Produced on 30/03/2017 with Xpress Selection V7.5.4 - database DIL 11.9.

Project name Edif B (Edif Sede)


Project address Villahermosa
Mexico
Reference FCH
Client name Román Mayo
Client address Villahermosa
Revision 01

Selection parameters of the indoor units can be found under the chapter Indoor unit details
Selection parameters of the outdoor units can be found under the chapter Outdoor unit details
Only the data published in the data book are correct. This program uses close approximations of these data.

1. Material List
Model Qty Description
RHXYQ32ATL 1 Heat pump VRV IV 220V(TL)
FXAQ25PVE 2 VRV AP - Wall Mounted(Flat Panel)
FXFSQ32AVE 2 VRV FS(AVE) - Ceiling Mounted Cassette(Round Flow with Sensing)
FXFSQ40AVE 3 VRV FS(AVE) - Ceiling Mounted Cassette(Round Flow with Sensing)
FXFSQ50AVE 8 VRV FS(AVE) - Ceiling Mounted Cassette(Round Flow with Sensing)
FXFSQ63AVE 3 VRV FS(AVE) - Ceiling Mounted Cassette(Round Flow with Sensing)
FXFSQ71AVE 1 VRV FS(AVE) - Ceiling Mounted Cassette(Round Flow with Sensing)
KHRP26A22T 7 Refnet branch piping kit
KHRP26A33T 3 Refnet branch piping kit
KHRP26A72T 7 Refnet branch piping kit
KHRP26A73T + KHRP26M73TP 1 Refnet branch piping kit
DCM601A51 1 intelligent Touch Manager
BRC1E62 15 Wired Remote Controller (Navigation Remote Controller)
BYCSP125BW1 17 Decoration panel
BHFP22P100 1 Outdoor unit multi connection piping kit
R410A 19.4kg Extra refrigerant charge
Piping ¼" 55.0m
Piping ⅜" 49.0m
Piping ½" 72.0m
Piping ⅝" 46.0m
Piping ¾" 25.0m
Piping ⅞" 3.0m
Piping 1⅛" 22.0m
Piping 1¼" 20.0m

2. Indoor Unit Details


2.1. Table of Abbreviations
Name Logical name of the device
FCU Device model name
Tmp C Indoor conditions in cooling (dry bulb temp. / RH)
Rq TC Required total cooling capacity
Rv TC Revised total cooling capacity (asked from outdoor)
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 1
Max TC Available total cooling capacity
TC Total cooling capacity
Rq SC Required sensible cooling capacity
Max SC Available sensible cooling capacity
SC Sensible cooling capacity
HC Heating capacity
Sound Sound pressure low and high
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHxD WidthxHeightxDepth
Wght Weight of the device

2.2. UE 1 - RHXYQ32ATL
Capacity data at conditions and connection ratio (111%) as entered
Name FCU Tmp C Rq TC Rv TC Max TC Rq SC Max SC
°C kW kW kW kW kW
UI 1 FXFSQ50AVE 24.0 / 50% 4.0 n/a 4.8 3.1 4.7
UI 2 FXFSQ63AVE 24.0 / 50% 5.0 n/a 6.1 4.4 5.5
UI 3 FXFSQ71AVE 24.0 / 50% 6.8 n/a 6.9 5.7 6.0
UI 4 FXFSQ63AVE 24.0 / 50% 6.0 n/a 6.1 5.0 5.5
UI 5 FXFSQ63AVE 24.0 / 50% 6.0 n/a 6.1 5.1 5.5
UI 6 FXFSQ32AVE 24.0 / 50% 3.1 3.1 3.1 2.6 2.6
UI 7 FXAQ25PVE 24.0 / 50% 2.1 n/a 2.4 1.8 2.0
UI 8 FXAQ25PVE 24.0 / 50% 2.1 n/a 2.4 1.8 2.0
UI 9 FXFSQ32AVE 24.0 / 50% 2.8 n/a 3.1 2.4 2.6
UI 10 FXFSQ40AVE 24.0 / 50% 3.6 3.7 3.9 3.0 3.1
UI 11 FXFSQ40AVE 24.0 / 50% 3.3 n/a 3.9 2.8 3.1
UI 12 FXFSQ40AVE 24.0 / 50% 3.3 n/a 3.9 2.8 3.1
UI 13 FXFSQ50AVE 24.0 / 50% 4.0 n/a 4.8 3.4 4.7
UI 14 FXFSQ50AVE 24.0 / 50% 4.0 n/a 4.8 3.4 4.7
UI 15 FXFSQ50AVE 24.0 / 50% 4.0 n/a 4.8 3.4 4.7
UI 16 FXFSQ50AVE 24.0 / 50% 4.1 n/a 4.8 3.4 4.7
UI 17 FXFSQ50AVE 24.0 / 50% 4.1 n/a 4.8 3.4 4.7
UI 18 FXFSQ50AVE 24.0 / 50% 4.6 n/a 4.8 3.9 4.7
UI 19 FXFSQ50AVE 24.0 / 50% 4.6 n/a 4.8 3.9 4.7

Required cooling capacity towards the outdoor unit: 77.6kW.

Simultaneous operation calculation


Name FCU Tmp C TC SC Tmp H HC
°C kW kW °C kW
UI 1 FXFSQ50AVE 24.0 / 50% 4.2 4.1 20.0 3.9
UI 2 FXFSQ63AVE 24.0 / 50% 5.2 5.0 20.0 4.9
UI 3 FXFSQ71AVE 24.0 / 50% 5.9 5.5 20.0 5.6
UI 4 FXFSQ63AVE 24.0 / 50% 5.2 5.0 20.0 4.9
UI 5 FXFSQ63AVE 24.0 / 50% 5.2 5.0 20.0 4.9
UI 6 FXFSQ32AVE 24.0 / 50% 2.6 2.3 20.0 2.4
UI 7 FXAQ25PVE 24.0 / 50% 2.1 1.8 20.0 2.0
UI 8 FXAQ25PVE 24.0 / 50% 2.1 1.8 20.0 2.0
UI 9 FXFSQ32AVE 24.0 / 50% 2.6 2.3 20.0 2.4
UI 10 FXFSQ40AVE 24.0 / 50% 3.3 2.8 20.0 3.1
UI 11 FXFSQ40AVE 24.0 / 50% 3.3 2.8 20.0 3.1
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 2
UI 12 FXFSQ40AVE 24.0 / 50% 3.3 2.8 20.0 3.1
UI 13 FXFSQ50AVE 24.0 / 50% 4.2 4.1 20.0 3.9
UI 14 FXFSQ50AVE 24.0 / 50% 4.2 4.1 20.0 3.9
UI 15 FXFSQ50AVE 24.0 / 50% 4.2 4.1 20.0 3.9
UI 16 FXFSQ50AVE 24.0 / 50% 4.2 4.1 20.0 3.9
UI 17 FXFSQ50AVE 24.0 / 50% 4.2 4.1 20.0 3.9
UI 18 FXFSQ50AVE 24.0 / 50% 4.2 4.1 20.0 3.9
UI 19 FXFSQ50AVE 24.0 / 50% 4.2 4.1 20.0 3.9
Σ 74.0 69.7

Name Sound PS MCA WxHxD Wght


dBA A mm kg

UI 1 34-44 220V 1ph 1.5 840x288x840 26


UI 2 34-44 220V 1ph 1.5 840x288x840 26
UI 3 34-44 220V 1ph 1.5 840x288x840 26
UI 4 34-44 220V 1ph 1.5 840x288x840 26
UI 5 34-44 220V 1ph 1.5 840x288x840 26
UI 6 25-30 220V 1ph 0.4 840x204x840 20
UI 7 31-36 220V 1ph 0.4 795x290x238 11
UI 8 31-36 220V 1ph 0.4 795x290x238 11
UI 9 25-30 220V 1ph 0.4 840x204x840 20
UI 10 25-32 220V 1ph 0.5 840x204x840 20
UI 11 25-32 220V 1ph 0.5 840x204x840 20
UI 12 25-32 220V 1ph 0.5 840x204x840 20
UI 13 34-44 220V 1ph 1.5 840x288x840 26
UI 14 34-44 220V 1ph 1.5 840x288x840 26
UI 15 34-44 220V 1ph 1.5 840x288x840 26
UI 16 34-44 220V 1ph 1.5 840x288x840 26
UI 17 34-44 220V 1ph 1.5 840x288x840 26
UI 18 34-44 220V 1ph 1.5 840x288x840 26
UI 19 34-44 220V 1ph 1.5 840x288x840 26

Outdoor unit placed 15.0m above the indoor units.


The minimum connection ratio for this height difference is 50%.

3. Outdoor Unit Details


3.1. Table of Abbreviations
Name Logical name of the device
Model Device model name
▼ Optimized selection: Smaller outdoor model selected than standard proposed model
Tmp C Outdoor temperature in cooling
CC Available cooling capacity
Rq CC Required cooling capacity
EER EER at nominal conditions for standard efficiency series (nominal temperatures, 100% connection ratio and
without considering pipe length corrections)
ESEER European Seasonal Energy Efficiency Ratio
Tmp H Outdoor conditions in heating (dry bulb temp. / RH)
HC Available heating capacity (integrated heating capacity)
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 3
Rq HC Required heating capacity
COP COP at nominal conditions for standard efficiency series (nominal temperatures, 100% connection ratio and
without considering pipe length corrections)
Piping Largest distance from indoor unit to outdoor unit
Bse Refr Standard factory refrigerant charge (5m actual piping length)
excluding extra refrigerant charge
For calculation of extra refrigerant charge refer to the databook
Ex Refr Extra refrigerant charge
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHxD WidthxHeightxDepth
Wght Weight of the device

3.2. Outdoor Details


Name Model Comb Tmp C CC Rq CC EER ESEER Tmp H HC Rq HC COP
% °C kW kW °C kW kW
UE 1 RHXYQ32ATL ▼ 111 32.0 74.0 (-4.7%) 77.6 4.1 0.0 / 50% 69.7 4.3

Name Model Piping Refrigerant


m Type Bse Refr Ex Refr
kg kg
UE 1 RHXYQ32ATL 51.3 R410A 14.6 19.4

Name Model PS MCA WxHxD Wght


A mm kg
UE 1 RHXYQ32ATL 220V 3ph
* RHXYQ22ATL 76 1240x1657x765 317
* RHXYQ10ATL 38.1 930x1657x765 213

Sufficient distance should be respected between the modules according to the service & operation space rules as
mentioned in the databook.

4. Piping Diagrams

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 4
Pipes marked with * in the diagrams must be connected to the device with a reducing joint.

4.1. Piping UE 1

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.

Page 5
UE 1
RHXYQ32ATL
RHXYQ22ATL RHXYQ10ATL

⅝"×1⅛" ⅜"×⅞"

BHFP22P100

20.0m 3.0m [1] 4.0m [2] 2.0m 1.0m 1.0m 3.0m [1] 5.0m [1]
¾"×1¼" ⅝"×1⅛" ½"×1⅛" ½"×1⅛" ⅜"×⅞" ⅜"×⅞" ⅜"×¾" ⅜"×⅝"
KHRP26A73T + KHRP26A72T KHRP26A72T KHRP26A72T KHRP26A33T KHRP26A33T KHRP26A22T KHRP26A22T
KHRP26M73TP

1.5m [3] 4.0m [3] 2.0m [3] 5.0m [3]


¼"×½" ¼"×½" ¼"×½" ¼"×½"
UI 18 UI 13 UI 14 UI 15
5.0m [2] FXFSQ50AVE FXFSQ50AVE FXFSQ50AVE FXFSQ50AVE
⅜"×⅝"
KHRP26A22T

5.0m [3] 5.0m [3] 2.0m [3] 5.0m [3]


¼"×½" ¼"×½" ¼"×½" ¼"×½"
UI 9 UI 10 UI 11 UI 12
4.0m FXFSQ32AVE FXFSQ40AVE FXFSQ40AVE FXFSQ40AVE
⅜"×⅝"
KHRP26A22T

2.0m [3] 5.0m [3]


¼"×½" ¼"×½"
UI 17 UI 16
2.0m 2.0m [1] FXFSQ50AVE 1.0m FXFSQ50AVE 8.0m [1] 1.0m 2.0m 2.0m
⅝"×1⅛" ½"×1⅛" ½"×1⅛" ½"×1⅛" ⅜"×⅞" ⅜"×¾" ⅜"×⅝"
KHRP26A72T KHRP26A72T KHRP26A72T KHRP26A72T KHRP26A33T KHRP26A22T KHRP26A22T

5.0m [3] 5.0m [3] 5.0m [3] 5.0m [3] 5.0m [3] 7.0m [5]
¼"×½" ⅜"×⅝" ¼"×½" ⅜"×⅝" ⅜"×⅝" ⅜"×⅝"
UI 6 UI 5 UI 1 UI 4 UI 2 UI 3
3.0m [2] FXFSQ32AVE FXFSQ63AVE FXFSQ50AVE FXFSQ63AVE FXFSQ63AVE FXFSQ71AVE
⅜"×⅝"
KHRP26A22T

1.5m [3] 2.0m [3] 5.0m [3]


¼"×½" ¼"×½" ¼"×½"
UI 19 UI 7 UI 8
FXFSQ50AVE FXAQ25PVE FXAQ25PVE

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 6
4.2. Wiring UE 1
to centralized controller
P1,P2
UE 1 UI 19 BRC1E62
RHXYQ32ATL FXFSQ50AVE
OUT F1,F2 IN F1,F2 F1,F2 L, N 1.5A 1ph
RHXYQ22ATL
Q1,Q2 L1,L2,L3 P1,P2
UI 7 BRC1E62
76A 3ph
FXAQ25PVE
RHXYQ10ATL F1,F2 L, N 0.4A 1ph
Q1,Q2 L1,L2,L3
38.1A 3ph P1,P2
UI 8 BRC1E62
FXAQ25PVE
F1,F2 L, N 0.4A 1ph

P1,P2
UI 6 BRC1E62
FXFSQ32AVE
F1,F2 L, N 0.4A 1ph

P1,P2
UI 5 BRC1E62
FXFSQ63AVE
F1,F2 L, N 1.5A 1ph

P1,P2
UI 1 BRC1E62
FXFSQ50AVE
F1,F2 L, N 1.5A 1ph

P1,P2
UI 4 BRC1E62
FXFSQ63AVE
F1,F2 L, N 1.5A 1ph

P1,P2
UI 2 BRC1E62
FXFSQ63AVE
F1,F2 L, N 1.5A 1ph

P1,P2
UI 3 BRC1E62
FXFSQ71AVE
F1,F2 L, N 1.5A 1ph

P1,P2
UI 17 BRC1E62
FXFSQ50AVE
F1,F2 L, N 1.5A 1ph

P1,P2
UI 16
FXFSQ50AVE
F1,F2 L, N 1.5A 1ph

P1,P2
UI 9 BRC1E62
FXFSQ32AVE
F1,F2 L, N 0.4A 1ph

P1,P2
UI 10 BRC1E62
FXFSQ40AVE
F1,F2 L, N 0.5A 1ph

P1,P2
UI 11
FXFSQ40AVE
F1,F2 L, N 0.5A 1ph

P1,P2
UI 12 BRC1E62
FXFSQ40AVE
F1,F2 L, N 0.5A 1ph

P1,P2
UI 18 BRC1E62
FXFSQ50AVE
F1,F2 L, N 1.5A 1ph

P1,P2
UI 13
FXFSQ50AVE
F1,F2 L, N 1.5A 1ph

P1,P2
UI 14
FXFSQ50AVE
F1,F2 L, N 1.5A 1ph

P1,P2
UI 15 BRC1E62
FXFSQ50AVE
F1,F2 L, N 1.5A 1ph

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 7
5. Device Options
5.1. Outdoor Unit Options
Model Description Used by
BHFP22P100 Outdoor unit multi connection piping kit UE 1 [RHXYQ32ATL]

5.2. Indoor Unit Options


Model Description Used by
BYCSP125BW1 Decoration panel UI 1 [FXFSQ50AVE] UI 2 [FXFSQ63AVE] UI 3 [FXFSQ71AVE]
UI 4 [FXFSQ63AVE] UI 5 [FXFSQ63AVE] UI 6 [FXFSQ32AVE]
UI 9 [FXFSQ32AVE] UI 10 [FXFSQ40AVE] UI 11 [FXFSQ40AVE]
UI 12 [FXFSQ40AVE] UI 13 [FXFSQ50AVE] UI 14 [FXFSQ50AVE]
UI 15 [FXFSQ50AVE] UI 16 [FXFSQ50AVE] UI 17 [FXFSQ50AVE]
UI 18 [FXFSQ50AVE] UI 19 [FXFSQ50AVE]

6. Centralized Controllers
6.1. Concept

Global Controller Models Control Groups

iTouchManager Grupo de Control 1


# controllers 1 UE 1 (19) # outdoors 1
# indoors 19

6.2. Grupo de Control 1

UE 1 (19)
RHXYQ32ATL OUT F1,F2

iTouchManager
DCM601A51

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 8