Sigunit®-L20
Sigunit®-L20
Liquid shotcrete accelerating admixture for the wet spray
process
Construction
Product
Description Liquid accelerator for the wet spray shotcrete process.
Uses Sigunit®-L20 is a liquid accelerator for the wet spray process of concrete in thin or
thick stream applications (gunite and shotcrete) i.e. for:
Shotcrete with high initial strengths
Heading stabilisation in tunnelling
Rock and slope stabilisation
Underground linings (i.e. in tunnels)
To form permanent gunite or shotcrete shells
Characteristics The accelerator’s effect is dependent on the cement content, type and age,
Advantages / substrate temperature and type, shotcrete temperature, layer thickness and spray
process / equipment. The water/cement ratio of the basic concrete mix is another
®
important parameter which influences the acceleration effect of Sigunit -L20.
®
The following properties distinguish Sigunit -L20:
Exceptional early strength development
Low rebound
Layer thicknesses up to 30 cm can be applied in one operation
Improves the bond of the shotcrete to rock and concrete, making overhead
spraying easier
Chloride free, does not attack or corrode iron or steel reinforcement
Product Data
Form
Appearance / Colours Yellowish liquid
Packaging 250 kg non-returnable containers (drums)
1000 kg returnable IBC’s
Storage
Storage Conditions / Sigunit®-L20 must be stored in its original containers.
Shelf Life
Sigunit®-L20 has a reaction in air with atmospheric humidity[moisture] or rain etc.,
®
and must therefore always be stored in sealed containers. Sigunit -L20 should only
be decanted into clean containers. Avoid mixing with air - filling through floor inlets
or immersed pipes is best. Containers must always be properly sealed.
Do not store in aluminium tanks.
1 Sigunit®-L20 1/3
Protect from extreme cold.
4 months from date of production if stored in undamaged and unopened, original
sealed containers.
Note: Once containers are opened, use the material as quickly as possible.
Technical Data
Chemical Base Special inorganic blend of materials
Density 1.5 kg/l
System
Information
System Structure Pump granulometry:
Normal max. particle size 8 mm to 16 mm.
Concrete consistency (dependent on spray equipment):
concrete flow 45 cm; W/C 0.48.
® ® ®
A suitable flow agent is required (e.g. Sika ViscoCrete SC-305 / SikaTard -203).
Fresh concrete temperature: > +15°C.
Application Details
Dosage The correct dosage must be determined by preliminary testing. For layer
thicknesses of up to about 20 cm in one pass, dosage is between 3% and 6% by
weight of binder.
The following Sika products are generally used to improve the performance or
application properties of the basic concrete mix:
®
- SikaTard -203
® ®
- Sika ViscoCrete SC-305
®
- SikaTard -930
®
- SikaPump
® ® ®
- SikaFume -HR / -TU / Sikacrete -L / Sikacrete -PP1 TU
Application
Conditions /
Limitations
Ambient Temperature Above +1°C
Application
Instructions
Notes on Application / Sigunit®-L20 must be added with a gauging device suitable for the wet spray
Limitations process.
Skilled nozzle operation and thorough mixing within the concrete are essential.
The fresh concrete characteristics (correct workability) must be adjusted to suit the
spray equipment, its capacity, temperature and other local conditions.
® ®
Sigunit -L20 is not compatible with Sigunit -L50 AF / -L52 AF / -L53 AF.
Ask for technical support from your local Sika Company.
Notes All technical data stated in this Product Data Sheet are based on laboratory tests.
Actual measured data may vary due to circumstances beyond our control
Local Restrictions Please note that as a result of specific local regulations the performance of this
product may vary from country to country. Please consult the local Product Data
Sheet for the exact description of the application fields.
2 Sigunit®-L20 2/3
Please insert any additional Standard Health and Safety Information in
Health and Safety accordance with local laws and which are not already stated in the safety data
Information sheet. For questions contact your Ecology and Safety-Manager.
Protective Measures To avoid allergic reactions, we recommend the use of protective gloves and facial
masks. In case of contact with skin or eyes, rinse immediately with clean water and
seek medical attention without delay.
Local regulations and health and safety advice on the packaging labels must be
observed.
Ecology Insert local law information (if product not classified, please remove)
Transportation Class Insert local law information (if product not classified, please remove)
Important Notes Must be disposed of as hazardous waste in accordance with local regulations.
Please consult material safety data sheet. Do not discharge into drainage systems,
waterways or groundwater.
Residues of material must be removed according to local regulations. Fully cured
Construction
Sika Services AG
Tüffenwies 16 Phone +41 44 436 40 40
CH-8048 Zurich Telefax +41 44 436 46 86
Switzerland www.sika-construction.com