing List
proper packing, Edge Delivery notes
Protection